HS Code |
808550 |
| Chemical Name | DL-Dithiothreitol |
| Synonyms | DTT, Cleland's reagent |
| Molecular Formula | C4H10O2S2 |
| Molecular Weight | 154.25 g/mol |
| Cas Number | 3483-12-3 |
| Appearance | White crystalline powder |
| Solubility | Soluble in water |
| Purity | ≥99% (for electrophoresis) |
| Storage Temperature | 2-8°C |
| Function | Reducing agent for electrophoresis |
| Ph 10 Solution | 5.5-7.0 |
| Odor | Slight characteristic odor |
| Melting Point | 42-44°C |
| Merck Index | 14, 3171 |
| Hazard Statements | H315, H319, H335 |
As an accredited DL-Dithiothreitol [for Electrophoresis] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The DL-Dithiothreitol comes in a 5g amber glass bottle with a Sigma Aldrich/Suppliers label, sealed for laboratory electrophoresis use. |
| Shipping | DL-Dithiothreitol [for Electrophoresis] is shipped in tightly sealed containers to prevent moisture and air exposure. It is typically transported at ambient temperature but may require cool packs in hot climates. The package complies with chemical safety regulations, and handling instructions are provided. Shipping is restricted to qualified institutions or laboratories. |
| Storage | DL-Dithiothreitol [for Electrophoresis] should be stored in a cool, dry, and well-ventilated area, preferably at 2–8°C (refrigerated) and protected from light. Keep the container tightly closed and away from moisture and oxidizing agents. Proper storage minimizes degradation and maintains reagent quality for reliable use in electrophoresis applications. Strictly follow manufacturer and institution-specific chemical safety guidelines. |
Competitive DL-Dithiothreitol [for Electrophoresis] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Making DL-Dithiothreitol [for Electrophoresis] is not just another step in our catalog. Over years of producing fine chemicals, we've learned that small differences in reagent quality will show up in your results. We produce DTT at a purity that supports sharp and readable gels. Analytical teams in our plant test each batch to confirm content, water, and the absence of interfering ions because contamination always leads to unreliable bands and background smears. Every lot comes out with parameters suitable for delicate work like SDS-PAGE and reducing protein aggregation, which means you will get consistent breaking of disulfide bonds where you need it.
We keep our model for this product focused on research electrophoresis. Our batches run in a stable, white crystalline powder with low hygroscopicity. DL-Dithiothreitol won't clump under proper storage, supporting long shelf life and greater ease of weighing. Purity levels match or exceed industry standards used by biotech labs and academic researchers, usually above 99% by HPLC, which is checked for reducing activity rather than just relying on catalog claims. Residual water and acid/base residues are checked during every production run.
Enzymes, reducing agents, and buffer components all create a background for experimental outcomes. Unlike non-laboratory grade DTT, our electrophoresis product passes clean in-house tests by running side-by-side against standard commercial benchmarks. The absence of metal contaminants keeps you away from artifactual bands or incomplete sample reduction, a lesson we’ve learned from troubleshooting customer feedback from earlier years. Bioanalytical staff find that off-spec DTT affects the denaturation process in SDS-PAGE. Mixed isomers or excessive oxidized forms don’t break disulfide bonds as completely. With our purification, you see rapid dissolution and a fresh, sharp smell, as low-grade DTT often oxidizes during shipping and storage, introducing background issues.
Many researchers only realize the importance of pure DTT after encountering incomplete protein reduction or extra bands on a gel. Technically, DTT reduces disulfide bridges to free thiols, which lets protein subunits migrate by mass rather than crosslinked structure. Lower grade DTT can bring in extra oxidizing agents or fail to reach the needed -SH group concentrations. Mixed batches, non-standard pH, or high moisture samples create variable outcomes. By paying attention to both the synthesis route and the final QC process, we minimize these problems, supporting reproducible research and low variability between gels.
We’ve watched plenty of laboratories struggle with DTT that rapidly loses potency or starts clumping, mostly due to poor drying before bottling. Our process finishes with vacuum drying and low-temperature packaging, keeping moisture levels under control. Every pack leaves with certified moisture below 0.5%. Degradation happens faster in humid conditions, so we encourage desiccator storage, and our packing techs seal every lot in moisture-barrier bags, even for larger bulk sizes. This limits oxidative decomposition during shipment and bench storage. No one benefits from buying a tub of DTT that becomes ineffective in a week.
Another key factor is surface area and particle size. Over-milled DTT becomes dust-prone, leading to static issues in weighing and waste during transfer. We cut our batch granule size to best match micro-balance weighing, reducing frustration when prepping mix solutions. Particles stay uniform—a decision we took after repeated feedback from early university adopters who had to deal with floating dust and measurement error. Each lot goes through particle size analysis to keep these user experiences in mind.
Being the manufacturer allows us to control the whole process. We don’t just receive, repack, and resell—we oversee the synthesis from raw material selection to final bottling. Our team sources raw thiol reagents locally to reduce lag times between preparation and bottling, ensuring less oxidation during manufacture. Before shipment, freshly synthesized material sees a final test for reducing power using the DTNB assay, as well as by comparison with a known protein substrate. This practical step allows us to detect minor impurities or batch drift that purely analytical checks might miss.
Tech support comes right from the plant team, people who have run the syntheses, prepped the bottles, and even loaded the shipping pallets. Over many years, we've handled enough DTT to have seen most issues directly: from accidental contact with air, to clumsy handling of bulk bottles, to problems dissolving in various buffers. These hands-on experiences inform the steps we take in-house and the guidance we offer downstream. Our manufacturing team isn’t reading a datasheet; they’ve spent hours at the bench solving the same issues researchers face every day.
Not all DTT grades act the same in critical applications. We’ve seen customers order general-purpose DTT—often cheaper per kilo—only to find unpredictable results in high-sensitivity protein separations. The main differences stem from trace impurities, moisture content, and the tight control of oxidized by-products. General chemical grade DTT may see wider spec ranges for purity and water content, particularly if it’s aimed at industrial reduction or basic synthetic chemistry. Only by closing the manufacturing loop, monitoring every critical point, and testing each lot by high-sensitivity protein gel, can we guarantee the lot-to-lot stability that keeps your data reliable.
Off-grade DTT sometimes comes blended from multiple synthesis streams. This patchwork approach can show up in broad melting ranges, odd-smelling product, or won’t dissolve rapidly in Tris or phosphate buffers. We run single-stream production and always refilter before bottling. Our customers often mention that our DTT dissolves in seconds, leaving almost no residue and working clearly at expected reducing concentrations. In our experience, high-performance DTT promotes sharp and consistent protein bands from lane to lane—one reason researchers rely on clean reagents to eliminate variable study results.
DTT stands out from other disulfide bond reducers—like β-mercaptoethanol—mostly due to its high reactivity at lower concentrations and less offensive odor. Electrophoresis needs rapid and complete reduction, especially for thiol-rich proteins or samples with stubborn tertiary structure. Many labs switch to DL-Dithiothreitol to bypass the volatility and residual smell that β-mercaptoethanol leaves after running a gel. Across multiple manufacturing runs, we notice that DTT, in our controlled process, leaves behind a cleaner sample, supporting better downstream detection in western blotting and protein staining.
Though TCEP is sometimes selected for its stability under acidic conditions, in our tests, DTT continues to win on price, ease of use, and performance for most routine workflows. Many users don’t switch back once they experience the performance gains with freshly made, high-purity DTT. For applications such as routine proteomics, gene expression studies, or quality control labs, this consistency reduces the number of failed runs and wasted gel cassettes.
Listening to experienced users shapes our quality controls, not generic technical bulletins. Customers from research institutes, biotechnology startups, and teaching labs return year after year, often sharing feedback on how our DTT performs in real-world protocols. These practical results tell us more than headline purity numbers. Some labs noted increased storage stability after we started using double-sealed packaging. Others reported fewer “ghost bands” after we swapped to improved purification steps following a round of client feedback. This continual cycle of feedback, adjustment, and retesting lets us fine-tune every batch for researchers who rely on precision.
Frontline users don’t want grand marketing pitches. They want a supply of reagent that simply solves problems—powder that flows, dissolves rapidly, delivers potent reduction, and doesn’t vary from order to order. By manufacturing on-site and engaging working chemists and lab techs in our QC process, our DTT consistently meets these expectations. Researchers have told us that switching away from mass-market or basic chemical-grade DTT reduced troubleshooting time and waste, especially in demanding proteomics or diagnostic studies.
Many of our industrial and academic partners have kindly shared their protocols and outcomes with us, allowing us to see first-hand where performance requirements change from one method to another. Molecular biologists often focus on reducing RNase contamination when denaturing RNA samples for electrophoresis. Here, DTT’s fast action and absence of trace metals are critical. Protein biochemists need clear reduction of multimeric structures, especially with cysteine-rich targets like antibodies and transporters. These researchers notice immediately if impurities interfere with their downstream blotting or fluorescence readouts.
Quality analytical chemistry demands zero interference in silver-staining or fluorescence-based applications. In-house testing—run under conditions mimicking typical lab use—not only checks for background but also for side effects in colorimetric reactions. We also hear from teaching labs using DTT for large undergrad cohorts. They need both reasonable price and robust performance. Having predictable results for hundreds of student gels makes the small premium for high-grade DTT worth it, compared to budget-grade alternatives.
Our production staff interacts directly with customers facing unique troubleshooting issues. From these conversations, we compile actionable tips. Always open DTT bottles in a low-humidity environment. Scoop directly into a pre-tared weigh boat, then seal the bottle again fast. Limit air exposure by dividing working aliquots into small vials for frequent use, leaving the bulk container tightly closed. Never rely on eye estimation of color or texture to judge potency—old DTT may look fine but lose activity before you notice failures on the gel.
Mix solutions just before use, as DTT oxidizes over time, especially in buffered solutions. Our staff often shares that it takes only a short delay for oxidized DTT to impact reducing efficiency, particularly at low concentrations or in warm rooms. For labs running large numbers of gels, preparing several small aliquots each day keeps each run standardized, reducing experimental variability. Chemists running QC recommend using only the amount needed for immediate preparations—buying in periodic smaller lots has proven more economical and reliable for high-throughput operations.
Our own stores team runs retention samples for each manufactured lot. Stored in sealed glass under nitrogen, periodic checks confirm that product characteristics remain steady for at least 12 months from bottling. Batches stored in open air, or repeatedly exposed and resealed, degrade much faster, often losing vigor for reduction in only a couple of months—a fact we emphasize to regular users. Where practical, we advise lab managers to track lot numbers and storage conditions, associating them with performance outcomes. This feedback has helped us correlate small QC shifts with storage variables and improve our moisture-barrier packaging accordingly.
For big institutions, we offer batch certifications with full analytical trace to lot-specific production runs. This assists in compliance reporting and troubleshooting. Yet even individual research groups can take value from requesting guaranteed lot history, especially for long-term studies or regulated environments. The long view—reliability over repeated buy cycles—remains a key principle in our approach to DTT manufacturing.
Out of all the fine chemicals we prepare for labs, DL-Dithiothreitol for Electrophoresis sits at the intersection of skill and attention to detail. Synthetic precision, rigorous monitoring, and proactive response to user needs all drive our daily decisions on the plant floor. We control moisture, granule size, purity, and batch uniformity for one reason: reproducibility in your results. Our team has spent years learning these lessons the hard way, improving each step based on feedback, experiment, and hands-on troubleshooting. It is this direct experience as the manufacturer—not an outside reseller—that ensures high-quality, dependable DTT for electrophoresis, every time you open a bottle.