West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Dansyl Chloride

    • Product Name Dansyl Chloride
    • Alias DNS-Cl
    • Einecs 202-607-8
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    888306

    Product Name Dansyl Chloride
    Iupac Name 5-(Dimethylamino)naphthalene-1-sulfonyl chloride
    Cas Number 94-19-9
    Molecular Formula C12H12ClNO2S
    Molecular Weight 269.75 g/mol
    Appearance Pale yellow to greenish crystals or powder
    Melting Point 128-130°C
    Solubility Soluble in acetone, chloroform, and alcohol
    Storage Conditions Store at 2-8°C, protect from moisture and light
    Purity Typically ≥98%
    Synonyms DNS-Cl, Dansyl chloride, 1-Dimethylaminonaphthalene-5-sulfonyl chloride
    Usage Fluorescent labeling reagent for amino acids and peptides

    As an accredited Dansyl Chloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Dansyl Chloride, 5 grams, supplied by Sigma-Aldrich/Merck/TCI, packaged in an amber glass bottle with hazard labeling for laboratory use.
    Shipping Dansyl Chloride (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed containers to protect from moisture and light. The package follows hazardous material regulations, with clear labeling and safety data sheets included. Shipping is typically done via ground or air with temperature control as necessary to maintain chemical integrity.
    Storage Dansyl Chloride should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from moisture and incompatible substances such as strong acids and bases. Store at room temperature, protected from light. Avoid exposure to air and humidity to prevent decomposition. Ensure proper labeling and follow relevant safety guidelines as recommended by suppliers like Sigma Aldrich, Mreck, or TCI.
    Free Quote

    Competitive Dansyl Chloride prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Dansyl Chloride: Precision in Protein and Peptide Analysis

    The Backbone of Reliable Derivatization

    Manufacturing dansyl chloride involves much more than mixing a few chemicals. Each batch that leaves our facility reflects choices made at every step of production—refining the process for purity, monitoring for consistent particle size, and ensuring the reagent’s functional groups remain intact. This isn’t just a lab exercise. For protein sequencing work, for fluorescence tagging in HPLC, or for bringing trace-level amino acids to light in complex matrices, even minor impurities or moisture variations can send results off-track.

    The standard product carries the model name “DSC-99” and reaches a chemical purity exceeding 99%, verified with HPLC and NMR at our in-house quality control division. Typical particle sizes fall between 20 and 60 mesh, tailored for rapid dissolution and reactivity, but we offer finer or coarser grades for those who work with different automation standards. Appearance matters when it comes to water-white or faintly yellow crystals, the kind you recognize immediately as high-grade in any proper derivatization lab.

    Steady Results: Why Purity and Handling Matter

    Dansyl chloride isn’t an afterthought. Its reputation in protein chemistry circles comes from unmatched selectivity for amino groups, producing stable sulfonamide derivatives that show strong fluorescence under UV. You can see the difference in your chromatograms: clean separation, low background noise, and consistent signal from one run to the next. That outcome relies on our ability to control hydrolysis—minimizing the formation of dansyl sulfonic acid byproducts, especially crucial in humid environments where the reagent can degrade.

    It takes more than a specification sheet to guarantee that kind of stability. Our teams routinely run accelerated storage tests and screen each lot for shelf-life prediction. The batch that doesn’t match reference performance—no matter how close it comes—never leaves the plant. We keep moisture below 0.1% and use nitrogen-purged drums, designed for labs and manufacturing operations alike.

    If you’ve seen erratic results from imported brands or small-lot syntheses, you might blame sample prep or equipment. We’ve traced problems back to caked dansyl chloride that had absorbed water, or to inconsistent particle size that led to incomplete derivatization. Technical service calls sometimes feel like detective work—untangling storage issues, explaining why clear labeling and dry, cool storage matter. In practice, choosing a batch-tested product means spending less time on re-runs and more on real analysis.

    How We Control Quality at Source

    From raw material sourcing to post-synthesis milling, our teams drive each operator to check actual mixing temperatures, pressure deviations, and solvent clarity. Every lot’s impurity profile draws on over a decade of analytical data, giving us signatures for known synthetic byproducts. With NMR, we monitor for off-target chlorination or misplaced substitution, because any variation can crop up when suppliers cut corners. QC staff pull sampling in duplicate. A sample that fails spectral purity on LC/MS gets flagged, quarantined, then traced back to causes—we rely on these cross-checks because no market can absorb unpredictability in a fine chemical.

    Those extra steps slow output compared to bulk commodity suppliers. Still, we know from feedback that downstream applications—especially in peptide synthesis and sensitive analytical work—demand that the product’s reactivity falls within a narrow, repeatable window. Many years ago, we shipped an order with slightly lower fluorescence intensity reported on the COA. Clients returned to us the following year, after trying different sources, because our controls delivered more consistent signals. That lesson returned when we partnered on a pharmaceutical assay where each error meant additional animal studies. “Good enough” is not good enough in this corner of chemistry.

    Applications Shaped by Factory Decisions

    Experts in protein sequencing recognize dansyl chloride for its role in the classic Edman degradation—derivatizing terminal amino acids for UV-based detection or mass spec analysis. Mid-scale users on peptide mapping or allergen detection projects might dismiss the importance of batch-to-batch consistency until an unexplained outlier disrupts a weeks-long study. Our experience with instrumentation companies taught us that autosamplers can clog when faced with sticky, non-uniform reagents, so we adjusted both drying and sieving cycles for optimal flow.

    The same holds true for bioprocess monitoring, where trace glycine, serine, or lysine quantitation makes or breaks a process validation. Shoddy reagents give hazy peaks and inconsistent baselines, complicating review by regulatory auditors. We’ve seen customers recover productivity simply by switching to material that dissolved on contact, without swirling or filtration. In libraries assembling new fluorescent probes or labeling oligonucleotides, dansyl chloride from our production line gives quick coupling and predictable emission spectra.

    Differences From Other Derivatization Reagents

    Some still ask why not switch to OPA or FMOC-CL, especially for HPLC work. Both have their place: OPA runs at neutral pH but needs an auxiliary thiol—good for speed, less robust against trace contaminants. FMOC-CL gives strong signals and operates at room temperature; its byproducts, though, can interfere with certain aromatic amino acids. Dansyl chloride produces highly stable derivatives and survives acidic and basic conditions, so the downstream analysis remains robust to clean-up steps.

    Manufacturers sometimes claim “equivalent purity” for their batches, but anyone running large-scale analytical platforms like LC-fluorometers or automated amino acid analyzers knows the pitfalls of generic material: non-specific background peaks, slower labeling, variability in retention times. In working closely with instrument OEMs, pharmaceutical developers, and food testing labs, we picked up where trade intermediaries usually fall short. Years of side-by-side sample trials taught us which lot identifiers really match application-specific tolerances—and which batches warrant containment and retesting, rather than rebranding.

    Managing the Challenges of Scale

    On a practical level, making dansyl chloride at the scale the market demands presents constant risk of contamination—from trace moisture in solvents to inconsistent precursor supply. We operate closed-loop nitrogen lines and automatic sensors to log every exposure incident in production and packing lines. We rarely see actual process deviations, but our change logs document corrective actions—from switching drum liners to recalibrating mills. These traceable investments have proved worthwhile every time a customer calls with a question about a chromatogram or a sudden shift in product reactivity.

    Large-scale customers once struggled with labeling inconsistencies; barcoding tracks every lot back through production dates, NMR logs, and raw material orders. During a major instrument launch with a global OEM, we worked side by side with their test teams for weeks, cross-matching our QC sheets with their chromatograms. Matching performance, rather than just meeting a stated purity, kept instrument variability in check and maintained product reliability as their workflows scaled to thousands of batches.

    Perspectives on Raw Material Sourcing and Supply Security

    Tight global supply chains began years before headlines made it news. Aniline and sulfonyl chloride sources have varied over the decades—small plant closures, rising regulatory hurdles, and environmental controls mark production outside a few established corridors. We manage risk by qualifying multiple suppliers and keeping redundancy in process steps such as distillation and precipitation. Internal benchmarks, not just third-party audits, guide supplier retention because outsourced verification can’t predict all in-process fluctuations.

    Some clients today look for reassurance on product origin and transportation climate. Our drums get layered with desiccant wraps and dual-bagged when shipped to tropical ports, a lesson learned from early failures. We monitor not just the purity on leaving our warehouse, but stability on arrival after shipping across multiple climate zones. Lab contacts in Southeast Asia first drew our attention to hydrolysis rates in damp environments; since then, we send follow-up test kits for critical applications and adjust logistics when seasonal humidity spikes.

    How Fine Chemical Manufacturing Differs From Trading

    Day-to-day, our operation runs differently from trading houses or independent resellers. Bulk traders can offer shorter lead times or sharper pricing, but rarely do they control the entire synthesis, drying, quality control, and packaging chain. They might not have the centuries-old analytic records that let us predict shelf stability, or knowledge of regulatory contaminants down to sub-ppb levels. The skills to make high-purity dansyl chloride translate into real results, especially for users tracking trace allergens in pharmaceutical runs or resolving background peaks in complex matrices.

    Manufacturing in-house brings direct feedback into process improvements. A complaint on reactivity—say, sub-optimal fluorophore yields in mass spec work—feeds straight to our chemical engineers, who adjust synthesis parameters and drive upstream conversations with raw material providers. Tracking every finished drum and feedstock container builds experience that purely distribution-based companies rarely accumulate. Some labs work with low-cost alternatives in simple, single-use applications, but nearly everyone with ambitious, high-sensitivity work returns to a supplier who can explain not just what the COA says, but why it matters, and how each lot will behave in the field.

    Mitigating Risks in Customer Workflows

    Technical teams at pharmaceutical and academia labs often share stories of batch failures linked to variability in derivatization chemistry. In one case, we traced a cyclic lot deviation to minor shifts in reactor temperature during summer, a change that escaped typical “on-paper” audits but showed up in fluorescence quantum yields. These small but significant lessons weeded out hidden costs—failed runs, failed validations, and regulatory headaches—downstream from what might seem a minor impurity spike or moisture drift.

    Training isn’t always about showing off internal process maps or QC graphs—it extends to customer calls where teams look for troubleshooting, not just replacement shipments. We’ve built application notes that detail how to spot early warning signs: slower reagent dissolution, color drift upon opening, or unexpected reaction times. We encourage larger labs to validate new lots against historical baseline, and to blend drums for high-throughput work. Our direct support on these problems doesn’t end after shipping—the partnership grows as workflows evolve and new analytical requirements emerge.

    Consistency Over “Spec Sheet” Marketing

    Many suppliers tout absolute purity as the main draw. With dansyl chloride, this only scratches the surface. Analytical consistency matters just as much—a fact recognized by any lab running repeated protein or peptide workflows. For example, two lots meeting the same 99% HPLC spec can show differing results in actual coupling yields or instrument background. That’s why we put as much attention on process trends, not just end-point metrics.

    Over hundreds of product release cycles, experience confirmed that even tiny shifts in synthesis or drying—different condenser flow rates, slightly wetter solvent, older glassware—can alter reactivity. We treat the tracking and analysis of those shifts as a core manufacturing responsibility. Many generic products, especially those passing through trading intermediaries, skip this layer of documentation, treating end users as “specification absorbers” rather than technical partners.

    Mistakes made in upstream control become visible eventually: higher variance in sample throughput, inconsistent probe labeling, delays in validation studies, or extra noise on trace analysis. We accept that complete elimination of undesired side products proves impossible in any real-world plant; our job stays focused on detection, elimination, and—when needed—open communication so that users can work around the limitation or draw from alternate batches.

    Continuing Innovation in Analytical and Diagnostic Use

    Growth of peptide therapeutics, immunoassay development, and high-throughput analytical techniques pushes ever tighter requirements on reagent batches. We keep building detection tools into our workflows—using extended mass spec libraries, updating NMR databases, adding inline particle-size metrics—to anticipate shifts that would escape historical test panels. Years ago, we shipped dansyl chloride intended for basic amino assays, only to see the same lot repurposed in clinical proteomics or food allergen research under new robustness requirements. Feedback from these broad applications cycles back to upstream process adjustments.

    Each new analytical frontier—single-cell proteomics, large-molecule drug characterization, or trace food contaminant tracking—asks for refinements that outsiders might not notice. So we focus internal investment on process flexibility, sensorizing aging equipment, and rapid root-cause analysis for every support ticket that hints at chemistry drift. Complex supply and demand signals can never be preempted perfectly, but looped direct feedback into both synthetic and QC teams makes us more agile in meeting evolving user expectations.

    Comparing Performance With “Standard” Brands

    We regularly test our output against widely recognized commercial materials. Side-by-side trials in GC-MS or in post-column HPLC derivatization highlight batch phenomena: how some vendor’s lots dissolve sluggishly or leave excessive residue, resulting in more instrument downtime. In synthetic biology workflows, certain low-cost lots show cross-reactivity with lysine derivatives, clouding downstream signal clarity. Labs running time-sensitive diagnostics value the near-instant dissolution and consistent peak intensity from high-grade lots that do not fluctuate cycle to cycle.

    One strength in direct manufacturing comes from immediate course correction: process drift leads straight to plan adjustments, product holds, or revalidation. Where others might pass along a questionable lot and defer to “brand” reputation, our philosophy calls for direct communication and, if warranted, temporary supply suspension. That trust translates to real-world productivity: labs experience fewer reruns, fewer surprises, and more confidence to expand applications on the platform.

    Looking Forward: Balancing Reliability, Scale, and Environmental Care

    As demand for proteomics and peptide therapeutics grows, responsible chemical manufacturing faces pressure to ramp up output without compromising quality. Regulations and market standards scrutinize our entire lifecycle—from raw material sourcing to emissions and waste handling. Over the past decade, incremental investments in closed-circuit synthesis, waste recovery, and solvent recycling cut production losses and offer both cost and environmental benefits. Each improvement shows up months later as more stable batch quality, lower fluctuation in key impurity profiles, and fewer energy spikes in plant operation logs.

    We keep expanding data-driven approaches—digitizing process records, deploying inline impurity sensors, rotating plant teams across inspection points—to spot and contain issues where they start. Customers rarely see these internal moves directly, but the cumulative effect is measurable: greater batch predictability, swifter root-cause investigation for outlier results, and a steady record of performance across global shipping routes. Industry partners, regulatory agencies, and end-users each set unique standards, but shared commitment to open traceability and data transparency ties these demands together.

    Dansyl chloride’s value goes beyond numbers on a product sheet. Direct, transparent manufacturing—built on decades of process knowledge, analysis, and ongoing improvement—matters most for users facing challenges at the frontlines of analytical science. Our efforts ensure that pioneers in proteomics, therapeutic peptide design, and high-throughput food analysis can focus on research and innovation, confident that the reagents in their workflows bring clarity, not uncertainty.