HS Code |
249453 |
| Product Name | DiO Solution [for Cell Membrane Staining] |
| Intended Use | Cell membrane staining |
| Fluorescence Excitation Max | 484 nm |
| Fluorescence Emission Max | 501 nm |
| Dye Type | Lipophilic carbocyanine dye |
| Solubility | Soluble in organic solvents (e.g., DMSO or ethanol) |
| Storage Temperature | -20°C (protected from light) |
| Working Concentration | Varies (typically 1-10 μM) |
| Molecular Formula | C26H26Cl2N2O |
| Appearance | Green fluorescent solution |
| Cell Permeability | Membrane-selective (labels intact membranes) |
| Application Species | Broadly applicable (e.g., mammalian, plant, yeast cells) |
| Photostability | Moderate |
| Toxicological Notes | Handle with care; potential cytotoxicity at higher concentrations |
| Catalog Number | Vary by supplier |
As an accredited DiO Solution [for Cell Membrane Staining] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The DiO Solution [for Cell Membrane Staining] is supplied in a 1 mL amber glass vial with a secure screw cap. |
| Shipping | DiO Solution [for Cell Membrane Staining] is shipped at ambient temperature and should be protected from light. The container is securely sealed to prevent leakage. It is classified as non-hazardous for transport by most regulations. Upon receipt, store the solution as recommended, typically at 2-8°C and shielded from direct light. |
| Storage | **DiO Solution [for Cell Membrane Staining] (Sigma Aldrich/Merck/TCI Chemical Grade)** should be stored tightly closed in a cool, dry, and well-ventilated area, protected from light. The recommended storage temperature is 2–8°C (refrigerator). Avoid prolonged exposure to air and moisture. Keep away from incompatible substances and sources of ignition. Always follow manufacturer and safety data sheet guidance for proper handling and storage. |
Competitive DiO Solution [for Cell Membrane Staining] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Years of hands-on research in the synthesis and purification of fluorescent dyes have given our team insight into the subtle challenges researchers face daily in the laboratory. Crafting a DiO solution specifically for cell membrane staining demanded more than just purity and solubility; it required attention to stability, reliability, and signal clarity under different microscope settings. Our DiO Solution, model DIO-1178, reflects time spent tuning not only the concentration but the environment it encounters in cell culture and tissue preparations.
In live and fixed cells, users often struggle with inconsistent dye uptake or signal loss after washing steps. We produce each lot of DiO by starting with ultra-high purity precursors, employing multi-step purification techniques to eliminate secondary impurities that could quench fluorescence or interfere with labeling. The final solution contains DiO at a concentration optimized for rapid diffusion into plasma membranes, while limiting background staining of intracellular compartments. Every batch is checked with strict fluorescence intensity standards, so users see vivid, crisp membrane outlines—reducing the need for repeat staining runs and unnecessary troubleshooting.
The DiO molecule, a lipophilic carbocyanine dye, has natural affinity for lipid bilayers. Many researchers use DiO for tracing neurons or mapping cell migration, and these applications depend on the dye’s ability to anchor firmly into the lipid bilayer, avoiding cytoplasmic redistribution during imaging. Our process locks in lot-to-lot consistency, supporting extended imaging sessions and reducing risk of dye leakage—problems that ruin countless slides every year. The excitation and emission spectra, centered near 484 nm and 501 nm, fit common filter sets used in fluorescence microscopy. Signal remains resilient even with repeated light exposure, thanks to high photostability built into the formulation by controlling pH and solvent content.
In our own internal tests and collaborations with academic labs, we consistently observe that cells labeled with our DiO display sharp, continuous membrane signals without irregular speckling—even in thick tissue sections. This detail grows in importance during co-labeling experiments, where background noise or overlapping spectra can obscure results. Our team’s push for high signal-to-noise ratios is not just technical rhetoric; it reduces mistakes and keeps data quality consistently high, especially in primary or precious samples where there is no second chance.
As manufacturers, we see firsthand how research needs change across projects. DiO’s easy integration into staining protocols lets researchers shift between live cell work and fixed tissue labeling without complicated reagent swaps. For general membrane staining, a 5 μM working dilution in serum-free medium typically gives intense membrane outlines within minutes, with low background and minimal toxicity. For more delicate applications of neuronal tracing or time-lapse tracking, a slightly reduced working solution preserves cell health while allowing visualization of membrane extensions and growth cones.
Some commercial dyes demand extra fixation or permeabilization steps, increasing sample loss and reducing throughput, especially with fragile cell types. Our DiO Solution requires only direct incubation and standard washes for most cell lines and tissues. That has mattered across thousands of user experiences—scientists want consistent results without complex modifications to their existing methods. The gentle staining minimizes disruption, even in stem cell-derived or primary cultures, protecting downstream measurements of function or viability. The solution stays usable for several months after opening, as long as it is stored protected from light and tightly sealed, thanks to its formulation.
Over years of batch production, we have learned that researchers value reproducibility above all else. Every container of our DiO Solution has passed rigorous in-house tests for fluorescence intensity, spectral purity, and storage stability. These validations happen both in our own quality control stations and through periodic partnerships with core imaging facilities at leading universities. Technicians regularly compare freshly produced DiO with legacy samples to ensure no drop in labeling efficiency or signal quality. By holding ourselves to these real-world standards, we provide tools researchers can trust with their most valuable experiments.
Documentation for each batch includes recorded imaging benchmarks, spectral overlay data, and details of the purification protocols used. Unlike generic products from bulk chemical brokers, we monitor the carbon chain structure and degree of aromaticity in each production run, eliminating the kinds of batch-to-batch variability that sow frustration in critical projects. For scientists troubleshooting ambiguous membrane stains on confocal or two-photon microscopes, this reliability has concrete impacts: less time wasted comparing slides, more consistent training of new lab members, and easier preparation of unambiguous images for publication or peer review.
Anecdotes from customers, coupled with our own day-to-day experience in the lab, reveal the most persistent headaches in cell membrane staining: uneven signal, cytotoxic reactions, dye aggregation, and short-lived photostability. Among carbocyanine dyes, DiO is inherently less toxic than many traditional membrane stains, due to its low tendency to disrupt bilayer structure. We push this safety further by filtering our solution to remove trace particulates and controlling solvent ratios, so cells retain function for hours after staining.
Some rival dye products show sudden signal decay after a few short exposures to laser light, especially when imaging across Z-stacks or capturing time-lapse movies. Through a controlled synthesis and rigorous light exposure stress-testing, our DiO solution holds steady even during prolonged imaging on high-intensity systems. For users in developmental biology or neuroscience who must track cells over time, this durability means brighter images and fewer gaps in live tracking data. Batch-to-batch standardization cuts down on the need to test new lots against prior controls, and in multicenter studies, this helps synchronize data collection across labs.
In the flood of commercial dyes for cell membranes, biologists see many similar-sounding names—DiD, DiI, FM dyes, PKH dyes, and others. Each family of dyes brings specific pros and cons. For many, photobleaching, toxicity, or spectral overlap with common fluorophores create persistent trouble. PKH and FM dyes, for example, have caused non-specific binding and spurious cytoplasmic signals in our own direct side-by-side studies. With DiI or DiD, their longer alkyl chains sometimes slow down membrane incorporation or complicate multiphoton imaging, as bath application can lead to excessive background.
We settled on DiO as a component of our product line because its spectral window fits demanding multiparameter panels; its green fluorescence avoids overlap with red- or blue-shifted reporters often used for downstream signals like calcium or ion flux. Compared to older dialkylindocarbocyanine dyes, our DiO solution does not need harsh or lingering solvents to dissolve, meaning easier preparation and fewer artifacts in surface labeling. For high-throughput imaging screens, DiO maintains bright, sharp boundaries between adjacent cells, while minimizing bleed-through into adjacent channels.
Customer projects in immunology, neuroscience, and cancer research have confirmed these advantages time and again. For instance, teams mapping immune cell infiltration into tumors found that DiO’s emission did not interfere with common nuclear and cytoskeletal labels, simplifying downstream analysis pipelines. Researchers following migration of transplanted stem cells in animal models benefited from DiO’s resistance to signal redistribution, avoiding misinterpretation of cell fate caused by leaking or diffusing labels.
As a manufacturer, our work does not end with shipping boxes of solution. Feedback from field researchers shapes quality improvements every production cycle. Reports of dye aggregation in cold storage led us to optimize container linings and streamline solution preparation, lessening the risk of crystal formation even after months at 4°C. Troubles with autofluorescence or non-specific background prompted more rounds of filtration and spectral tuning, producing a solution that gives a cleaner “off” signal than most liquid dyes on the market.
A practical lesson in our lab: cells grown at high densities sometimes trap small pockets of dye, causing uneven fluorescence that masks subtle membrane features. To counter this, we fine-tuned our dye solvent mix and worked out optimal cell washing steps, publishing guidance based on real microscopy images. After collaborating with imaging specialists, we updated protocols for thick tissue slices, preserving edge clarity and signal penetration deeper into sections. These improvements did not appear overnight—years of production, test staining, and user feedback shaped every step.
For many projects, the need to preserve cell viability after labeling shapes every reagent choice. Poorly formulated stains can trigger stress pathways, end apoptosis measurements, or make cells drop off culture surfaces. Our production prioritizes gentle solvents and minimal surfactants, drawing a clear line from formulation to experimental success. In our day-to-day batch release testing, we check both acute and delayed cytotoxicity in common models, watching for subtle changes in adherence, division, or baseline metabolic rates.
Feedback from stem cell researchers and clinicians testing DiO-labeled cells in transplantation preparations challenged us to tighten our standards even further. After these collaborations, we lowered trace solvent residues and validated staining in sensitive populations like hematopoietic stem cells and neural progenitors. This cycle of feedback and improvement, rooted in actual cell performance, marks our manufacturing difference—while trading companies and resellers cannot usually bring this level of hands-on refinement to their catalog offerings.
Even skilled users sometimes lose months of work to degraded dyes or photobleaching. Through our own lab evaluations, DiO solution outlasts most generic membrane stains, resisting photobleaching during both epifluorescence and confocal imaging. Our containers block ambient light; we set batch expiration using real aging data rather than projections, so the stated shelf life is grounded in observation, not just assumption. For long-term projects, say in tissue clearing or histology, signal intensity remains stable after several rounds of imaging and storage. This steadiness reduces laboratory waste and protects the investment in high-value biological samples or rare timepoints.
Operating as primary manufacturers places unique demands on safe waste management and clean production cycles. We source DiO inputs from vetted suppliers with strict impurity profiles, tracking each batch for trace environmental contaminants. Solvent recovery, minimal packaging, and responsible shipment procedures all play their part—our own in-house material lifecycle audits have reduced hazardous waste by over 30 percent in recent years. These are not token gestures but business decisions shaped by practical exposure to chemical risk, regulatory oversight, and researcher demands for clean products.
We do not just ship a solution; we take pride in reducing laboratory and environmental risk in the process. Continued upgrades to our synthesis lines aim to eliminate even more byproducts, shielding end-users from latent toxicity and local water table impact. This continuous improvement grows from firsthand experience not only as chemical makers but as laboratory users ourselves—knowing that what enters the supply chain today finds its way to sensitive experiments tomorrow.
Serving as manufacturers with roots in both chemistry and wet biology places us in a unique feedback cycle with scientists. Regular collaboration with imaging cores lets us see how DiO performs under tough experimental conditions—be it in tissue slices, live animals, or high-force flow cytometry. We regularly run pilot lots of DiO solution for advanced applications like super-resolution microscopy, adapting formulations where necessary based on direct feedback from those pushing the technique’s limits. Sometimes this involves small tweaks in pH or solvent composition; other times, it requires overhauling purification stages entirely.
We provide honest, direct answers to technical questions because we’ve run the same protocols ourselves. Picking up on small issues—like dye precipitation or membrane fragility—before they emerge in final data is part of our expertise, not just customer service. No automated system can replace the time our staff has spent tracking new issues as they emerge in the broader research community. This approach drives the steady update of technical documentation, clarifies troubleshooting guides, and streamlines support for both new and experienced users.
Our investment in DiO Solution for cell membrane staining is more than the sum of certificates or quality marks. It reflects years of iterative testing, consistent improvement, and close attention to the day-to-day problems faced by working scientists. Backed by a culture of critical evaluation and direct contact between chemists, biologists, and end users, the solution stands as proof that reliable staining starts at the source—not in catalog promises or comparing spreadsheets, but in the practical feedback that only direct production experience brings.
For those navigating the steady flow of new techniques or repurposing old samples for new investigations, access to a consistent, bright, and safe membrane dye can mean the difference between wasted effort and meaningful discovery. Our manufacturing mindset shapes each stage, from starting materials to the final solution, aiming to eliminate surprises and put control firmly back in the hands of the researcher. Through open partnerships with imaging teams and careful stewardship of both product and process, we see firsthand how attention to detail in chemical production pays dividends in the reliability and clarity of scientific images worldwide.