West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Chloroform-d (containing 1wt% TMS) 99.6atom%D (stabilized with Silver chip)

    • Product Name Chloroform-d (containing 1wt% TMS) 99.6atom%D (stabilized with Silver chip)
    • Alias C1121
    • Einecs 213-668-5
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    114912

    Product Name Chloroform-d (containing 1wt% TMS) 99.6atom%D (stabilized with Silver chip)
    Chemical Formula CDCl3
    Molecular Weight 120.38 g/mol
    Deuterium Content 99.6 atom % D
    Tds Content 1 wt% Tetramethylsilane (TMS)
    Appearance Colorless liquid
    Boiling Point 60.6 °C
    Density 1.50 g/cm³ at 20°C
    Stabilizer Stabilized with Silver chip
    Purity High purity, suitable for NMR
    Cas Number 865-49-6
    Solubility Soluble in most organic solvents

    As an accredited Chloroform-d (containing 1wt% TMS) 99.6atom%D (stabilized with Silver chip) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Chloroform-d (99.6 atom% D, 1 wt% TMS, stabilized with silver chip) is supplied in 100 mL amber glass bottles.
    Shipping Chloroform-d (containing 1 wt% TMS, 99.6 atom% D, stabilized with Silver chip) is classified as a hazardous material for shipping. It requires UN identification, specialized packaging, and compliant labeling. Shipping is handled under strict regulations and may involve additional documentation and charges for safe transport of this chemical.
    Storage Chloroform-d (containing 1wt% TMS, 99.6 atom%D, stabilized with silver chip) should be stored in a tightly sealed amber glass bottle, in a cool, dry, and well-ventilated area away from light, heat, and incompatible materials (such as strong oxidizers). Keep refrigerated if possible. Ensure proper labeling and access only to trained personnel. Avoid moisture and ignition sources.
    Free Quote

    Competitive Chloroform-d (containing 1wt% TMS) 99.6atom%D (stabilized with Silver chip) prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing Our High-Purity Chloroform-d (1% TMS, 99.6 atom% D, Silver-Stabilized)

    Genuine Manufacturer Perspective on a Crucial NMR Solvent

    In the chemical lab, reproducibility and clarity in NMR spectra hinge heavily on details most people outside the industry never think about: isotopic enrichment, trace impurities, solvent stabilization, and the fine calibration of reference signals. Our Chloroform-d, containing 1wt% TMS at 99.6 atom% D and stabilized with a carefully selected silver chip, addresses those nuanced considerations. Years of manufacturing specialty deuterated solvents have given us a close-up view of what makes an NMR solvent reliable—not just for a handful of spectra, but throughout an entire project, across temperatures, and with sensitive samples.

    Why Chloroform-d Matters in NMR

    NMR spectroscopists need clarity in their data. Regular chloroform, with its dominant proton signature, muddies the water for proton detection and brings unpredictability to quantitative analysis. The industry turned to deuterated chloroform (CDCl3) a long time ago because those hydrogens swap out for deuterons, dramatically reducing solvent interference in both 1H and 13C NMR. For those running reaction monitoring or characterizing tricky new materials, nothing saves time like a solvent that doesn’t pull focus from your signals of interest.

    We know purity alone doesn’t do it. High atom% D, here at 99.6%, keeps residual proton peaks down and maximizes the amount of deuterium lock signal feeding your instrument’s field stabilization. Each percentage point lower means more trouble in both integration and sensitivity—especially for researchers hunting low-concentration analytes or quantifying trace impurities. Missing spectral detail in a low D-level solvent wastes both time and costly analytes.

    The Role of TMS and Its True Importance

    Tetramethylsilane (TMS) acts as the internal reference in nearly all organic NMR. Some would argue, just spike TMS in yourself. Our experience tells a different story. The moment of transfer, the addition of trace TMS, and the risk of introducing either excess or insufficient reference compound, all create variation. With 1 wt% TMS premixed by us and checked for homogeneity during batch manufacture, every chemist starts on level ground. The consistent reference chemical shift at 0 ppm brings one less variable to your analysis, especially during series experiments or automated runs. Labs moving toward process automation often overlook just how much error creeps in with manual solvent preparation.

    Why Silver Stabilization Sets This Chloroform-d Apart

    Chloroform, by its nature, can break down. Acidic or photochemical impurities such as phosgene form over time, especially in the presence of residual acid, oxygen, or even mild light exposure. These trace contaminants corrode glassware, affect your sample’s stability, and (most commonly missed) produce extra NMR peaks or broaden your baselines. Some still stabilize with amylene or ethanol, but these organic stabilizers become another source of background signal—and sometimes show up right inside your spectrum’s critical zones.

    We opted for silver chip stabilization for two key reasons: first, silver effectively scavenges CI2, phosgene, and other reactive byproducts without itself introducing organics into your system. Second, silver doesn’t show up in proton or carbon NMR. Instrumentation teams that run routine checks on our silver-stabilized Chloroform-d consistently report clean baselines, even after months in storage. This attention to stabilization isn’t just best practice—it directly cuts down on maintenance time, increases instrument uptime, and lets research chemists stretch each ampoule further.

    Manufacturing for Consistency and Research Reliability

    We began producing large-scale deuterated chloroform nearly two decades ago, at a time when the options in the market gave chemists repeated headaches. Each batch involved a direct exchange process under anhydrous, oxygen-free conditions, closely monitored for isotopic enrichment. Years back, lower enrichment (even as little as 98 atom% D) resulted in ghost signals that appeared and reappeared, depending on the probe and sample conditions. We re-engineered our dryers and implemented cold-column chromatographic purification, a step that wiped out halogenated acid traces and let us reliably deliver 99.6 atom% D product. Purity isn’t just for marketing sheets: in quality control, impurities like trichloroethanol or residual acid will drift onto your NMR baseline over time. That slow accumulation ruins spectral reproducibility as much as any instrument malfunction.

    Packing in silver chip stabilizer, which never leaches detectable metal or adsorbs water, shows up in the test results—nearly zero change in acid or phosgene concentration even during stress testing. Every ampoule that leaves our plant passes a triple-check for isotopic content, TMS percentage, and absence of both volatiles and stabilizer byproducts. We designed these internal tests because we spent years fielding customer complaints about invisible sources of error in NMR. These weren’t academic exercises; those customers lost valuable time, and in some cases, projects were delayed.

    How We Optimize Product Formulation and Packaging

    Our operators and engineers have learned the hard way about solvent degradation and contamination—sometimes from the packaging side. Many manufacturers fill ampoules or bottles under less-than-zero oxygen, or allow barely detectable moisture levels. Even well-sealed solvents degrade if oxygen or light finds its way in. For this Chloroform-d, we adopted dark borosilicate glass and fill under pure argon to eliminate those worries. Over time, we saw that cutting corners on bottling leads to customers seeing haze, acid formation, and visible polymeric scum—none of which belong in a proper NMR lab.

    Even after transport, the silver chip holds the product stable for twelve months or more, outlasting many organo-stabilized grades that break down inside a few weeks after opening. Some competitors offer bulk packaging and urge repackaging under nitrogen; we found this approach risks undetectable moisture ingress and subsequent decomposition, so we only distribute in argon-packed ampoules or bottles. Once researchers try these ampoules, they find sample longevity much less of a guessing game.

    Comparing Our Chloroform-d to Common Alternatives

    The NMR community often uses DMSO-d6, acetone-d6, or methanol-d4 as deuterated solvents. Compared to these, Chloroform-d brings better solubility for most organic compounds and rarely overlaps with key analyte signals in the aromatic and aliphatic regions. DMSO and methanol-d4 often overpower weak signals in certain areas with water contamination or their own residual peaks. In contrast to CDCl3 grades stabilized with ethanol or amylene, we see that the silver-stabilized formulation produces consistently sharper peaks and doesn’t introduce the small, sometimes confounding triplets or singlets in crowded regions.

    Some lower-priced CDCl3 grades claim high isotopic enrichment, but don’t specify their stabilization method or skip TMS altogether. We monitor independent laboratory results showing increased acidification and color change in those products, even under proper storage. Over the years, labs switching from competitor brands to ours commonly notice a reduction in baseline wandering and “ghost peaks”—improvements that correspond directly to fewer purification byproducts and higher deuterium enrichment.

    One persistent challenge in the industry: cost pressures push some suppliers to cut enrichment or skip the stabilizer. After seeing research groups deal with doublets from protonated solvent, or sudden baseline drift in long runs, we held to enrichment and stabilization practices even as raw material prices climbed. Chemists routinely report fewer repeat runs and higher-quality data as the direct benefit.

    The Unseen Impact of Reliable Solvents on Research Programs

    An unreliable NMR solvent doesn’t just cost money; it can derail weeks of synthesis or structure confirmation. Recall an academic lab that spent a month hunting down a mysterious multiplet near 7.26 ppm, only to trace it to a poorly stabilized, low-D chloroform batch. Since then, they switched exclusively to our 99.6 atom% D, silver-stabilized stock, and the issue vanished. Industrial process labs running polymer or intermediate QC can lose far more—entire batch releases put on hold by poor spectra that hide critical chemical changes.

    Inside our own labs, we’ve run paired tests, including stress trials where we purposely stored ampoules at elevated temperatures and exposed to strong light for weeks. Even at the extremes of what would destroy most commercial solvent stocks, ours saw only minimal acid production, and the NMR background remained silent except for the standard TMS singlet. No solvent remains perfect forever, but real-world robustness beats paper specifications every time.

    For advanced NMR work, such as quantitative analyses or multipulse techniques, solvent reliability can’t be left to chance. TMS level homogeneity, exceptional atom% D, and absence of interfering stabilizers add up to smoother automation and clarity for even the lowest-level analytes. Spectroscopists who’ve worked with us over multiple grant cycles tell us that the real benefit is never needing to trace instrument drift or spectral anomalies back to the solvent.

    Practical Tips for Chemists Using Chloroform-d in Routine and Advanced NMR

    Years on the manufacturing floor and in partnership with research customers taught us key steps to maximize the performance of every ampoule. First, decanting under an inert gas keeps each pour consistent, so using argon or nitrogen blanketing makes a noticeable difference in avoiding back-contamination. Fresh glassware, free from detergent or surface-embedded water, remains essential. Take care to avoid leaving ampoules open for extended periods; atmospheric CO2 absorption can produce acidic byproducts even in the best-stabilized solvent.

    For long-running automated instruments, we advise mounting an ampoule for frequent withdrawal instead of bulk decanting—this decreases batch-to-batch variation and reduces exposure. Labs sometimes ask about filtering the silver chip; in our experience, it poses no issue to keep the silver chip in the ampoule until the last decant, and it continues to scavenge trace byproducts until the very end of the bottle’s life.

    Low-volume users need to consider evaporative loss. Chloroform boils off at a modest 61 degrees Celsius, and even minor leaks in the storage cap or septum produce loss of both solvent and TMS. We recommend using properly sealed septa and avoiding repeated puncture of ampoules, which allows for atmospheric moisture to slip in over time.

    Researchers running NMR at extremes—very dilute samples, very hygroscopic compounds, or complex matrices—frequently find that stabilizer-free or amylene-stabilized grades fail to keep the baseline quiet. Reliable silver stabilization coupled with pure TMS eliminates this risk. If baseline wander or unexpected peaks crop up, it’s almost never the silver-stabilized, 99.6 atom% D batch that’s at fault.

    Fact-Driven Manufacturing Choices Shape Better NMR Outcomes

    Behind each batch, we measure everything that matters: isotopic enrichment by mass spec, TMS by quantitative NMR, trace acid by argentometric titration, and residual water with coulometric Karl Fischer. We keep batch records stretching back ten years. Some buyers, especially institutions needing GLP or ISO tracking, appreciate the ability to pull up detailed certificate records on demand. Learning from every complaint and oddity, our manufacturing process now flags even the smallest enrichment drifts for review.

    Pharmaceutical clients push for even higher standards; their validation steps demand not just “good enough” solvents, but in-spec performance each time, down to the last milliliter in the ampoule. We’ve seen how even slight underenrichment or trace stabilizer leaks throw off quantitation for regulatory filings. We learned over time that keeping a single, consistent formulation is better for everyone in the long term—less confusion, smoother instrument operation, and fewer surprises.

    The Bigger Picture: How Solvent Quality Advances Science

    Manufacturing solvents feels routine only from the outside. For those of us making Chloroform-d with this strict quality, it’s a daily partnership with every chemist’s quest for unambiguous data. Research projects, whether basic or applied, gain efficiency and reliability when “solvent drama” becomes a memory rather than a recurring concern. The broader scientific community gains from this predictability; standardization lifts the level of the entire field. More reproducible results mean fewer false positives, less wasted effort, and a shared language of spectra across the globe.

    We have had partners on every continent feed back: clear solvent, no trace water or acid, silent baseline except for the reliable TMS reference. Some research groups say spectral confidence from our solvent gave them the edge for publications, grant renewal, and new project launches.

    Pursuing Continual Improvement

    Chemical manufacturing never stands still. We stay tuned to the latest analytical techniques—some adopted from our own R&D, others from direct customer feedback. If a new stabilizer or enrichment process would materially raise the bar, we’d put it through bench trials in-house before ever releasing it to market. We keep connected with academic labs and industrial QC teams to anticipate shifts in what the next generation of research requires.

    Supply chain focus became crucial after the past several years. Global raw material shortages and logistics hiccups forced many producers to cut back on enrichment or switch to less reliable stabilization, but we made the decision to prioritize customer outcomes, even if it sacrificed some short-term volume. Experience shows: Spectroscopists remember who delivered unambiguous spectra and who did not, and we stake our reputation on keeping the quality unwavering.

    Summary of What Sets This Chloroform-d Apart

    Our Chloroform-d, enriched to 99.6 atom% D, stabilized with silver chip, and spiked with 1 wt% TMS, is a product of engineering, customer partnership, and an uncompromising stance on quality. Every detail—from raw material sourcing, through isotopic purification, to controlled bottling—comes from years of listening to laboratory needs and constantly improving to meet them. For any chemist who wants cleaner, more confident NMR data, this formulation offers a foundation, not a variable, in their science.