West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Cyclohexane [for HPLC Solvent]

    • Product Name Cyclohexane [for HPLC Solvent]
    • Alias Hexahydrobenzene
    • Einecs 203-806-2
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    831802

    Product Name Cyclohexane [for HPLC Solvent]
    Chemical Formula C6H12
    Molecular Weight 84.16 g/mol
    Cas Number 110-82-7
    Purity ≥99.9%
    Appearance Clear colorless liquid
    Boiling Point 80.7 °C
    Melting Point 6.5 °C
    Density 0.778 g/mL at 20 °C
    Refractive Index n20/D 1.4265
    Flash Point -20 °C (closed cup)
    Vapor Pressure 97 mmHg at 25 °C
    Solubility In Water Insoluble
    Uv Cutoff 255 nm

    As an accredited Cyclohexane [for HPLC Solvent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 1-liter amber glass bottle with secure screw cap, labeled “Cyclohexane [for HPLC Solvent],” Sigma-Aldrich, high-purity chemical grade.
    Shipping Cyclohexane [for HPLC Solvent] (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in sealed, chemical-resistant containers to ensure purity and prevent contamination. Packages comply with hazardous material regulations, featuring clear labeling and appropriate documentation. Shipping includes secondary containment and cushioning to minimize risk during transport, maintaining solvent integrity for laboratory use.
    Storage Cyclohexane [for HPLC Solvent] should be stored in a cool, well-ventilated, and dry area, away from direct sunlight and sources of ignition. Keep the container tightly closed, and protect it from physical damage and moisture. Avoid storing near oxidizing agents, acids, or heat. Store at temperatures recommended by the manufacturer, typically below 30°C, and ensure proper chemical labeling.
    Free Quote

    Competitive Cyclohexane [for HPLC Solvent] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Cyclohexane for HPLC Solvent Use

    Meeting the Demands of Precision HPLC

    Producing cyclohexane for HPLC solvent applications means facing constant scrutiny where purity, consistency, and traceability matter more than anything else. High-performance liquid chromatography puts tremendous demand on every component poured into the column. Lab teams can trace faulty baselines and ghost peaks to minute impurities in solvents. It doesn’t take much for water content, peroxides, or residual aromatics to undermine an entire analytical run. That’s why our manufacturing team pays such close attention to every step, from choice of raw materials through final bottling.

    We draw from decades of experience processing hydrocarbons destined for the highest-purity market slices. Cyclohexane intended for HPLC solvent use undergoes repeated distillation at our facility, combined with modern purification steps that drive contaminant levels far beneath the requirements for standard laboratory reagents. Each lot not only meets minimum standards for evaporative residue, UV absorbance, and fluorescence background, but also shows tight batch-to-batch reproducibility.

    Quality You Can Trust in Critical Applications

    There is nothing theoretical about the performance stakes. Whether the HPLC system submits to food quality control, pharmaceutical investigation, or trace environmental testing, the detection limits shrink every year. Our workforce saw the days when certain non-polar solvents, chosen solely to carry analytes with limited polarity, never came close to today's standards regarding purity or chromatographic background. Contemporary cyclohexane for HPLC must outperform those historic options on every metric that matters: chemical purity, optical clarity, fluorescence baseline, and non-volatile residue.

    Our plant takes on a continuous improvement mindset. Every process checkpoint, from hydrogenation reactor control to vacuum distillation final cuts, gets cross-checked by an independent team reporting directly to our quality group. Instrument calibration and system suitability follow strict SOPs. Each batch enters HPLC and GC assays for aromatic residue, polar contaminant, water content, and metallic trace analysis. Production chemistry teams do not rely on supplier certificates – every impurity profile gets re-confirmed in-house before product is cleared for bottling.

    The Model and Practical Advantages

    For customers, product specification numbers speak clearly. We maintain a popular model manufactured with GC-grade cyclohexane as a starting stock, then further polish in proprietary distillation streams. Minimum purity achieves 99.99% by gas chromatography, with water and oxidized residues below 10 ppm. This matches the recommendations for solvent front clarity and baseline stability on modern photodiode array and fluorescence detectors. It is not enough to hit the numbers—our team tracks lot consistency by running parallel chromatograms from multiple plant lines and batch numbers.

    Direct manufacturing control lets us react to issues in real time. Internal lab teams work beside operations, tracking even seasonal feedstock variations so that nothing unexpected slips through. Tight control of final filtration ensures removal of copper, iron, and all other transition metals that might catalyze peroxide formation or create baseline drift. We refuse to let material with trace-byproducts like cyclohexene, benzene, or methyl-cyclohexane leave the facility. Any hint of those aromatics gets flagged and re-processed.

    This type of dedication sets genuine solvent manufacturers apart from resellers or traders. Traders re-bottle, but cannot guarantee the journey between refineries, storage tanks, or container transfers—critical when microgram contamination will ruin a run. End users call us directly for clarification, batch records, or data on UV spectrum transparency. We design our process so each bottle delivered has full backward traceability to the precise fractional distillation cut. If any chromatography baseline artifact does appear, our support staff has real-time access to batch quality logs, not stale paperwork from a third party.

    At the Heart of Daily Laboratory Work

    Technicians, researchers, and analysts do not care for marketing hyperbole. They want a solvent that allows the method’s own noise floor to come forward, not the contamination noise of a poorly manufactured solvent. Daily tasks rely on solvent not being the weak link. In practice, our customers report their detector backgrounds drop by measurable degrees, with fewer solvent artifacts—and far less baseline drift across gradient runs. Many users switching from ACS-grade or unrefined cyclohexane see significant improvements, especially when working at sensitive wavelengths below 210 nm.

    There are important, real-world differences between our HPLC-grade cyclohexane and lesser grades. Lower-purity cyclohexane often carries enough aromatic or heteroatomic contaminants to cause trouble. Many producers fail to fully remove peroxides or higher-boiling distillation tails. Common technical grades show strong UV absorbance below 220 nm, masking or distorting true analyte signal. Our rigorous post-distillation clean-up, including filtration over activated alumina and final microfiltration through sub-micron filters, sharply limits these impurities. The outcome is a reliable, near-zero background when solvent front elutes in a reverse-phase or normal-phase HPLC method.

    For those running HPLC regularly, these differences are not academic. Maintenance teams appreciate the way our ultra-pure solvent protects expensive injection valves, column beds, and detector optics. Fewer system blockages, less frequent need to purge lines or change filters, and extended column life save direct costs long after the solvent leaves our loading dock.

    Supporting Data Integrity and Lab Compliance

    Direct-to-lab supply lets us support not just performance, but regulatory and quality compliance. Our teams prepare full impurity documentation, including typical chromatograms of supplied lots, scan and purity certificates, and traceability records stretching back to raw hydrocarbon feed. Compliance inspectors, auditors, and research directors call on us to provide archived test results for each shipment, not generic spec sheets. Such diligence supports everything from GMP applications in pharma labs to fully traceable method validation work in compliance testing labs.

    Confidence in results grows from a solvent vendor who controls both upstream and downstream processes. We never dilute the focus by splitting attention among dozens of unrelated chemicals. The cyclohexane solvent line sits at the core of our hydrocarbon purification business. Every operator follows a transparent protocol with dual signoff for bottling, documentation, and storage conditions. Every recall, even upstream transportation issues, gain rapid response since there are never layers of middlemen between our production floor and the end user’s bench. Technical support is a matter of daily duty, not a ticket system run by marketing generalists.

    Handling, Storage, and Safety Experience

    Handling large batches of high-purity cyclohexane every day builds an institutional safety culture that benefits laboratory users. Flammability, potential for peroxide formation, and solvent losses during transfer or bottling all require precise controls. Our team continuously reviews engineering safeguards, inert atmosphere transfer methods, and explosion-proof filling stations. This expertise, gained from working face-to-face with the risks, filters down to smaller customers. Shipping protocols are never an afterthought; our direct support includes staff trained to answer practical questions on inert gas blanketing, recommended container types, and long-term storage protocols. Customers frequently consult us about minimizing peroxide build-up and safe solvent evaporation practices.

    Because we own the full lifecycle, our operation pre-qualifies container types and seals by real-world leakage testing, not just theoretical compatibility charts. This level of experience is rarely matched by repackagers or brokers. If an end user needs guidance on storing HPLC solvents, preparing clean dispensing methods, or extending shelf life, our technical team draws from direct, hard-won experience, not bullet-point guidelines.

    Comparing With Generic and Low-Grade Options

    Generic laboratory-grade cyclohexane, often sold through brokers or high-volume distributors, tends to fall short for demanding HPLC users. In fast-moving commercial supply chains, dozens of product codes often refer to pooled lots pulled from multiple refineries. These may pass basic visual inspection, but subtle contaminants like sulfur-containing molecules, oxygenates, and trace aromatics remain at levels that won’t trouble a colorimetric test but rapidly show up on an HPLC chromatogram. Such inconsistencies make data less reliable for both method development and trace analysis.

    Lab managers often approach us after having chased unexplained peaks or noisy baselines for months. “Solvent background” gets blamed, but only a manufacturing-focused quality system can drive down those backgrounds to practical invisibility. Labs discover over and over that investing in HPLC-specific solvent grade eliminates troubleshooting circles and gets the most from their chromatographic hardware. The difference comes from meticulous distillation and purification, not just stricter certificate paperwork.

    There is an ongoing temptation in procurement departments to treat solvent as a commodity, focusing on price rather than background criticality. Too often, cost-driven choices lead to expensive batch failures, column replacements, or inconclusive method validation. Our longtime industrial and research buyers confirm that investing in tightly specified HPLC cyclohexane pays for itself through uptime, reliability, and tracked data integrity.

    Continuous Feedback and Process Evolution

    Close work with HPLC practitioners in real labs lets us respond quickly to emerging analytical trends. Several years ago, our analytical chemists noticed customers shifting to lower UV detection wavelengths, pushing solvent specifications to new extremes. This challenge drove us to upgrade both distillation cut precision and final polishing steps. Feedback cycles between production, QC, and end labs serve as a continuous improvement loop—something that is simply impossible for companies that play in third-party distribution alone.

    Transparent feedback also works in the customer’s favor. We don’t hide from rejects or out-of-spec issues; batch anomalies get investigated on a process level and shared with affected customers in detail. If impurities ever approach threshold levels, we alert downstream users with advanced notice—not as a sales tactic, but as a matter of shared trust between manufacturer and laboratory. Such partnership improves both our product and the customer’s research environment.

    Beyond the Laboratory—Supporting Scalable Research

    Academic labs and startup R&D groups often begin with off-the-shelf chemicals before unexpected analytical problems force a re-examination of solvent quality. We routinely help groups scale up from small flask runs to larger semi-pilot scale projects, tailoring supplied container sizes and secondary documentation to support scale-up. There is deep satisfaction seeing academic teams transition to industry, already equipped with robust, disturbance-free HPLC data supported by our consistent supply chain. Biopharma, specialty polymer, and fine chemical sectors all rely on accurate analysis at the mg/L or µg/L level, which directly depends on background-free solvent.

    Those working on environmental trace detection—such as pesticides or industrial pollutants at ppt or ppb levels—report that consistent solvent background can literally mean the difference between regulatory compliance and failed audits. Our cyclohexane delivers near-zero background at these extreme detection limits, supporting both accredited labs and those building new protocols.

    Deliberate Focus: Cyclohexane’s Role in Non-Polar Separations

    Not all HPLC solvent requirements are created equal. Cyclohexane finds its role especially in non-polar analyte separations, normal-phase chromatography, and preparative HPLC where low solvent viscosity and high volatility streamline post-run analysis. The difference between HPLC-grade and “pure technical” cyclohexane on a separation run is obvious to those who run parallel columns or cross-validate results. High-purity cyclohexane enables sharp, easily interpreted separations, critical when target molecules are obscured by broad baseline noise or carryover peaks from earlier runs using generic solvents.

    No solvent is truly “one size fits all.” Cyclohexane HPLC solvent lines complement our offerings of hexane, heptane, and other alkane solvents. Experienced researchers know that method development becomes smoother with predictably clean baselines and clear UV transparency at all relevant wavelengths. As the manufacturer, we know exactly what residue, if any, lies behind every bottle, supporting users in choosing the right solvent mix for their analytical protocol.

    Choosing HPLC-grade cyclohexane opens up more reliable, interpretable data. The plant team stands behind every lot, supporting the science, not just filling an order.