|
HS Code |
318351 |
| Product Name | 6-Carboxyfluorescein Diacetate |
| Cas Number | 92557-81-8 |
| Molecular Formula | C25H19NO9 |
| Molecular Weight | 477.42 |
| Appearance | Yellow to orange solid |
| Solubility | Slightly soluble in DMSO, DMF |
| Excitation Maximum | 492 nm |
| Emission Maximum | 517 nm |
| Storage Temperature | -20°C, protected from light |
| Purity | Typically ≥95% (HPLC) |
| Synonyms | 6-FAM Diacetate |
| Applications | Cell viability and esterase activity assays |
As an accredited 6-Carboxyfluorescein Diacetate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 6-Carboxyfluorescein Diacetate, 100 mg, is packaged in an amber glass vial with a tamper-evident screw cap, Sigma-Aldrich branded label. |
| Shipping | 6-Carboxyfluorescein Diacetate (Sigma Aldrich/Merck/TCI Chemical Grade) is typically shipped in tightly sealed amber vials to protect from light and moisture. The chemical is transported at room temperature or cold pack depending on destination, and labeled according to hazardous material regulations to ensure safe delivery and handling. |
| Storage | 6-Carboxyfluorescein Diacetate (Sigma Aldrich/Merck/TCI Chemical Grade) should be stored tightly sealed in a cool, dry, and well-ventilated place, away from light to prevent degradation. Recommended storage is at -20°C or lower. Avoid exposure to moisture and oxidizing agents. Store in original container and handle under subdued light to maintain chemical stability and fluorescence properties. |
Competitive 6-Carboxyfluorescein Diacetate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
6-Carboxyfluorescein Diacetate—commonly referenced by its abbreviation 6-CFDA—captures much of our daily attention on the production floor. We know this compound as more than just a catalogue entry. Each batch stands as the result of hands-on synthesis, frequent batch-to-batch monitoring, and regular consultation with researchers using our product in real experiments. Our manufacturing chemists pull together years of practical skill, always pressing for high purity and consistent yields. Customers who call our technical line speak to the same team that troubleshoots reactions and solvents right here in-house. The feedback cycle is short. Our improvements build steadily, grounded in what users tell us, not a distant marketing goal.
Our daily goal is to ensure that every gram of 6-Carboxyfluorescein Diacetate arrives as fresh as we intend, clean, active, and ready to dissolve for trace experiments or whole-cell tracking. We handle our product, down to the packaging atmosphere and light exposure, with the same care we use for other specialty fluoresceins, because a small amount of degradation can alter experimental results. We have invested years refining our crystallization methods, scaling cleanly from milligram test runs to multi-hundred gram lots, always aiming for the shortest possible lead times on replenishment.
Inside laboratories around the world, 6-CFDA has become a mainstay for common viability, esterase activity and live/dead cell tracking protocols. Our observations from hundreds of client conversations closely match published data: researchers often choose the carboxy derivative over the regular fluorescein diacetate (FDA) due to the enhanced retention of its cleaved product inside cells. The carboxylic acid group provides a negative charge that limits efflux, increasing signal window and leading to more reliable, interpretable results. Many researchers working in plant or animal cell systems, including those studying cytotoxicity or multi-well plate assays, build entire measurement protocols around this unique property.
Users frequently note, and our own validation supports, how 6-CFDA’s increased hydrophilicity compared to unmodified FDA cuts down on non-specific background fluorescence. The improved retention drives clearer endpoint readouts, especially important in experiments that monitor single-cell changes over time or across high-throughput screens. Earlier in the field, we ourselves found that FDA-labeled cells displayed weaker contrast and problematic dye leakage, especially when the protocol called for longer incubation or thorough washing steps. That experience motivated our original decision to bring 6-CFDA production in house, putting control of purity and stability directly in our hands.
In practical terms, the performance of 6-Carboxyfluorescein Diacetate arises from tight attention to detail during synthesis, not just a generic purity figure. Our operators measure reaction endpoints with a suite of analytical tools, not only HPLC, to catch even modest changes in isomer ratios or trace byproducts. Every new production run builds on a log of detailed lab notebooks and batch records—many of our chemists have spent years tracking how pH, time, and fresh reagents alter yields and final optical properties. We quickly catch differences between syntheses, and we do not shy away from revising our procedures mid-stream to address the unexpected.
Microcrystalline appearance, color, and even the faintest scent give cues about processing history, and our staff use these physical characteristics alongside data to flag issues before the product leaves our building. Our packaging staff store finished product under protective gas, in amber containers, with sealed liners. We have learned over time that even brief exposure to ambient air or bright light can promote hydrolysis or photo-induced byproducts, so we stick to strict procedural standards drawn from repeated, documented failures and improvements.
It’s tempting to lump all fluorescein derivatives together. On the bench, though, researchers find substantial differences. FDA and CFDA-SE (Carboxyfluorescein diacetate succinimidyl ester) both fill different roles, usually dictated by experimental endpoint, cell type, and wash conditions. While FDA provides a quick readout for esterase activity, 6-CFDA unlocks longer-term cell viability tracking thanks to its stable, charged carboxyl product that stays within the membrane. CFDA-SE, on the other hand, produces a covalent bond with intracellular proteins, supporting multi-generation tracking, but often at the cost of greater initial cell manipulation or higher non-specific binding in stickier, protein-rich tissues.
We see that most customers move to 6-CFDA when their older FDA-based protocols fall short during fluorescence washout steps, especially in flow cytometry or imaging. FDA leaks out of viable cells far more rapidly, which sometimes forces rushed, less reproducible analysis. At our own demo bench, side-by-side runs show clear differences in time-dependent fluorescence decay. This is not just a theoretical distinction—a decade of customer-reported results has pushed us to refine the solubility and crystal habit of 6-CFDA for lowest clumping and fastest uptake, which older generic lots failed to provide.
As a producer, our direct conversations with lab staff and principal investigators across biosciences have focused not only on purity or price, but also on the nitty-gritty problems of solubilizing, aliquoting, and dosing the compound for hundreds of day-to-day applications. 6-CFDA, inherited from the classical fluorescein chemistry world, presents specific quirks: some solvents and containers interact unfavorably with it, especially as batch scales rise or protocols shift toward longer storage.
We have learned—sometimes by accident on our own research bench—that certain grades of DMSO, inappropriate pipette tips, or incompatible storage tubes can introduce trace contaminants that confound downstream fluorescence. For this reason, our technical bulletins draw directly on mishaps that affected actual users, not just generic supplier advice. We stress personal experience: earlier, we underestimated the effect of moisture pickup during aliquoting—one bout of humidity during powder dispensing led to hydrolysis and lower shelf stability. After identifying the root cause, we installed dehumidified dispensing hoods, updated standard operating procedures, and now train each lot handler with direct, hands-on walkthroughs.
These procedural refinements matter far more than a passing mention of purity. Experienced lab hands know the difference between reliable and frustrating dyes, and we listen repeatedly to user suggestions, iterating whenever we find an edge case not covered by protocol. Our facility keeps a rotating sample reserve, regularly comparing product run-to-run, and feeding those data directly back into our improvement cycle, since batch variation frustrates repeatable science.
As a global supplier producing 6-CFDA at scale, we see cross-disciplinary demand not just from academic biology, but also from pharmaceutical quality control, environmental monitoring, and food safety labs. Tens of thousands of different researchers count on reliable esterase indicators. Some users apply our compound to plant protoplasts under stress, while others stain white blood cells to measure toxicity or activation effects. We once worked with a team tracking membrane integrity in fungal spores—an application that required a careful tweak to our recrystallization, in response to unexpected precipitation in their lysis buffers.
Unlike many colorants, 6-CFDA serves best in live, functional assays, not simply as a visual marker. Its conversion by intracellular esterases opens a direct window into metabolic activity and membrane integrity. Our expertise grew partly through close partnerships: troubleshooting, side-by-side protocol development, and even real-time video calls looking down microscope objectives. These partnerships have sharpened our analytical workflows, driving efforts to simplify usage for newcomers, standardize documentation, and troubleshoot unexpected sample failures.
We keep production cycles close to our raw material suppliers to minimize delays and pre-empt possible shortages, having learned the hard way that distant intermediaries can disrupt timelines for fragile specialty chemicals. For some suppliers, fluctuations in the cost or quality of fluorescein intermediates or acylating agents can throw off entire quarters’ forecast. By cultivating redundant supplier relationships, we buffer our pipeline against single-source problems and import delays.
As chemical registration constraints and end-user documentation demands grow stricter, our plant staff attest product provenance and regulatory compliance based on actual manufacturing logs, not templated paperwork. Governments and large end-users increasingly request full traceability down to parent lot and shipment batch. Rather than treat these needs as paperwork burdens, we integrate them into our tracking workflow—from raw material drum intake to finished bottle shipment. Long before “E-E-A-T” became a talking point, we found that wins in traceability and transparent communication translate directly to user confidence.
As practical chemists, we value clear, experience-driven communication. Rather than simply issue a specification sheet, we maintain an open line to our customer base, accustomed to hearing tough questions and real setbacks. Our in-house application team knows the gray areas between theory and bench practice. For 6-CFDA, protocols often need customization: slight tweaks to pH, buffer, or concentration may rescue a failing experiment.
Every troubleshooting case feeds back into process improvement. Just as we learned from recurrent reports of off-white fluorescence in freshly reconstituted solutions, our improvements to drying and filtration came through repeated field failures, not theoretical best practices. We document these lessons in updated technical bulletins sent directly to all regular buyers — an approach based in mutual trust.
Even as analytical instrumentation sharpens, the human element matters most. Chromatograms and spectral overlays signal most defects, but some concerns only emerge at scale—static charge buildup affecting flow of powder into vials, trace migration of solvents, subtle lot-to-lot spectroscopic differences. On several occasions our on-floor team has caught a potential issue before shipment, recalling product, re-testing, and discarding out-of-spec material. We make no secret of these actions to end-users, because most experienced scientists would rather wait for a sound delivery than work with questionable materials.
Our lab maintains ongoing proficiency testing—comparing fresh synthesis runs against long-term reference standards, making sure that new staff learn to recognize both the signature yellow-green hue and less obvious signs of product aging or minor contamination. As stringent as regulatory checklists may seem, our internal standards run even tighter, pushed by decades of accumulated customer feedback.
Advances in 6-CFDA chemistry arise from fields as diverse as synthetic organic chemistry and cell imaging. Much of the progress originates not from top-down product development, but from continuous, iterative feedback between users and producers. We once believed, with good reason, that purity and stability were the whole story, but learned that mixing, solubility, and handling quirks can decide whether a batch delights scientists or frustrates them.
By collaborating with groups studying emerging cell types, such as induced pluripotent stem cells or plant lines previously untested with this dye, we’ve adapted release criteria, application guidelines, and packaging protocols in step with these new demands. Feedback on every failed dissolution or strange background signal informs the next production run.
Our direct involvement in production gives us a hands-on grasp of quality assurance. Unlike resellers or catalogue blenders, we troubleshoot right at the reactor, adjusting real time to solvent, temperature, or pH drift. This reduces the frequency of surprises mid-shipment or mid-experiment. Large institutional buyers rely on us not just for regular deliveries, but also for emergency batches, because they know we keep a continuous line between synthesis and shipping.
We take pride in our failures as much as in our successes. Many of our best practices—like freezing batch samples, using low-temp packing lines, or selecting oxygen-scavenging caps—emerged from users flagging past issues. Each resolved complaint sharpens the next run, cementing trust. We approach QC documentation as an evolving narrative built as much on setbacks as on achievements.
Researchers today depend on more than a label; they demand consistency and expert backing. Our staff know the quirks of 6-CFDA because we have spent years producing, packaging, and supporting the compound through countless user protocols. We answer phone calls about buffer mismatches, photostability concerns, or signal decay because we have internalized those headaches through our own internal R&D. No outsourced application support can compete with direct, daily involvement.
Seasoned users recognize when a supplier supports them through protocol failures as well as smooth experiments. By sharing real-world failures, optimization tips, and practical advice, we offer more than a single-use batch; we extend a long-term partnership that supports both routine and novel experimental goals.
Manufacturing 6-Carboxyfluorescein Diacetate isn’t just an exercise in scaling up a known reaction. Decades on the line teach how every process tweak, packaging improvement, or communication failure shows up directly in the lab experience. We invite researchers to engage us with their toughest protocol questions, knowing that every exchange improves both our product and their outcomes. The story of 6-CFDA continues to evolve—one batch, one experiment, and one shared success at a time.