HS Code |
265969 |
| Chemical Name | 2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-Dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate |
| Molecular Formula | C29H29N7O8 |
| Cas Number | 2202074-32-7 |
| Appearance | Dark red to brown powder |
| Solubility | Soluble in DMSO, DMF |
| Storage Temperature | -20°C (desiccated) |
| Purity | ≥95% (HPLC) |
| Functional Group | NHS ester |
| Application | Amine-reactive dye for labeling biomolecules |
| Absorption Maximum | Approximately 520 nm |
| Hazard Statements | May cause irritation to skin, eyes, or respiratory tract |
| Synonyms | NHS ester of Disperse Red 1 derivative |
| Smiles | COC1=CC(=C(C=C1N=NC2=CC=C(C=C2)N(C)CCCC(=O)ON3C(=O)CCC3=O)N=NC4=CC=C(C=C4)[N+](=O)[O-])OC |
As an accredited 2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-Dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma Aldrich sells 100 mg of **2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate** in an amber glass vial with a printed label. |
| Shipping | This chemical is shipped in compliance with regulatory standards for hazardous materials. Packaging ensures protection from moisture, light, and contaminants. It is transported in sealed containers with appropriate labeling, handling, and safety documentation. Shipping may require temperature control, with transit times minimized to maintain product integrity. Consult carrier and SDS for detailed handling instructions. |
| Storage | **Storage Description:** Store 2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate in a tightly sealed container, protected from light, moisture, and heat. Keep at 2–8°C (refrigerated) in a dry, well-ventilated area. Avoid exposure to strong acids, bases, and oxidizers. Handle under appropriate laboratory safety protocols. |
Competitive 2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-Dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Manufacturing specialty reagents isn't just a technical vocation. Experience in our industry builds over decades—feeling the rhythm of how small molecular changes play out across whole production runs, how each synthetic step demands accuracy, and how the finished compound matters for researchers at the bench and in pilot labs across the world. Ask anyone who’s ever handled diazo compounds or sensitive activated esters—minor impurities or unstable isomers frustrate whole research programs, and wasted cycles can put real-world projects months behind.
With 2,5-Dioxopyrrolidin-1-yl 4-[[4-[[2,5-Dimethoxy-4-[(4-nitrophenyl)diazenyl]phenyl]diazenyl]phenyl](methyl)amino]butanoate, the motivation for synthesis always echoes directly from conversations with scientists. It’s always about reproducibility in bioconjugation, reliability in chromogenic applications, and ease of purification downstream. As manufacturers, we do not ship vials: we deliver batch-to-batch trust backed by traceable process control and analytical data reflecting hard-won in-process checkpoints.
This molecule, recognizable by its lengthy structure and the pop of that nitrophenyl-diazenyl chromophore, has become a staple where visible color, azo linkage stability, and robust NHS activation combine. Usually, teams constructing labeled peptides, antibodies, or polymer carriers know the pain of hydrolysis-prone NHS esters falling apart during handling or storage. Here, we’ve optimized our process conditions—right down to solvent polarity, humidity at workup, and exacting lot segregation—to keep that NHS group clean and reactive, shelf-stable under dark and dry conditions, and ready for high-yield aminolysis on demand. Every time we pack a jar, we see those telltale deep orange-crimson crystals and know the team upstream nailed both conversion and purification. Analytical chromatograms from UV-vis, HPLC, and NMR confirm target purity above 99%, emphasizing that stabilization and handling outpace the legacy benchmarks in the space.
Colleagues in academia and diagnostic kit manufacturing often share stories about problems with lot-to-lot variability and pigment contaminants disrupting quantification readings—turns out, control of the diazo coupling and precise elimination of ortho- and para-isomers affect reproducibility far more than many realize. We built custom QC methods to separate out any by-product at sub-percent levels because a few stray chromophores dramatically skew optical readings and biotinylation yields downstream. Our specs consistently report on mass balance, water content (Karl Fischer below 0.3%), and residual solvents (GC-MS below 10 ppm for regulated compounds). Beyond numbers, it’s the open phone conversations and roundtable feedback that keep the bar high: our QC team refines methods in response to problems clients faced with older products, such as clumping, loss of dye strength, or unintended reactivity with common buffers.
End users count on stability—to the extent we monitor each batch’s storage profile and recommend storage protocols based on extensive forced degradation studies. The powder stays free-flowing. The absorption maxima never shifts, thanks to confirmed batch homogeneity and photostability studies run every quarter. We reject any container where solvent trace, IR spectrum, or color shade deviates from historical data keyed to actual conjugation performance. Those finer points, invisible to a trader or paper reseller, come from practical, hands-on responsibility: no one wants to be the vendor who ships a dud batch to a diagnostic kit launch or a major university research effort. That pride and weight drive our entire operation from raw material selection, reaction temperature control, purification with ultra-high pressure chromatography, and post-processing protections—every time.
Chemists often group NHS esters into one bucket, forgetting how the backbone attached to that NHS imparts unique characteristics, especially when downstream chemistry gets complicated. Too many catalogue suppliers shy from discussing the finer points—solubility in mixed aqueous-organic buffers, spectral overlap with common dyes, or specific protein labeling compatibility. Fielding questions daily from customers at the sharp end of biomedical and molecular diagnostics, we learned which synthetic tweaks make life easier and which lingering by-products make headaches multiply.
The defining feature of this molecule sits in its robust 2,5-dimethoxy modification and extended azo linkage, which results in long-wavelength absorption and colorimetric sensitivity. Unlike more generic NHS-activated compounds, this one delivers reliable labeling even under mild conditions, with less hydrolytic breakdown—a hassle for users handling sensitive targets in non-ideal setups. The methylamino-substituted butanoate bridge not only increases aqueous dispersibility but also reduces nonspecific adsorption, which in peptide coupling translates to superior signal-to-noise ratios and cleaner product isolation. Researchers no longer need to run excess quenching or separation steps just to get clean conjugates.
We make a point to reflect feedback in every step—not just the paperwork but actual modifications in the process. For instance, past users of similar dyes reported sluggish reactions due to oxidative decomposition; our air- and moisture-controlled isolation prevents these side-products from emerging, producing powder that stays reactive longer and resists yellowing. Because the compound’s spectral properties overlap with some enzyme-substrate assays, we work directly with diagnostics teams to fine-tune the dye structure so unwanted cross-reactivity doesn’t sabotage kit readouts.
From the moment we scaled up lab synthesis to pilot reactors, we worked closely with protein labeling teams to understand where older generations of colorimetric NHS esters tripped them up. Core applications include targeted bioconjugation—think monoclonal antibody pegylation, amine-reactive dye prep for oligo labeling, or even more consumer-facing diagnostics like assay test lines in lateral flow devices. The value comes from not needing to overlabel delicate biomolecules, thanks to the strong, persistent signal and steady color response. Researchers see sharper bands, quantitate more reliably, and don’t waste time re-purifying labeled material.
The visible spectrum absorption, centered around the extended azo system, opens up multiplexing possibilities for those running multiplex immunoassays—no doubt, a byproduct of how the framework disperses energy and resists photobleaching over multiple cycles. By maintaining low background fluorescence and high extinction coefficients, teams realize more sensitive detection in medical and analytical fields. And because the molecular backbone enables anchoring to a wide variety of surfaces—glass slides, nitrocellulose membranes, magnetic beads, polystyrene particles—its adoption spans far beyond a single niche. Peptide synthesis labs, custom reagent producers, and academic chemical biology groups all adopted stricter labeling and storage regimens after seeing the overnight stability afforded by the formulation we ship. The pain of sample degradation and unscheduled reruns has dropped sharply for our partners, and we track those statistics as closely as yield or throughput numbers.
Chemical manufacturing faces real pressure—not just about throughput, but in how sustainably and cleanly we generate specialty compounds. Long production chains traditionally meant higher risks of solvent waste or problematic by-products. We documented and overhauled solvent use, with in-house distillation and novel extraction steps that significantly cut waste and environmental footprint. Wastewater from our plant now meets stricter compliance targets, and our recovery process for the core diazo intermediates means losses fell well below industry averages. We replaced older, legacy filter agents once found in predecessor products, eliminating one source of user complaints about haze and insolubles in long-term storage.
Every batch proceeds under tight glass-to-glass protocols. No untreated process intermediates leave the plant. Off-spec product goes straight to recovery, reducing landfill and hazardous disposal. Our commitment here isn’t just regulatory; staff take pride in peer review and complete tracebacks on raw material origins, so researchers receiving our compound trust both product identity and the pathway it took—a difference big enough that some labs switched from global distribution to direct-from-manufacturer sourcing after seeing what QA actually means day-to-day in our facility.
Storage and usage guidelines often get overlooked as boilerplate, but experience with this compound underscores their importance. The NHS ester only delivers its true power in clean, dry conditions with minimal light—to support this, we developed triple-sealed packaging and ship everything under inert atmosphere using desiccant pouches. Persistent feedback from users who store kits in field conditions or fridge/ambient rotations led us to validation protocols reflecting real-world mishaps. Technicians reported successful recoveries from 1-2 hour ambient exposures—useful for field-forward operations or decentralized testing workflows where perfect conditions can’t always be maintained.
Dosing precision matters, especially in small-scale coupling where every milligram counts. We recommend weighing under argon, avoiding unnecessary exposure before use. The low water content and free-flowing powder mean no stubborn clumps or “caking” from hydroscopic action—an upgrade over earlier market versions that often needed manual breakup and additional drying. Users working with automation or microvolume pipetting highlight improved reproducibility with our lots. For cleanroom and GMP work, our line speed and batch segmentation guarantee traceable, documented production free from reagent hangover or cross-contamination concerns—a result of prevention strategies based on direct stakeholder reviews rather than after-the-fact responses.
Resolving persistent issues in activated ester synthesis forced us to iterate an almost obsessive approach to continuous improvement. Every failed coupling, every analytical outlier, and every customer tip-off serves as a catalyst for new process trials. Engineers know—one overlooked side-product at 0.5% can upend a diagnostic kit validation, just as one bad batch can strain years of hard-won partnership. Everyone in our production cycle, from senior chemists to warehouse staff, invests in this improvement—bi-weekly cross-team meetings document surface-level slip-ups and deep-dive into reaction bottlenecks or storage anomalies. As a result, our process evolved to deliver higher throughput, less downtime, and above all, a lower incidence of downstream headaches for those who use our compounds.
Constant data review—both historic and live—keeps us razor-sharp about what our customers see. If an odd peak shows up in end-user HPLC, or if someone notices color fade inside a kit envelope, feedback pours straight into our process analytics platform. Fast response teams adapt the next lot, change the purification column, or adjust crystallization. Veteran staff remember the days batches shipped out blind, leaving customers to discover flaws. Today, our commitment runs deeper, built from tough lessons and honest feedback loops. Reliability means more than just a “pass” on purity sheets: it’s real-world validation, from the bioprocess floor to the university lab, underscored by direct, lived experience producing for specialists who demand—and depend on—the highest standard.
Pioneering products is one thing; supporting the chemists who use them takes frontline commitment. The journey of this NHS ester traces back not in spreadsheets or catalog numbers, but in the living experience of production teams and researchers working at the intersection of synthetic chemistry and applied diagnostics. Our role remains clear—listen closely, iterate bravely, and ship with accountability built into every batch. For us, manufacturing means a handshake built of trust, knowledge, and the certainty that every gram you receive has passed through the hands, hearts, and hard-won experience of a team dedicated to your success in the field.
For further technical advice, troubleshooting, or real-world input, our team always answers directly—no layers, no deflection. Whether launching a new assay, running batch optimization, or scaling R&D into manufacture, collaborative input improves outcomes at every stage. From one manufacturer to another scientist, confidence in your raw materials forms the backbone of breakthrough research and commercial success.