HS Code |
130121 |
| Chemical Name | 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic Acid |
| Abbreviation | CAPSO |
| Cas Number | 73463-39-5 |
| Molecular Formula | C9H19NO4S |
| Molecular Weight | 237.32 g/mol |
| Appearance | White crystalline powder |
| Solubility | Highly soluble in water |
| Pka | 9.60 at 25°C |
| Buffer Range | 8.9 - 10.3 |
| Melting Point | 300°C (decomposes) |
| Storage Condition | Store at room temperature, dry place |
| Synonyms | N-Cyclohexyl-2-hydroxy-3-aminopropanesulfonic acid |
As an accredited 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic Acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 100g Sigma-Aldrich bottle features a white, chemical-resistant plastic container with a secure blue screw cap and printed hazard labeling. |
| Shipping | 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic acid ships securely in sealed, chemical-resistant containers compliant with safety regulations. The package includes a Certificate of Analysis and Safety Data Sheet. Transported under ambient conditions unless otherwise specified, the product is protected from moisture and contamination to ensure high purity upon delivery from Sigma Aldrich, Merck, or TCI. |
| Storage | **3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic Acid** should be stored in a tightly sealed container, away from moisture and direct sunlight. Store at room temperature (15–25°C), in a cool, dry, and well-ventilated area. Avoid exposure to strong acids, bases, and oxidizing agents. Follow standard laboratory safety protocols, as provided by Sigma Aldrich, Merck, or TCI Chemical grade suppliers. |
Competitive 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic Acid prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The chemical world can feel remote and abstract, but in our facility, the story behind each batch is clear. Our 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic acid, commonly known as CHAPS, starts with high-purity starting materials and careful batch design. CHAPS shows up in the lab as a white, crystalline powder. Batch purity checks, handled in-house, focus on removing residual salts and cyclohexylamine to prevent interference during sensitive protein work. We use glass-lined reactors and dedicated fill lines to keep cross-contamination in check, especially important since our batches split for both research and production customers. Since every production line is different, we keep tight logs on trace ion content and water percentage—both can throw off downstream results.
Decades back, we faced the same problem as our customers: small fluctuations in buffer reagents could ruin days or weeks of research. Even a fraction of a percentage off in sulfonic acid group placement or a little extra cyclohexylamine can cause headaches in chromatography or protein isolation. Over hundreds of batches, we learned points of failure. Moisture control is a major concern—CHAPS likes to pull water from the air, changing measured concentration without warning. Our bins seal under nitrogen, and all lots go over Karl Fischer titration before leaving the plant. Testing at both the start and finish of packing keeps the margin for error slim. Our goal has always been to help research teams skip the buffer troubleshooting and focus on results.
Ask any biochemist about surfactants, and you’ll get war stories about denatured proteins and fouled columns. Traditional agents like SDS or Triton X-100 often disrupt proteins or interfere with downstream analytics. CHAPS earned a place in the bench toolkit by balancing mildness and strength. Solubilization demands power, but not at the cost of protein structure. CHAPS’s zwitterionic nature means it holds both positive and negative charges at physiological pH. This property keeps proteins in solution while protecting native folds. In the plant, we take that lesson seriously. We design our final pH range carefully during drying and powder handling—too acidic or basic and CHAPS starts to lose its unique behavior.
Some early users tried substituting with the more established Good’s buffers. While familiar, those lack the amphiphilic character crucial for membrane protein research. CHAPS’s power lies in helping membrane fragments and proteins stay in solution without the foaming and denaturation seen with ionic surfactants. Every batch carries an HPLC fingerprint from our QC team to verify it meets these important properties. Customers tell us they see less background in electrophoresis runs and fewer failed membrane isolation attempts compared to old-school choices.
Down on the floor, theory meets practice. We use large drum dryers to bring water content under 0.5%, a crucial spec for stability. Even tiny increases let cakes form in storage, which gums up dissolution the next time someone in a university lab needs a fresh buffer. We blend each lot gently to minimize fines and dusting, knowing fine particle disperses unevenly in water and leads to batch-to-batch variation in downstream work.
Our engineers tinker with process flow regularly. Thermal profiles during crystallization get special attention, since crystal habit changes affect filterability and ease of handling. Whenever possible, we keep the process hands-on, with experienced techs checking the product at each stage. In science, consistency is king. Our founder set a rule: if a batch can’t help a customer sequence a protein, it doesn’t leave.
Specs often read like a checklist, but behind each number is a manufacturing step or solution to a problem we’ve solved.
Protein science barely resembles its state thirty years ago. Early applications used crude batches for basic solubilization tasks, but new protein therapeutics and high-throughput screening raised the bar. Labs keep tightening purity standards to avoid artifacts in NMR, mass spec, and functional screens. As research pushes into more complex structures—membrane receptors, signaling assemblies—the old tricks don’t cut it.
In feedback from academic and pharma clients, we hear the same thing: batch differences turn simple purification work into guesswork. Over time, easy dissolving, precise pH control, and a clean background make the difference between publishing or troubleshooting. A reagent that just “works” fades into the background, freeing smart people to focus on their science. We aim to keep our CHAPS line in that zone.
Competing options usually fall into either ionic controls like SDS, nonionic choices such as Triton derivatives, or zwitterions with a different backbone. Each has a place, but no one wants to compromise solubilization yield for downstream trouble.
Ionic detergents like SDS strip protein structures apart. They work for total denaturation, but nothing survives. Good for PAGE, but rarely mild enough for function studies or crystallography. Triton or NP-40 raise background and trigger aggregation in sensitive assemblies. Even other zwitterionics can miss the mark—sometimes they need more than moderate ionic strength or lose their gentle touch under mechanical stress.
Our experience with membrane proteins, especially those with fragile transmembrane domains, shows that CHAPS walks a narrow line. It breaks up protein-lipid assemblies but leaves the protein’s function intact for downstream analysis. No foaming, slower protein turnover, and fewer unknown peaks in LC-MS or MALDI. Our R&D staff run small-batch tests that get shared with visiting scientists, comparing our lot with others on simulated downstream workflows to track these exact results.
Too often, manufacturers cut handling steps to save on time and labor, hoping fine-tuning can wait for the next big order. Experience says otherwise. Product that sits in steel hoppers too long picks up ions, even in a controlled warehouse. Cyclohexylamine smell tells a story: the amine hydrolyzed too far or was not driven off during drying. The techs in our plant catch these issues before batch release, not after.
The learning curve is steep. Young engineers see a batch that meets spec and think it’s enough. But we’ve seen entire research projects derailed by invisible process shortcuts, such as incomplete filtration or skipping a drying cycle to meet a shipping date. It doesn’t matter how clean the process starts if the end isn’t perfect. Accountability stays on those who handle the process start to finish, and customers often recognize that difference in the final result.
Demand for CHAPS isn’t limited to academic work. Clinical research and biotech development set another level of challenge. Diagnostic assay kits depend on batch reproducibility as much as purity. Proteomics workflows in pharmaceutical companies rely on the same parameters, but apply the product under much stricter controls. Diagnostic manufacturers purchase high-volume CHAPS for use in sample buffers, many moving toward GMP-grade needs. We adjust cleaning and traceability protocols as regulations require, but never touch the core recipe.
Therapeutic protein work looks at things differently. Trace by-products impact regulatory approval. We have faced increasing calls for extended impurity profiling—mass spec scans, not just HPLC checks—to meet evolving guidelines. Labs request full chain-of-custody for each drum and lot-to-lot consistency for clinical studies. Our system tracks every drum back to the first blend, with redundant record-keeping at both production and packing.
Over the last decade, the lens has widened beyond just technical quality. Researchers want to know the energy footprint and waste profile of their supplies. Every process at our site, from solvent recovery to spent filter cake disposal, faces annual review. We switched to closed-loop water chilling and solvent recovery years before regulations required it, both for cost and because the community expects it. Suppliers pitch new green chemistry options, but we advance only those that don’t compromise product specs.
Some by-products once landfilled now route to incineration with reclamation of energy. New water scrubbers cut on-site emissions and protect our staff from aerosol exposure during handling. These aren’t just cost-saving sideshows: engineers and chemists have to own by-products as well as yield. Waste audits now form part of each new product review.
Our goal, shaped both by customer expectations and regulatory eyes, is to keep CHAPS production well above minimum standard—and to tread lightly as demand grows.
Keeping product quality at the leading edge means opening communication lines to the users. We don’t treat feedback forms as box-ticking. Each lost lot, customer complaint, or new suggestion gets a root cause review. Several key improvements—such as double-packing for extra moisture protection and shift to all-glass reactor lines for critical lots—came from customer input, not lab theory.
Our test labs are always running tweak trials: new milling approaches for finer powder, switching between crystallization solvents, or new analytical methods for tracking side-reactions in real time. By sharing findings with users willing to take part, we see better results together. A buffer isn’t a commodity; its impact shows up only under tough experimental conditions.
We run comparison studies in our pilot line, putting our CHAPS lots alongside others in the market, then running standardized protein preps, membrane fractionations, or NMR sample setups. Users who rely on tight pH and low baseline interference can quickly spot the small details that set one batch apart from another.
Handling fine chemical reagents requires more than just scooping and weighing. We encourage users not to trust general stockroom rules for specialty surfactants. For CHAPS, direct water addition, mixing in a vortex or overhead stirrer, and temperature control deliver best results. Some research staff make the mistake of rehydrating directly from the foil, picking up outside humidity and changing the effective dose. We suggest weighing in a dry room, using desiccated glassware, and transferring rapidly into solution. Unused product returns to a sealed container under inert gas or desiccant.
Users working at higher concentrations for membrane solubilization should look for telltale signs of degradation—color shifts, odorous notes, or lower-than-expected yield after buffer setup. A good product line offers batch records to trace each lot, packaging codes to match back to a certificate, and ready access to specification sheets for quality checks.
No two research environments run exactly the same, so buffer needs vary. Still, a quality surfactant like CHAPS bridges traditional chemistry with modern protein science—a tool that supports messy, ambitious research instead of holding it back.
No shortcut replaces careful documentation, ongoing process review, and a healthy respect for customer needs. Our manufacturing team grew up on the shop floor and in the lab, and we know the “little things” in production leave fingerprints far down the pipeline. We listen closely to those working on the research front, getting details on what worked, what failed, and where the next challenge lies. Each improvement—better particle sizing, tighter impurity control, more deeply screened heavy metal content—came from hard-earned experience, not guesswork.
At its heart, 3-(Cyclohexylamino)-2-hydroxypropane-1-sulfonic acid isn’t just another buffer. For a research project with real stakes, every detail counts. We back each drum, each batch, with a full set of records and a commitment to push the standards a little higher each year. Customers looking for more than “good enough”—those are the partners we build for.