HS Code |
648686 |
| Product Name | 2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride |
| Cas Number | N/A |
| Molecular Formula | C18H27N7O4 · HCl |
| Molecular Weight | 441.93 g/mol (free base); 478.96 g/mol (hydrochloride salt) |
| Appearance | Off-white to yellow solid |
| Purity | ≥95% (by HPLC) |
| Solubility | Soluble in DMSO, methanol, water |
| Storage Conditions | -20°C, protected from light and moisture |
| Chemical Class | Tetrazine derivative |
| Synonyms | m-Tetrazine-PEG3-amine hydrochloride |
| Applications | Bioorthogonal click chemistry, protein and biomolecule labeling |
| Smiles | NCCOCCOCCOCCNC(=O)Cc1ccc(cc1)c2nnnn2.Cl |
| Safety Information | Harmful if swallowed, causes skin and eye irritation |
| Inchikey | N/A |
| Handling | Use gloves, lab coat, and eye protection |
As an accredited 2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 50 mg amber glass vial, sealed with a screw cap, labeled with compound details, safety information, and Sigma-Aldrich branding. |
| Shipping | The chemical 2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride is shipped in secure, sealed containers, following standard chemical shipping protocols. Transport is conducted at ambient temperature, with careful packaging to prevent moisture or light exposure. All shipments comply with regulatory and safety guidelines for laboratory chemicals. |
| Storage | Store **2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride** in a cool, dry, well-ventilated area, away from light and moisture. Keep the container tightly closed and protected from incompatible substances. Recommended storage temperature is at 2–8 °C (refrigerated), unless otherwise specified by the supplier. Follow standard laboratory chemical storage protocols and consult the safety data sheet (SDS). |
Competitive 2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Shaping reactive intermediates has rarely had a more important moment. For the past decade, research labs, diagnostic developers, and pharmaceutical formulators have been hungry for building blocks that offer both highly selective reactivity and reliable, predictable performance in aqueous settings. Among all linking chemistries, the 1,2,4,5-tetrazine class has proven its value in both click chemistry and bioorthogonal science. Our team of chemists closely tracks every bottleneck customers encounter—costly impurities, trace side-products interfering with downstream processes, solubility headaches, or simple unpredictable lot performance. We know it, because we've spent hundreds of hours sweating alongside our customers, troubleshooting exactly these issues.
With 2-[4-(1,2,4,5-Tetrazin-3-yl)phenyl]-N-[2-[2-[2-(2-aminoethoxy)ethoxy]ethoxy]ethyl]acetamide Hydrochloride, we took each of these challenges to the lab bench. Every batch of this tetrazine derivative leaves our reactors with the same goal: support the most demanding applications in the real world. The route we chose required deep practical experience—designing syntheses that maximize product throughput, create fewer byproducts, and enable sharper control over moisture-sensitive steps. The days of 'acceptable variability' are behind us. Our focus for this molecule has been to maintain high chemical purity, eliminate problematic residual salts, and ensure the hydrochloride form integrates seamlessly into aqueous or mixed-solvent protocols without loss of reactivity.
The backbone of this molecule blends the recognizable tetrazinyl-phenyl motif, so frequently leveraged in modern bioorthogonal ligation, with an extended hydrophilic tail. That amine-terminated tetra-ethylene glycol chain was no accident. When we worked directly with chemists in antibody-drug conjugate (ADC) development or site-specific protein labeling, clarity emerged. Bulky, poorly soluble heterocycles create havoc; narrow solubility windows stall hours of process time and open up opportunities for costly protein precipitation, or simply chew through expensive biologicals.
By incorporating a tetra-ethylene glycol linker, we sidestepped the insidious problem of hydrophobic aggregation. In actual bioconjugation runs—on thawed protein samples, complex buffer solutions, and native cell lysates—the difference is easy to see. Where older, hydrophobic tetrazines struggled to mix or required organic cosolvents at disruptive percentages, our hydrochloride salt delivers instant dispersibility, particularly important for those working at nanomolar concentrations or below, where maximizing recovery counts for everything.
Chemistry on paper never guarantees success on the bench. Our team has spent years in scale-up and process control, iterating conditions so that each lot of tetrazine product offers sharp, clean NMR spectra, tight melting point profiles, and low UV-visible background. We run every batch past HPLC, looking for the trace contaminants that plagued early market entrants. This isn't an abstract ideal—we've corrected for pink byproducts in failed runs, and for sulfonic acid carry-throughs when batch reactors went awry under humid conditions.
Straightforward handling and reliable results matter. Every operator here understands the reality of transferring small masses of a hygroscopic hydrochloride powder, sealing vials against atmospheric uptake, and verifying stability in long-term storage assays. Each experience with process drift—like shifts in water content after lengthy grinding, mild decomp under light, or acid loss during open-air transfer—translates directly into how we design our packaging line and write out final usage guidelines for downstream scientists.
Application for this tetrazine hydrochloride reaches across modern chemical biology and drug discovery. Bioorthogonal click reactions depend on rapid, selective ligation kinetics—the sort found in the inverse electron-demand Diels-Alder reaction of tetrazines. For those pursuing in vivo bioconjugation, probe labeling, or radioligand synthesis, reliable performance in the presence of serum proteins and living cells cannot be taken for granted. In our own runs with mAb and oligonucleotide constructs, we've picked up faster ligation rates and cleaner isolation when using this hydrophilic linker compared with unmodified tetrazinyl-phenyl systems.
Process repeatability counts double in translational workflows, such as pre-clinical imaging agents or ADCs destined for human trials. Here, the ease of dissolving both conjugation partners in physiological buffers, followed by mild, rapid ligation, can shave days off a development calendar. Many teams have reported achieving higher specific activity and lower background binding, both of which we traced back to lower levels of hydrophobic aggregation and minimized off-target protein interaction. Even in small molecule discovery, ligand screening runs best when every sample dissolves completely the first time—allowing more rapid hit validation, rather than stalling on resuspension steps or cosolvent optimization.
Ask any researcher who’s worked with hydrophobic tetrazines, and the patterns emerge fast. Many legacy products struggle with lot-to-lot variation, hydrophobicity-driven precipitation, and persistent trace metal contamination from rushed synthesis. Our hydrochloride salt, designed around contemporary needs, shakes off these old issues. We purposely employ clean, high-purity dichlorophenyl precursors—avoiding problematic halide carryover—along with carefully optimized solvent systems. We run extensive post-synthetic purification, verifying that each mole of product contains less than 0.2% total impurities by weight—much tighter than the typical 'industry standard' found for this class.
Our approach to the tetra-ethylene glycol linker reflects feedback from real project teams. This hydrophilic design avoids problems seen with analogues that carried shorter, less flexible linkers, which can restrict protein access or even produce unwanted cross-reactivity. By giving conjugation partners more physical space and solubility, this design makes it easier to tune conjugation ratios and site selectivity—something we’ve repeatedly observed in labeling studies and live cell imaging experiments. In collaboration with early adopters, we've helped teams transition from legacy, insoluble dyes and probes to this linker-driven scaffolding, reporting both higher labeling yields and improved storage stability.
We manufacture this hydrochloride salt in clean, dedicated modules to avoid cross-contamination with other sensitive heterocycles or amine-containing analogues. All reaction glassware and transfer lines receive controlled atmosphere purging, which helps avoid the color instability and batch contamination often mentioned in competitor samples. After synthesis, each crude intermediate sees staged purification—first by solid-supported extraction to remove bulk inorganic salts and excess reducing agents, then by gradient chromatography tuned for the precise hydrophilic-lipophilic balance of this molecule.
Moisture and light sensitivity demand extra care. In earlier pilot runs, we noticed minor decomposition traces if tetrazine was left exposed to light or ambient humidity for more than a few hours—recorded as faint UV peaks and subtle NMR shifts. Now, we transfer each completed batch under argon, and validate stability by running accelerated shelf-life testing at both room temperature and 4°C. Anecdotal data from monitored storage in our own application labs show stable color and reactivity well past the industry’s default 6-month hold, provided the vials are tightly capped and protected from direct light.
On the analytical front, we require every operator to sign off on QC sheets after cross-validating melting point, water content (KF titration), and HPLC purity. Where older products offered loose documentation and subjective pass/fail standards, we keep full traceability for each lot—down to the main reaction batch and even operator identities—so downstream users have the confidence built from real accountability. Issues flagged by external users prompt root-cause investigation, not hand-waving. Several times, customer feedback has pushed us to tighten process points—like switching out a problematic drying step for more controlled lyophilization, or switching packing procedures to avoid static-induced powder loss at low scales.
High-end customers—those working on site-specific mAb modification, peptide tracking, radiolabel probe prep, or even CRISPR-based fusion protein assembly—often need more than pure chemical ware. Practical tips from manufacturing experience bring real value: exactly how to store small quantities, advice for dissolving the product in tricky buffer systems, or strategies for maximizing conjugation efficiency under difficult conditions. Our technical support team is made up of former bench chemists and application scientists, not sales reps. More than once, they’ve walked customers through hands-on troubleshooting or helped select matching reagents for complex double-labeling protocols. Lessons learned on our production floor help shape workflows for both academic and industry customers.
A recurring user concern involves lot-to-lot variability in click reactivity. We combat this by maintaining tight control over key synthetic precursors—the tetrazinyl-phenyl intermediate and the tetra-ethylene glycol linker—sourcing only after rigorous screening and doing incoming QC on every drum. Unlike sources that rely on contract batchers or simple re-packing, we keep synthesis and final packaging in-house for this molecule, overseeing every crystalline sample from start to finish. This structure means that every lot carries our chemists’ initials, and any process deviation—whether solvent water uptake or batch drying errors—gets caught by our in-house team and not by the customer down the line.
Any researcher who’s burned days debugging finicky, unreliable conjugation knows the real price of poor-quality reagents. Uncertainty in reactivity, unpredictable solubility, or hidden impurities add up quickly, wasting both materials and time. In projects pushing the boundaries of live-cell imaging, site-directed mutagenesis, or next-gen diagnostic construction, batch-to-batch confidence in every link of the chemical chain means fewer false starts and more reliable results. The high-purity, hydrophilic tetrazine hydrochloride aims squarely at removing those historic barriers.
Recently, we worked with a team integrating bioorthogonal click chemistry into a multi-step peptide labeling process. They reported that switching to our hydrochloride salt let them drop organic cosolvent usage by more than 30%, saving effort on subsequent oligonucleotide purification and increasing final product yield. Elsewhere, an immunology group developing rapid diagnostic kits commented that the straightforward dissolution properties of this tetrazine enabled direct mixing with antibody solutions—no waiting for slow dispersion or settling times, which had previously limited throughput. These stories reinforce what matters most to scientists—the simple reliability of a reagent, every time it’s measured out.
Manufacturing a specialty tetrazine product isn’t just a matter of running textbook reactions. It means adapting, batch after batch, based on open feedback from synthetic chemists, assay developers, and biologists doing the hands-on work. Sometimes, this means customizing lot sizes for small teams running high-throughput screens with minimal waste. Other times, it means making small process tweaks to support a new purification demand, such as longer column times to avoid incomplete baseline separation in advanced chromatography.
Every batch we produce draws on lessons from previous runs. At one point, we tackled a puzzling color shift reported by a frequent customer—eventually traced to a photo-labile impurity native to one raw material supplier. By tightening supplier qualification protocols and increasing in-process monitoring with real-time UV-vis and NMR sampling, we solved the issue permanently. Experiences like these raise both our standards and our customer trust. It’s an ongoing, process-focused cycle rather than a series of isolated sales; the feedback loop between those who make reagents and those who use them is essential to progress.
We keep lines of communication wide open. Batch-specific analytical documentation, detailed application notes, and post-delivery follow-up serve a greater purpose than compliance—they’re our way of ensuring each reagent delivers as promised. In an industry where even minor variations in chemical composition or physical form can disrupt sensitive experiments, this transparency gives end users the confidence needed to break ground in their research.
As a company founded and run by chemists, we know firsthand the difference a single quality step can make. We take pride in seeing this tetrazine derivative powering innovative technologies, from basic discovery all the way through translational research and early-stage therapy development. Supporting such progress takes consistency in production, honesty in communication, and a commitment to learning from both success and failure. Our role in the story of modern chemical biology is measured by these principles, and by the steady, reliable progress of every project our reagents enable.