HS Code |
439972 |
| Product Name | Dansyl Chloride (10% in Acetone) |
| Chemical Formula | C12H12ClNO2S |
| Concentration | 10% w/v |
| Solvent | Acetone |
| Appearance | Clear, yellowish solution |
| Molecular Weight | 249.75 g/mol (Dansyl chloride) |
| Cas Number | 605-65-2 (Dansyl chloride) |
| Boiling Point Acetone | 56 °C |
| Storage Temperature | 2–8 °C (refrigerated) |
| Light Sensitivity | Sensitive, protect from light |
| Application | Amino acid and peptide labeling |
| Flammability | Highly flammable (due to acetone) |
| Synonyms | 5-(Dimethylamino)naphthalene-1-sulfonyl chloride |
| Hazard Classification | Irritant, flammable |
| Density | 0.79 g/mL (acetone) |
As an accredited Dansyl Chloride (10% in Acetone) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma-Aldrich's Dansyl Chloride (10% in Acetone), 25 mL, packaged in an amber glass bottle with hazard labeling and secure cap. |
| Shipping | Dansyl Chloride (10% in Acetone) is classified as a hazardous material due to its flammability and toxicity. Shipping requires compliance with international regulations (IATA, DOT). It must be packaged in UN-approved containers, labeled appropriately, and shipped by certified carriers specializing in chemical transport. Temperature and handling instructions must be strictly observed. |
| Storage | Dansyl Chloride (10% in Acetone) should be stored tightly closed in a cool, dry, well-ventilated area, away from heat, sparks, and open flames. Keep container protected from light and moisture. Use only chemical-grade containers compatible with acetone. Store separately from incompatible materials such as strong oxidizers and bases. Ensure storage area has appropriate spill containment and safety signage. |
Competitive Dansyl Chloride (10% in Acetone) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
From direct experience working at the intersection of production, quality, and research, there’s a story behind every chemical blend. Dansyl Chloride (10% in Acetone) isn’t just another niche reagent; it has shown consistent value in analytical and synthesis work, especially for researchers who care about selective and strong fluorescent labeling. The combination we deliver—10% Dansyl Chloride precisely dissolved in high-purity acetone—reflects years of listening to chemists and life scientists who demand quality and ease of use over the long haul.
Dansyl Chloride serves as a widely respected derivatizing agent, touching disciplines from proteomics to pharmaceutical analytics. In its essence, this sulfonyl chloride bonds efficiently to primary and secondary amines, forming sulfonamide derivatives. The beauty of this transformation is the distinct fluorescence it imparts, providing visibility and sensitivity that plain detection methods sometimes lack. Our preparation, 10% Dansyl Chloride in acetone, aims to streamline workflows. Freshly prepared, filtered, and sealed, it minimizes the hassle and potential losses that come with manual weighing and dissolving in the lab.
Reflecting on how labs run, we know most teams prefer opening one bottle and getting right to work. We produce the solution under tightly controlled conditions. That delivers consistency—bottle to bottle, year to year—eliminating the annoying batch-to-batch variability that can upset method validation efforts. Because our own R&D and quality teams rely on this exact stock, we make sure it checks every box for solubility, concentration, and background purity before it gets to anyone else.
Dansyl Chloride itself isn’t freely soluble in water or many weaker solvents. Acetone, with its rapid evaporation and compatibility with many downstream applications, offers a practical vehicle. A 10% concentration ranks among the most demanded for labeling: strong enough for high reactivity, yet not so concentrated as to cause miscibility or precipitation headaches. We tested different ratios based on user feedback, and found 10% to offer the best balance of storage stability and reactivity for both rapid analytical labeling and preparative organic synthesis.
Labs running protein or peptide derivatization rarely have time for mixing dry powders. Acetone dissolves the reagent thoroughly—no waiting for limpid solutions, no scraping undissolved crystals. That means faster reactions when labeling amino acids, peptides, and other amine-containing compounds, which is how most researchers end up using this product. In chromatography or mass spec work, that speed pays dividends in both throughput and reproducibility.
Our team stands behind Dansyl Chloride (10% in Acetone) because we know first-hand the headaches that untidy stock solutions cause—hydrolysis, precipitation, poor chromatographic performance. Each batch undergoes rigorous in-house validation using both HPLC and UV-fluorescence techniques. That isn’t just a regulatory step; it’s a safety net for researchers. In hands-on practice, that helps ensure labeled products shine under UV, with consistent intensity and peak purity. This is critical when quantifying micromolar amino acids in clinical samples, or when mapping post-translational modifications in proteins.
Researchers in metabolite tracing or amino acid analysis benefit from our solution’s reliability. Using precise in-line injection methods for HPLC or capillary electrophoresis, you gain peace of mind knowing every aliquot matches the calibration runs that underpin your results. Beyond method validation, daily usage in actual analytical methods—tracking lysine derivatization in food quality testing or looking for contaminants in clinical research—reinforces how much time a pre-made Dansyl Chloride solution can save.
It’s common to find Dansyl Chloride supplied as either a crystalline solid or at various concentrations in less compatible solvents. Through years of field feedback, we’ve seen the difference first-hand. Dry Dansyl Chloride, while shelf-stable, forces users into extra preparation: weighing, dissolving, filtering, all under precise moisture control. That can introduce variability, and for some users, the reagent may even degrade before application, especially when humidity creeps into a busy lab environment.
We’ve also trialed other solvents as part of side-by-side studies, including acetonitrile, DCM, and ethyl acetate. Each brings its own limitations. Acetone is broadly tolerated in most peptide and small-molecule workflows; it evaporates rapidly after use, leaving little chance for interference. In contrast, acetonitrile solutions sometimes show poorer shelf stability, and DCM raises safety and regulatory issues in many labs. By sticking to 10% in acetone, we offer a ready-to-use solution that’s compatible with key analytical and synthetic setups, from fast HPLC loading to manual plate-based fluorometric assays.
Dansyl Chloride, by nature, reacts with moisture and amines in the atmosphere, degrading over time. Our solution comes stabilized in amber glass, inert-atmosphere packaging, so whether the bottle sits in a -20°C freezer or sees weekly rotation in a clinical lab, it stands up to real-world abuse. We’ve spent considerable effort on reducing particulate and contaminant levels, which often trouble downstream results in high-sensitivity methods. This low-particulate approach didn’t just come from reading spec sheets; it came from years of troubleshooting trace impurities in HPLC and LC-MS results.
Customers report back to us with fewer instances of reagent-induced baseline drift or spurious peaks during chromatography. For high-throughput clinical, food safety, and environmental labs, these little sources of trouble create unnecessary repeat work. Fewer unexpected results translate into higher lab productivity—a lesson we learned the hard way, one quality check at a time.
Dansyl Chloride finds its strongest following among academic, biotech, pharmaceutical, and food safety labs. In practice, it sees action from undergraduate teaching settings to major contract research organizations. By providing it ready-blended at 10% in acetone, we see our product enabling routine labeling of amino acids in high-throughput screening as well as more sophisticated proteomic studies needing precise post-translational modification mapping. More than once, we’ve collaborated with researchers optimizing peptide mapping protocols; direct supply of consistent reagent batches has underpinned reproducible, defendable results.
Beyond proteins and peptides, Dansyl Chloride punches above its weight in environmental monitoring—helping quantify trace amine contaminants in water, foods, and drug samples. Because the fluorescence yielded is both strong and selective, labs can push quantitation limits lower than what’s possible with most competing derivatizing agents. For instance, in food safety, clarity and speed in detecting biogenic amines matter for both compliance and public health. Our ready-to-use solution bridges that gap, supporting these evolving real-world demands.
From a manufacturer’s perspective, transparency and traceability are non-negotiables. We document each batch—raw material sourcing, blending, and filling—so researchers can trust what’s in each vial. Our team sticks with acetone sourced from certified suppliers, ensuring minimal water and impurity levels. Each batch of Dansyl Chloride passes identity and purity checkpoints, confirmed by both NMR and HPLC. And as we rely on this same product internally for our own process controls, that traceable record gives our staff and customers peace of mind.
From the QC lab to the production line, we’ve found the greatest gains in long-term reliability don’t come from chasing spec sheets but from putting real samples through real-world stress tests. Aging studies, freeze-thaw cycles, and prolonged bench exposure all factor into our stability claims—not just storage instructions buried in a manual. Over the past decade, minor refinements in our sealing and handling practices have cut down customer complaints around stability and particulate load.
Dansyl Chloride has an irritant nature, so direct contact and inhalation are risks we take seriously inside the plant and for downstream users. Our in-house training reinforces proper handling, labeling, and emergency response—for all staff and via prominent hazard labeling. In supplying our 10% acetone solution, we prioritize securely capped, amber-glass bottles with tamper-evident seals. Experience shows this packaging best preserves both the chemical and the peace of mind, especially for institutions running large batchwork or recurring classes.
Rather than pushing higher concentrations or economical plastic containers, we stay with the format that demonstrates the most reliability, minimizing accidental exposure. Through supplier audits and our own in-house feedback channels, we keep up with safety recommendations both domestically and worldwide. Regular engagement with client EH&S officers over the years taught us how subtle packaging variations and clear documentation make a difference for frontline lab and warehouse workers.
Not all labs use the same labeling methods or have equal equipment. Our 10% acetone stock fits hand pipetting, autosampler, microplate, and robotic workflows alike—lab teams with automated liquid handlers or those working at the benchtop with Eppendorf tubes. By standardizing at a concentration that aligns with many published protocols, transitions remain smooth, no matter whether a workflow scales up for a screening project or down for a core research question. The transparent lot-specific documentation means robots can receive the same level of care in data tracking as manual operators.
We’ve equipped contract manufacturers and CROs running parallel projects with our acetone solution, supporting unmet throughput needs. Bottled at scale with automated filling lines, each bottle undergoes randomized sampling, checked by mass-based verification to eliminate minor volumetric surprises. The product’s track record for pipettable viscosity and non-clogging behaviour reflects deep back-and-forth between our process teams and pilot lab customers.
Every new graduate student or research associate faces the daunting task of unfamiliar reagents and tricky lab prep. Dansyl Chloride (10% in Acetone) removes many barriers, letting users focus on experimental design, not chemical pre-work. Feedback from teaching labs points to fewer broken glassware incidents and wasted time, a win both for student safety and instructor workload. In the industrial setting, this same simplicity reduces onboarding time and minimizes mix-ups in multi-shift or high-turnover environments.
Because we supply the same solution across research, industrial, and highly regulated environments, the format has built a reputation for robust, cross-application friendliness. Time saved on prep and repeatability means more energy spent on actual experimentation and troubleshooting—the parts of science that drive meaningful results, not just data entry. In our experience, those repeat lab customers who started as students or junior scientists often become advocates, recommending the same solution as they move on to lead roles elsewhere.
A producer doesn’t just fill bottles; responsibility covers the footprint left behind. While acetone is one of the more manageable solvents environmentally, any chemical process deserves scrutiny. Over years of scale-up, we invested in closed-loop acetone recovery, reducing raw material wastage and lowering emissions during blending. That hasn’t just helped our bottom line, it matters practically when labs audit our sustainability efforts or look for partners who can demonstrate greener practices for grant and compliance documents.
Inside our planning group, ongoing dialogue with research partners and upstream suppliers highlights emerging regulatory and application trends. We’ve responded by continuing to phase out non-recyclable packaging and reduce the weight of glass and cap materials. Minor improvements, like low-profile closures or lot-specific QR codes for paperless traceability, have crept into our packaging—changes usually driven by questions and practical suggestions from the same lab teams that rely on our product for day-to-day labeling.
Manufacturing isn’t just about what comes off a line; it’s about relationships. Through open feedback channels, site visits, and pilot program support, our team hears first-hand where Dansyl Chloride (10% in Acetone) excels and where it could go further. Some research labs need bulk batches with shelf lives tuned for quarterly use. Others want micro-volume packaging for ultra-fine work. In response, we tailor bottle sizes and run stability tests based on actual storage and usage patterns, not just ballpark industry guesses.
Collaboration with users has spurred us to provide more detailed certificate of analysis content—adding performance data such as fluorescence intensity under standard labeling conditions. This kind of direct information, rooted in real-lab requests rather than top-down marketing, builds trust across a buyer’s journey, whether they’re qualifying a new vendor or seeking validation for a compliance audit.
Bringing Dansyl Chloride (10% in Acetone) to market hasn’t followed a linear path. Experience matters—the lessons learned from tracking stability slips during hot summers, identifying microscopic contaminants in QC analysis, and revising operational SOPs to tighten capping procedures. Addressing each issue, we’ve built up an internal knowledge base that translates to a more reliable bottle in researchers’ hands.
Real-world application drives our process changes. When university labs needed more resilient bottles for field collection, we adjusted glass thickness and shipping methods. In response to pharmaceutical clients looking for maximal batch consistency across distributed sites, we introduced larger batch blending and extra in-process analytics. All these tweaks translate to fewer headaches, clearer data, and simpler workflows for the chemists using our solution day in and day out.
Dansyl Chloride (10% in Acetone) represents more than a line on a catalog—it’s an evolution that parallels decades of practical experience, fine-tuned by the scientists and technicians who rely on it daily. As a chemical manufacturer, we approach each batch as both producer and user. Our own teams use this solution in routine projects ranging from protein quantitation to novel fluorometric assay development. Each improvement reflects the thousands of bench hours our customers (and staff) invest in making research happen, and in our hands, every bottle shipped is a small but meaningful step in making that work easier, faster, and more reliable.