West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside

    • Product Name 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside
    • Alias X-Gluc
    • Einecs 611-650-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    887588

    Product Name 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside
    Common Abbreviation X-Glucoside
    Cas Number 138182-57-7
    Molecular Formula C14H15BrClNO6
    Molecular Weight 424.63 g/mol
    Appearance White to off-white powder
    Solubility Soluble in DMSO and DMF; sparingly soluble in water
    Storage Temperature -20°C
    Purity Typically ≥98% (HPLC)
    Application Chromogenic substrate for β-glucosidase detection
    Synonyms X-Glc, BCIG
    Melting Point 178-182°C
    λmax Absorbance Maxima 620 nm (for produced indigo dye)

    As an accredited 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Sigma Aldrich supplies 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside in a 1-gram amber glass bottle with a screw cap.
    Shipping **Shipping Description:** 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside (chemical grade, Sigma Aldrich/Merck/TCI) ships in sealed, moisture-resistant containers with appropriate labeling. Product is protected from light and extreme temperatures. Complies with international regulations for non-hazardous laboratory chemicals. Accompanied by a Safety Data Sheet (SDS) and delivered via reputable couriers specializing in scientific materials.
    Storage **5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside** should be stored in a tightly sealed container, protected from light and moisture. Keep at 2–8°C (refrigerator) or as otherwise specified by the manufacturer (Sigma Aldrich, Merck, TCI). Avoid exposure to air and humidity, and store in a ventilated, cool, dry area away from incompatible substances. Ensure proper labeling and avoid contamination.
    Free Quote

    Competitive 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Introducing 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside: Our Take as a Manufacturer

    The Role of Indoxyl Substrates in Modern Labs

    The jump between theory and a real working tool in a lab comes down to reliable, pure chemical building blocks. In our facility, we put long hours into refining and scaling the synthesis of 5-Bromo-4-chloro-3-indolyl β-D-Glucopyranoside, usually known simply as X-Glucoside. For labs running microbiological assays, enzyme detection, plant biology experiments, or screening genes from environmental samples, this substrate isn’t just a catalog item — it’s a bridge to clear, reproducible results.

    There’s a reason for its wide adoption. Indoxyl glucoside substrates unlock a visible color change in the presence of β-glucosidase enzymes, turning from a pale, colorless solid to a distinctively blue product after enzymatic hydrolysis and subsequent oxidation. This color information is more than cosmetic. It marks the activity of a whole class of enzymes and organisms, helping scientists and technicians confirm the presence or absence of their target within hours.

    Across the pigment-producing glucosides, we’ve worked with many: 5-bromo-4-chloro-3-indolyl phosphate (X-Phos), 5-bromo-4-chloro-3-indolyl galactoside (X-Gal), and naphthol derivatives. Only X-Glucoside targets β-glucosidase, a ubiquitous enzyme in plant and microbial biology. That unique pairing between structure and enzyme choice makes it a cornerstone for molecular biologists running gene fusion experiments (using glucuronidase as a reporter), for yeast colony screens, or for quality-control teams in the food and beverage industry tracking contamination.

    From Chemical Bench to Bulk Batches

    Lab-scale preparations never replicate the challenge of making kilogram quantities. Even a slight uptick in humidity during crystallization can send purity levels off course. For X-Glucoside, we start with pharmaceutical-grade indole intermediates, brominating with tightly controlled addition rates. Out in the plant, the smell of halogenation sticks with you, but careful ventilation, fume scrubbers, and glove protocols keep the process safe and clean. Every lot moves through glassware — not steel — to protect the sensitive indole ring from metal ion catalyzed degradation.

    Over years, we discovered that the route you use for glycosylation changes more than just overall yield. It sets the stage for batch-to-batch consistency. We stick to the Koenigs–Knorr reaction with silver carbonate, despite pressures to try cheaper but less selective catalysts. Glycosidic bond formation is finicky. It demands precise control over temperature and water traces, or side products — colorless but damaging — will appear in the final TLC and HPLC quality profiles.

    The monitored steps in our synthesis stop contaminants from entering the workflow early. Unpurified brominated indole derivatives introduce by-products that wreak havoc on color clarity during usage. Skimp on purification, and blue spots on colonies begin to look greenish, less saturated, or even diffuse. These visual distortions could mean faulty colony picking or mixed-up plate reads. In downstream biotech work, such mistakes ripple outward.

    What Consistency Means for Researchers

    Reliability doesn’t emerge from paperwork talk. Researchers and QC analysts want to see the same color, at the same intensity, after every plate lands in the incubator. Consistency is the reward for investments in raw materials, reactor cleanliness, and a genuine understanding of moisture sensitivity. Our best runs of X-Glucoside deliver a fine, crystalline powder — not a clumped mass. That’s not just visually satisfying; it gives shelf-life and precise weighing. Low water content keeps the compound stable in long-term storage at 2–8°C, and less clumping means faster dissolving, so plates get cast without side gels, streaks, or false color gradients.

    We take every batch through quantitative NMR (qNMR), HPLC, and sometimes even time-of-flight LCMS, because minor impurities can mask phenotypes or cause ambiguous colony coloration. Downstream, we get feedback from labs whose research depends on the cleanest substrate possible: medical diagnostics, transgenic plant growth, and microbial screening. All have different throughput rates, but they depend on seeing blue color as surely as their predecessors did twenty years ago.

    The careful crystallization methods we apply keep particle size in a narrow band, preventing settling or uneven spreading in agar. This level of control lifts experimental confidence, letting technical staff troubleshoot other variables rather than source their problems to reagent quality.

    How X-Glucoside Stacks Up to Alternatives

    We’ve dealt with indoxyl derivatives of all stripes. For β-galactosidase detection, X-Gal grabs the limelight. When you want β-glucuronidase, you reach for X-Glucuronide. X-Phos or NBT/BCIP gets used for alkaline phosphatase assays. For β-glucosidase, nothing tests outcomes as sharply as X-Glucoside — the blue color stands out clearly in a background of cream-white agar and yellowish colonies.

    Cost matters, but so does specificity. In our experience, simpler substrates like p-nitrophenyl-β-D-glucopyranoside (PNPG) generate yellow reactions. Color saturation falls short, and visual reads end up ambiguous under natural or fluorescent light. In contrast, the blue chromophore from X-Glucoside can be picked out from a meter away. For labs short on time and personnel, these direct visual cues lower error rates in colony picking and reporting. In automation setups or high-throughput screens, image analysis software detects blue spots with greater reliability than shades of yellow.

    Solubility in aqueous and organic solvents can trip up alternatives. Indoxyl-based substrates like X-Glucoside dissolve swiftly in dimethylformamide or DMSO, with no need to coax or heat. Commercial agar blends handle 20–100 µg/mL concentrations without precipitation or background staining. Unlike naphthol derivatives, X-Glucoside doesn’t bleed into surrounding media or induce edge artifacts on large plates.

    Why Source Direct from a Dedicated Maker

    We live with each batch of X-Glucoside in a direct, hands-on way. Every operator here has seen impurities at source impact research labs half a world away. Oversight extends beyond raw stock to container closure — we know certain plastics leach organics, so we use inert, moisture-proof containers for shipment. After controlled drying, we watch for static cling as the powder dispenses; have learned by experience that static can ruin weigh-ins in a high humidity summer.

    By controlling logistics ourselves — from purification and drying to packaging and batch documentation — the traceability of each kilogram stays rock-solid. When a researcher e-mails us about a funky color shift in an assay, we aren’t left guessing which supply chain step caused it. We trace it back through batch sheets, analytic runs, and even the humidity data from the day it was packed. We hate hand-waving as much as our end users do.

    Shifting to direct manufacturing also means small batch flexibility. Many of our best customers run custom agar blends with unusual stabilizers, or want a matching impurity profile for FDA-filed comparator studies. We don’t toss out these requests because our own synthesis starts at the gram scale and moves up, rather than coming straight from bulk barrels shipped overseas. Real customer service at the production level: it’s not just about filling minimum order quantities; it’s about understanding the stakes of each experiment.

    Why We Chose This Path: Quality Control and Staff Experience

    Making fine chemicals for demanding applications came from watching too many labs waste months fixing “minor” reagent problems. Most factory production lines seek to maximize throughput — but that trade-off punishes later users in competitive fields. We learned the hard way that running lots above a certain size opened up more batch variability. Even the time of day and the platform humidity caused measurable drift in yields or color release.

    Our best technicians have tenures measured in decades. They speak up when something in a reaction sequence looks questionable, even if the analytics haven’t shown a problem yet. This culture of hands-on oversight means we stop and restart reactions, dump borderline batches, and feed failures back into process improvements. Synthetic chemistry occupies a tough space — successes hide their effort, failures are impossible to disguise.

    Some of the earliest biotechs asked for our help reformulating agar or prepping pre-dissolved liquid solutions to save their techs time. Each request improved our internal protocols, making sure our starting material and solvents outclassed general industrial spec. These collaborations translated into tweaks in chromophore purity, drying time, and storage stability. Field experience beats marketing claims: blue means blue, every time.

    Environmental and Regulatory Realities

    Halogenated indoles come with environmental baggage if not treated responsibly. Over fifteen years, our plant engineering team phased out heavy metal catalysts, installed carbon scrubbers, and recaptured more than ninety percent of spent solvent. Waste treatment costs us time and money, but cut exposure risks to everyone else downstream. Our wastewater analytics keep regulatory agencies satisfied — and our neighbors, too.

    The difference shows up in the waste bins. Labs that use cheaper, impure chemical stocks wind up generating more hazardous waste during purification or post-plating decontamination. Using cleaner X-Glucoside reduces environmental impact for downstream users, not just at our end.

    We don’t play games around REACH or the EPA’s chemical reporting rules. Every transport document and batch slip records composition, synthesis route, and impurity burden. The trace element and metal content of every batch gets checked and certified with third-party analysis. In the event of a question or regulatory check, answers exist in black and white — not a sea of technical ambiguity.

    Customer Stories: Real Consequences and Outcomes

    Working with university labs, food safety inspectors, and biopharma startups opened our eyes to the gulf between perfect data and real-world benchwork. A single off-color plate can sideline a clinical project or shut down a process line check. We heard from one contract research lab screening for probiotic content that switching to X-Glucoside at higher purity cut down reporting ambiguity by over thirty percent. That drop meant fewer sample reruns, steadier results for their input partners, and less downtime in the verification cycle.

    For plant molecular biology teams using gene reporters, purity linked straight to regulatory approval. Regulatory bodies scrutinize every source of color development reagents. Documentation and NMR purity data shortened their audit trails by weeks. One medical diagnostics customer told us that with less batch-to-batch variance, they gained new contracts — their own customers noticed no false-negative reads during the plates’ lifetime.

    Research moves fastest when reagents are trusted and repeatable. The scientists and technicians we support deserve reliability, not surprise. Good X-Glucoside delivers on that promise plate after plate, run after run.

    Applications and Emerging Workflows

    Traditional β-glucosidase detection defines its bread and butter: colony picking, colorimetric bioassays, and gene fusion work. Over recent years, we’re seeing expanded uses: LAMP and qPCR screening, environmental monitoring of soil and water microbial content, and even next-gen sequencing prep assays for functional enzyme profiling. Each new method leans as heavily on sharp, reliable color as previous approaches, but with added demands for purity and support for automation.

    High-throughput labs now request bulk quantities or bespoke blends, sometimes demanding low-dust, rapid-dissolving grades that mix seamlessly with their preferred agar. By working alongside these development teams, we respond by tweaking physical properties — adjusting crystallization solvents, granulation speed, or post-synthesis drying regimens — fine-tuning the tradeoff between powder flow and rapid release in solution. The result is a substrate that adapts not just to classic microbiology but to emerging automated pipelines.

    The same goes for environmental and field-based workflows. Stability matters for units shipped to decentralized public health labs or deployed for rapid freshwater ecosystem checks. Our work on packaging improvements holds up shelf-life even in variable storage, helping satellite and mobile labs process samples hundreds of kilometers from the nearest central stockroom.

    What Lies Ahead for X-Glucoside Production

    Chemistry doesn’t stand still. Demand for reliable colorimetric substrates won’t drop as long as there’s testing and screening going on: water purity, food safety, genetic engineering, fundamental biology. We see requests for lower impurity grades, expanded format—pre-mixed agar, room-temperature stable granulates, fully dissolved stocks for liquid handling robots. Our R&D lab experiments with new synthetic routes, improved packing technologies, even recycling side streams for other valuable intermediates.

    The real challenge stays with consistency: as production expands, every new scale-up threatens old, trusted results. Technicians with deep, practiced intuition catch issues that digital monitors miss; as manufacturers, we must empower these team members, not sideline them. Synthesizing X-Glucoside isn’t about achieving “good enough.” It’s a constant feedback loop from customer observations, internal analytics, and field returns. Every batch is both a product and a responsibility.

    As more users expect digital image analysis to replace manual reads, the intensity and clarity of color outputs from every substrate lot will only gain in importance. We’re building not only for today’s ease-of-use but for tomorrow’s automated workflows. Bulk chemical production sounds like an industrial game — but in practical reality it comes down to one question: when a blue spot confirms a result, are we fully confident in the chemistry that created it? We focus on making sure the answer is always yes.