West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid [Good's buffer component for biological research]

    • Product Name 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid [Good's buffer component for biological research]
    • Alias HEPES
    • Einecs 220-372-0
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    712937

    Product Name 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid
    Common Abbreviation HEPES
    Buffer Type Good's buffer
    Molecular Formula C8H18N2O4S
    Molecular Weight 238.3 g/mol
    Cas Number 7365-45-9
    Pka Value 25c 7.5
    Effective Ph Range 6.8-8.2
    Solubility In Water Soluble
    Appearance White crystalline powder
    Storage Conditions Room temperature, dry place
    用途 Biological and biochemical research applications

    As an accredited 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid [Good's buffer component for biological research] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing A 100g white plastic bottle with a tight-seal cap, labeled with Sigma-Aldrich branding, product name, and chemical specifications.
    Shipping This chemical is typically shipped in tightly sealed containers to prevent contamination and moisture absorption. It is classified as non-hazardous, allowing for standard shipping. Temperature requirements are ambient unless specified otherwise. Packaging complies with regulatory standards and includes clear labeling for research use. Delivery is prompt, with tracking information provided.
    Storage 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid (HEPES), a Good's buffer used in biological research, should be stored in a tightly sealed container, protected from light and moisture, at room temperature (15–25°C). Keep in a dry, well-ventilated area, away from incompatible substances. Avoid prolonged exposure to air to prevent degradation and ensure consistent buffer performance in experiments.
    Free Quote

    Competitive 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid [Good's buffer component for biological research] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic Acid: Supporting Precision in Biological Research

    Why We Manufacture This Buffer

    In our experience as a chemical manufacturer, the quality of raw materials and the rigor of the production process count more than anything else in biological research. Over the years, we’ve heard the same request from researchers, biotechnologists, and lab scientists—they need a buffer system that can hold pH steady through lengthy, repeatable experiments without interfering with the system or damaging sensitive samples. That’s where 2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic acid comes in.

    Known in labs as HEPES, this buffer consistently earns its place on the bench not just for its chemical stability but also its low level of interaction with enzymes and other biomolecules. We focus on producing HEPES with tight control on trace metal levels and biological contaminants for one straightforward reason: batch-to-batch certainty.

    Understanding the Role of Good’s Buffers

    Good’s buffers changed the way researchers work with proteins, cells, and nucleic acids. Unlike traditional buffering agents like phosphate or Tris, which often introduce variables or shift osmolarity, HEPES holds pH reliably over extended time periods, even in the presence of CO2—a property critical in mammalian cell culture. The buffer exhibits minimal absorption in the UV range. This benefit keeps spectrophotometric assays clear of signal interference.

    Long experience has shown us that just because a buffer’s name appears on a list doesn’t mean every manufacturer’s offer measures up. Some suppliers ship product that introduces unwanted ions or inconsistent performance. That’s why we invest in our own purification steps and analytical testing: because we know our materials become part of our customers’ discoveries, not just a line in a protocol.

    Our Production Philosophy and Why It Matters

    We manufacture HEPES using a process that eliminates trace metals and organic impurities. Small oversights at this stage can undermine even the best-designed experiment. Throughout every step, we monitor the solution’s conductivity, UV absorbance, and pH. Analytical staff inspect every batch for particle contamination and bioburden. Our facility carries out GMP-compliant manufacturing, which means materials pass stricter checks than commodity-grade chemistry.

    The differences aren’t marketing claims. During fermentation processes, for example, instability or unknown contaminants can skew growth rates in microbial or mammalian cultures. By controlling each stage of synthesis and refining, we keep critical variables stable. It’s not enough to meet a published assay; researchers expect the same response from a buffer at the start and end of a multi-month project. That consistency is only possible with a manufacturing discipline built on real-world lab feedback.

    Physical and Chemical Details that Count

    We produce HEPES with a molecular weight of 238.3. Melting point, water solubility, and pKa—all of these numbers appear in catalogues, but what impacts your experiment is the real purity. We aim for ≥99% purity, free from DNase and RNase, and include detailed lot-specific data sheets with every delivery. Sulfonic acid functionality gives the buffer its strong pH-holding capacity between 6.8 and 8.2, so systems from cell cultures to protein isolation remain stable in the critical physiological range.

    Some researchers need granular details: moisture content, residual solvents, and the absence of heavy metals. We provide exact data on these parameters, not because regulations demand it but because scientists deserve full certainty from their suppliers. If the buffer carries even minute traces of copper or iron, downstream applications like mass spectrometry or sensitive redox reactions can fail. By addressing these factors during our in-house QC, we prevent expensive mistakes and wasted hours for those relying on our materials.

    Usage in the Lab—What Experience Teaches

    Our conversations with users—particularly those running time-sensitive cell cultures or protein purifications—underline the importance of buffer choice. In mammalian cell culture, for instance, HEPES proves especially valuable. Unlike bicarbonate buffers, which often require constant CO2 gassing, HEPES holds pH even if CO2 levels shift marginally. The result: healthier cells, reduced stress, and reproducible data from experiment to experiment.

    Protein purification brings its own challenges. Traces of organic acids or amines in other buffers can bind or modify target proteins. Thanks to its neutral character, HEPES avoids unwanted side reactions. Its compatibility with chelating agents and non-interference with enzyme assays makes it the clear choice for labs needing reliability over long, multi-step workflows.

    Absorption in the ultraviolet region stays low, which matters for chromogenic substrate work or high-sensitivity absorbance readings. Some researchers encounter background noise with Tris or phosphate; switching to HEPES eliminates variable peaks, letting genuine results appear without extra troubleshooting or assay redesign.

    Comparisons with Other Good’s Buffers

    Experience confirms that buffer selection isn’t interchangeable—it shapes everything from experimental setup to the quality of downstream results. MES, another Good’s buffer, offers strength in acidic pH (5.5–6.7), but lacks the flexibility needed for cell culture or studies that require near-neutral conditions. CHES goes more basic, useful for certain biochemistry protocols in the 8.6–10 pH range. HEPES fills a much-needed gap, anchoring pH right where most physiological reactions occur.

    Our R&D teams have tested HEPES against less-specialized products, such as phosphate or Tris. We see greater resistance to temperature variability and improved integrity after long-term storage. Unlike Tris—which demonstrates notable temperature sensitivity—HEPES keeps its buffering capacity in both refrigerated and ambient storage, and through cycles of warming and cooling. Even in samples subject to repeated freeze-thaw cycles, our high-purity HEPES does not precipitate or degrade, safeguarding the repeatability of high-throughput studies.

    Addressing Common Challenges in Buffer Performance

    Researchers sometimes report setbacks tied to the hidden chemistry of lab reagents. With buffers, the issue often comes from the unnoticed presence of impurities—nickel, zinc, or nonspecific bioburden. We’ve seen these issues disrupt PCR reactions, protein crystals, or even the health of precious primary cell lines. That’s why our approach focuses on rigorous metal-removal and tight microbial limits.

    Another concern comes from day-to-day handling. Some buffer materials clump, cake, or degrade after exposure to humidity during storage. Our production prioritizes finely milled, free-flowing powder with controlled moisture content, reducing the chance for clumping and speeding up solution preparation in the lab. We pack our product in tamper-evident, moisture-blocking containers, and lab staff appreciate the ease of weighing and dissolving the powder without hidden residues left in the flask.

    Supporting Reliable Research with Traceability

    Being in the manufacturing business, we know scientific integrity relies on product traceability and transparency. We document every batch from raw material source to final packing. Full chromatograms, ICP-MS reports for metal analysis, and documented microbial testing travel along with each shipment. In regulated environments or academic settings alike, these records stand behind every experimental result published from our customers’ work.

    Occasional mistakes in the supply chain cost more than just lost time. If a buffer fails to meet ultra-low pyrogen or endotoxin standards, entire cell therapy or vaccine campaigns could falter. That’s why our process puts traceability and documentation before shipment, not as an afterthought. Fit-for-purpose means more than meeting a minimum standard—it means scientific progress can continue without worry about invisible contaminants.

    Listening as Much as Leading

    Over the years, we’ve learned just how different one research environment can be from another. A university lab concerned with enzyme kinetics requires something different than a diagnostic kit producer or a biotech startup scaling up for clinical-grade production. Through ongoing conversations and collaborative feedback, we tune our process to match evolving needs. If an academic partner reports difficulty dissolving a competitor’s buffer, we adjust our particle-size distribution. If a biotech company requires confirmation of zero-animal origin for regulatory approval, our production line provides it, with documentation to match.

    Sometimes a new analytical technique catches on. If it demands specification for a rare parameter—say, extremely low background fluorescence or an extra step in ion analysis—we expand our testing panel and update our published results. Listening directly to technical staff from front-line labs shapes each improvement in our product. It’s not just about staying competitive—it’s a commitment that the material going into a tube or plate is suitable for the science those researchers hope to achieve.

    Enabling Next-Level Biotechnology

    The tools of gene therapy, immunotherapy, and synthetic biology now rest on a foundation of reliability. CRISPR workflows, protein mass spectrometry, antibody engineering—they’re all sensitive to the smallest changes in buffer composition. We recognize our responsibility to keep pace, updating our batch records and production technologies as analytical requirements increase in complexity. HEPES, for all its seeming simplicity, carries a weight of expectation in every experiment that touches it.

    Whether delivering product to a national research institute or a specialty CRO, our daily work emphasizes direct solutions to the most pressing lab problems. Shipping on ice during months of high heat, providing pre-weighed aliquots to minimize handling, or validating that our buffer won’t contribute spurious peaks on triple-quad mass spectrometers—we solve challenges with a view toward the usefulness of every gram of material we produce.

    Prepared for Change and Innovation

    Production standards change and customer expectations evolve. Our ongoing work involves refining batch sizes, introducing new packaging formats, and extending shelf-life through improved moisture barrier technology. If gene-editing techniques demand extra-scrupulous ultrafiltration, we scale our purification accordingly. When researchers ask for single-use, DNase/RNase-certified packaging for field diagnostics, our team develops the solution and incorporates it into standard offerings.

    Good’s buffers sit at the crossing point of tradition and innovation. As researchers push boundaries on sensitivity and throughput, we support them by updating process controls, tightening spec ranges, and sharing best practices for storage and reconstitution. By approaching each step as integral to the research community’s goals, we ensure our buffer keeps facilitating discovery rather than limiting it.

    Minimizing Risk and Maximizing Value

    Every successful experiment stands on the trust built between supplier and laboratory. We don’t chase cost savings at the expense of purity because any short-term gain gets erased by long-term risk. Instead, our production line prioritizes lot reproducibility, contamination prevention, and detailed record-keeping—each delivering real value over years, not just across purchase cycles.

    The companies and researchers who rely on our buffer aren’t only buying a chemical—they’re securing a track record of scientific progress uninterrupted by uncertainty or avoidable troubleshooting. Reliable, consistently high-purity HEPES makes the difference that isn’t always evident until an experiment works better, a protocol holds steady, or a paper gets published with clean, defensible results.

    Guiding the Next Generation of Buffer Technology

    We see the conversation moving forward as research breaks through old limitations. With personalized medicine, high-sensitivity diagnostics, and regenerative medicine pushing the envelope, demand grows for buffers that support new types of bioactivity and measurement. We engage with thought leaders and laboratory scientists alike, collecting feedback that feeds back into our research, informing how we adjust production, refine testing protocols, and introduce future product variants.

    Scientific progress depends on materials that don’t compromise. Through quality by design, strict process validation, and taking accountability for every lot, we reinforce trust within the research community. For us, every container of HEPES reflects not just a manufacturing run but an ongoing relationship with the end users who shape the future.

    HEPES: More Than Just Chemistry

    Manufacturing HEPES has taught us as much about people as about organic chemistry. From startup scientists to world-class universities, the trust in our process proves crucial time and again. Each improvement to our buffer comes not from boardroom mandates but from direct dialogue with those performing the research—solving overlooked user problems, providing more rapid customer support, or expediting delivery during time-sensitive studies.

    Our work supports global advancements in biology, biotechnology, drug discovery, and health. We see ourselves not just as a supplier but as a partner, sharing in the outcomes of every experiment, every publication, and every breakthrough our buffer helps enable. The story of HEPES in biological research continues to evolve, and as manufacturers, we stay committed to making sure the next chapter stands out for quality, transparency, and scientific integrity.