HS Code |
117296 |
| Product Name | A 83-01 [Optimized for Cell Culture] |
| Cas Number | 909910-43-6 |
| Molecular Formula | C25H19N5O3 |
| Molecular Weight | 437.45 g/mol |
| Purity | ≥98% (HPLC) |
| Appearance | White to off-white powder |
| Solubility | DMSO, Ethanol |
| Storage Temperature | -20°C |
| Target | TGF-β Receptor I/ALK5 inhibitor |
| Application | Cell culture, biochemical studies |
| Synonyms | A83-01, A-83-01 |
| Sensitivity | Light sensitive |
| Cell Permeability | Yes |
| Inhibitory Concentration Ic50 | 12 nM (ALK5) |
| Recommended Concentration | 0.5–10 μM |
As an accredited A 83-01 [Optimized for Cell Culture] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | A 83-01 [Optimized for Cell Culture] is supplied by Sigma, 25 mg per amber glass vial, clearly labeled and sealed. |
| Shipping | A 83-01 [Optimized for Cell Culture] from Sigma Aldrich/Merck/TCI Chemical Grade is shipped at ambient temperature unless otherwise specified. The product is securely packaged to ensure stability and prevent contamination or degradation during transit. Upon receipt, it should be stored as recommended in the product datasheet for optimal performance. |
| Storage | A 83-01 [Optimized for Cell Culture] from Sigma Aldrich/Merck/TCI should be stored at -20°C, protected from light and moisture. Keep it tightly sealed in the original container and avoid repeated freeze-thaw cycles. Ensure the storage area is secure and dry, and the chemical is labeled clearly. Adhere to all relevant safety and handling guidelines for optimal stability and performance. |
Competitive A 83-01 [Optimized for Cell Culture] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In our lab, we spend each day focused on molecules that shape the future of cell biology, and it’s easy to see the difference one compound can make. Some products drop into cell culture protocols and quietly fade into the background, but A 83-01 tends to have the opposite effect. Our team manufactures A 83-01 under conditions that meet the sharper demands of cell culture work, especially in research settings exploring stemness, differentiation, and the complex dance of TGF-β/Smad signaling. From experience down at the bench, we know it – a true tool should not simply exist on the reagent shelf but should actively open research avenues that were previously closed. Scientists do not want unexpected batch variability, residual contaminants, or formulation ambiguities slowing their progress. That’s why A 83-01 made for cell culture reflects our continual effort to meet and anticipate those expectations.
A 83-01 stands out as more than a TGF-β type I receptor inhibitor. We’ve learned from countless conversations with clients: researchers want high-purity, cell-culture-ready molecules that support experimental reproducibility without excessive troubleshooting. Journal protocols now call for A 83-01 by name for maintaining pluripotency, promoting iPSC colony formation, or even for reprogramming adult cells. There’s demand for specific activity, not just chemical identity. Our approach tailors A 83-01 with this precision in mind, learning from published methods but also listening to the feedback that comes in after each lot is shipped and tested “in the wild.”
From the start of manufacturing, our chemists keep a close eye on each synthetic step, assessing for byproducts that may elude basic quality control assays. Over the years, we’ve refined conditions to control for trace water and ionic contaminants that can interfere with cells on long-term passage or in sensitive differentiation assays. A 83-01 [Optimized for Cell Culture] reaches a minimum purity standard we reserve for the most demanding biological readouts. Each lot goes through targeted ion chromatography and dissolution testing, not only standard HPLC. These steps matter. We have seen how cells can sometimes respond more to what is left out of a preparation than what is put in. For our product, stability during storage and handling is achieved by close monitoring of residual moisture, packaging under inert gas, and using containers that do not leach plasticizers or release unexpected extractables. This attention to detail springs from direct feedback and collaboration with labs that run extended, high-throughput screens.
We do not treat grade selection as an afterthought. Our optimized version is manufactured under protocols that address the needs of serum-free, feeder-free environments where stem cell and progenitor cell identity only survives under the tightest control. Testing every batch with functional assays on cells—often using neural, cardiac, or hepatic progenitors—allows us to follow not just the short-term cytotoxicity but subtle, longer-term impacts. The product’s structure is 6-[2-(1H-Indol-3-yl)ethyl]-3-(3-pyridyl)pyrido[1,2-a]pyrimidin-4-one, as chemically described in the primary literature, but the difference between compounds comes down to residual solvents and scalable purity that supports a real-world workflow. We have heard from more than a few labs that the unoptimized, bulk chemical does not deliver consistent colony morphology or gene-expression maintenance. Our process replaces hand-waving assurances with actionable, real differences.
Working hands-on with A 83-01, the meaning of “optimized for cell culture” becomes clear. End users prepare the compound in DMSO at micromolar working concentrations, incorporating it into basal media in protocols similar to those found in peer-reviewed iPSC or organoid protocols. Our manufacturing supports gentle dissolution and reproducibility, even across scale-up. In neural induction or conversion workflows, where factors like SB431542 or similar TGF-β inhibitors are sometimes swapped out, side-by-side comparisons frequently lead teams to prefer our formulation. They report reduced background toxicity and more consistent cellular responses over repeated passages.
Working in bench labs ourselves, we’ve seen firsthand how minor lot-to-lot variability can jeopardize weeks of culture. Not every research group has time to continuously validate every order, so lowering the risk of unexplained culture loss has become a foremost priority. To that end, A 83-01 [Optimized for Cell Culture] is checked by running actual cell-based functional quality control assays—not only analytical chemistry endpoints—on real human pluripotent stem cell cultures. Not every chemical supplier makes this investment, but we persist because we understand the stakes.
Ask any researcher how a “catalog” grade TGF-β inhibitor behaves, and the answer points to the vagaries of cost-saving synthesis. More often than not, products sourced without cell culture validation bring in mystery peaks in LC-MS or leave behind hydrophobic or ionic residues that build up in long-term cultures. In contrast, our A 83-01 comes engineered for environments where even tiny fluctuations in compound purity translate to major shifts in phenotype, gene expression, and overall experimental reproducibility.
Our industry has seen researchers frustrated by spontaneous cell death, unexpected differentiation, or unexplained clumping—all traced back to inconsistent quality in their TGF-β inhibitors. We invite direct feedback and provide transparent batch records because our manufacturing experience has taught us the value of traceability. Every user receives access to detailed lot performance data and, when available, comparative cell-based results from our own internal studies.
Batch-to-batch reproducibility ranks high for our long-time clients. Years spent synthesizing small batches, scaling up, and tracking root cause in cell culture variability has hammered home the reality that even near-invisible process changes can ripple through to biological consequences. In our direct experience, only by investing in tight controls—equipment calibration, raw material qualification, cross-checking of in-process analytics—can one achieve genuine lot reliability. Every shipment leaves our facility with traceable raw materials and full synthesis records, which gives principal investigators and lab managers the confidence to expand their research pipelines or move to clinical research applications.
One major advantage of handling both synthesis and direct support is the ability to close the feedback loop. We do not merely move product from a warehouse; instead, we actively discuss new protocol modifications, unexpected cell responses, or reported issues around solubility and DMSO compatibility. Years on the production floor and supporting our partners in academic and biotech labs allow us to continuously improve our approach. Our chemists personally field protocol questions, troubleshooting with real-world context. This fosters a collaborative problem-solving spirit and keeps us alert to subtle shifts in the market and in published cell culture techniques.
Trust does not arrive overnight. We believe that openness—providing full certificates of analysis, in-depth impurity profiling, and detailed dissolution data—equips customers with confidence and enables authentic partnership.
A 83-01’s impact stretches beyond stem cell biology. Labs using it in organoid systems, cancer modeling, and small-molecule reprogramming protocols report that product quality can shorten experimental timelines and minimize waste. Through these channels, feedback shapes our manufacturing. For example, teams exploring direct neuronal conversion or challenging pancreatic progenitor expansion sometimes need large, consistent lots for multi-month experimental runs. When working with basic research reagents, budget constraints make every vial count. That’s why we emphasize direct lot-to-lot validation for these advanced workflows. Some lower-spec versions, even with superficially similar purity scores, fail to maintain morphologic and molecular identity in the way that our process-optimized A 83-01 does.
From our daily operations, it is clear that cell fate decisions respond not just to growth factors but to every nuance in small-molecule environment. That realization has fueled our investment in not just one-time, but continual verification of each step in post-synthesis handling, crystallization, and storage. Even the DMSO stock solution protocol, which can seem trivial, is modeled after real lab usage cases and adjusted based on long-term feedback from our collaborating scientists.
Solid-state handling and shipment remain a quiet source of trouble in the chemical supply world. Small tweaks in residual moisture, plasticware leaching, or solvent residue can result in months of troubleshooting for users. We have tackled this challenge by designing solid-state isolation and storage protocols built to survive global logistics and unpredictable storage conditions typical in academic and industry environments. This granular attention has measurable results: less time spent revalidating stocks enables labs to move directly to experimental work. Further, researchers running high-throughput screens appreciate the reduced risk of unexpected precipitation or loss of solubility after repeated freeze-thaw cycles.
We routinely hear from methodology developers and protocol optimization teams integrating A 83-01 into combinations with CHIR-99021, Y-27632, or PD0325901 in the so-called “small-molecule cocktails” found at the core of most modern stem cell maintenance and differentiation workflows. Fewer downstream surprises translate into more successful, publishable experiments. Steering our manufacturing by this feedback has allowed us to offer a product profile that matches not just chemical benchmarks but the biological realities of demanding research.
Our strong ties with both established and emerging research teams ensure that the product remains tuned to advances in the field. Whether in organoid formation protocols, direct cell fate conversion, or tailored transdifferentiation pathways, customers working with our A 83-01—formulated for demanding cell culture contexts—report fewer confounding factors interfering with their readouts.
Not every researcher trained in biology has access to deep chemical expertise. To support the next wave of cell culture protocols, we include explanatory technical resources alongside each shipment—not dense jargon, but straightforward documentation and examples based on laboratory scenarios. This helps new users ramp up quickly and prevents common errors such as incomplete dissolution, improper storage, or misjudged working concentration. The feedback of experienced users ensures that our support materials remain current and useful.
Most chemistry suppliers aim to reach basic purity specs, but the true difference appears down the line—in the real cost and effort of failed experiments, lumpy growth, or gene expression drift. We’ve spent years at the bench troubleshooting these failures and have tailored our production of A 83-01 to actually address them. For us, an “optimized” grade is not a marketing flourish; it is the result of careful listening and learning with every batch. From direct cell-based assays to meticulous contaminant monitoring, every lot reflects feedback from failed and successful runs alike.
Each synthesis, purification, and packaging step happens onsite under our team’s supervision, not outsourced or masked behind layers of distribution. Staff who work with these chemicals have backgrounds in both synthetic chemistry and cell biology, so they quickly spot subtle quality shifts that only appear at the interface of precise chemistry and living systems. In this way, we support not just today’s workflows but future advances, including automation-driven biology and clinical pipeline development.
Every researcher faces the reality that protocols often work only as well as their weakest component. A proven, cell-culture-optimized A 83-01 minimizes uncontrolled variables. Protocols published in leading journals mention this compound by model and vendor because the source matters. Our batch records and residue analysis ensure that no hidden contaminants or inactive isomers creep into working stocks. This matters in fundamental discovery and as cell culture workflows move toward translational and clinical research.
Demand for cell therapy products and organoid disease models continues to grow, and consistency has never been more crucial. By constantly refining our methods and listening to research teams, we keep our A 83-01 at the leading edge of cellular reprogramming and tissue engineering.
Cell biology now operates at scales and levels of complexity that a one-size-fits-all reagent no longer suffices. Every experiment hinges on the trust placed in core small molecules like A 83-01. By investing in dialogue-based improvement and transparent manufacturing, we support those pushing the boundaries of reprogramming, maintenance, and differentiation. Each chemist and biologist on our team knows from experience that even a minor slip in process control can cost days or weeks of research. This knowledge drives home the need for precision and sustained rigor in every aspect of production and support.
From single-vial orders in university settings to large-lot runs for international consortia, feedback continually shapes how our A 83-01 [Optimized for Cell Culture] evolves. Our team remains accessible for questions, protocol reviews, and custom formulation requests because every use case informs future improvement. We view ongoing, honest feedback as our greatest resource for both innovation and reliability.
By manufacturing and supporting A 83-01 optimized for cell culture, we enable labs to devote more time to asking big biological questions and less time chasing down quality issues. Our compound isn’t shaped only by industry trends—it’s the product of long-term partnerships with those refining the cell cultures that drive tomorrow’s therapies and discoveries. We believe this on-the-ground, hands-dirty knowledge—shared among chemists and biologists—makes all the difference. Our doors always remain open to feedback, requests for new formats, or deeper explanations of our methodology, because staying responsive keeps both our company and our research partners advancing together.