HS Code |
602170 |
| Product Name | Butylamine [for HPLC] |
| Cas Number | 109-73-9 |
| Molecular Formula | C4H11N |
| Molecular Weight | 73.14 g/mol |
| Purity | ≥99.0% (GC) |
| Appearance | Clear, colorless liquid |
| Boiling Point | 77-78 °C |
| Density | 0.740 g/mL at 25 °C |
| Flash Point | 6 °C (closed cup) |
| Solubility In Water | Miscible |
| Storage Temperature | Store at room temperature |
| Synonyms | 1-Butanamine, n-Butylamine |
As an accredited Butylamine [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Butylamine [for HPLC], 99%, Sigma Aldrich, supplied in a 100 mL amber glass bottle with secure screw cap and clear labeling. |
| Shipping | Butylamine [for HPLC] is shipped in tightly sealed containers to prevent leakage and contamination. Packaging complies with safety regulations for hazardous chemicals, typically including secondary containment and appropriate labeling. It is transported under controlled conditions, ensuring protection from heat, direct sunlight, and physical damage, with all necessary shipping documentation provided. |
| Storage | Butylamine [for HPLC] (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored tightly closed in a cool, dry, well-ventilated area away from sources of ignition and incompatible substances such as acids and oxidizers. Keep container tightly sealed and properly labeled. Store at room temperature and protect from moisture and direct sunlight. Follow all safety data sheet (SDS) recommendations for safe handling and storage. |
Competitive Butylamine [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every day, our team faces the same guiding question: how do we produce butylamine that goes beyond expectations for chromatographers running HPLC systems? We don’t approach this by chasing lofty ambitions or by adding ornamental features. Our focus always returns to one thing—dependability measured at the bench, not at a desk or in a boardroom. Decades of daily synthesis and purification let us see exactly where the difference lies between an average solvent additive and a product made for people who have a hard deadline and an exact retention window to hit.
We never forget who uses this product. Scientists working with complex peptides, pharmaceutical analysts tracking trace impurities, food safety labs comparing dozens of samples in a day—they all reach for butylamine in their mobile phase when other amines leave them chasing ghosts or fighting carryover. We developed our process for HPLC butylamine to answer the countless headaches we heard about from actual chromatographers. Peaks shifting minute-by-minute, ghost signals from decomposed alkylamines, columns aging before their time. These stories pushed us to overhaul our distillation protocols, extend our purification steps, and lock in batch traceability all the way back to basic raw materials.
Nothing in chromatography comes easy when the chemical in your bottle carries unpredictable hidden UV signals, basic impurities like secondary amines, or water that throws off your mobile phase gradients. Our butylamine for HPLC isn’t just stricter—every step gets tested to eliminate drift between batches. We watch for those subtle impurities like di- and tri-butylamines, aldehydes, and even nitrosamine formation, which can creep in if vigilance drops. Each bottle offers a guarantee backed by real time spent on the line, not just checkmarks on a form.
Labs know the cost of a run cut short by contamination better than anyone else. It never makes the books, but it’s felt in late nights, repeated calibrations, and awkward explanations to supervisors. We trace this product’s quality from the original feedstock right through to final packing, using GC and HPLC checks for every impurity that chromatography labs flagged as problematic after years of experience. UV cut-off, water content, baseline noise, and pH stability—these are not marketing terms but the points that decide if a chromatographer can trust a new batch or must adjust their SOPs for the unknown.
Each bottle reflects dozens of careful adjustments. We dial in distillation temperatures to keep out higher and lower-boiling fraction contaminants. Each vessel holding butylamine is dedicated and rigorously rinsed between every batch cycle. All raw material lots are audited for amine precursor aldehyde or peroxide content, which even in parts-per-million can throw off a low-level detection method in LC-MS or LC-UV quantitation.
Small impurities stick out most when you need the flat, predictable baseline—especially for applications like peptide mapping or pharmaceutical impurity profiling. That’s why our team rejected batches that most certifications would pass. Our chromatographers check each new production lot against multiple gradient systems. If the baseline doesn’t stay where it should, we rework the batch—no shortcuts, no compromises. This philosophy keeps butylamine for HPLC in tune with what the industry quietly expects, even when those metrics exceed standard specifications.
We see a difference between butylamine labeled for general use and our HPLC line because we design the product for zero guesswork. Common industrial butylamine finds its way into rubber accelerators or surface active agents, but those grades can bring along trace amines and non-volatile byproducts that don’t matter in large-scale manufacturing. Once those compounds enter a chromatography system, though, they raise baselines, distort peaks, and cause system backpressure due to residue build-up. Small issues in reagent quality grow into full breakdowns on the analytical side—a lesson we learned while supporting clients troubleshooting methods at the late stages.
Some samples can’t be replaced, and each run represents not just a measurement but sometimes weeks of research. That high cost of failure means chromatographers need to trust that every variable in their sample preparation and mobile phase stays under control from start to finish. Water and amine impurities can nudge peak reproducibility enough to force recalibration cycles or even reruns. Butylamine for HPLC from our manufacturing line comes with certificates measured against the metrics that actual labs care about: UV absorbance at the main wavelengths used in quantification, iron content, residual peroxides, and ammonia by-product levels. Each certificate leans heavily on actual user feedback, field testimonials, and direct measurements from our control team.
Many new users come to us after trying standard reagent grades or even “HPLC suitable” alternatives. We hear real stories: Peaks that wander every week, background noise that costs precious quantitation on trace impurities. This gave us a clear direction—create a product where every batch delivers the same baseline, the same recovery, the same UV profile, and the same pH control. Only manufacturing at source, with deep, continuous feedback loops between QA, logistics, and customer support, lets us maintain this standard cycle after cycle.
We never rely on marketing speak about purity for its own sake—purity means nothing if the product’s trace residuals interfere exactly where the science meets the baseline. Our biggest advantage comes from using our own product on the same systems in our in-house labs, running peptide, nucleotide, amino acid, and small molecule separations daily. Every time a standard fails a QC check, or a baseline drifts during gradient elution, we return to production and find the root cause.
A lot of so-called “HPLC-grade” amines make it to market through packing and relabeling, their production shrouded in paperwork instead of visibility on the floor. We approach things differently, running small-lot syntheses alongside large-scale production to track lot-to-lot variation. We store batch reference samples for years so we can pull old production records and compare fading peaks from legacy columns if customers notice anything off. This hands-on history makes subtle differences visible: humidity uptake, metal leaching from reaction vessels, or trace side-products from inappropriate temperature controls. That insight, and a willingness to admit mistakes, forms the backbone of our approach.
We work in open production bays, not just in offices filled with computers. Every member of our team brings practical experience of seeing a subtle impurity signal play havoc with a month’s worth of separations. Cleaning, sealing, and storage standards are set with real-world impact at stake, and any time a single batch shows an anomaly, our line shuts down while we investigate. Chemical manufacturing for sensitive lab applications doesn’t reward shortcuts—it rewards careful, hands-on involvement and the willingness to pull product instead of sending out a questionable lot.
Direct manufacturing, without the filter of trading intermediaries, gives us the clearest look at changes in upstream chemicals—sourcing, purity variation from crude oil cracks, and anomaly batch reports from suppliers. We tighten specifications constantly based on what we see and what our chromatography partners demand. We aim for a mobile phase additive that fades into the background, not one that adds uncertainty at the point of testing. If the product veers off our standards—even just marginally—we reformulate. Our batch record archive and production logs run back years, and each test parameter gets reviewed not because regulations require it, but because we’ve seen firsthand what happens if you skip the details.
HPLC applications change fast, and five years ago no one worried much about sub-ppb lower amine impurities or exotic mobile phase requirements. Today, those details matter for anyone quantifying tiny impurity levels in active pharmaceutical ingredients or tracking pesticide metabolites. Lab conversations and failure reports always feed back to our manufacturing process. If a peptide separation needs butylamine with below-detection limit UV response at 220 nm, we alter the distillation path and QC lines to accommodate. Chatter about sticky columns and unexpected retention shifts always prompts a new investigation in our pilot plant. No two customers need exactly the same fix, but we keep a feedback pipeline that ensures any recurring complaint translates into a production change.
We partner with chromatography column makers, testing each batch on stationary phases known for tricky baseline interactions. Every new source of butylamine undergoes trial with several LC-MS and UV-based quant methods, stress-tested for carryover, and monitored for evaporative drift. This iterative method sets real control over what leaves our site. Each tweak builds certainty and trust, both at our end and in the hands of the people using our product under deadline pressure.
Chromatographers often suspect their equipment, sample prep, or solvents for nagging peak issues. But we’ve lost count of the stories where switching from industrial or low-spec reagent butylamine to our HPLC product ended months of troubleshooting overnight. A mobile phase built from high-grade, low-impurity amines resets the system and trims away hours of wasted troubleshooting. For busy labs, this reclaiming of time pays for itself many times over.
Eliminating batch-to-batch drift requires stable synthesis. We invest in dedicated reactors, close monitoring throughout distillation, and multi-stage extraction for any flagged impurity. We heat batches differently for each new season or raw material shift; changes in upstream petrochemical composition get met with tighter downstream filtration and even extended aging if initial tests flag new impurity baselines. Our routine testing includes lots measured to the third decimal for water, peroxides, and metal ions, and we keep sample archive vials for every production run. Any lot that doesn’t pass gets investigated and is never reworked off-spec—reliability stems from starting over, not cutting corners.
We see manufacturing for chromatography as a craft. Small lot control meets production scale only when every system and team member keeps their eyes open for the unexpected. Handling butylamine for HPLC this way doesn’t mean slowing down or throttling capacity; instead, our yield improvements and automation always tie back to giving analytical chemists a product they don’t have to doubt. Our warehousing and packaging processes prioritize oxygen-avoidance, inert-blanketing and short cycle times from fill to seal, slashing the risk of airborne contamination. By training every operator who handles, seals, or ships these cylinders, we make sure the butylamine in each bottle matches what we see on our production terminals.
We built out multiple production bays for redundancy. If one line flags a possible contamination, another takes on the load. Our internal standard for releasing a batch never tracks precisely with published guidelines—sometimes we’re even more strict, informed by the feedback loops built over lifelong partnerships with analytical labs. With this model, users get the same product profile, whether they are ordering small bottles for R&D or large drums for validated process methods.
Butylamine is a relatively simple molecule—at least on paper—but in practice, its volatility, its tendency to absorb water, and its affinity for oxygen mean the difference between a clean elution and a baseline mess. We learned years ago not to shortcut dehydration steps in humid summers; the risk of subtle hydrolysis of analytes is too high. Our team tracks the conductivity and pH of every lot not just in blank solutions, but in simulated mobile phases that mimic the real operating conditions seen in pharmaceuticals or biochemistry. Each sample gets challenged against old column stocks, revealing any latent impurity that might stay hidden in fresh columns but rear its head during longer use.
The conventional wisdom that “HPLC-grade” equals “problem-free” rarely holds unless the producer takes responsibility for every phase, right down to the label. We sign off on each batch personally—everyone in this operation knows the stakes. Instead of simply listing pH, water or absorption limits on spreadsheets, we run side-by-side comparison chromatograms against typical lab standards, confirming no carryover or ghosting creeps in as mobile phase volumes increase. The strictness of our internal metrics grows out of fixing too many real-world baseline jumps caused by supposedly “good enough” grades offered by commodity suppliers.
Confidence in a chemical isn't something that appears overnight, and it never comes from an adjective or a claim on a website—trust builds when the lab team sees the same performance every order, every year. We get direct calls from analytical chemists reporting their results. Sometimes they report issues and we bite the bullet, check the archive, and in rare cases replace what went out. Usually, though, the comments are positive: decreased baseline noise, stable pH, minor impurities that stay tightly in spec, and, most importantly, a product that can disappear into the background while letting the science do the talking.
Many of our partners have challenged our batches using the harshest possible mobile phases—mixing strong acids, using tough columns, running long gradients with acetonitrile or methanol, stressing the system as hard as possible. Our butylamine for HPLC holds its own, batch after batch, year after year. We put forward the work and accept the occasional hard lesson, knowing that feedback always closes the loop back to improved production. In short, it is not just about following the book—it’s about learning from every real-world challenge and sharing that experience through every bottle that leaves our site.
Chromatography keeps evolving, and so does the demand for high-purity, low-background reagents. Each emerging technique, from faster high-resolution separations to complex biological sample analysis, stretches the requirements higher. We keep our tools sharp by remaining close to those who rely on our chemicals, tweaking each production change to address direct lab feedback—not hypothetical recommendations. If a user flags a trend, whether it points to odd retention, high UV background, or drift in mass spectral ionization, we track and respond.
Our approach ensures nothing is left to chance. Knowledge grows richer every production run, each interaction, and every story shared from the bench. The butylamine for HPLC you see today reflects hard-earned lessons, honest self-assessment, and a commitment to supporting labs where the stakes always feel highest. By remaining grounded in the basics—purity, transparency, immediate feedback—we deliver more than a label or a promise. We deliver a reagent made by chemists, for chemists, always ready for the realities of the application, not just the specification sheet.