|
HS Code |
577740 |
| Product Name | 4-Phenoxypiperidine hydrochloride |
| Chemical Formula | C11H16ClNO |
| Molecular Weight | 213.71 g/mol |
| Cas Number | 1197-10-0 |
| Appearance | White to off-white crystalline powder |
| Solubility | Soluble in water |
| Melting Point | 187-191 °C |
| Purity | Typically ≥98% |
| Storage Condition | Store at room temperature, tightly closed |
| Synonyms | 1-(4-Phenoxy)piperidine hydrochloride |
As an accredited 4-Phenoxypiperidine hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 4-Phenoxypiperidine hydrochloride, 25g, packaged in a sealed amber glass bottle with Sigma-Aldrich label, including safety and product information. |
| Shipping | 4-Phenoxypiperidine hydrochloride (Sigma Aldrich/Merck/TCI Chemical Grade) is shipped in tightly sealed containers to prevent moisture absorption and contamination. The package typically complies with safety and regulatory guidelines, featuring appropriate labeling. Shipping involves temperature control if required and adherence to hazardous materials protocols according to destination regulations. |
| Storage | 4-Phenoxypiperidine hydrochloride should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from incompatible substances such as strong oxidizers. Keep the container protected from moisture and direct sunlight. Store at room temperature (15–25°C). Follow all relevant safety guidelines and consult the supplier’s SDS for specific handling and storage recommendations. |
Competitive 4-Phenoxypiperidine hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Working at the intersection of science and industry, our team has devoted years to refining the synthesis of 4-Phenoxypiperidine hydrochloride. This speciality compound has carved out a dependable role in pharmaceutical research, advanced organic synthesis, and in some industrial catalyst innovations. Real-world demands have sculpted our approach: purity, reproducibility, and straightforward integration into research protocols anchor everything we do.
Whether you purchase a kilogram or a drum, you receive the same consistent product each time. From procurement of raw phenolic intermediates to crystallization of the hydrochloride salt, our operations depend on well-honed steps meant for zero guesswork at the lab bench. Every batch record tracks from reactant identity through crystallization and final drying. Typical purity reaches ≥99% by HPLC and verifies against NMR and IR spectra. From an operator’s perspective, this means technicians can set aside “prep day” measurement worries. Every batch lands in the same off-white crystalline form, free flowing, and stable during shipment by air or ground.
The hydrochloride salt has proved far more manageable than the base. Handling solids, especially in bulk, means safety training is no afterthought. Over decades, we’ve fine-tuned moisture content and avoided clumping, which lets formulation chemists focus on the next synthetic step instead of breaking up caked product. Researchers in medicinal chemistry and process development come to us looking to avoid those extra headaches. Packing and sealing always get double checks for chemical integrity during transit—there are few surprises waiting at the bench, whether you’re opening our vial or drum four weeks later.
Consistency drives our approach. We produce 4-Phenoxypiperidine HCl using a tried-and-true pathway: coupling piperidine with phenol derivatives under controlled heating, monitoring the substitution pattern throughout. Targeting the para-position (the “4” position) isn’t simply a matter of textbook know-how but instead a lesson in observation and patience. Inconsistent feedstock quality always threatens to tilt that balance, so we choose vetted suppliers and back up each batch with spectroscopy. The hydrochloride is typically delivered as a crystalline powder—easy to weigh, dissolve, and incorporate into reaction mixtures or analyses.
We regularly measure melting point and moisture. In years past, failing to balance dry times with yield left us with dusts that clung to the scoops or even slightly-oily crystals that stuck to packaging—both issues we fixed by adapting our vacuum drying technique and ambient environment. Current specifications list melting point and moisture measures, but in practice, it’s the reliable texture and behavior during use that matter most in busy labs and pilot plants.
Our customers tend to fall into two camps: researchers probing drug intermediates and process engineers handling multi-liter reactors for scale-up. In medicinal chemistry, 4-Phenoxypiperidine hydrochloride often acts as both building block and key intermediate. The piperidine ring’s conformational bias delivers predictable outcomes in downstream reductive aminations or substitutions. The phenoxy substituent brings in resonance stabilization or potential for further derivatization, which is why the compound sits firmly on the list of privileged scaffolds for many discovery projects.
In our own pilot facilities, we have handled processes ranging from gram to tens-of-kilograms scale for small-molecule manufacturing. Technician experience over multiple cycles teaches clear lessons: the hydrochloride salt dissolves evenly in polar and mixed solvents, mitigating local precipitation and clogging in reactors or glassware. Some customers attempted to use the base instead—only to find that their process water layers separated unpredictably. Years of supporting these scaling projects gave us firsthand evidence that the hydrochloride form not only streamlines purification stages, it prevents frustrations later in workflow.
Comparisons often mean hard numbers for solubility, purity, or reactivity, but the reality is it is day-to-day experience that reveals most. We’ve tested batches from alternate producers over the years. Some shipped lightly colored, slightly sticky powders—flagging incomplete neutralization or over-drying. Others carried faint off-odors from residual starting material, which can cause headaches in regulated industries. From direct feedback, our clients appreciate not only meeting chemical specifications but running their own HPLC and finding the same peak heights every time.
There isn’t room for shortcuts with piperidine derivatives in regulated R&D settings. Pharmaceutical teams report that having to retest each shipment not only wastes budget but risks entire development timelines. We run stability studies under real and accelerated conditions—at the end of six and twelve months, our hydrochloride salt keeps its physical properties and purity scores. It stays manageable in standard laboratory conditions for extended periods, improving project flexibility, because customer feedback drove us to validate every assumption.
Drug development steps don’t forgive guesswork. Any off flavor, color, or inconsistent handling quality in the starting material can snowball into failures or delays at the later stages of synthesis. We have spoken to teams frustrated by salt forms that yielded erratic data or failed to dissolve at expected rates. Each complaint about another manufacturer’s batch led us to redouble internal batch controls—from sieve analysis to dynamic vapor sorption measurements. By focusing effort here, we ensure the hydrochloride powder flows freely from the first scoop, weighs accurately, and disperses evenly—a difference that shows up in analytical reproducibility and process mass balances.
Over time, we found even minor tweaks in downstream isolation—like adjusted precipitation temperatures or filtration rates—can have big effects downstream. One customer tried another vendor’s material and burned hours scraping caked product from glass, only to land on an incomplete isolation because the profile wasn’t right. Our manufacturing process aims for salts that remain free of hydrate forms and show stable melting characteristics run after run. This level of reliability reduces downtime and keeps teams focused on their core research instead of cleaning or troubleshooting.
Early in our manufacturing history, we fielded issues with static buildup in powder handling. We implemented grounded filling stations and anti-static packaging to overcome dusting and clumping. It sounds trivial, but lab technicians handling tens of bottles each day appreciate being freed from awkward cleanup and time-consuming anti-static wipes. These process-level changes only became apparent through volume use, which traders or brokers seldom see firsthand.
During scale-up, moisture remains a silent liability for hygroscopic salts. We control humidity in the last stage of packaging by modifying our cleanroom environment so that each pack arrives dry and remains flowable at the customer site. Direct debugging in the plant led to tighter environmental controls and ultimately less product returned for caking issues. The little inconveniences—sticky scoops, bottle residue, inconsistent pours—got engineered away, not just because of a specification but because of shared feedback up and down the chain.
Many research groups pursue analog synthesis, where subtle differences in starting materials can shift a campaign’s trajectory. We have seen dozens of projects adjusting simple parameters, only to learn that apparent outliers often come down to material variance. We partner closely during custom synthesis, sharing spectral and performance data pre-shipment. Feedback from startups and established R&D teams directs small but tangible improvements, whether in subdivision sizes, bottle types, or batch reporting.
Academic and industrial medicinal chemists, especially those chasing new CNS-active compounds, return to us for repeat runs. They recognize that jumping from a gram-scale experiment to multi-kilogram loads brings new challenges—filtering, drying, and dissolving can turn into bottlenecks if materials underperform. Our ongoing investment in analytical validation—in-house and with third-party labs—anchors our reputation for dependability. With confidence in every shipment, research groups can focus creativity and technical expertise where it counts most.
Our team faces strict regulatory expectations both from our partners and as members of the chemical manufacturing sector. We took early steps to minimize waste streams through solvent recycling and byproduct reclamation, based on years of process optimization runs. Local environmental restrictions encouraged us to adopt contained synthesis vessels and robust effluent treatment, all documented in our internal compliance manuals. Through transparent reporting and supplier checks, we create an environment that prioritizes both product purity and minimized environmental impact.
Continuous training helps plant and lab personnel identify risks early and responsibly handle, store, and ship all chemical products. We work closely with our local community on emergency response readiness. In the bigger picture, our standard for supporting worker safety proves as essential as keeping product at high purity. This responsibility broadens beyond chemical metrics and rests in our workforce culture and direct engagement with the broader society.
We keep our focus fixed on the details that matter. In every production cycle, someone from our team works hands-on with the manufacturing line. This presence offers firsthand oversight; minor problems get flagged early; process tweaks or analytical checks happen before a full batch ships out. Over time, this hands-on vigilance together with smart process design prevents headaches for formulations, blending, or downstream derivatization. Every kilogram we deliver reflects lessons gathered across countless production runs and customer conversations.
No matter which project or scale, getting the right starting material remains critical for hitting timeline and budget targets. We don’t take chances with rush orders or cut corners based on cost alone. Our record for stable supply throughout disruptions—whether regulatory, logistic, or market-driven—hinges on relationships forged with buyers who trust our process. Each batch of 4-Phenoxypiperidine hydrochloride gets the same care and scrutiny, whether it’s headed for a single research bench or a pilot plant preparing to scale a promising breakthrough.
Openness makes a difference. Each researcher, project manager, or process engineer brings unique questions, and our technical staff responds based on real-world usage and production experience. Over years, this cumulative knowledge helps everyone—from a graduate student tackling a new synthetic route to an engineer overseeing multi-batch API runs—arrive at workable, repeatable outcomes. Product support remains ongoing: if unique solvent or crystallization advice is needed, we work through solutions side-by-side.
We have helped clients adjust reaction conditions or integrate intermediate storage steps to take full advantage of the hydrochloride form’s stability. That means sharing our own analytical data and, when helpful, developing new test protocols to answer specific challenges. This collaboration strengthens not only our internal benchmarks but ultimately feeds back improvements that benefit all users. By standing behind our 4-Phenoxypiperidine hydrochloride’s performance, we foster trust and continued progress in every field that relies on this reliable chemical building block.