HS Code |
193931 |
| Product Name | (4-Fluorophenyl)acetic acid hydrazide |
| Cas Number | 329-41-5 |
| Molecular Formula | C8H9FN2O |
| Molecular Weight | 168.17 g/mol |
| Appearance | White to off-white solid |
| Melting Point | 122-125 °C |
| Solubility | Slightly soluble in water; soluble in organic solvents |
| Smiles | C1=CC(=CC=C1CC(=O)NN)F |
| Inchi | InChI=1S/C8H9FN2O/c9-7-3-1-6(2-4-7)5-8(12)11-10/h1-4H,5,10H2,(H,11,12) |
| Storage Conditions | Store at room temperature, keep container tightly closed |
As an accredited (4-Fluorophenyl)acetic acid hydrazide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | (4-Fluorophenyl)acetic acid hydrazide, 5g, is supplied in a sealed amber glass bottle with a white screw cap and labeling. |
| Shipping | Shipping of (4-Fluorophenyl)acetic acid hydrazide (Sigma Aldrich/Merck/TCI, chemical grade) is carried out in compliance with stringent safety regulations. The product is securely packaged in airtight containers, labeled with hazard information, and shipped via certified carriers to ensure safe and efficient delivery, adhering to local and international transport regulations. |
| Storage | (4-Fluorophenyl)acetic acid hydrazide should be stored in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible substances such as oxidizing agents. Keep the container tightly closed when not in use. Store at room temperature (15–25°C), protected from light and moisture. Use appropriate personal protective equipment (PPE) when handling the chemical. |
Competitive (4-Fluorophenyl)acetic acid hydrazide prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
In our production plants, we see thousands of compounds take shape. Among them, (4-Fluorophenyl)acetic acid hydrazide represents both subtlety and adaptability, exemplifying the importance of quality controls at every step. Chemists like ourselves, accustomed to keeping a vigilant eye on each reaction, know the difference even tiny process shifts make when dealing with sensitive building blocks. This compound, a white to off-white crystalline material, brings together the precision of p-fluorination with the reactivity of a hydrazide group. We produce it under strict temperature and humidity controls, as both the aromatic structure and hydrazide moiety can show robust interaction with the environment. In our experience, handling and storage rapidly influence the compound’s behavior — imperfections in batches often show up as minor color shifts or inconsistent melting points, details a trader rarely mentions but a producer can’t ignore.
Chemically, (4-Fluorophenyl)acetic acid hydrazide arises from the hydrazinolysis of methyl 4-fluorophenylacetate. This transformation takes an ester and swaps its reactivity, allowing the hydrazide to participate in subsequent synthetic steps. Our reactors operate on a batch system, monitored with online HPLC and NMR snapshots, as the endpoint cannot be trusted to color alone. The manufacturing process rewards routine but keeps everyone awake — even a few degrees difference at reflux can impact yield, not just quality. Seasoned operators notice these variances and adjust, ensuring the process concludes at optimal purity.
Our current main model for (4-Fluorophenyl)acetic acid hydrazide focuses on purity above 99% by HPLC, a moisture content below 0.5%, and clear documentation for lot-to-lot consistency. This isn’t an arbitrary threshold; customers report that subtle impurities, especially residual methyl ester or unreacted hydrazine, introduce noise in their screening assays and impact downstream chemistry. Each batch includes both NMR and HPLC signatures, along with FTIR analysis, so any research team can feel the confidence we expect in our own laboratory. Chemists who have coped with less controlled samples understand the importance of a reliable supplier. The subtlety of the para-fluoro group — which seems simple in theory — plays a critical role in activity tuning for pharmaceutical research, and small changes in purity or solvent residues make a tangible difference during SAR expansion.
Moisture presents one of the most persistent production challenges. Hydrazides tend to absorb atmospheric water, and the shelf life of a poorly dried batch becomes unacceptably short. We use low-temperature vacuum drying, and we always package under inert atmosphere. With our model, users in medicinal research, agrochemical development, and advanced material synthesis avoid solubility inconsistencies. Clients working with high-throughput screening notice less variability when purity and dryness are guaranteed; feedback loops from these researchers have refined our post-processing and packaging steps.
From the outside, (4-Fluorophenyl)acetic acid hydrazide appears interchangeable with regular phenylacetic acid hydrazide — just a single atom changed. On the factory floor, the compound’s para-fluorine changes everything. During our own screening work, adding the electron-withdrawing fluorine shortens reaction times in subsequent couplings, especially for acylhydrazone formation. Downstream, synthetic chemists rely on such subtleties to optimize routes to active pharmaceutical ingredients or advanced probes. This means that impurity profiles not only affect direct use but also influence byproduct formation down the line. We track each shipment’s certificate of analysis and tie it directly to real product performance in our own application lab; it saves headaches and recalls.
We use batch records and QA logs to drill into these differences. While methyl or chloro substitutions elsewhere on the ring look similar in a catalog, their chemical behavior in R&D projects varies. In our hands, (4-Fluorophenyl)acetic acid hydrazide offers more pronounced shifts in electron density, and experienced development teams exploit this effect to drive selectivity and potency in bioactive molecules. Chemists attempting to make similar hydrazones, triazoles, or pyrazolines with unsubstituted aryl hydrazides have reported lower yields, less predictable side products, or more troublesome purification. A single batch prepared without careful temperature ramping sometimes leads to yet-unnoticed differences in screening campaigns.
Our plant rarely receives one-off orders for (4-Fluorophenyl)acetic acid hydrazide. Requests usually come from pharma process development, fine chemical companies, or contract research organizations, who need stability and reproducibility batch after batch. The hydrazide group opens up coupling opportunities that nitriles or amides simply can’t offer — aromatic hydrazides form acylhydrazones efficiently and handle mild reaction conditions, minimizing degradation for sensitive fragments.
We consult frequently with users tailoring compound libraries or chasing lead compounds with SAR modifications. Revising a benzene ring from hydrogen to fluorine changes the metabolic fate of an entire scaffold, impacting not just biological activity but also ADME properties. Our tech support staff, many with bench experience, troubleshoot applications where lots from other suppliers have failed because of microimpurities or out-of-spec solvent content.
At scale, the hydrazide becomes a platform for transition metal–catalyzed couplings, rapid derivatizations, or formation of labeled materials for mechanistic studies. Because each stage downstream relies on purity, we trace every drum from reactor through to storage, making our process documentation available all the way to the chemist receiving it. Trust doesn’t arrive by courier — it’s built with every repeat order, every answered question, every flagged deviation report.
Each year, customers come up with new and creative ways to challenge the boundaries of this compound’s use. Large-scale users drive us to reconsider throughput rates and drying conditions, asking for kilograms with tight timelines. In these cases, process reliability becomes everything; missed endpoints or temperature control mistakes cascade into rework costs and lost time. We’ve updated our plant’s solvent recovery systems and analytical tools not just for higher output but for more reliable product each cycle.
Hydrazine-based chemistry always brings up safety. With decades of handling hydrazides and related materials, our plant design features closed transfers, negative pressure reactor zones, and trained team members at every step. Each improvement in production safety carries through to agencies, customers, and the environment. In the last three years, we have reduced solvent wastage and improved our containment procedures in response to stricter regulations and our own best practices audits. Discussions with neighboring plants, and sharing insights at industry working groups, keeps us ahead of compliance risks before they reach our door.
Chemical manufacturing, particularly on the specialty or research scales, always comes with a burden. Those of us working with hydrazine derivatives navigate waste management, emission controls, and safe disposal daily. Our team is acutely aware of the need to minimize releases, so our reactors use solvent-recycling procedures and we constantly search for greener alternatives. Over the past five years, process chemists on our staff have converted three steps in the upstream synthesis to less hazardous protocols and improved our yields with lower solvent volumes.
We treat waste at the source with purpose-built neutralization and filtration systems. Our commitment to transparency with auditors and regional agencies comes straight from the sense of stewardship that seasoned manufacturers understand — cutting corners inevitably surfaces in product quality and long-term exposure risks. Real sustainability improvements only come from process design, not slogans. Benchmarking ourselves with both local and international standards has brought steady year-over-year reductions in our resource consumption, and these improvements directly benefit our customers through pricing and reliability.
Seasoned formulators know that product doesn’t just “arrive” at the point of use — it navigates shipping, storage, and repackaging. (4-Fluorophenyl)acetic acid hydrazide can degrade under improper conditions, so we pack each lot under inert nitrogen and use tamper-evident seals. Our warehouses feature humidity and temperature recording at every stage; actionable alerts and regular checks minimize the chance of product drift before final delivery.
Unlike generic resellers, we field technical queries about every bottle. Researchers call us directly to discuss storage tips, dissolution quirks, and experiences with different analytical methods. Outliers are rare, but every manufacturer knows that product recalls or batch failures on the customer side can damage hard-won trust. We respond with replacement batches at our expense and carry out root-cause investigations in tandem with the customer’s own QC team, feeding results back into our own documentation and procedures.
Our transactional relationship with customers quickly grows into a partnership through these exchanges. We adjust our packaging and labeling based on customer needs, ranging from bulk fiber drums for large process runs to amber vials for sensitive research applications. Fine-tuning the supply chain means knowing the actual people using our compound — and they frequently teach us as much as we teach them. Every change, from label orientation to lot number size, came from an actual request or issue encountered while using the compound under pressure.
The needs of the industry don’t stand still, and neither do we. More advanced medicinal chemistry workflows, automation in parallel screening, and specialized agrochemical development ask for increasingly tailored chemical intermediates. We have several internal projects underway to expand our offerings of functionalized hydrazides, building on the robust platform developed for (4-Fluorophenyl)acetic acid hydrazide. Our knowledge and production experience feed directly into these innovations, not just from literature but from feedback and partnership with top research teams worldwide.
Improved analytical methods, such as Benchtop NMR, high-sensitivity MS, and advanced X-ray crystallography, have allowed us to set tighter process controls and deliver higher confidence certificates of analysis. These aren’t marketing buzzwords or simply “value adds” — they grew from customer demands to eliminate variability in screening campaigns. The bar gets raised with every FDA or EMA inquiry about precursor impurities, and by rapidly evolving academic research that uncovers new targets and mechanisms of action.
Our process improvements always start with pilot-scale adjustments. We test alternate purification steps, better drying regimens, and new packaging configurations based on actual shipment returns and user surveys. Each change to our process happens because of a metric: fewer customer complaints, fewer out-of-spec batches, higher reported yields in customer applications.
Working day in, day out at the source, we build up a real sense of what (4-Fluorophenyl)acetic acid hydrazide brings to the table. Its uniqueness doesn’t come from a single property or clever advertising scheme, but from lived experience with its quirks, its strengths, and its place in complex synthetic routes. Users aren’t just buying grams or kilograms of chemical — they are relying on us to supply stable, reliable, and characterized material that fits seamlessly into their workflow. Every feedback cycle, every deviation notice, and every success story leaves a mark on our production and on our commitment to precision.
We continue to learn from users at the bench, in the plant, and in the field. From early-stage startups to multinational pharma firms, those who demand robust, dependable intermediates know where to find us. Our history with (4-Fluorophenyl)acetic acid hydrazide is measured not in tons shipped, but in discoveries made, problems solved, and partnerships built.