West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt

    • Product Name 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt
    • Alias CAPSO-Na
    • Einecs 253-404-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    463838

    Product Name 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt
    Abbreviation CAPS-Na
    Chemical Formula C9H18NNaO4S
    Molecular Weight 259.30 g/mol
    Appearance White to off-white powder
    Solubility Highly soluble in water
    Ph Range 9.7 - 11.1 (0.05 M solution at 25°C)
    Cas Number 113303-27-6
    Storage Temperature Room temperature (15-25°C)
    用途 缓冲剂 (Buffering agent)
    Maximum Absorbance None significant above 240 nm
    Stability Stable under recommended storage conditions
    Synonyms Sodium 3-(Cyclohexylamino)-2-hydroxy-1-propanesulfonate
    Melting Point Decomposes before melting
    Grade Biotechnology or Molecular Biology grade

    As an accredited 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing White, opaque plastic bottle labeled "3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt, 25g, Sigma-Aldrich," tamper-evident seal, screw cap.
    Shipping Shipping for 3-Cyclohexylamino-2-hydroxypropanesulfonic acid sodium salt (Sigma Aldrich/Merck/TCI, chemical grade) is typically carried out in tightly sealed containers to prevent moisture uptake. The product is shipped at ambient temperature, labeled appropriately for laboratory chemicals, and complies with relevant safety and transport regulations for non-hazardous substances.
    Storage 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt should be stored in a tightly closed container, in a cool, dry, and well-ventilated area. Protect from light, moisture, and incompatible substances. Recommended storage temperature is typically at 2–8°C (refrigerated). Always follow the manufacturer's guidelines and local regulations for chemical storage and handling.
    Free Quote

    Competitive 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt: Our Perspective from the Production Floor

    Bringing Precision to Buffer Chemistry

    Every so often, in the course of manufacturing specialty chemicals, something lands on the production schedule that carries a quiet importance in research and diagnostics. For years, our team has handled the synthesis of 3-Cyclohexylamino-2-hydroxypropanesulfonic Acid Sodium Salt (commonly called CAPS-Na or CAPS Sodium Salt), not because it's glamorous, but because reliable buffer capability matters for so many biotechnological and analytical applications.

    What Sets This Compound Apart in Practice

    CAPS-Na doesn’t compete for attention like the classic biological buffers—Tris, HEPES, or MOPS. Instead, it gets chosen because it performs cleanly at high pH, often where others fall short. Its structure, with a cyclohexylamino group, pushes the pKa up around 10.4, which opens a space in the buffer repertoire. For manufacturers like us, it’s never just about achieving specifications on a sheet; it’s about hands-on process control to ensure each batch gives researchers the consistency they trust year after year.

    Our factory has worked with hundreds of buffer compounds over decades. Many of these, like CAPS-Na, began as niche requests and evolved into staples for people working in protein chemistry and enzyme assays. The control we maintain isn’t just about purity—though consistently getting 99%+ is something we track closely—it’s also about making sure our customers don’t see day-to-day variation in how the buffer behaves in practice.

    CAPS-Na in Biochemical Workflows

    Making CAPS-Na on scale is less about volume and more about repeatability and accountability. It sees the most use in protein electrophoresis and capillary sequencing, especially as a buffer in SDS-PAGE at alkaline pH. Many academic papers and technical manuals recommend CAPS-based systems whenever researchers want to avoid buffer breakdown or interference above pH 9.0, particularly during transfer steps and in western blot protocols.

    Diagnotistic kit producers also favor CAPS-Na for immobilization buffers, ELISA plate washes, and other scenarios where even buffer performance is more important than just meeting a spec. Most users—down the line—never give a thought to where their buffer salts originate, but our manufacturing team knows how critical each lot becomes for these downstream applications.

    Raw Product, Batch Quality, Real-World Differences

    We didn’t start by making CAPS-Na; it was a decision that grew from the urgencies of life-science customers. We learned early that inconsistent color, variable particle size, and trace contaminants can spoil what should otherwise be a straightforward experiment. These complaints drove us to rethink filtration, particle finishing, and sodium conversion steps. The result is a manufacturing setup that minimizes batch-to-batch drift, chasing after what matters most to scientists: no surprises at the bench.

    Years of technical feedback taught us that researchers expect their buffer to simply work. Once, a university client notified us about subtle shifts in electrophoresis migration, tracing the culprit back to minor variances in CAPS-Na lots from a different supplier. This reinforced our own investment in tighter process control, continuous monitoring, and full transparency on each batch’s analytical results. Reliable pKa, solubility, and negligible absorption at 260/280 nm are not just numbers—they’re tests our team runs on every production cycle to guarantee that a researcher opening a fresh bottle can trust their protocol to behave as expected.

    Experiences in Manufacturing: Batch Stories and Realities

    Scaling up production introduced challenges that technical sheets rarely mention. For instance, residual sodium was regularly a thorn for many outfits trying to shift from the free acid to the sodium salt cleanly, without leaving mother liquor contamination. Our initial attempts led to several lots with white, free-flowing powder that clumped under humidity. A doubled vacuum-drying cycle and rigorous moisture testing changed that outcome.

    Cation exchange columns and fine filtration steps put a heavy strain on our plant equipment, especially given the lower tolerance for iron, chloride, or biologically active contaminants in buffer-grade material. Rather than just relying on raw material vendor claims, we began source tracing every lot of cyclohexylamine and glycidol, tracking reactivity down to each input. Our laboratory now runs every batch through chromatographic fingerprinting, not because regulations demand it, but because protein scientists and immunoassay kit developers expect unshakeable purity.

    Day-to-Day Considerations: Not Just Boxed Chemistry

    Labs ordering CAPS-Na often request the product in bottle sizes that match workflow and sensitivity to moisture. We've seen that clumping or caking, often caused by trace water content, stalls pipetting routines and annoys researchers facing time crunches. In response, we adopted fresh desiccant packaging, improved storage environments, and even offer bulk vacuum-sealed drums to industrial buyers. Many buffer salts can pass a specification test; few endure field use without complaints unless small manufacturing decisions prioritize real-world usability.

    A typical batch run starts with reagent inspection and small-scale pilot crystallization. Early in the process, visual and chemical screening sorts out any off-grade intermediates. Consistency in color and bulk density gives a fairly reliable early warning system, long before final packaging or analysis confirms a batch’s top grade. This culture of preventive assessment saves us and our customers headaches months later.

    Why CAPS-Na, Compared to Other Buffer Salts

    Plenty of buffer salts claim low UV absorption, broad chemical compatibility, and strong performance under denaturing conditions. In our manufacturing experience, CAPS-Na stands apart for its stability and minimal background in sensitive photometric assays. The cyclohexyl substitution brings steric stability, resisting oxidation or unwanted side reactions that can plague more basic buffers. Tris, as a comparison, tends to be unstable over time at elevated pH, generating drift and side reactions. CAPS-Na, in rigorous field and laboratory tests, simply refuses to break down or introduce artifacts.

    Some labs still try to use carbonate buffers at high pH or resort to borate systems. These alternatives may be cheaper or more familiar, but they rarely provide the kind of reproducibility demanded by modern enzyme kinetics or ultra-trace protein work. Our own batches of CAPS-Na consistently draw customer feedback regarding their long shelf life and absence of insoluble residues, a frequent headache with alternative salts. Even after repeated opening and exposure cycles, our standard packaging resists degradation thanks to mill-side moisture controls—a detail that emerged from dozens of customer support calls and production audits.

    Specifying the Product: No Hype, Just Performance

    On our line, we don’t chase the latest “green” manufacturing jargon, but we do treat water and raw material usage responsibly to avoid environmental headaches. CAPS-Na synthesis relies on straightforward but sensitive chemistry. Small variations in reaction temperature or pressure often show up in final batch analytics. Our plant staff tracks these steps by both instrumentation and manual titration, never letting automation alone dictate adjustments. We find this blend of modern process controls and experienced human intervention yields the most reliable product, lot after lot.

    We know our acid neutralization steps are textbook chemistry, but by double checking sodium counter-ion incorporation and verifying crystalline structure under the scope, we've solved issues that tripped other producers in the past. Especially in larger lots, we check not only for absence of impurities, but also for yield efficiency, since unconverted starting material shows up in analytical gels and can confound users searching for the cause of “mystery” results in transferred proteins. Our on-site team’s hands-on vigilance removes these headaches before the product leaves the plant.

    Feedback Loops—From Field to Production

    Direct customer engagement is rare in chemical manufacturing, but over time, we have built a network of researchers who report back real-world successes or setbacks. One proteomics team at a major academic center alerted us to a slight outlier on UV transparency in a lot from an outside supplier—an issue wiped out by slight tweaks in our own crystallization regime. Another pharmaceutical firm described failed lot-to-lot reproducibility in commercial buffer solutions, only to restore their workflow after switching to our finely sieved, low-moisture CAPS-Na.

    Our approach is to honor those stories that detail a protocol fixed, a headache avoided, or a run completed on time. Each improvement teams up with our batch log database and operator experience to make sure the next run leverages today’s learning. This knowledge cycle means the sodium salt coming off our production line next week reflects the wisdom of hundreds of scientific collaborations, not just internal process specs.

    What We’ve Learned After Years on the Line

    No chemical buffer is “just a commodity”—at least, not for the men and women actually doing research or diagnostic kit assembly. Popular buffer alternatives may lure on price or apparent availability, but we’ve fielded too many emergency calls stemming from off-brand product that simply did not perform as expected. Maybe it showed up with undissolved particles, a pH drift, or bulk color that warned of oxidation. Often, the affected lab lost not just money but critical experiment time. We treat each lot as the anchor for someone else’s workflow.

    Some customers asked if we’d switch to cheaper raw inputs or shortcut final oil removal but our lean production set-up rejects these short-term gains. After all, one overlooked impurity becomes a chronic management issue for clients far downstream. Even academic labs, living on grant budgets, tell us how they weigh every small decision on product selection. A lot shipped Thursday is very likely being titrated and loaded in some major university by Monday—the human link is not lost on our staff.

    On Information Transparency and Market Claims

    As direct manufacturers, we face a chemical market crowded with repackagers who can’t actually vouch for the raw source, synthesis steps, or exact batch composition. This matters—customers with traceability expectations want more than a product summary—they ask for analytical sheets, process descriptions, and supplier attestation. We prepare full certificates at batch level and keep historical analytical archives. Researchers, quite rightly, do not tolerate mysteries behind the materials in their experimental workflow.

    CAPS-Na stands out for many clients because we can show independent lot-by-lot lab data, not just a general statement on purity. This builds trust far beyond a basic “buffer grade” guarantee. As teams across research, pharma, and diagnostic sectors chase ever-tighter reproducibility, materials they use must respond to those demands. Our production records, open for audit or review, give customers the confidence they lack with nameless imports or gray-market sources.

    Solving Real Chemical Challenges

    Issues with CAPS-Na have rarely been about synthesis difficulty—it’s not a hard process on paper. Where manufacturers trip is at the execution level. Over time, we optimized the cyclohexylamino ring formation, hydroxylation, and sulfonation so that we avoid common side-products encountered in batch synthesis. Customers—especially those filtering for sensitive DNA or protein work—demand exceedingly low metal ion and organic contaminant levels.

    After some high-profile feedback about strange precipitates and low background interference in enzyme-linked assays, we extended our analytical ranges to include mass spectrometry and advanced UV detection for typical environmental contaminants and foreign ions. The result is a more predictable, transparent offering each time a researcher opens a new container.

    Comparing to Competing Buffers—Production and Application Insights

    Some manufacturers view all Good’s buffers as functionally equivalent, boasting overlapping pH ranges or similar solubility. Years in the field showed us how misplaced that attitude is. The sodium salt of CAPS offers unique resistance to oxidative and photolytic breakdown in standard lighting and under varied storage conditions. Our batches hold their pH stability far better than, say, glycine or Tris-based systems when challenged by repeated cycling, freeze-thaw, or vigorous mixing.

    CAPS-Na also avoids ammonia release during storage, which plagues some amine-based buffers, and its bulk powder resists caking and absorption cues far longer than other buffer options. Users report that clear solution preparation occurs in a shorter time and with fewer filtration steps, cutting start-up labor compared with other buffers in the same pH window. These operational perks form stories our customers and internal QA teams repeat long after a lot leaves our plant.

    Every Batch Tells a Story

    We continue to field requests from diagnostic developers, protein chemists, and large-scale kit manufacturers whose own success depends on a handful of foundational reagents—among them, CAPS-Na in its sodium salt form. Each batch becomes a small chapter in progressing human health, biological understanding, or next-generation technology. Our manufacturing legacy isn’t written by glossy marketing or empty claims, but through consistent delivery, daily laboratory interaction, and never straying far from the people using these chemicals for world-changing work.

    Looking Forward: What It Means for End Users and Makers Alike

    Our plant has seen a spectrum of buffer salts, from standard-issue to highly engineered. What we’ve come to respect most is the ongoing partnership—sometimes unspoken—between the manufacturer and the scientist. Product quality, reliability in shifting conditions, and adaptability to packaging needs all feed the circular process of discovery and refinement. By investing in the steady delivery of high-purity CAPS-Na, we help shape protocols learned by students, repeated by postdocs, and then scaled in industrial labs around the world.

    Scientists trust what they can verify, not just what they’re told. Every bottle and bag that leaves our building passes through the judgment of technicians who view their role not as just another shift, but as a crucial step in the chain of research progress. Through detailed observation, adaptability, and a firm commitment to batch quality—not just paperwork purity—we offer more than a buffer; we anchor the confidence of those who use it. That’s the real difference that comes from being close to both the chemistry and the work it supports.