HS Code |
546223 |
| Product Name | 5-Chlorofuro[3,2-b]pyridine |
| Cas Number | 886373-43-7 |
| Molecular Formula | C7H4ClNO |
| Molecular Weight | 153.57 |
| Appearance | Off-white to yellow solid |
| Melting Point | 52-56°C |
| Smiles | C1=COC2=NC=CC(=C12)Cl |
| Inchi | InChI=1S/C7H4ClNO/c8-6-2-1-5-4-10-7(5)9-6/h1-4H |
| Synonyms | 5-chloro-furo[3,2-b]pyridine |
| Solubility | Slightly soluble in organic solvents |
| Storage Conditions | Store at room temperature, dry conditions |
| Purity | >98% (typical) |
As an accredited 5-Chlorofuro[3,2-b]pyridine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 5-Chlorofuro[3,2-b]pyridine (1g) comes in a clear, amber glass vial with a white cap and detailed chemical labeling. |
| Shipping | **Shipping Description for 5-Chlorofuro[3,2-b]pyridine:** This chemical is securely packed in sealed containers to prevent contamination and moisture ingress. It is shipped under ambient temperature unless otherwise specified, accompanied by a safety data sheet. Packaging complies with international transport regulations for laboratory chemicals and ensures safe transit from suppliers such as Sigma Aldrich, Merck, or TCI. |
| Storage | 5-Chlorofuro[3,2-b]pyridine should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible substances such as strong oxidizers. Protect from light and moisture. Follow all standard laboratory chemical storage protocols and consult the supplier’s Safety Data Sheet (SDS) for additional safety recommendations. |
Competitive 5-Chlorofuro[3,2-b]pyridine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every production batch tells a story of patience, intentional design, and a relentless focus on purity. In our chemical plant, the routine doesn’t start with a sales pitch or a catalogue—chemistry starts with real people and dedicated equipment. We’ve watched hand after hand tighten valves and make incremental adjustments under the scrutiny of our own eyes. Producing 5-Chlorofuro[3,2-b]pyridine doesn’t simply mean filling orders, but respecting its character: a crystalline solid, golden to the eye, stubborn at times but consistent when handled correctly.
Everyone wants numbers, but the real story lies in what those numbers mean for a finished product. The material itself, 5-Chlorofuro[3,2-b]pyridine, arrives with a CAS of 882847-35-0 and a molecular formula of C7H4ClNO. The molecular weight reads out as 153.56 g/mol, which isn’t just trivia—it shapes how it carries through distillation or crystallization, how it feels as it flows through a vacuum line, and how our operators gauge the need for dryer cycles. Our process targets a purity level above 98%, but on a practical level, we push purities higher before signing off on any shipment. Every drum and bottle reflects not just compliance but days of iterative purification and filtration—never a straight line, always under adjustment based on the quirks of each batch.
Many ask about the differences between this compound and the dozens of heterocyclic intermediates on the market. We see the differences right from the moment the chemical reacts to heat: 5-Chlorofuro[3,2-b]pyridine refuses to tolerate shortcuts. Its structure—a fused furan and pyridine ring, with the chlorine at position 5—makes for reactivity that is unique. The bond strength and the position of the chlorine atom affect both the stability under typical storage and the outcome during Suzuki or Buchwald-Hartwig couplings.
During reactions, we have watched as slight changes in temperature or moisture throw off the course of a coupling. Other analogues drift in terms of solubility and shelf life; this material maintains its integrity but punishes complacency. Colleagues sometimes expect another dichloropyridine or similar halogenated furan derivative to perform under the same settings—find out quickly, they can't. Automated systems don’t catch every oddity: hands-on, we notice slight shifts in crystal habit or faint color change long before machines blink a warning. Each observation means the difference between a material fit for downstream pharmaceutical synthesis or time lost on preventable troubleshooting.
The chemists in both research and process development know that you don’t just buy an intermediate; you invest in reliability, reactivity, and workability on scale. In our facility, 5-Chlorofuro[3,2-b]pyridine isn’t a bench-scale oddity. We have enabled projects for kinase inhibitor development, fused ring modifications, and advanced agrochemical syntheses. Over the years, the compound demonstrated efficiency in building up bicyclic or polycyclic scaffolds. Few else in the building blocks catalog can, with the same ease, transfer that chlorine in cross-coupling while keeping the fragility of the furan ring intact.
We watch our compound serve as a linchpin in the design of complex heterocycles and pharmaceuticals. One recent pharmaceutical client reported higher success with our product in the construction of fused pyrido-furan systems compared to competitors’ versions—differences tracked to impurity profiles and consistency from batch to batch. In our shop, reactivity matters more than a printed analysis: if it cannot reproduce results at scale or meet the safety benchmarks, it doesn’t move.
On a day-to-day basis, this molecule brings us both routine and challenge. The crystalline nature helps with weighing and dosing, but it clumps when moisture sneaks in or if a container sits unchecked for too long. We’ve adjusted those realities by using desiccators, double-lined bags, and dehumidified rooms. Each operator, from packaging to logistics, signs off on packaging tightness and storage handling.
One batch taught us that trace impurities of HCl shifted over time under poorly sealed lids. Now, routine pH checks and headspace testing are standard, matched with an intense discipline on absolute cleanliness. We don’t take short cuts or rely on hope that “that much is probably fine”—we’ve seen too many production cycles derailed by such assumptions, so we designed protocols with redundancy. As a manufacturer, heavy investment in quality at this early stage pays back when clients report less process variability and higher reaction yields.
As manufacturers, purity isn’t just a marketing word—it’s the backbone of our daily practice, and the most common demand from clients. Whether a kilo-scale order or a twenty-gram research project, every batch gets the same scrutiny. Impurities at parts-per-thousand levels, especially residual solvents and related side-products, can stall project timelines or compromise whole campaigns in pharmaceutical settings. We run NMR, HPLC, and GC testing on every lot. Several years ago, a client received product from another source, finding that a minor byproduct catalyzed unwanted isomerization. Their research derailed until our cleaner, more consistent compound arrived, restoring their timelines and protecting intellectual property, not just their synthetic outcome.
Most users may not see the labor behind spectral purity. In the plant, teams invest hours into slow evaporation, careful chromatography, and re-crystallization. We train eyes and hands to spot an off tint or odor—subtle signs invisible to automation. These practices add measurable time and cost, but the downstream rewards come in the form of successful reactions and returning customers, whose own deadlines and research integrity depend on a foundation they can trust.
Scaling up brings its own headaches: from hot spots inside the reactor to the unpredictable flow of solidified product in auger-based conveyors. 5-Chlorofuro[3,2-b]pyridine pushes operators to keep tight temperature control and aggressive monitoring for localized impurities. Some suppliers cut corners, relying on default protocols meant for less sensitive compounds. Our team found, through expensive trial and error, that robust in-line analytical feedback during every shift pays off.
Chlorinated intermediates can kick off side reactions if even trace oxidants or reactive metals contaminate the apparatus. After one costly shut-down, we overhauled our cleaning regime and replaced some process lines with compatible alloys—directly reducing batch rejects and improving both overall yield and staff morale. The learning never stops: every batch, every complaint, and every unexpected yield drop gets logged and reviewed at the end of each production run.
We don’t ship material and forget about it. Our technical staff remain engaged with end users, gathering feedback on performance and troubleshooting real-world challenges. Clients in medicinal chemistry might encounter solubility hurdles or ring-opening under aggressive basic conditions; we hear directly from them and recommend modified protocols based on what we see in our plant. Some bring unconventional coupling reactions or crystal growth experiments—personal exchanges that drive us to test and improve, not simply move inventory off a shelf.
Competing intermediates line the catalogs of specialty chemical vendors. Many claim interchangeability, but we respond with detailed impurity profiles and batch-to-batch data to back up every assertion. Stories from users who switched after failed reactions stress that working directly with the manufacturer—rather than a reseller—translates into genuine advantages. We adjust drying, storage, and delivery schedules to match specific needs, overcoming the gap between factory and laboratory, and ensuring timeliness, fresh lots, and continuous improvement feedback.
Not every batch is perfect. Equipment trouble, humidity spikes, or unforeseen interactions with packaging can set back output. Being on the manufacturing floor teaches humility: it’s tempting to pretend every production run is flawless, but we’ve tackled our share of reprocesses and rush orders to cover gaps. We keep detailed records of every deviation and push for real root-cause analysis, tracing back to shifts where a change in a cooling cycle or a new lot of starting material disrupted quality.
Some researchers want the lowest cost compound, and we get requests for low-purity or technical-grade product. We decline those shortcuts for this compound, since we’ve seen long-term clients return asking for the high-purity variant after encountering side reactions or scale-up issues. Others want customization: larger lots, different particle sizes, or co-crystallization. We treat each inquiry on its own terms, but only commit to specs we can reliably produce.
The chemists who blend up a batch of 5-Chlorofuro[3,2-b]pyridine don’t lose sight of its path once it leaves our site. We look at the downstream value—how it impacts the design of drugs, agrochemicals, and advanced materials. Reactor fouling, waste minimization, greener solvents, and efficient cross-coupling reactions affect both our operation and our customers’ programs. We have used lessons learned on our own plant floor to suggest alternate bases, ligands, or purification steps, directly advising process chemists and helping them spare weeks of troubleshooting. These collaborations often outlast any single purchase order—they shape our own R&D, feed back into process refinement, and ultimately strengthen our own internal standards.
Long before quality systems became standard industry practice, we tracked lots and process histories by hand. Today, digital traceability and data archiving speed up our root cause investigations. Our customers demand full transparency, especially those regulated under cGMP or ISO systems. We take them through records from raw material intake through to final purity results, demonstrating batch reproducibility. Years of refining both human and automated oversight lead to better outcomes: less rework, more valid data, and trusted supplier relationships. We continue to refine these systems, updating batch release criteria and expanding our in-line monitoring capabilities, because every extra control step pays off in fewer downstream complications for our clients.
Our teams constantly review industry literature and our own production logs. We attend technical conferences and listen for new synthetic methodologies, always aiming to extend the utility and usability of 5-Chlorofuro[3,2-b]pyridine. Sometimes, novel synthetic routes emerge that require a tweak: a change in solvent, a slower addition, or temperature modulation. We run lab-scale experiments to reproduce new findings and jump on opportunities to offer updated technical advice. This cycle of learning ensures that the product we ship today builds on the knowledge and discipline acquired over decades, not merely the automation or software upgrades touted by less experienced producers.
We take seriously the handling and disposal of chlorinated intermediates. Beyond following rules, we proactively monitor waste streams and minimize emissions of solvents and byproducts. Local communities scrutinize our operations, and regulators demand traceable, accountable practices. We see environmental performance not just as compliance, but as stewardship: we invest in scrubbers, onsite containment, and regular environmental training programs for staff. Each improvement grows from both outside expectation and internal ethic—operators and supervisors alike know where our wastewater flows and what’s in the air after each processing run.
Many researchers consider alternatives—the closely related halogenated furans, other pyridine-based building blocks, and more exotic fused heterocycles. From our vantage, the difference plays out at the operational level. Look at reactivity, stability, and handling. A competitor’s product advertised at comparative purity came with persistent organochloride byproducts, fouling sensitive catalysts in a customer’s pilot plant. That company measured purity by one or two techniques; we cover a wider panel, identifying residuals that may escape routine screens. We calibrate our test methods against feedback from actual users, making sure the purity and reactivity support real-world results.
We invite third-party labs to analyze our product, both to reassure customers and to sharpen our process controls. Each audit or customer report gives us new targets for process adjustment. Keeping the dialogue open, admitting flaws, and engineering improvements—this is how trust grows between our manufacturing site and the scientists who build new molecules using our product.
Consistency doesn’t come from automation alone. Our staff’s commitment to detail, our continuous laboratory validation, and our open feedback with clients and auditors build reliability into every kilogram of 5-Chlorofuro[3,2-b]pyridine we ship. We take pride in knowing research projects, new medicines, and scalable production lines all benefit from the standards we uphold at every process stage. No shortcut, and no patchwork fix—just skilled labor, robust testing, responsive troubleshooting, and direct communication from the factory floor to your bench.