|
HS Code |
853493 |
| Product Name | 2-Iodoacetamide [for Biochemical Research] |
| Cas Number | 144-48-9 |
| Molecular Formula | C2H4INO |
| Molecular Weight | 184.97 g/mol |
| Appearance | White to off-white crystalline powder |
| Purity | Typically >98% |
| Solubility | Soluble in water, methanol, ethanol |
| Storage Temperature | 2-8°C |
| Melting Point | 149-153°C |
| Sensitivity | Light and moisture sensitive |
| Synonyms | IAA; Iodoacetamide |
| Application | Alkylating agent for sulfhydryl groups in proteins |
As an accredited 2-Iodoacetamide [for Biochemical Research] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | White, opaque plastic bottle with red cap, Sigma-Aldrich label; contains 5 grams of 2-Iodoacetamide for biochemical research use. |
| Shipping | 2-Iodoacetamide [for Biochemical Research] is shipped in tightly sealed containers to prevent moisture and light exposure. It is typically dispatched at ambient temperature, unless otherwise specified, and accompanied by appropriate safety documentation. Ensure prompt receipt and storage under recommended conditions to maintain chemical integrity and researcher safety. |
| Storage | 2-Iodoacetamide [for Biochemical Research] should be stored tightly closed in a cool, dry, and well-ventilated area, away from light and incompatible materials such as strong oxidizers. Recommended storage temperature is 2–8°C (refrigerated). Ensure the container is properly labeled and protected from moisture. Refer to the supplier’s safety data sheet (SDS) for specific guidance from Sigma Aldrich, Merck, or TCI Chemical. |
Competitive 2-Iodoacetamide [for Biochemical Research] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As the producer behind 2-iodoacetamide, I’ve spent years watching researchers push the boundaries of their fields. So much hinges on reliable reagents. Our 2-iodoacetamide stands out among biochemical tools, crafted from the ground up in our facility with careful attention at every processing step. The compound, known for its high reactivity and stability, supports serious bench science that cannot afford shortcuts or contamination. From fundamental protein chemistry to proteomic workflows, the call for consistency and purity often overshadows catalog shopping for the cheapest grades.
Our team formulates 2-iodoacetamide using carefully managed, low-oxygen and dry environments to hold off hydrolysis. With a molecular formula of C2H4INO and a purity exceeding 99%, each batch reflects rigorous sample testing. White to off-white crystals, stored and packaged to keep atmospheric moisture at bay, arrive ready for research protocols that demand interference-free performance. The unique iodoacetamide backbone allows alkylation of cysteine residues — a key property exploited by life science labs everywhere for protein structure analysis.
As a manufacturer, we get phone calls and detailed emails from labs who tried swapping to cheaper or less pure sources. Sometimes, the tiniest impurity derails mass spectrometry runs. Proteomics depends on predictable, complete alkylation; 2-iodoacetamide’s heavy iodine atom gives it both selectivity and reliability unmatched by smaller haloalkyl amides. Dithiothreitol or tris(2-carboxyethyl) phosphine treatment leaves cysteine thiol groups reactive; 2-iodoacetamide acylates them, locking the protein in a chemically defined state.
QC teams in our lab carry out HPLC, NMR, and mass spec on every lot, exposing even trace byproducts. Sometimes, even a minute batch variation will trigger an internal review. Over the years, we’ve tightened protocols to ensure that researchers can focus on discovery rather than reagent troubleshooting. The stakes go beyond yield or price, especially in experiments where protein mischaracterization can lead to misinterpretation of the target structure.
Some colleagues in biotech approached us about customizing the particle size for high-throughput applications. Yet, after careful testing, their teams returned to our standard crystalline grade; they discovered that off-spec particle distribution hurt solubility, leading to inconsistent cysteine blocking in sensitive proteomics workflows. We heard firsthand about ruined runs and the time lost to trouble-shooting batches from uncertain supply chains.
Our synthesis team often gets asked about the differences between 2-iodoacetamide and its cousins, like iodoacetic acid or N-ethylmaleimide. Every compound comes with its own quirks. For instance, iodoacetic acid can target histidines or lysines under the wrong pH, muddying results. N-ethylmaleimide frequently reacts faster but can introduce instability and cross-reactivity with protein backbones or environmental nucleophiles. Through controlled trials, our users mentioned that only 2-iodoacetamide shut down extra reactivity in complex mixtures, leading to cleaner mass spectra or chromogenic analyses in downstream steps.
The iodine’s bulk stabilizes the molecule post-alkylation, which means proteins remain unmodified apart from the cysteine block. This feature distinguishes 2-iodoacetamide in workflows aiming for quantitation or structural analysis, especially where proteins with multiple cysteine residues risk partial or side-chain alkylation from other reagents. In our own process QC, batches undergo peptide-mapping to verify single-point modification, prioritizing traceability from raw feedstock all the way to the finished bottle.
Academic researchers remind us that stability often sets 2-iodoacetamide apart. Many labs lack strictly controlled humidity or refrigeration space for reagents. We reinforce vials to resist moisture intrusion and batch-test packaging under shifting temperature cycles that might occur during cross-border shipping seasons. Practical use means the bottles sometimes leave cold storage for extended periods during sample prep. We aim to keep each gram fresh and effective, from our plant to the last use in your coldroom.
The team watches for possible sources of contamination, especially heavy metal residues or plasticizer carryover. Every production run uses entirely glass-lined reactors and high-purity solvents. I still remember a shipment back in early days where minor trace metal content from a tank introduced unwanted background in proteomic standards — that led us to overhaul sourcing and invest in better equipment, focusing on reproducible, trace-free chemistry. Consistency is the backbone of our brand, not just because regulatory filings demand it, but because dozens of our oldest customers let us know that reproducibility settles the argument when choosing where to buy for the next grant season.
Over the years, we learned that cost-cutting shortcuts in production only create headaches down the line. Our crystallization step takes several days, monitored around the clock. We let mother liquors settle out and discard anything visually off-spec or carrying any hint of insoluble residue. Unlike bulk traders, we have no incentive to dilute, extend, or blend old lots. If even a faint yellow discoloration emerges, the batch gets analyzed and, if necessary, remelted or scrapped completely.
On a busy day, a single kilogram can be traced back to a specific reactor, batch time, and technician. A robust electronic tracking system links source materials to shipment records. Our warehouse checks every package’s seals for integrity before sending out orders, and we notify clients if there’s been a delay or a QC anomaly. We never ship unless the quality team signs off. Those policies emerged after a difficult week of complaints from distant buyers who’d tried less careful vendors; once they experienced defects in assay protocols, more than half converted to our supply chain for good.
Proteomics researchers are not the only ones needing uncompromising alkylation. We field requests from molecular biologists preparing enzyme inhibition studies, cell biologists performing thiol-blocking in signaling pathway analyses, and pharmaceutical developers working up reference standards for biologics. Each protocol can have subtle differences, yet all demand low UV absorbance, low heavy metal content, and crystalline stability at room temperature.
SDS-PAGE users report reduced protein streaking with our 2-iodoacetamide compared to older, lower-purity counterparts. When prepping for mass spectrometry, we’ve seen labs repeatedly order our material after direct comparisons with other suppliers left them with incomplete cysteine modification or background peaks from excess side-products. The analytical world runs on clean signals; bad alkylation can throw an entire dataset off balance, rendering months of preparation useless.
Beyond textbook science, practical usage often means working late, short on time and staff. Inconsistent or low-purity material introduces headaches in the form of troubleshooting, data re-analysis, and wasted grant cycles. We design packaging to open easily and pour smoothly, preventing crystalline powder loss. Vials remain transparent to check for any signs of hydration or clumping, letting labs avoid opening degraded material by accident.
Production regulations have tightened internationally, and we comply with all local and overseas requirements. Each outgoing lot ships with a certificate built from real batch data. Labs working in GxP or GLP environments know this level of transparency streamlines regulatory paperwork and third-party audits. Some of our largest clients periodically visit for in-person audits, walking through production and reviewing every bottle’s traceability. These conversations keep pressure on us to update protocols, retire outdated equipment, and invest in laboratory automation.
Feedback loops from customers drive many improvements. After hearing about issues with static and spill risk under dry winter conditions, we introduced antistatic liners and better screw caps. When a customer’s proteomics group requested larger bottles to support automation robots, our team custom-designed bulk packaging. I recall visiting a university core facility and seeing our labels in nearly every refrigerator. Reproducibility means more to us than sheer volume or speed; it is about taking pride in seeing conclusions and publications built on rock-solid technique.
It would be easy to believe all 2-iodoacetamide is interchangeable. Yet, discussions with specialists highlighted that small variations — in residual water, particle size, or even packaging conditions — impact yield and consistency. Some imported goods arrive with caked powder, already clutching atmospheric moisture that undermines accuracy. Skimping on purity leads to unpredictability and wastes time experimenting with workarounds.
Synthetic steps matter. We keep byproduct levels low, run all intermediates through recrystallization, and regularly analyze waste streams for anomalous side reactions. The result is a clean product that behaves as expected. This is not about chasing the lowest cost, but about investing in protocols that support years of reproducible results across an international research community.
Some researchers have tried using alternative alkylating reagents, and sometimes, due to unfamiliarity or lack of careful documentation, their workflows suffered. Cysteine blocking failed or generated multi-adduct situations, and they needed to redesign experiments. Those stories return to us as lessons. They reinforce our belief that meticulous chemistry and comprehensive testing throughout production—not just paperwork at the end—deliver real value for scientists.
The applications only expand with new technologies. Proteomics, single-cell analysis, and structural biology rely on reagents like 2-iodoacetamide to anchor key steps. As protein folding and conformational studies push the envelope, any shortcut in cysteine blocking can introduce structural ambiguity with wide-reaching impacts. We know many journal editors review methods sections carefully—trace contaminants or batch variation in key reagents jeopardize publication and reputational capital.
Large-scale industrial protein modification projects use our 2-iodoacetamide to anchor batch processes. The pharmaceutical industry, too, expects the highest batch-to-batch reproducibility for regulatory filing and product release. For these users, the paper trail from raw material procurement, through synthesis, to final bottling is not optional. We archive all production data for several years, so any question about a specific lot number finds a quick answer. Liability concerns in regulated industries leave no room for ambiguity.
After listening to industrial clients and university partners, we started offering smaller lots for bench biologists and larger bulk packages for automated peptide-mapping core facilities. Regardless of volume, each pack undergoes the same quality regimen. We frequently ship small samples, letting users crosscheck against their own benchmarks. This policy grew out of dozens of requests for side-by-side experiments. We have nothing to hide and see the benefit in enabling transparent comparisons.
Some buyers look for green chemistry credentials even in specialty chemicals. We continue to examine production steps for waste minimization, lower-energy crystallization, and reduced solvent use. This approach stemmed from in-house initiatives, before customers ever asked for it. As a result, our process produces less chemical waste than typical sector averages, and all solvents are fully recovered for reuse or neutralized according to official procedures. Community and environmental health matter alongside scientific progress.
Each bottle of 2-iodoacetamide that leaves our facility connects us directly with researchers, developers, and students who rely on chemical consistency to make sense of their data. We’ve weathered ingredient shortages, evolving protocols, and stricter audits by sticking to robust chemistry and open, honest communication with clients. The lessons learned on our production floor echo back in your successes—clear bands on gels, sharp protein mass spectra, and discovery of real biochemical phenomena.
Using 2-iodoacetamide as a routine protein alkylating agent means betting scientific progress not on cost, but on confidence. In a world full of shortcuts, our team believes honest, reproducible chemistry remains the surest route to discovery. We’re proud to count many of science’s most careful hands among our partners and commit to making their work a little steadier with every meticulously prepared batch.