West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

AzBTS [=2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] [for Biochemical Research]

    • Product Name AzBTS [=2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] [for Biochemical Research]
    • Alias ABTS
    • Einecs 629-050-4
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    862178

    Product Name AzBTS
    Chemical Name 2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)
    Synonym ABTS
    Molecular Formula C18H24N6O6S4·(NH4)2
    Molecular Weight 548.68 g/mol
    Cas Number 30931-67-0
    Appearance Green to blue powder
    Solubility Soluble in water
    Storage Temperature 2-8°C
    Application Used for biochemical research, especially as a substrate in enzyme assays
    Purity ≥98%
    Absorption Maximum 415 nm (oxidized form)
    Stability Stable when stored at recommended temperatures
    Brand for Biochemical Research
    Hazard Statements No significant hazard identified

    As an accredited AzBTS [=2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] [for Biochemical Research] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing AzBTS is supplied in a 5 g amber glass bottle, tightly sealed, labeled with product details, hazard warnings, and Sigma-Aldrich branding.
    Shipping AzBTS [2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] for biochemical research is shipped in tightly sealed containers to prevent moisture and contamination. It is transported at ambient temperature unless specified otherwise, following standard chemical handling protocols. Shipping complies with international regulations and includes safety documentation from suppliers like Sigma Aldrich, Merck, or TCI.
    Storage AzBTS [2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] should be stored in a tightly sealed container, protected from light and moisture, at 2–8°C (refrigerator temperature). Keep away from incompatible substances and sources of ignition. Store it in a cool, dry, well-ventilated place specifically designated for chemicals, and adhere to Sigma Aldrich, Merck, or TCI storage guidelines for biochemical reagents.
    Free Quote

    Competitive AzBTS [=2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt)] [for Biochemical Research] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    AzBTS: Precision and Reliability in Biochemical Research

    Elevating Assay Performance with Consistent Quality

    Inside our facility, the significance of producing AzBTS, or 2,2'-Azinobis(3-ethylbenzothiazoline-6-sulfonic Acid Ammonium Salt), is measured each day by the detailed QC records and trusted customer feedback. Many research teams turn to AzBTS for its clean, high-sensitivity readouts in enzymatic and antioxidant activity assays, especially in TEAC and peroxidase systems. Years spent refining the production line showed us every shortcut ends in wasted time or unreliable batches. We learned to control every variable starting at the raw input stage: the ethyl substitution, the sulfonation, the ammonium salt formation—all monitored batch to batch under fixed conditions. Each drum leaving our site reflects a backstory of hands-on development, instrument calibration, and scrutiny over crystal color, particle size, and solubility.

    Our team does not approach AzBTS like a commodity. From synthesis to purification, each step has been shaped by responses from bench scientists: requests for easy dissolution, low baseline absorption, and long shelf stability. These aren’t afterthoughts—they decide whether results stay reproducible across different labs or fade depending on supplier luck. We have invested in continual upscaling of filtering and washing stages. Unreacted starting material or remnants of oxidative byproducts cause off-shade color or unexplained side peaks in spectra—real risks for those measuring weak antioxidant signals. Any missed detail could flaw an entire experiment run, so we found satisfaction only after each batch passed repeated inspections not just by machine, but by the skeptical eyes of staff trained to flag anything unfamiliar. Our site’s control sheets track everything from temperature on synthesis to spectra through 400–800 nm. Nothing gets released if the solution gives a hint of background drift.

    Benchmarking AzBTS batches against long-archived reference material forms the foundation for our quality confidence. We push the process to keep absorbance maxima and extinction coefficients rock-steady, because researchers calibrate their readings against these values. Some labs have used lower-priced alternatives only to find they need two or three corrections per plate, fighting with uneven color development or sliding baselines. University core facilities share stories with us about how small shifts in the spectral max—usually from poorly controlled sulfonation—can derail a week’s run. Hearing these stories pushed us to implement extra purity controls and set stricter color thresholds than any customer ever asked for. This doesn't just support the science—it supports the teams relying on the trust that tomorrow’s batch matches the last.

    Why Purity and Uniformity Shape Real-World Results

    In practical research, the utility of AzBTS stretches across biochemistry, food analysis, and pharmaceutical screening. The chemistry behind its colorimetric response isn’t unique—other benzothiazole derivatives jump on radicals or react with oxidases. But from our point of view, what separates the material is how reliably and cleanly it does so, every time. Running ABTS-based assays demands substrates that dissolve perfectly and react without hidden contaminants or lots of pre-wash. Even slight changes in humidity during drying or oven cycles can impact crystal texture and dissolve time. This is why lab notebooks on our floor describe oven timings and storage conditions as carefully as the actual synthesis instructions. Any deviation, and our internal retests start—no matter the production schedule.

    Our refinement steps strip out colored byproducts that would otherwise contribute unwanted background to microplate readings. We keep particle size in a narrow range not for marketing claims, but because aggregation leads to inconsistent pipetting or delayed solubilization. In our real-world experience, customers notice the difference right away—some report using less volume to reach the required intensity, others say background signals flatten out, saving hours on recalibration. These are the results that matter, more than any certificate we print. One researcher described switching sources during a funding crunch, only to spend two weeks troubleshooting mysterious shifts in spectra. That experience mirrored our findings back at the bench; inconsistency in material always translates into wasted weeks.

    It became clear that for applications like TEAC, Ferrylmyoglobin assays, and peroxidase screens, researchers need to detect small changes in radical concentration under tight constraints. Off-color AzBTS throws off these measurements. Our team decided long ago that each kilo produced should look, dissolve, and measure the same as the one before, regardless of external pressures. We address minor impurities at the earliest stage possible and monitor each lot for end-use performance, not only traditional purity.

    Choosing Thoughtful Specifications Based on Laboratory Needs

    We established our specifications out of interactions with experienced biochemists. Some sought higher concentrations without background drift, others focused on optical density targets important for microplate throughput. Many labs report that spectral drift ruins their studies. After reviewing a wide set of feedback, we prioritized maintaining stable absorption maxima (around 414 nm for cation radical, 734 nm for the ABTS•+ solution) and minimal non-specific absorbance between 500–650 nm. Our raw materials come under scrutiny for metal ion trace analysis, since catalytically active metal residues can trigger side reactions, confusing the interpretation of antioxidant capacity or enzyme activity.

    Down the line, we employ fine crystallization and vacuum drying to tackle inconsistencies in the final product. A powder that clumps or cakes blocks uniform mixing in automatic pipettors. By controlling not only the reaction but also drying atmospheres and packing, we maintain a friable, free-flowing powder. The attention to moisture content pays back each season when environmental humidity changes around the factory. Failing to adapt for local weather ruined early runs years ago, causing us to reset our packaging protocol and invest in upgraded storage.

    Our internal models track particle size distribution and spectral absorption. Only lots that match performance of our in-house reference—kept under climate control for yearly retesting—move on to customer delivery. We once faced pressure to boost throughput by cutting aging steps before the final drying stage; that experiment cost us a series of complaints over batch-to-batch color variation. We learned: consistency requires patience and respect for the process, even when orders spike and warehouse space runs thin.

    Indispensable for Robust Colorimetric Assays

    Many research teams rely on AzBTS for its speed and reliability in color development, particularly for enzyme assays quantifying antioxidants and oxidant activities in foods, blood plasma, plant extracts, and drug candidates. The classic ABTS•+ radical cation forms instantaneously upon reaction with peroxidases or other oxidizers—promptly yielding the strong absorbance required for high-throughput readers. A sluggish or cloudy batch causes erratic delays, so our batches undergo time-resolved absorbance studies after each major process improvement.

    Our QC lab maintains real-use simulation records that mimic conditions customers experience: microplate readers with a range of lamp hours, solvents of varying pH, and different diluent water qualities (deionized, Milli-Q, type-I, etc.). We measure how quickly the color forms, its maximum intensity, and how stable the solution stays during the period most teams use for endpoint reading. Several customers running pharmacology screens credited our process with eliminating unexpected drops in absorbance mid-assay—evidence that careful purification translates to smoother workflows in busy labs.

    Since some labs test antioxidant or oxidant activity at low concentrations, we verify background absorbance down to microgram-per-mL levels. This detail saves researchers the frustration of troubleshooting unexpected absorbance gains or negative controls mysteriously lighting up. One technician from a food safety facility told us that switching to a less refined ABTS forced them back to blank-correction spreadsheets and hours of plate recalibration. Those stories reinforce the discipline we put into waste management, solvent recycling, and instrument calibration on the production floor.

    Differentiation from Other Suppliers’ Products

    After decades of supplying AzBTS directly, it became obvious that what sets one manufacturer apart isn't just the molecule, but how it’s made and handled. Some sources promote “lab-grade” with vague guarantees while blending batches after QC, leading to shifts in color, solubility, or spectral response not evident until real-life testing begins. We maintain single-lot segregation throughout packaging, tracked by internal batch codes, to ensure that what leaves the door can be traced back to instrument readouts for every processing step. No relabeling, remixing, or bottling offsite.

    Many labs asked about the “brightness” or color strength they see in AzBTS solutions. We traced these customer comments to minor differences in the ratio of the benzo-thiazole isomers or the completeness of ammonium salt formation—both simple on paper, but easy to mismanage at the industrial scale. We continually adjust our reaction control protocols to hit a deeply blue-green solution every time, rejecting anything that starts to brown or cloud. Others ship material with broad, undefined absorption shoulders, which become apparent only in kinetic plots or low-volume plates. We worked to eliminate this issue and still run each batch against historical absorption profiles to catch slips no reference standard might find.

    Storage and handling differences count as well. AzBTS reacts with atmospheric oxidizers, so packaging matters: air- and moisture-tight containers, limited headspace, and a built-in desiccant, all sealed under low humidity. Some competitors cut corners here, leading to drift in product quality as soon as the powder sits idle. Customers who store material for several months notice the difference: no unexplained cloudiness, no need to filter; just reliable performance. For us, shipping means not just releasing bulk, but continually training our staff in packaging, sealing, and material tracking, even redesigning containers as feedback emerges.

    Learning from the Bench: Everyday Lessons in Manufacturing

    Entering the world of AzBTS manufacturing challenged us to think like our end users: to picture the plate reader, the multi-channel pipette, the hurried sample prep late at night. We know that waiting for a fresh delivery or replacing off-colour powder mid-project wastes more than cash; it can mean missed deadlines, lost replicates, and broken continuity. Our lab doesn’t ship material until it’s been steeped and filtered in the same way our customers will use it, often preparing real-use solutions to check for sediment or delayed color.

    During the early years, we missed minor process details—a misjudged wash solvent, a forgotten hold time. The effects showed up far downstream: subtle color haze, slow-dissolving particles, or a sticky residue clinging to measuring flasks. Every time an issue emerged in customer hands, we ran mockups to reproduce the fault, refusing to ship until we found a fix. Staff have learned more from these days than any training manual ever offered. Improvements grew out of repeated engagement: phone calls walking through assay steps, video checks on how the powder stirs in customer solutions, and shared lab photos showing unexpected results.

    As a result, we document changes—even seemingly minor tweaks to reaction order or equipment cleaning—so nothing catches our team by surprise. We log not only raw material sources, but their prep lot, transit climate, and storage conditions. Whenever a question comes from a customer, our records show the full story, letting us trace performance all the way back to a rainy week on the loading dock or a shift supervisor’s note about temperature drift.

    Supporting Research Progress with Tailored Solutions

    Our direct relationship with working researchers means AzBTS isn’t just something we sell, but something we continually refine. Some teams request larger particle sizes for specific high-throughput liquid handlers; others need packaging adjusted for distributed storage across campus or remote field projects. We adapt because ignoring these requests means risking relevance. For labs seeking higher throughput, we offer bulk sizes packed to their run rates, reducing repackaging hazards and mix-ups. For those with sporadic use, we fine-tune pack sizes to ensure minimal air exposure and consistent quality to the last scoop.

    We partner in method-development phases, openly sharing batch data, spectral fingerprints, and solubility stats. Several academic consortia used our feedback loop to tune their TEAC or peroxidase protocols, shaving minutes off prep and cutting down error-prone steps. On occasion, labs experimenting with automated dispensers reported clogging trouble with competing powders; we worked directly to alter grind size and anti-caking methods until their process stabilized. Such partnerships lead to a product that reflects both manufacturing discipline and scientific flexibility.

    Our experience demonstrates that the value in AzBTS isn’t captured in a spec sheet. It shows in the confidence our partners have placing an order, setting up their plates the same day the powder arrives, and running their assays without repeat troubleshooting. Once, a university screening facility ran comparative assays on samples from different sources. Our material yielded consistent signals without drift; a less controlled source produced outliers and escalating blank values, unexplainable outside a full-blown forensic analysis of supplier handling.

    Meeting the Standards of Modern Biochemical Research

    The research field continues to move toward greater automation, higher throughput, and tougher scrutiny over data reliability. These demands pressure us to maintain, and even raise, the standard on every lot of AzBTS. We maintain continuous dialogue with leading instrumentation companies, picking up details on plate reader trends and emerging measurement needs. As a result, we have shifted certain process parameters to meet higher absorbance accuracy at low pathlengths, and adjusted washing protocols to lower trace contamination. In a climate that values reproducibility above quick output, such details matter more each year.

    Our investment in in-house analytical tools means we do not rely on contract labs—differences between report and reality cost everyone in the end. We cross-validate in real-world conditions: running parallel plates, different wavelengths, old and new readers. This redundancy catches the sort of lot-to-lot variation other suppliers might miss or ignore. When feedback from researchers suggested seasonal climate swings affected apparent solubility in one region, we found packaging controls that ended the problem, proving how granular controls sometimes solve global problems.

    As open-access science grows, and multicenter collaboration expects more from each supplier, we continue integrating feedback to keep AzBTS ahead of research needs. Our product acts not just as a reagent, but as a partner in scientific progress—one shaped by daily learning, collaborative troubleshooting, and relentless attention to real user results. This approach underpins every batch we produce, every process we tweak, and every customer problem we solve together.