West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Dibutylamine [for HPLC]

    • Product Name Dibutylamine [for HPLC]
    • Alias DBA
    • Einecs 203-681-2
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    753756

    Product Name Dibutylamine [for HPLC]
    Chemical Formula C8H19N
    Molecular Weight 129.24 g/mol
    Cas Number 111-92-2
    Purity ≥99%
    Appearance Colorless to pale yellow liquid
    Boiling Point 159-161 °C
    Melting Point -60 °C
    Density 0.77 g/mL at 20 °C
    Solubility In Water Moderately soluble
    Refractive Index 1.423-1.425
    Vapor Pressure 2.7 mmHg at 20 °C
    Storage Temperature Room temperature
    Flash Point 45 °C (Closed cup)
    Grade For HPLC

    As an accredited Dibutylamine [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dibutylamine [for HPLC], 100 mL, packaged in an amber glass bottle with a secure cap, labeled Sigma-Aldrich/Merck/TCI.
    Shipping Dibutylamine [for HPLC] is shipped in tightly sealed containers to prevent leakage and contamination, typically in amber glass bottles for light protection. Packaging conforms to international chemical safety regulations, with hazard labeling. Shipping is via certified couriers specializing in chemicals, ensuring compliance with DOT, IATA, and IMDG standards for flammable liquids.
    Storage Dibutylamine [for HPLC] should be stored in a tightly closed container, in a cool, dry, well-ventilated area, away from sources of ignition and incompatible substances such as strong oxidizers and acids. Keep away from heat and direct sunlight. Store at room temperature, following the manufacturer's safety guidelines (Sigma Aldrich/Merck/TCI grade) and local chemical storage regulations.
    Free Quote

    Competitive Dibutylamine [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Dibutylamine [for HPLC]: Insights from the Manufacturing Floor

    Why Purity in Dibutylamine Matters for HPLC

    Actively working with chemical synthesis and purification has put us close to the needs of analysts relying on high performance liquid chromatography. Dibutylamine often gets attention for its reactivity and volatility, but the challenge comes when shifting from general industrial grade to true HPLC-grade material. Trace impurities—residual water, aldehydes, or ionic contaminants—can disrupt baselines, skew retention times, or cause ghost peaks even in trace amounts.

    We’ve learned through years of hands-on production that consistent purity doesn't result from a lucky batch. It takes dedicated equipment, careful handling, and constant monitoring along the chain. When preparing dibutylamine for HPLC applications, every step—from starting raw material qualification through each fraction of distillation—is tuned to minimize background interference for chromatographers who cannot afford wasted runs. False positives or contaminated peaks not only waste solvent and time, they risk decisions on product lots, research findings, or environmental monitoring.

    Production Details Define the Product

    Standard dibutylamine may come from basic amine synthesis via n-butyl chloride and ammonia over a fixed-bed catalyst. This yields a product fine for generic organics, but leaves open the door for side reactions. For HPLC grade, our process includes additional distillation rounds under inert gas, scrubbing of feints, and rigorous exclusion of acidic residues. Each drum or flask gets sealed off from ambient air to avoid amine oxidation or water ingress—simple laziness here leads to degradation long before it gets to a chromatograph.

    Analytical tests run each production lot through not just content determination by GC, but background testing with blank HPLC injections. This shows exactly what background ghosts a technician would see, not only what an IR scan or titration would indicate. Numbers from these runs document low UV absorbance, minimal baseline drift, and minimal secondary peaks—without this data, claims of “HPLC grade” are empty.

    What Sets HPLC-Grade Dibutylamine Apart

    Users sometimes confuse technical or industrial grades with chromatographic purities, and the issue usually reveals itself on the bench. Technical grades might serve well in cleaning, polymerization, or manufacturing intermediates, but HPLC users face stricter requirements. We provide a product with UV transmittance curves and batch-specific impurity profiles. Total purity falls above 99.5 percent, but the crucial question comes from the trace level background—do any byproducts or degradants co-elute with common analytes, or interact with detection wavelengths?

    Our product undergoes specialized filtration, not just through carbon but fine-particulate filters designed for analytical solvents and reagents. This removes tiny metal ions or silicaceous debris missed in industrial filtration. Storage happens under humidity-controlled nitrogen atmosphere—moisture is a recipe for degraded columns and sample reliability, a problem we’ve wrestled with and addressed directly. All working lots pass microbial and particulate load testing, supporting researchers and analysts who depend on repeatable results day after day.

    Working With Feedback: Real Lab Experiences

    Communicating with our long-term partners exposes us to where dibutylamine’s purity really impacts outcomes. Some pharmaceutical labs reported “drifting blanks” during trace analysis, only to trace this to vendor switch on amines. Our lots, subjected to stricter carbonyl and water controls, immediately resolved those issues. In another case, a food research institute needed a base additive for ion-exchange HPLC but faced regulatory demands for full impurity traceability. Supplying batch logs and impurity mapping let them submit convincing data and avoid compliance delays. Experiences like these have pushed us to collect more real-life feedback, using it to drive production changes.

    The value here does not come just from tighter spec numbers, but from ongoing connection to the labs actually running HPLC. We encourage feedback both positive and negative, using it to spot weaknesses in our process and to continuously upgrade. Our close ratios with column manufacturers have also helped us preempt issues, as older resins or different silica grades can react in unusual ways with amines, especially where there are trace leachables in the product.

    Addressing Moisture and Residual Impurities

    Moisture remains one of the chief enemies for anyone creating high-purity amines. Even a few hundred parts per million create hydrolysis or artifact peaks. To manage this, our facility has worked out a series of vacuum drying procedures post-distillation and rapid hot-transfer to sealed containers. Samples are taken both automatically and manually through septum ports—if we spot any aberration in the Karl Fischer results, the batch halts for redistillation. This isn’t just a theoretical step; missed moisture can mean entire HPLC runs must be discarded.

    We find that trace aldehyde contamination shows up more frequently in batches made from recycled amines or less purified synthesis intermediates. Dedicated glass-lined reactor systems and strict temperature control reduce these formation paths. We also do not cut corners by blending batches to “average out” purity—only single-batch material with traceable testing history moves forward. This gives each end-user confidence that what goes into their HPLC mobile phase won’t become a surprise source of signal interference.

    Safe Handling and Consistent Results

    Years of handling and storing aminic chemicals teach a thorough respect for process discipline. Dibutylamine reacts with acids, oxidizers, and strong electrophiles, and so must be transported in containers completely free of halides or peroxides. We use lined steel drums or thick-walled glass, each cleaned with carefully monitored solvent rinses that are then tested for extractables. Staff working on packaging and shipping receive ongoing safety training—small mistakes in handling lead to contamination, which cascades into the final product and the subsequent frustrations for downstream users. Using an inert-atmosphere bottling system, we preserve both the chemical and physical purity from production through to your lab bench.

    Customers have told us that reliable chemical consistency has let them cut down on unnecessary reruns and unproductive troubleshooting. Our preparation methods mean labs do not spend extra time running QC tests on their reagents; this trust results from years of minimized impurity variance, demonstrable on each batch record and chromatogram.

    Comparing HPLC-Grade to Conventional Grades

    Technical or reagent grades may slide through in less sensitive synthetic chemistry. For HPLC purposes, residual color, baseline absorbance in the 210 or 254 nm range, and presence of nitrogenous byproducts all matter. High-purity HPLC-grade dibutylamine undergoes more than the typical elemental analysis—it gets full-spectrum UV-Vis scans, advanced GC-MS trace profiling, and batch-retained samples for at least two years post-manufacture, a safeguard we originated based on requests for after-the-fact investigations.

    Lower grades—often marked only as “pure” or “reagent”—typically meet only minimum assay requirements. They lack documentation of background absorbance, particulate load, or batch-resolved water content. For those running sensitive LC-UV or LC-MS testing, this difference manifests as inconsistent baselines and surprise contaminants.

    In recent years, increased demand for trace-level contaminant detection in clinical and environmental settings has driven even stricter standards. In response, our analytics team has been tasked with reviewing not only batch release standards but also new impurity markers—those hard-to-detect agents that emerge as end-user applications get more sophisticated. This keeps the product truly fit for evolving needs.

    Supporting Advanced Applications

    Researchers investigating trace-level pharmaceuticals, food additives, or even pesticides in soil or water need reagents that reinforce confidence in their results. We frequently provide detailed impurity certificates, showing more than just binary “pass/fail” standard results. Customers performing method development in proteomics, for instance, rely heavily on the stability and low-UV interference of each additive. This can only be met by continuous data collection, lot validation, and quick-turn technical support for questions about specific contaminant profiles.

    We also find more labs adopting direct-injection LC-MS for emerging analytes—one of the most punishing applications for amines due to their potential for adduct formation or in-source fragmentation. For these researchers, knowing each lot shows consistent, ultra-low background, and molecular profile matters more than hitting a one-time percentage mark. Our regular stability studies track the evolution of each batch, identifying any uptrends in background peaks that might build up in long-term storage or with repeated sample exposure. We then proactively share these results, guiding our customers on the best handling and use practices.

    Traceability and Documentation

    Analytical reproducibility depends as much on paper trails as on chemical purity. Every batch produced gets a full stack of test results, operator logs, and traceable supply chain documentation. We saw, from auditor visits, that clients benefit directly from being able to trace lot history, production dates, and even the operator signatures attached to each vessel. This addresses regulatory demands and helps analysts track any anomalies back to source, not only for their assurance but for ours—we hold ourselves accountable with the same documentation end-users expect.

    Lot-specific certificates align with ISO 9001 standards and customer reporting forms. For any new order, customers receive real chromatograms and UV curves from the actual batch shipped, with in-house and external testing labs crosschecking at random. This routine keeps us strict on internal compliance and gives users real-world evidence of consistency.

    Continuous Improvement Driven by End-User Experience

    Standing on the factory floor, real-world feedback offers a unique guide. We hear how the smallest shifts in water, trace metals, or background UV absorbance can upend days of work downstream. Discovering this through open feedback, we regularly adjust the headspace management in reactors, tweak filtration media, and revise cleaning protocols for all filling lines. Modern LC/MS sensitivity will expose impurities that older production methods would have left undetected.

    Our in-house R&D has introduced automated impurity profiling for every major synthetic step, responding to customer input that rival products were failing under increased detection scrutiny. We track these incremental changes as experimental records—not only for internal QA, but to share with customers aiming to meet next-generation regulatory or scientific standards.

    Logistics: Ensuring Quality from Loading Dock to Benchtop

    Maintaining dibutylamine’s quality doesn’t end with synthesis and bottling; transport can undo weeks of careful work. Containers ship with tamper-evident seals and humidity detection tags. Our drivers and warehouse staff follow a checklist that includes temperature checks, documentation of vehicle conditions, and hand-off inspections for every shipment. If a lot spends too long exposed to variable temperature and humidity, it risks picking up moisture—so each customer receives a guarantee of maximum elapsed time between lot release and delivery.

    Whenever international customers must navigate extended transit, we provide not only technical advice but bonus aliquots for rapid in-lab comparison against existing reserve samples. Some clients told us this extra flexibility allowed them to confidently retire old product without risking test interruptions. The reliability built into this supply plan grows from our own headaches finding inconsistent inbound reagents on our own analytical projects.

    Why We Stay Hands-On With Every Lot

    After decades in chemical manufacturing, we know small production tweaks ripple out over hundreds of research projects. By developing HPLC-grade dibutylamine with in-house chemistry teams, dedicated purification lines, and continuous direct lab feedback, we serve the community that expects true reliability. Our team walks the plant every day, checks on distillation columns, records every observation, and answers late-night technical queries from customers battling complex application hurdles. We see no shortcuts, no hand-off to brokers without first ensuring every shipment matches the transparency and purity needed for chromatographic confidence.

    Looking Forward: Meeting Future Analytical Challenges

    Changing applications drive us to keep improving. Ever-tighter regulatory limits, more demanding detection methods, and increasingly complex analyte matrices mean today’s HPLC-grade may be tomorrow’s baseline. Our ongoing investments in process control, documentation, and analytical technology come from this awareness: each research outcome or regulatory submission depends on our diligence. We remain committed to delivering dibutylamine designed for real-world chromatography—not just by specification, but by the lived experience of our customers and our own teams.