Dichloromethane (stabilized with 2-Methyl-2-butene) [for HPLC Solvent]

    • Product Name Dichloromethane (stabilized with 2-Methyl-2-butene) [for HPLC Solvent]
    • Alias dcm-stab-hplc
    • Einecs 200-838-9
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    712558

    Product Name Dichloromethane (stabilized with 2-Methyl-2-butene) [for HPLC Solvent]
    Chemical Formula CH2Cl2
    Molecular Weight 84.93 g/mol
    Cas Number 75-09-2
    Appearance Clear, colorless liquid
    Purity ≥99.8% (for HPLC)
    Boiling Point 39.6°C
    Melting Point -96.7°C
    Density 1.325 g/cm³ at 20°C
    Stabilizer 2-Methyl-2-butene
    Water Solubility 20 g/L (at 20°C)
    Refractive Index n20/D 1.4240
    Flash Point None (non-flammable under most conditions)
    Vapor Pressure 47 kPa at 20°C
    Un Number 1593

    As an accredited Dichloromethane (stabilized with 2-Methyl-2-butene) [for HPLC Solvent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Brown glass bottle, 2.5 L, sealed cap; labeled "Dichloromethane (stabilized with 2-Methyl-2-butene), HPLC grade, Sigma-Aldrich".
    Shipping Dichloromethane (stabilized with 2-Methyl-2-butene, HPLC grade) is shipped in tightly sealed, chemical-resistant containers. It is classified as a hazardous material and requires appropriate labeling and documentation. Shipment follows international and local regulations, including UN number 1593, using specialized packaging to prevent leaks and ensure safety during transport.
    Storage Dichloromethane (stabilized with 2-Methyl-2-butene) for HPLC should be stored in a tightly closed container within a cool, dry, well-ventilated area, away from heat, sparks, open flames, and incompatible substances. Protect from direct sunlight and moisture. Use only with adequate ventilation. Store at room temperature, and ensure container remains tightly sealed to prevent contamination or evaporation. Handle in accordance with standard chemical safety protocols.
    Free Quote

    Competitive Dichloromethane (stabilized with 2-Methyl-2-butene) [for HPLC Solvent] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Dichloromethane (stabilized with 2-Methyl-2-butene) for HPLC Solvent: Insights from the Manufacturer

    Understanding Dichloromethane for HPLC in the Chemical Industry

    The process of producing high-purity dichloromethane isn’t just about meeting a number on a certificate—it’s about making sure every bottle supports the reliability that analytical laboratories and production environments depend on. Over decades spent at the reactor and purification line, the demands of HPLC (high performance liquid chromatography) have become intimately familiar. Quality assurance in this space doesn’t stem from vague promises; it grows from repeatable processes, real-world troubleshooting, and careful understanding of what the end users face in their daily chromatography work.

    Dichloromethane, also called methylene chloride, sits among the most used polar aprotic solvents in chromatography, taking a place in sample prep, extraction, and as a mobile phase partner in normal-phase HPLC separations. The practice of using DCM has evolved in response to ever-stricter detection limits and growing lists of restricted contaminants and stabilizers—driven not just by regulation, but by the pursuit of reproducibility in critical results. Our work as manufacturers centers on the actual purity that makes a difference at the detector.

    Model Offered: Stabilized for Reliable Performance

    Dichloromethane has a tendency, under UV or strong alkaline conditions, to form acid byproducts such as hydrochloric acid. Trace instability, even at the ppb or ppm level, leads to poor baselines, ghost peaks, or rapid column wear. To address this, we use 2-Methyl-2-butene (2M2B) as our stabilizer—a deliberate choice informed by years of side-by-side testing against alternatives like amylene blends or alcohol. 2M2B’s minimal interference signature, even in sensitive UV applications around 230 nm, means users avoid the headaches from unwanted peaks or gradual solvent breakdown, which can slip through unseen until they damage consistency.

    The stabilized DCM solvent offered for HPLC comes out of our continuous distillation with in-line filtration, tailored for low water content (well below 0.01%), and monitored for a range of residuals with every batch. We detail residual levels of halogenated compounds, trace aromatics, and acid byproducts—each with real limits, confirmed through frequent system suitability testing in our own lab, not just on spec sheets.

    Choosing Dichloromethane with 2-Methyl-2-butene: Impact on Chromatography

    In busy analytical labs, downtime quickly passes from inconvenience to real cost. Tar and residue from unstable solvents can force column changeouts after just a few runs. Technical staff have described how non-optimized stabilizers produce subtle fouling and require frequent purging to restore baseline performance. By opting to stabilize with 2M2B, we help deliver a cleaner eluate and prolonged column life. This approach keeps the solvent clear from peroxide-forming byproducts and acidic residues that can creep in from less protected sources.

    Many HPLC users have little tolerance for ghost peaks or questionable artifacts when running trace analysis—especially pesticide residue or pharmaceutical methods with tight specifications. A contaminant or impurity at the wrong retention time can jeopardize method validation or force the rerunning of entire sample sets. Upstream, the focus on real-world blank chromatograms tests each batch in the same way chromatographers work: solvent is run as a blank, with monitoring for any system noise or abnormal peaks. This process happens before a drum ever leaves the facility, ensuring that the difference isn’t just on paper.

    DCM stabilized with 2M2B also sees careful monitoring for trace stabilizer artifacts in UV and MS detection—part of an iterative quality protocol built with feedback from our own technical support calls and visits to contaminated columns or failing baselines. Each year, as detection technologies sharpen, we push down allowable impurity thresholds. Molecular sieve drying, in-line degassing, and constant review of storage tank material compatibility keep reactivity low, avoiding introduction of unexpected leachables or decomposition products during storage or transport.

    What Sets This Product Apart from Other Dichloromethane Solvents

    Not every dichloromethane bottle is created—or handled—the same. After decades shipping both unstabilized and differently stabilized grades, patterns are clear: many low-cost solvents feature generic stabilization, using amylene or small alcohol admixtures. These can leave traces beyond the limits of analytical-grade applications. Amylene, for example, frequently appears on baseline scans of UV detectors, introducing extra peaks and raising background absorbance levels. Alcohol stabilizers, while cheaper for bulk use in industry, can bring their own challenge of higher water content, slow column bleed, and extra steps for drying before HPLC injection.

    We adopted 2M2B after careful pilot studies and repeat method trials. While more expensive to source and handle, 2M2B brings a low UV tail and high chemical compatibility with common silica and bonded phase stationary phases, even in delicate separation work. The stabilizer does not hydrolyze to problematic acids over typical storage periods, and actual shelf-life studies show minimal inhibitor consumption or breakdown even under fluctuating warehouse temperatures or variable humidity.

    DCM produced for HPLC also receives different handling and packaging than technical solvents. High-purity polymer liners, batch-specific rinsing of drums and totes, and regular vapor-phase equilibrium checks all come directly from years of experience responding to laboratory complaints about invisible carry-over or “dirty” lots. In rarer cases, non-specific organic halides or plasticizers from packaging migrate into DCM during transit—so we invest in tighter QC, rapid batch-release analytics, and heavy-trace impurity testing that respond directly to issues we’ve seen in the field. No lab wants to postpone a sequence because of mysterious baseline noise, or spend costly analyst hours identifying packaging leachables rather than running their intended method.

    Applications: Meeting the Real Demands of Analytical Laboratories

    Dichloromethane HPLC solvent appeals to analytical labs for its unique combination of volatility, extraction power, and low inherent background. DCM rapidly dissolves lipophilic and semi-polar organic residues, faithfully transferring them into solution phase with little need for elevated temperatures. In sample prep—olive oil pesticide screening, pharma impurities, or environmental water analyses—it draws out a broader range of analytes than less polar solvents like hexane or petroleum ether.

    The volatility of DCM makes concentration steps straightforward, saving valuable analyst time during evaporation or nitrogen blow-down. When competing with lower-boiling ethers or pentanes, dichloromethane leaves less room for operator error or sample loss through excessive evaporation. Our production team understands users expect rapid, predictable evaporation with no sticky residue and absolutely no cross-contamination, particularly at trace or ultra-trace levels.

    Thermostability and inertness in common hardware were demanded by the rise of modern, faster, and more efficient HPLC systems. DCM with 2M2B resists UV degradation and does not react with most common plastics, stainless steel, or PEEK tubing—even in recirculating or automated sampler designs. In our own support history, analytical users switching from unstabilized product showed a drastic drop in unexpected shutdowns, false positives, and recurring baseline issues. The resulting time savings and confidence in data quality balance the higher per-liter cost: fewer reruns, less troubleshooting, and more productive sample throughput.

    From Production Floor to Chromatograph: The Path to Consistency

    Every batch of HPLC-grade DCM starts from carefully selected feedstock, usually derived from chloromethane process streams. Early purification eliminates excess chlorinated byproducts and most water. Multi-stage distillation, under inert gas, drives down levels of chloroform, carbon tetrachloride, and higher chlorinated fractions—impurities that otherwise drift into baseline artifacts or raise health and safety questions. We don’t cut corners with shortcut filtering or “on-spec” blending; instead, real investment goes into monitoring shifts in feedstock quality, persistent sampling for micro-impurities, and validating that each lot responds the same in the lab as it does on the analyzer.

    Manufacturing doesn’t stop at distillation. Storage vessels, transfer lines, and filling systems run on strict schedules for cleaning and inspection. Real-world contamination events—rust flaking from a stagnant line, or organic residues trapped in bends—teach hard lessons. When we identify stray acid or peroxide contamination, it usually traces back to equipment materials or atmospheric leaks. By controlling atmosphere with dry nitrogen and running regular spot tests for peroxides and organics, we keep the risk of in-process degradation extremely low.

    Filling and packaging processes get as much scrutiny as distillation. Polymer liners, glass ampoules, inert gaskets, and single-use drums avoid cross-contamination. Each packaging lot receives verification for airtightness and compatibility; packaging that fails migration tests isn’t used. Once filled, every batch spends a staged holding period under monitored conditions, until quick-scan lab checks confirm chemical consistency. This extra effort translates into peace of mind—no sour surprises or unexplained artifacts weeks or months after delivery.

    Comparing with Other Grades and Stabilizers: Learned Lessons

    Experience handling solvents for both industrial extraction and analytical use uncovers some persistent myths and lessons around dichloromethane grades. Unstabilized DCM, while cheaper and acceptable for cleaning glassware or flushing lines, breaks down too easily under air or light exposure. Hydrochloric acid forms, lowering pH and quickly corroding columns and metal components. Minor acidification, even at sub-ppm, wreaks havoc on high-sensitivity detectors. Some producers rely on low-cost amylene blends, which suppress acid only until things warm up or samples age. Users quickly report drifting retention times and elevated backgrounds with these alternatives.

    Compared to technical or industrial grades—often sold bulk for resin processing or paint stripping—HPLC-grade solvent brings an entirely different expectation for background purity. Laboratories running high-sensitivity trace work cannot afford even a hint of contamination from nonvolatile or UV-absorbing impurities. Even reliable, general-purpose DCM may hide traces of transporter residues, mothballed plastics, or even cleaning agents that went unnoticed during manufacture. Over years, we saw that only tailored production, stabilizer choice, and validation under real analysis conditions kept users’ application performance consistent, batch after batch.

    Multi-modal chromatography platforms, particularly in pharmaceutical and pesticide labs, now scrutinize solvent performance at new levels of sensitivity. As users push detection down to single-digit ppb or even ppt, weakly stabilized or insufficiently pure dichloromethane simply doesn’t keep pace. By tackling each source of impurity and instability—be it from feedstock, stabilizer/byproduct, packaging, or transport—the end result passes the most intensive challenge: successful chromatography at high sensitivity, maintained for the lifetime of each column and instrument.

    Challenges and Solutions Sourced Straight from Operations

    Manufacturing solvent isn’t just about chemistry: it’s logistics, training, and responsive quality assurance. For solvent batches showing unexplained spikes in total acid or baseline drift, the answer usually lies in real-world factors—intermittent vacuum loss during distillation, subtle tears in tank linings, aging gaskets, or even everyday forklift jostling. Responding means investing in extra layers of monitoring and quick investigation whenever instrument or field laboratory results suggest something out of spec.

    Users have called in about slight haze, strange odors, or pressure build-ups in supposedly “sealed” DCM containers. Investigation often reveals oxygen ingress or a stabilizer depletion edge case, especially in variable climate transport. To counteract these risks, our teams double down on inert-atmosphere packaging, tighter closure testing, and regular shelf-life studies—even if it slows production rates. Preventive action, not just corrective, has saved countless customer runs and built an enduring trust with analytical clients.

    High-grade dichloromethane, in all its volatility, also demands responsible storage and hazard management. From a manufacturer’s side, stability hinges on airtight containment, protection from direct sunlight, and rigorous monitoring for pressure changes. Recommendations for users are rooted in firsthand mishap experience: tight re-capping after each use, cold storage for long-term supply, and immediate disposal of any yellowed or sharply acidic-smelling containers. Continuous education for operators—on both factory and lab floors—keeps everyone safe and solvent quality high. Quick response to even a single off-batch complaint drives longer-term changes in how we schedule maintenance, select packaging, and communicate with customers.

    Supporting Users at All Scales: Big Volumes and Small Bottles

    Dichloromethane for HPLC isn’t just about purity in the chemical sense: it’s an entire system of production, packaging, quality, and support designed for laboratory confidence. For large-scale contract labs or small boutique research outfits, just a few ppm of the wrong impurity can mean countless wasted hours. Years of field feedback have proven that repeat customers value transparency, actionable batch data, and honest troubleshooting over perfunctory “certified” status. Open lines with users—from monthly update calls, urgent rush shipments, to direct shipment of sample vials for troubleshooting—help solve issues before they become crises.

    We often see scales of use running from single-liter bottles on academic benches to 200-liter drums in high-volume regulation laboratories. No matter the size, expectations don’t change: every container needs to perform as predictably as the last, with no mystery spikes or delays. Our batch release process, built from the reality of real-world chromatographer needs, reflects this commitment. Every sample run—including system suitability, blank tests, and operator technique checks—is benchmarked against end-user expectations, not just regulatory compliance. This focus on measured results, technical support, and long-term analytics underscores the actual value in our stabilized HPLC-grade dichloromethane.

    How Continuous Improvement Shapes Our Production

    Remaining static would mean ignoring both advances in chromatography and the changing world of chemical safety. As automation in labs grows and as solvent recovery/recycling increases, solvent residues, stabilizer breakdown products, and extractables have moved to the forefront of analytical concern. Listening to the steady flow of feedback from users—unexpected peaks, rising blank backgrounds, or column endurance drop-off—motivates direct changes in our purification, stabilization, and packaging. Each complaint or failure serves as an early warning, propelling us toward cleaner, more reliable product with each cycle.

    Pilot studies with collaborators regularly challenge us to exceed even present-day standards. We run in-depth storage and aging studies, pushing dichloromethane samples through simulated shipping, warehouse, and field-lab conditions. Cross-referencing headspace analysis, GC-MS traces, and UV-Vis profiles drives down impurity limits year over year. Technical teams don’t just read reports; they visit customer sites, troubleshoot stuck runs, and see firsthand the cost of contamination-driven downtime. These experiences fold directly back into updates to our stabilization, packaging, process validation, and technical training.

    Final Thoughts on Meeting the Needs of the Analytical Community

    Supplying dichloromethane stabilized with 2-Methyl-2-butene for HPLC demands more than chemical know-how. It’s a relationship built on learning from every chromatogram, every call about a stuck column, every delivery issue, and every round of customer validation. Our role as a manufacturer only grows as methods get more sensitive and as users push for data-driven confidence in every run. It isn’t just a promise of “analytical grade” on the label; it’s a daily practice of rigorous processing, traceability, and personal accountability that turns a simple solvent into a tool trusted by some of the world’s most demanding scientists.

    From sourcing cleanest feedstock and adopting 2M2B as the stabilizer, to close monitoring of packaging lines and relentless focus on impurity testing, everything feeds back into delivering predictable, repeatable HPLC performance. The solvent is more than a commodity; it is an unseen but central collaborator in every day’s results for labs across the world. Learning from each challenge and open to every improvement, we strive to provide a level of reliability and technical partnership that research and industrial labs have come to expect—and demand—from a direct manufacturer.