HS Code |
109863 |
| Product Name | 2,5-Dihydroxybenzoic Acid |
| Synonyms | Gentisic Acid |
| Cas Number | 490-79-9 |
| Molecular Formula | C7H6O4 |
| Molecular Weight | 154.12 g/mol |
| Appearance | White to off-white crystalline powder |
| Melting Point | 203-205 °C |
| Solubility | Soluble in water, ethanol, and acetone |
| Purity | Typically ≥99% |
| Application | Matrix for MALDI-TOF/MS |
| Storage Temperature | 2-8 °C |
| Pka | 2.97, 10.71 |
| Ec Number | 207-760-6 |
As an accredited 2,5-Dihydroxybenzoic Acid [Matrix for MALDI-TOF/MS] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 25g amber glass bottle labeled "2,5-Dihydroxybenzoic Acid [Matrix for MALDI-TOF/MS]", Sigma-Aldrich chemical grade, tightly sealed. |
| Shipping | 2,5-Dihydroxybenzoic Acid [Matrix for MALDI-TOF/MS] is shipped in tightly sealed containers, protected from light and moisture. It is classified as non-hazardous for transport, but should be handled with care. Shipped at ambient temperature, with proper labeling according to chemical safety regulations from suppliers such as Sigma Aldrich, Merck, or TCI. |
| Storage | 2,5-Dihydroxybenzoic Acid [Matrix for MALDI-TOF/MS] should be stored tightly closed in a cool, dry, well-ventilated area, protected from light and moisture. Recommended storage temperature is 2-8°C (refrigerator). Use only with appropriate personal protective equipment. Avoid contact with incompatible substances such as strong oxidizers. Refer to product SDS for additional safety and storage information. |
Competitive 2,5-Dihydroxybenzoic Acid [Matrix for MALDI-TOF/MS] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As a manufacturer with decades of hands-on production, we find 2,5-Dihydroxybenzoic Acid—often called DHB—taking center stage in many of our customers’ analytical workflows. Research and diagnostic labs rely on it for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS), an indispensable technology for investigating biomolecules like proteins, peptides, oligosaccharides, lipids, and even polymers. In our experience, technical staff never want to leave anything to guesswork, especially in high-stakes proteomic or clinical studies. Repeatable and robust data begins with the right consumables, and the quality of the matrix directly shapes the quality of the answer.
Several matrices have their strengths and weaknesses, but DHB stands out when you look for versatility and good ionization efficiency across a wide mass range. It blends well with many sample types—tough agricultural samples, environmental extracts, or complex biological fluids—without introducing background noise that would obscure weaker signals. For researchers exploring complex mixtures or complicated post-translational modifications, that clarity proves vital. We’ve watched users shave hours from troubleshooting simply by using high-purity DHB, getting sharp, clean peaks when others falter.
Batch-to-batch consistency matters to every project. Mass spectrometry labs trust DHB that doesn’t chase the highs and lows of impurity profiles. We control raw materials tightly and tune every crystallization step for repeatability. The result is a product with optimal dye content and minimized UV-absorbing contaminants, both of which help avoid baseline lift and ghost peaks during laser desorption. The color should remain white to slightly off-white, and that visual cue shows the care gone into the purification.
Spectroscopic purity always ranks high. Labs count on DHB with UV absorbance in the sub-0.10 range near 266 nm. Our process minimizes extraneous aromatic side-products that often slip into the mainstream supply chain, especially from poorly maintained or scaled-up reactors. Careers in process chemistry teach that a little extra diligence goes a long way: skipping a washing step or pushing a drying cycle too fast translates into more unknowns down the line. Those unknowns sap the confidence of anyone who values machine accuracy.
We run every kilogram of DHB through a regimen of physical and chemical checks, from melting point confirmation (not just a test for show, but a tried-and-true method for uncovering latent contamination) to spot checks using high-resolution LC-MS/MS alongside routine thin-layer chromatography. We avoid single-parameter guesses. MS users typically prepare saturated or near-saturated DHB solutions in solvents like 30-70% acetonitrile/0.1% TFA or ethanol. The solubility curve has to align with classic specs, otherwise crystal coverage on target plates becomes unpredictable. Reliable crystal growth on the MALDI target means more uniform energy absorption by the sample, leading to less shot-to-shot variability and clearer analyte signals.
In our own work, we’ve seen products that technically qualify under compendial grades but fall short in reproducible matrix application. A slight deviation in particle size distribution or residual solvent content can contribute to pipetting headaches and odd drying patterns on the plate. We emphasize gentle grinding and optimized desiccation, keeping moisture at bay without baking away volatile acids or forming aggregates that clog filters. Our technical records show labs stay productive longer when the powder flows as expected and dissolves with little coaxing.
Within the MALDI-TOF workspace, 2,5-Dihydroxybenzoic Acid belongs to a trusted group of organic acids used to facilitate desorption and ionization. Each matrix comes with its sweet spots and drawbacks, and over the years we've guided countless labs in selecting the best fit. For peptides and full proteins, sinapinic acid or α-cyano-4-hydroxycinnamic acid (CHCA) often take the lead, but DHB’s broader mass range and tolerance for heterogeneous mixtures set it apart when analyte size or complexity ramps up. In glycoprotein mapping or lipidomics, DHB often yields cleaner spectral fingerprints than CHCA, which sometimes biases heavily toward smaller molecules.
The crystallization behavior on the plate is another area where DHB shines. Whereas sinapinic acid can form large, inconsistent crystals that frustrate users seeking high spatial reproducibility, DHB forms a dense microcrystalline layer. This property leads to higher sample coverage, so users waste less time searching for good spots under the laser. Every analyst we talk to mentions how frustrating it feels to spend half a day darting around the target only to find their sample hasn’t incorporated well with the matrix. With DHB, well-controlled humidity and solvent ratios produce reliable, repeatable outcomes.
Sensitivity and analyte suppression also mark important points of difference. CHCA sometimes suppresses higher-mass ions, shrinking the dynamic range for larger molecules. DHB, on the other hand, manages to capture both low- and high-mass ions, though at times with slightly lower absolute resolution for low-mass peptides compared to CHCA. Certainly, individual applications dictate the optimal matrix, but pharmacologists and clinical chemists alike often find DHB broadens what they can analyze in a single run, especially useful for quick mapping or when chasing unknowns.
Over the years, we’ve worked alongside academic and industrial partners who depend on every parameter behaving as expected. Some labs map protein breakdown in disease research, and others survey environmental toxins in plant extracts. A common thread is that nothing stops productivity faster than erratic signal intensities, shifting baselines, or unexplained new peaks. Every aspect of our DHB’s design aims to eliminate those potential disruptors.
Manufacturing millions of grams through tightly regulated workflows gives us a clear window into what users need. Small changes in the molar ratio during crystallization, residual solvent profile, or storage handling can show up as day-to-day noise in the MALDI instrument room. We’ve found that focusing on meticulous drying and double-stage grinding grants powders that stay free-flowing and quickly dissolve at typical working concentrations, usually above 10 mg/mL in acetonitrile/water or methanol/water. By avoiding amorphous or clumpy granules, we help analytical teams focus on their research—not on troubleshooting spots.
Many teams investigate large numbers of clinical or environmental samples. Contamination from phthalates, aromatic chlorides, or sulfones can sneak into poorly monitored chemical streams. We screen every finished lot of DHB for these classes of impurities, updating protocols as detection technology improves. This dedication helps uphold reliable hands-off automation, particularly in clinical settings where repeatability governs diagnostic value.
Shipping and storage sometimes challenge chemical stability. DHB responds well to sealed packaging with silica desiccants, which we recommend to preserve the microcrystalline structure. Handling in open air for prolonged periods can shift the moisture content just enough to affect weighing accuracy or solution preparation. As a habit, our customers transfer DHB to secondary airtight vials if longer-term storage is required.
One key area that pushes product performance is reconstitution in acetonitrile/water mixtures. Our experience has shown that gentle vortexing and avoiding excessive sonication helps maintain the fine crystalline forms that dissolve fastest. High-purity solvents remain important, as trace impurities in the solvent can aggregate with the matrix, leading to irregular crystal formation after application on the MALDI plate.
In clinical proteomics or biopharma environments, where throughput and accuracy matter daily, small investments in clean glassware, consistent pipetting, and well-maintained target plates extend the value of a high-quality DHB matrix. We also see teams favor automated spotters for large batch projects, which further reward the even powder size distribution our product offers. Consistency at each process stage accumulates, delivering lower sample-to-sample variability and sharper results.
Vacuum drying freshly prepared solutions uncovers another tip: removing dissolved gases and minimizing atmospheric moisture uptake before application leads to fewer matrix droplet artifacts. Even with DHB’s relatively forgiving behavior compared to more hydrophilic or hydrophobic matrices, we recommend standardizing the drying environment, especially in highly regulated labs.
Industry and academic partners often ask for detailed documentation on every DHB lot. Full certificates of analysis ride with each shipment, covering more than the regulatory minimums. Labs face rising scrutiny over batch data and the exact analytical profile of their consumables. To support that, we archive all chromatographic, spectroscopic, and impurity analyses for more than a decade. This isn’t just an internal safeguard; it reflects our belief that full transparency makes research stronger and faster.
Unlike some intermediaries, we do not dilute purity claims or aggregate lots without full cross-lot profiling. End users, especially in regulated spaces, quickly discover when shortcuts in manufacturing or packaging introduce batch drift or cross-contamination. Thanks to our integrated plant controls and tailored QC, our DHB regularly exceeds the purity benchmarks set by pharmacopoeial standards and internal customer audits.
One of the most important aspects is minimizing batch-to-batch drift. We observe the biological community pivoting toward open-access data and broad sharing of protocols. Having low-variance, transparent matrices means studies can be harmonized and replicated across labs and continents. Chemical traceability matters deeply to that process, as does quick access to full spectral data—both features we build into our offering.
We’ve frequently worked with labs facing difficult spectra plagued by tailing peaks, unexplained background, or inability to reproduce known results from literature. A surprising number of those issues trace back to insufficient matrix quality or inconsistent application. For this reason, we open our technical archives and production histories to users seeking answers. Many manufacturers claim high specs, but our aim is to troubleshoot and improve—not to simply push product.
Our team tests not only using textbook standard samples, but also user-contributed samples that mimic the broad reality of field work. Whether its disrupted tissue, weathered plant matter, or polymer blends, we challenge our DHB with the full spectrum of analyte complexity. Inside the production plant, we’ve rebuilt packaging and grinding lines in response to repetitive feedback about powder flow and crystal habit. That cycle of feedback, adjustment, and re-validation shapes a product that solves more real-life problems.
Modern manufacturing must grapple with its ecological responsibilities. DHB production, like most specialty chemical processes, brings solvent recycling, energy monitoring, and waste minimization to the fore. Over the past decade, we’ve retooled our synthesis reactors to cut solvent losses to less than 2% per cycle. Downstream, active carbon and advanced phase-separation minimize run-off and ensure that purification stages do not outsource ecological harm downstream.
We source raw phthalic precursors and hydroquinone under strict supply-chain controls, preferring vendors with certified environmental standards and published emissions targets. On the waste management side, we operate under closed-loop water wash cycles and recover over 90% of spent solvents for reprocessing—not all manufacturers can claim such high rates, and neglect in these areas frequently shows up as off-flavors in downstream chemical streams.
Packaging, too, has evolved in response to user feedback. We’ve switched to HDPE jars with low-leachable, antistatic linings, making them easier to recycle and less likely to degrade handling safety during storage. These materials keep water and oxygen transmission below industry averages, keeping our DHB as stable in the lab as it left the plant. In practice, these choices mean less lab waste and fewer interruptions from unstable reagents.
Scientific research demands better sensitivity, faster throughput, and ever-increasing levels of reliability. In this context, we see ongoing advances in matrix chemistry—additives, alternative co-crystals, and hybrid matrices—expanding the range of molecules measurable by MALDI-TOF/MS. But the backbone remains classic, high-purity, well-characterized reagents produced to consistent standards.
We collaborate with end-users pioneering ultra-high-mass spectrometry or quantitative proteomics, and their needs keep nudging us forward. Whether that is stricter particulate size tolerances, solvent-free options, or packaging that supports robotic automation, our direction remains shaped by what frontline researchers need. What doesn’t change is the simple value of reproducibility: a bag of DHB that dissolves, plates, and ionizes the same way tomorrow as it did last week.
In the end, producing 2,5-Dihydroxybenzoic Acid that earns user trust takes more than chemistry textbooks and quality control lists. Success demands years of hands-on refinement, willingness to listen to what researchers actually face, and the discipline to keep raising the bar. That dedication shapes every step of our process and every lot of matrix we send out to the world. As mass spectrometry advances, the value of reliable foundations only grows in importance.