HS Code |
689371 |
| Product Name | 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic Acid |
| Cas Number | 14087-98-0 |
| Molecular Formula | C9H18N4O6 |
| Molecular Weight | 278.26 |
| Appearance | White to off-white solid |
| Solubility | Soluble in water |
| Melting Point | 220-225°C (decomposes) |
| Pka Values | 2.0–10.1 (multiple values) |
| Structure Type | Macrocyclic polyamine |
| Iupac Name | 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic acid |
| Storage Conditions | Store at 2-8°C, protected from light and moisture |
| Ec Number | 237-966-9 |
As an accredited 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic Acid factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The chemical is supplied in a 25g amber glass bottle with a white screw cap, labeled by Sigma Aldrich, for laboratory use. |
| Shipping | 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic Acid is shipped in tightly sealed containers to prevent moisture and contamination. It is typically transported at ambient temperature. Standard shipping follows local regulations for non-hazardous chemicals. Ensure the package is labeled and handled according to the safety data sheet provided by Sigma Aldrich/Merck/TCI. |
| Storage | **2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic acid** should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from incompatible substances and sources of ignition. Protect from moisture and direct sunlight. Store at room temperature (15–25°C), and follow all relevant safety and regulatory guidelines as per Sigma Aldrich, Merck, and TCI specifications. |
Competitive 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic Acid prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Working on 2,2',2''-(1,4,7-Triazonane-1,4,7-triyl)triacetic acid for years in our facility, we've watched its story develop far past the pages of technical catalogs. This compound, often referred to as NOTA in research circles, stands out as a chelating agent—a molecule that binds metal ions through several nitrogen and carboxyl groups in a single structure. Our teams handle NOTA as a solid white powder in drums or smaller packs, where stability, batch purity, and traceability matter more than fancy branding. Synthetic pathways have become more refined over time, pulling yields up and impurities down.
Several critical specifications come into play with this molecule: content usually exceeds 98%, and water content is always kept under tight control through drying protocols. Our experienced QC staff uses NMR and titration to verify the structural identity and purity, all under proper documentation and traceable storage. Over the years, the steady push for improved crystallization and filtration has reduced batch failures. We've learned that handling this compound requires patience—a little extra vacuum drying removes those last traces of solvent to keep unwanted ions from interfering when customers carry out their own reactions.
NOTA has a clear place in radiopharmaceuticals, where consistent binding of radioisotopes like Gallium-68 builds the foundation for diagnostic imaging technologies such as PET scans. Thin margins in isotope labeling mean that the smallest impurities show up as background noise, so our team pays close attention to minimizing heavy-metal traces in each batch. This keeps the background signal low—a big gain for diagnostic imaging specialists.
Researchers also look to NOTA for forming complexes with transition metals in catalysis and studying biological systems. We’ve shipped this compound to peptide synthesis labs, where it often gets attached to biomolecules—antibodies, peptides, or small drugs. The compatibility of NOTA with a range of solvents, and its lack of self-aggregation, makes life a little easier for anyone customizing their own molecular constructs.
Contrast this with other chelators such as DOTA or EDTA. DOTA has a bulkier, more rigid ring system, which creates complexes that often bind stronger but release metals more slowly. EDTA, known widely in cleaning, industrial, and diagnostic applications, forms less selective complexes—sometimes pulling unwanted ions along. NOTA brings just the right balance: a smaller cyclic backbone allows faster metal binding, and the three carboxyl arms maximize coordination without overcrowding. In every batch we produce, the aim stays clear—give researchers a chelator that delivers high selectivity and speed, especially in time-sensitive radioisotope work.
We’ve seen how seemingly minor tweaks in synthesis conditions alter product consistency. Elevated pH during ring closure can drive side product formation, while incomplete drying traps water, affecting chelating performance. Our technical crews calibrate mixing and heating equipment regularly, keeping an eye on real-time monitoring to flag emerging deviations early. We store analytical records for years, so that if a new problem shows up, it’s possible to trace issues down to the day, equipment, and person responsible.
Logistics often present less glamorous but equally important challenges. NOTA draws significant demand from research institutions across the globe, and shelf life matters. Improper storage can lead to caking or mild hydrolysis, especially if seals or drums let in ambient moisture. All output leaves our warehouses in sealed, double-bagged, moisture barrier containers. We review shipping records at monthly meetings, discussing temperature excursions or customs delays, because these can affect specification compliance as much as the chemistry itself.
The market for chelators is flooded with generics, but a surprising number of researchers circle back to source directly from manufacturers like us. Documented consistency, custom batch sizes, and tailored advice often tip the scales. There’s a quiet pride among our synthesis staff because feedback from end-users—whether it’s a pharmaceutical scientist or a nuclear medicine technician—flows back to the production bench. Adjustments in wash solvents, purification steps, and even the micro-climate of packaging rooms have all come from conversations rather than anonymous market statistics.
Radiopharmaceutical applications remain among the most demanding, since the compound often gets labeled with radioactive isotopes within minutes and injected into human subjects shortly thereafter. Here, even trace contamination disrupts the protocol. Over time, we’ve invested in metal-free glassware, high-efficiency particulate air filtration, and dedicated batch labeling for full traceability. Cheaper products cut corners, but returning customers value this attention to the points that don’t show up in standard lists—such as ease of dissolution, reproducibility batch after batch, and reliable supply chains.
Chemists know that DOTA and NOTA often show up in the same research articles, but side-by-side, their uses diverge. DOTA binds more tightly but takes longer to form complexes, which slows isotope labeling in short-lived radiopharmaceuticals. NOTA’s quicker binding times make it attractive in any setting where isotopes such as Gallium-68 must get chelated and injected without delay. Where cost or universal availability matter more, buyers go to EDTA or even cheaper multi-dentate acids. Those options often fail stringent radiochemical requirements, largely because they trap both wanted and unwanted ions and can’t deliver the no-background promise that NOTA brings.
As a regular feature in large-scale and custom runs, we often get involved in technical discussions about macrocyclic chelators. NOTA’s smaller ring size lowers the activation barrier for complex formation, especially under physiologic pH and salt conditions. This trait matters when end-users need to minimize unbound isotope loss—something our research partners highlight after trials and preliminary runs. In bioconjugation, where head-to-tail uniformity in labeled antibodies or peptides means better imaging contrast, NOTA’s predictable structure saves time and frustration.
Nobody wants a chelator that works well on paper but creates trouble in the lab. Among the practical lessons learned, we always point out three recurring pitfalls. First, contaminated glassware—especially trace metal residues—can reduce available coordination sites. Our lines only use freshly acid-cleaned equipment for critical syntheses. Second, storing open containers even briefly during processing invites atmospheric moisture, raising the water content and potentially hydrolyzing carboxyl groups. Our team runs periodic drills to review seal integrity and moisture-resistant procedures.
Third, we watch particle size distribution coming off the final filtration. Oversized crystals slow dissolution and can introduce heterogeneity in radiolabeling. By tweaking re-crystallization rates, we’ve reached a sweet spot—rapid dissolution under gentle agitation, without fine powder loss in handling. These details might sound minor, but over hundreds of runs and dozens of custom requirements, they add up to practical reliability that generic suppliers struggle to match.
While NOTA gets its most glowing reviews in the realm of nuclear medicine and biological labeling, interest keeps rising in areas such as environmental monitoring and advanced catalysis. Our contacts in academic labs report new metal complexes under study for antimicrobial activity or selective capture of heavy metal pollutants. These avenues open doors for NOTA beyond the classic label of medical research tool—something our technical liaisons increasingly support through smaller test batches or adjusted qualities aimed at emerging use cases.
Scale-up colleagues see similar stories in catalysis. Reliable chelation, predictable behavior in mixed-metal systems, and the ease of altering carboxyl arm positions allow screening of dozens of new metal complexes without lengthy pilot-scale starts. Researchers rely on a steady supply of chelator to test their ideas, and the certainty of reproducible, high-purity batches lets them focus on what matters: innovation. For us, preparing these specialty loads often means switching production lines or cleaning equipment to higher standards for just a few kilograms per campaign—a challenge we tackle with a sense of purpose and a long view on emerging technology needs.
Regulatory pressures continue to climb, especially for compounds with health and diagnostic applications. We keep detailed batch records, ensure validated cleaning and calibration protocols, and routinely train staff on cGMP and ISO practices—even for products not destined for direct diagnostic use. Certification is never a “set it and forget it” point, so we update records and undergo audits at regular intervals, bringing outside expertise for review and process improvement. Documentation packages head out with every shipment, including full traceability for source materials and processing steps. Our approach looks beyond compliance; customers often face downstream audits, and clean, accessible documentation saves them headaches and time.
From our admin desks to the last fine-filtration step, every member of the production team knows that quality starts with the first order of raw azacrown compounds. Sourcing from vetted suppliers and testing every incoming batch for heavy metals and organic contaminants minimizes rework hours later. Process engineers adjust the thermal profile and order of addition to keep batch yields consistently high, always documenting unexpected observations on the shop floor. At each drying and packaging point, small group huddles—part checklist review, part troubleshooting—catch problems before sealed packs leave the floor.
We handle field questions routinely: How do you scale up for multi-kilo loads while keeping water content below 0.5%? Which solvents leave the lowest residuals after drying? Did a minor pH drift affect the NMR fingerprint of a batch? Our teams rely on data, real-world experience, and lessons learned from hundreds of runs, favoring clear communication over boilerplate promises. We process feedback, adjust, and cycle insights back to R&D to feed tomorrow’s improvements in process and product.
Cost pressures come from every side. Larger players sometimes dump lower-quality chelators at prices we can’t match. Instead of racing to the bottom on price, we focus on long-term relationships and incremental product improvement. Customers taking the time to send chromatograms or bioassay results drive sharper process tweaks than any standard industry benchmark.
The next wave in chelation chemistry might bring new macrocyclic compounds with even more selectivity or better kinetic profiles. Manufacturers walk a tightrope between supporting current product lines and investing in R&D for the next best thing. Our technical groups meet with academic collaborators and attend scientific meetings to track these waves early, hoping to bring mature process chemistry to market faster than offshore generics. Along the way, we share real user feedback in cross-functional meetings, using data and end-user experience to fine-tune our priorities.
Pure chemicals can seem identical in photos or on spec sheets, but regulars know that subtle details separate a passable chelator from a dependable tool for mission-critical science. From our side of the plant fence, trust builds batch by batch. The effort put into reducing trace contaminants, maintaining airtight records, and answering late-night technical calls pays off in long-term customer partnerships and research outcomes that move science forward.
It’s not enough to meet the minimum. The community of radiochemists, peptide engineers, and environmental researchers depends on not just the molecule, but the knowledge, experience, and honesty poured into every cycle of manufacture. The way forward lies in hands-on experience, deep connection with end-users, and an unwavering focus on doing the hard work right, every single time a drum or vial leaves our loading dock.