HS Code |
270747 |
| Chemical Name | 4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic acid |
| Common Name | HEPPS |
| Molecular Formula | C9H20N2O4S |
| Molecular Weight | 252.33 g/mol |
| Cas Number | 16052-06-5 |
| Appearance | White crystalline powder |
| Pka | 8.0 at 25°C |
| Solubility In Water | Very soluble |
| Buffering Range | 7.5–8.9 |
| Storage Conditions | Store at room temperature, tightly sealed |
As an accredited 4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic Acid [Good's buffer component for biological research] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | White, moisture-resistant plastic bottle with screw cap, labeled “4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic Acid, 100g, Sigma-Aldrich, research grade.” |
| Shipping | Shipping for **4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic Acid** (Good’s buffer, Sigma Aldrich/Merck/TCI grade) is typically carried out at ambient temperature in well-sealed, chemical-resistant containers. The packaging adheres to regulatory standards for laboratory chemicals, ensuring stability and safety during transit. Expedited shipping is available upon request for urgent research needs. |
| Storage | 4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic acid (HEPPS, a Good's buffer) should be stored tightly sealed in a cool, dry, well-ventilated area, away from moisture, heat, and incompatible substances. Store at room temperature (15–25°C) and protect from light. Avoid contact with strong oxidizing agents. Keep container tightly closed and clearly labeled, following standard laboratory chemical storage protocols. |
Competitive 4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic Acid [Good's buffer component for biological research] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Researchers who work daily with buffers trust certain compounds for a reason. Our own experience producing 4-(2-Hydroxyethyl)-1-piperazinepropanesulfonic acid, often called HEPPS, has shown how much precision and quality mean to the scientific community. This buffer stands out among the family of Good’s buffers, not because of clever marketing, but for its consistent ability to maintain conditions that experiments demand. In protein chemistry labs, clinical research, and industrial fermentation, HEPPS keeps essential reactions under control by offering a stable pH range that’s tailored to the unique needs of biological systems.
There are many buffer systems available, but few match the reliability required in modern molecular biology. Mistakes in buffer composition can set entire research projects back by weeks. As manufacturers, we constantly field requests from researchers who have learned, sometimes the hard way, that raw material quality and process consistency make or break their results. It’s not simply about purity on paper; the biological impact speaks volumes. Our quality monitoring rigorously tracks every production batch, and we frequently hear from labs that repeat experiments with our buffer to confirm reproducibility.
Producing a Good’s buffer like HEPPS is about more than hitting a percentage on a purity certificate. From raw materials to final packaging, each step is designed to eliminate contaminants—whether that means trace metals, unreacted starting materials, or byproducts that slip through less careful processes. Technical teams in our plant have decades of combined experience refining our methods, often drawing on direct feedback from researchers who detect even the smallest variance in their results. It is one thing to make a buffer to specification. It is another to make a buffer that is trusted—reliably, batch after batch.
HEPPS, as a zwitterionic buffer, brings real advantages over alternatives. Our clients in protein research often highlight its low absorbance in ultraviolet regions, making it a preferred choice for spectrophotometric assays. Enzyme assays turn especially sensitive in the presence of UV-absorbing compounds. Buffers stray from “background” conditions and the data skews. That’s not a theoretical risk; it’s one that experienced researchers see in spectra every week. Each pound we ship is the result of methodical purification, tested against standards that have come from direct collaborations between our manufacturing division and working biochemistry labs.
We often hear from scientists who struggle with batch-to-batch variability when using low-grade buffers. In our manufacturing process, granular control over reaction conditions means the pKa value of every batch lands where researchers expect—in the optimal range for their assay, usually around pH 8. That tight range ensures enzymes, cells, or proteins behave as predicted, day after day. In less controlled buffers, pH drift and ionic contamination throw variables into experiments that can’t withstand surprises. For example, if a buffer contains unfiltered ions like sodium or potassium from upstream processes, it can change the ionic strength of cell culture media. That minor slip only shows up later, when yield drops or biomolecule properties shift unexpectedly. Years in production have taught us to take those lessons to heart, embedding strict checks to strip out what doesn’t belong.
From time to time, new buffer formulas enter the market with promises of lower cost or novel features. Through conversations with our technical support team, some clients have tried these alternatives, only to return after their cells didn’t grow properly or their antibodies bound less efficiently. HEPPS isn’t just another ingredient on a safety data sheet; it’s central to proving hypotheses or maintaining GMP compliance in medical labs. We’ve seen the industry’s demands change—higher throughput screening, more complex biomaterials, and tighter regulations—but the value of a reliable buffer has not diminished.
Over decades of supplying HEPPS directly to global laboratories, we have listened closely as users compare this compound to similar buffers. Many consider buffers like HEPES, PIPES, or MOPS depending on their specific assay and organism. What sets HEPPS apart is the careful balance of its buffering capacity with biological compatibility. It resists interference with cellular processes at working concentrations, unlike some classical buffers which, while effective in simple inorganic systems, can cause cytotoxicity or obscure results in living cultures. Its pKa near neutrality permits use in mammalian cell cultures or protein crystallization, two areas where unwanted side reactions from buffer breakdown can completely invalidate research.
Another difference frequently raised by those at the bench: HEPPS’s lower metal chelation enables smoother use in solutions that require tightly defined metal ion concentrations. Our production line minimizes traces of metal impurities because we know even parts per million can affect enzyme kinetics or cell viability. Manufacturing oversight, from synthesis through to packaging, revolves around conversations with end users—biologists who have spent weeks optimizing a single protocol only to find a hidden buffer contaminant wrecks a month’s work.
Some labs ask us to explain why HEPPS appears on more reagent lists in genomics and proteomics workflows. Unlike traditional phosphate or Tris buffers, HEPPS offers lower temperature sensitivity. This steadiness guards against shifting pH as instruments warm and cool. When results matter, especially in high-throughput or automated workflows, the certainty that a buffer won’t add new variables gives researchers confidence to explore and innovate. Their questions push us to refine our own processes and improve every lot.
Manufacturing to specification forms the foundation of trust between our company and the research community. For HEPPS, that means more than just delivering a white, crystalline solid in a drum. It means validating, with every lot, parameters like water content, optical absorbance, heavymetal traces, pH stability, and solubility under stringent assay conditions. We run both chemical and biological tests, frequently in direct consultation with external labs, to ensure that the practical performance matches the numbers. In our case, the dialogue with customers has shaped our internal QC: before final release, we test our product not only under standard lab conditions, but also in high-sensitivity applications like PCR and cell culture, where contaminants trigger immediate feedback from rigorous users.
A buffer’s success ties directly to purity levels, and we measure against international standards, not simply local minimums. For instance, our top-grade HEPPS consistently meets or exceeds 99% purity by HPLC analysis. This is not just a marketing point—it means trace side-products and precursors are left out, so downstream reactions can proceed without unforseen enzyme inactivation or byproduct formation. If a buffer contains organics or ions outside the norm, that can show up as subtle shifts in experiment reproducibility—the sort of problem that for years went undiagnosed until improved analytical technology brought it to light.
Our technical support specialists often consult with customers troubleshooting complex immunoassay or sequencing workflows. In these cases, even sub-ppm levels of certain aldehydes or amines cause spike—and fade—patterns in data that a less tuned manufacturing process would never catch. Engineering our process for maximum consistency means chemists and biologists can rely on our buffer not only for publication-grade experiments, but also for regulated diagnostic development.
HEPPS dissolves rapidly in water and produces clear, colorless solutions—a feature directly requested by high-throughput screening facilities. For applications using multiwell plates or optical detection, the clarity of a preparation affects baseline readings, especially when comparing across hundreds or thousands of wells. Time after time, labs working with us to establish assay acceptance protocols cite the clean solubility and minimal foam, letting their robotics run efficiently with less wasted sample. This kind of steady feedback has shaped how we granulate and package HEPPS, always following real-world lab workflows instead of theoretical models.
Our role as a manufacturer goes beyond producing high-quality HEPPS; we’re equally invested in the broader logistics challenge laboratories face around the world. One common pain point we hear about concerns disrupted timelines, inconsistent packaging, or material handling errors from less experienced suppliers. Unlike traders or bulk distributors, we maintain direct line-of-sight from sourcing of piperazine starting materials through to labeling and delivery. A delayed shipment or a batch compromised in transit represents a real risk to research projects where every day matters. We maintain warehouse and transport infrastructure focused on speed and traceability because we have seen, over many years, how sudden research breakthroughs—or critical diagnostics—depend on materials showing up on time, in full, and with the integrity untouched.
Many underappreciate the degree to which undetected changes in process or packaging can affect a buffer’s usefulness. Moisture ingress, static charge from plastic, or batch mixing during shipping can all introduce variables downstream. Our sales and technical staff work side-by-side with shipping teams, and together we monitor every lot number to enable rapid identification and replacement if anything seems off. Experience tells us this level of care doesn’t just pay off when something fails—it builds real partnership with research teams, who see us as a source of reliability rather than just another vendor.
We keep our doors and lines open to scientists, not only for troubleshooting but for collaborative improvement. Countless features of our current HEPPS product line come from direct feedback: smaller packaging options for field kits, anti-static liners for dusty environments, improved batch tracking for GMP users, and refinements in granulation for automated dispensers. One plant manager keeps a thick binder of suggestions from molecular biologists, analytical chemists, and even students—a sign that we’re doing more than just following regulatory templates.
This cycle of feedback often moves faster than changes in international standards. Labs bring us their most demanding scenarios: prolonged incubations, trace contaminant screening, or simultaneous multi-assay batching. In turn, we invest in process improvements. Upgrades in analytical instrumentation, improvements in material handling, and more sophisticated automation have led to fewer out-of-spec batches and faster turnarounds. As manufacturers, we see the frontline impact of these adjustments in fewer complaint calls, more repeat business, and, most importantly, higher success rates for the researchers who trust us.
The landscape for biological research constantly shifts. Fields like synthetic biology, regenerative medicine, and next-generation sequencing all spring from a foundation of stable, robust lab conditions. Good’s buffer components, including HEPPS, form a critical link between the chemical purity we deliver and the transformative therapies or technologies emerging from today’s research labs. Our manufacturing team understands this responsibility. With every iteration—whether we’re optimizing for large-scale fermenters or small diagnostics kits—the demands and stakes have risen. In early 2000s, a university client reported discrepancies in high-throughput screening when switching between suppliers. By tracing the issue to subtle buffer impurities, both our teams adopted new detection methods improving both their research and our quality standard, setting a pattern of mutual progress.
Recently, we’ve supported groups developing antibody-based diagnostics for new disease targets. These clients require not only stable physicochemical performance, but also full analytical documentation, batch histories, and regulatory support behind every shipment. We ensure HEPPS production and quality assurance incorporate these modern requirements, not out of obligation to standards, but out of direct conversations where a few micrograms of a contaminant would derail years of work. Our senior chemists regularly participate in industry forums to both present our learnings and learn from others, ensuring we remain agile and responsive to changes in best practices.
Over the years, we have collaborated with teams facing routine and novel challenges. Some of the most valuable relationships start with a request for help—coping with unusual cell lines, troubleshooting enzyme degradation, or developing new instrumentation that pushes buffer components into unfamiliar regimes. The product development and quality control team analyzes feedback, runs batch tests under these new conditions, and delivers modified product where needed. Whether a customer’s concern is chemical - such as ensuring low endotoxin content - or logistical - such as adapting packaging to avoid vacuum crushing in air transport - our manufacturing team lives these challenges every day.
One recurring issue we help troubleshoot relates to changes in laboratory methods. As automation and scale-up gather pace, many researchers push their materials well outside textbook use. With precise process documentation, we trace process adjustments and offer tailored solutions. Often, this leads us to tweak production runs—adjusting washing processes, or adding steps in impurity filtration—to keep up with new standards of purity and consistency. Staying ahead of issues, instead of just reacting, shapes our entire team culture.
Supplying HEPPS to the world’s biological research community is not just about solvents and reactors, but about years of relationship-building around mutual trust and respect for reliable science. Each container, large or small, passes through hands trained to view the product through the eyes of scientists under pressure to deliver publishable, reproducible results. The product’s value comes not from promotional claims, but from day-in, day-out feedback from laboratoires who see the difference in their controls, their throughput, and, ultimately, their ability to answer scientific questions that matter.
For teams striving to push forward the frontiers of cell biology, genetics, or biopharmaceutical development, a buffer like HEPPS is more than a routine purchase. It’s a key building block of scientific progress, connecting complex, innovative processes to the bedrock reliability manufacturers can provide through focus, collaboration, and dedication to continuous improvement. We stand behind every batch, not only with documentation, but with a team ready to listen, adapt, and learn alongside the scientific community we serve.