|
HS Code |
110953 |
| Chemical Name | 2,2,4-Trimethylpentane |
| Common Name | Isooctane |
| Molecular Formula | C8H18 |
| Molar Mass | 114.23 g/mol |
| Cas Number | 540-84-1 |
| Appearance | Colorless liquid |
| Boiling Point | 99.2 °C |
| Melting Point | -107.4 °C |
| Density | 0.692 g/cm³ (20 °C) |
| Purity | ≥99% (HPLC Solvent Grade) |
| Refractive Index | 1.391 (20 °C) |
| Flash Point | -12 °C (closed cup) |
| Solubility In Water | Insoluble |
| Odor | Characteristic, gasoline-like |
| Autoignition Temperature | 415 °C |
As an accredited 2,2,4-Trimethylpentane [for HPLC Solvent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 2,2,4-Trimethylpentane for HPLC Solvent is supplied in a 2.5L amber glass bottle with tamper-evident cap, Sigma-Aldrich. |
| Shipping | 2,2,4-Trimethylpentane [for HPLC Solvent] is shipped in tightly sealed, chemical-resistant containers, compliant with hazardous material regulations. Packaging ensures minimal exposure to air and light, with proper labeling for flammability and chemical safety. Suitable for Sigma Aldrich, Merck, or TCI chemical grade, transport follows international DG (Dangerous Goods) guidelines. |
| Storage | 2,2,4-Trimethylpentane (HPLC grade) should be stored in a tightly sealed container in a cool, dry, well-ventilated area away from heat, sparks, open flame, and strong oxidizing agents. Keep away from direct sunlight and sources of ignition. Store at room temperature and label the container clearly. Refer to the manufacturer’s safety data sheet (SDS) for specific storage recommendations. |
Competitive 2,2,4-Trimethylpentane [for HPLC Solvent] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
From the earliest stages of chemical manufacturing, precision has always ruled the outcome—especially when refining 2,2,4-Trimethylpentane for High Performance Liquid Chromatography (HPLC). Over many production cycles, we've learned how even minor fluctuations during distillation or purification translate into measurable effects on chromatographic background, retention times, and quantitation linearity. Choosing a 2,2,4-Trimethylpentane—often referred to as iso-octane—that consistently meets the needs of analytical labs grew out of a focus on controlling every variable we could directly influence within the plant.
To us, 2,2,4-Trimethylpentane feels different from so many other reagents. Its structure—eight branching carbon atoms—delivers low polarity, high volatility, and a steady baseline through the injector and columns. As a component in mobile phase composition, this solvent stands out for its chemical inertness. Many solvents tempt users with broad claims of compatibility. We've tested most of them, repeatedly, and seldom do they match the purity and signal stability we can deliver for HPLC-specific requirements.
Clean chromatograms depend on what goes into the bottle—not just the chemical name on the label. We follow a production approach that watches every potential source of trace impurities. Starting batches use only premium feedstock, passed through custom-built fractional distillation systems. The column packing, reflux ratio, and condenser materials—all influence trace content of n-hexane, heptanes, or cyclic contaminants. Early on, we discovered that the smallest levels of nonalkane species, sulfur, or oxygenates left hidden peaks within baseline traces. These could mask or mimic target analytes.
We run each lot through a series of purity checks uncommon in bulk solvent production. Gas chromatographic fingerprinting with flame ionization detection checks aliphatic composition. Residual water and trace aldehyde levels get monitored by Karl Fischer titration and colorimetric assays. Our routine pushes beyond generic standards and guarantees no hidden surprises for the user running highly sensitive HPLC protocols. The final product consistently delivers on purity, reaching levels such as 99.9% or higher, not just in paperwork, but batch-after-batch as confirmed by independent lab verification.
We produce our 2,2,4-Trimethylpentane under tightly controlled model lines developed for analytical customers. Each container—whether 2.5-liter amber glass or 20-liter steel drum—follows rigorous internal testing protocols. We track everything by batch number and run expiration studies under accelerated conditions, not just to meet shelf-life, but to uncover potential unknown degradation routes in long-term storage.
Real-world HPLC labs brought color and urgency to our learning curve. Sample injection systems can be unforgiving—spiking noise, baseline drift, unexpected "ghost" peaks. Most times, these traces come not from the analyte, but from solvent backgrounds. That's why each model line is bottled after extensive system flushes and under nitrogen to lock down peroxides, photo-oxidation products, or atmospheric contamination before the seal closes.
Over the years, many labs shared frustration with mass-market solvents that promise high purity on technical sheets but don’t deliver in application. We see this difference plainly. In our own QC labs, 2,2,4-Trimethylpentane outperforms other n-alkanes like heptane, hexane, or even cyclohexane on volatility, baseline steadiness, and resistance to forming residues.
Chasing lower detection limits or establishing precise retention intervals, every variable matters. Iso-octane’s boiling point near 99°C and low affinity for water mean less background absorption and sharper solvent front resolution—less chance for cross-contamination from prior injections, less memory effect between gradient runs. Where other solvents leach plasticizers or leftover processing residues, our HPLC-grade product runs clean batch-after-batch. This keeps maintenance predictable. The result is less downtime, more reproducible results, and a high degree of confidence for labs working in sensitive analysis like pharmaceuticals, petrochemical tracing, or food safety.
Anyone making premium laboratory solvents at scale knows the temptation to loosen up once systems run "well enough." Early on we tried streamlining our fractionation. When we did, problems showed up in chromatograms sent back from our most demanding partners—a slow, rising hump at the base; low-level tailing in internal standards. These weren't catastrophic, but they broke trust. Chasing these ghost peaks took us back through days of data logs and batch histories. We discovered that switching out just one valve or brief exposure to atmospheric air in a storage tank could make a measurable difference.
Those experiences taught us the importance of consistency and traceability—why every tank, pipe, and accessory needs cross-validated cleaning cycles and why batch records never take shortcuts. This commitment costs more, especially at the scale we run, but we know what’s at stake for the working analyst. Every lot, every time, must stand up to the most sensitive instruments because for many in the lab, there’s little room for error or analytic drift.
After decades of manufacture and shipping, many customers come to us for advice on storage or usage in real-world conditions. Iso-octane doesn’t evaporate as quickly as some lighter alcohols, but its volatility and low flashpoint call for certain precautions. We maintain strict drum sealing, nitrogen blanketing, and cargo separation during shipping. Even under secure packaging, the risk of static discharge or vapor buildup guides every transport decision.
In many countries, regulations for volatile organic compounds limit storage or transport options—one more reason we track solvent integrity from our plant through distributor delivery. We learned that drum material and headspace management matters, not only for security but for stopping peroxide formation under ambient light. Our technical team regularly consults on ways to minimize sample solvent contamination in end-user labs, from glassware selection to solvent-resistant tubing in HPLC lines. These little details add up to both safety and reliability in real-world usage.
Industry demand never slows, but pressure mounts every year to reduce environmental impact. 2,2,4-Trimethylpentane approaches environmental safety with a lower toxicity profile than many halogenated hydrocarbons. We run solvent recycling and waste-minimization lines across our plants, capturing, distilling, and purifying back what we can. Still, we cannot ignore the challenge of VOC emissions, both during production and at the end-user site.
From our vantage, the real responsibility begins before the solvent leaves the plant. Closed-system filling, vapor recovery, and full tracking of containers on return provide direct reductions in emissions and landfill loads. It’s not the sort of work that appears in glossy product write-ups, but customers relying on HPLC-grade solvents increasingly ask the right questions: Where was this made? How much was reclaimed? What’s the carrier for used drums back from labs? We believe quality starts with stewardship, and we keep working toward closed-loop manufacturing.
Raw solvent performance means little if it can’t work with today’s demanding HPLC systems. We calibrated each production line to target the most popular autosampler pumps, injector valves, and detection systems. Materials choice inside HPLC instruments keeps shifting. As more instrument makers move to advanced PEEK, PTFE, or stainless connections, past experiences have shown why non-reactivity and leachate-free performance matter.
We run accelerated compatibility testing under variable pressure and temperature. 2,2,4-Trimethylpentane stands apart from protic solvents like methanol or acetonitrile—both of which may interact with elastomeric seals. Iso-octane’s near-total immiscibility with water frees users from the trace swelling or surface residue often found following repeated injection runs. Many other alkane solvents introduce subtle surface tension changes, which in turn can play havoc with sample loading or standard curve accuracy.
The market teems with choices for HPLC solvents: n-hexane, heptane, cyclohexane, and hundreds of blends claim purity and low background. From our long association with chemical analysis labs, customers searching for absolute baseline flatness and low detection thresholds consistently choose 2,2,4-Trimethylpentane. Its physical properties—mid-range vapor pressure, chemical neutrality, and low UV absorbance—make it fit for binary or ternary elution cocktails, particularly when paired with modifiers.
We've tracked solvent lots through countless published studies where detection thresholds or calibration runs push below the parts-per-million mark. Most alkane solvents fail to provide the same repeatable injection pattern; iso-octane resists not just ghosting but chemical memory between runs. Even in splitless or temperature-programmed injections, iso-octane rarely interferes with downstream detection, whereas cyclohexane or aromatics can introduce background at challenging low wavelengths.
Our experience working with high-throughput screening facilities, research universities, and regulated QC labs taught us that no two setups are identical. Even a minor shift in solvent grade can impact ion suppression or baseline stability in complex gradient methods. Our technical support teams often walk labs through side-by-side trials: swapping our fresh HPLC-grade iso-octane in for aged or off-the-shelf alternatives. In nearly every case, assessments show reduced baseline drift, more repeatable peak symmetry, and, in some works, improved analyte recovery in multi-component blends.
We see labs working with pharmaceutical impurities—where every trace must be accounted for—benefiting from a solvent free of phthalates, mineral oil residues, or atmospheric picked-up volatiles. In environmental analysis, where polynuclear aromatics or volatile halides may appear at nanogram levels, iso-octane's ultra-low non-volatile residue count stands as an essential benchmark. Part of our ongoing process includes encouraging customers to share chromatograms, not only to catch anomalies but to refine our own process in response to the needs on the front lines.
Disruption in global logistics over the past years redefined how manufacturers must plan for solvent production and delivery. Tight border controls, raw material delays, and shifting import standards tested our ability to maintain batch quality without compromising on shipment deadlines. We responded by deepening stocks of purified feedstock, rerouting packaging materials through alternative suppliers, and investing in local transport options. We learned early on that a hiccup at any supply chain link risked impacting customers’ own compliance deadlines—especially for labs under regulatory scrutiny.
We maintain this level of preparedness, buffering not just against demand surges but against the risk of cross-contamination or quality dips from last-minute substitutions. Our plant staff remains in constant communication with logistics, ready to ramp up fill lines or expand quality checks as soon as disruption signals appear. For users, that means less downtime and the reassurance that solvent quality hasn’t dipped despite the supply turmoil. Beyond the paperwork, it’s a mark of the ongoing partnership between the analytical lab and the manufacturer.
Analytical chemistry doesn’t just chase numbers—it chases defensibility and regulatory acceptance. Over decades, we've worked alongside laboratories certified under ISO, GLP, or cGMP standards. Our lot certification, shelf-life tracking, purity analysis, and secure documentation feed directly into successful audits. Many labs run into trouble when documentation from traders or brokers can’t provide true lot histories or trace impurity profiles; our system keeps every record tied to specific manufacturing batches archived and ready for external review.
For the many applications where validation samples or proficiency testing demand exact matching between solvent lots, our dedication to traceable production ensures continuity. Our team stands ready to support customers facing new method certifications—pulling archived spectra, chemical analysis, and even providing comparison samples where needed.
No product line stands still. As demand and technology progress, so does the pressure to push detection lower, improve safety, and meet new environmental standards. Every year we test emerging purification technologies—vacuum distillation, adsorptive polishing, cutting-edge storage materials—so we can offer a better solvent for tomorrow’s HPLC protocols.
From the early days making drums for refinery research to the high purity grades needed for today’s bioanalysis, our experience guides us. We never settle for generic solutions. There’s no shortcut to customer trust or performance leadership, only the continuation of rigorous consistency and a willingness to learn from every batch, every complaint, every shared chromatogram. We believe 2,2,4-Trimethylpentane, made with care and delivered with integrity, stands at the core of reliable HPLC analysis for the future.