HS Code |
879542 |
| Product Name | 1-Tridecene [Standard Material for GC] |
| Cas Number | 2432-78-4 |
| Molecular Formula | C13H26 |
| Molecular Weight | 182.35 g/mol |
| Synonyms | Tridec-1-ene |
| Appearance | Colorless liquid |
| Boiling Point | 234-238 °C |
| Density | 0.757 g/mL at 25 °C |
| Purity | Typically ≥99% |
| Refractive Index | n20/D 1.434 |
| Flash Point | 95 °C |
| Storage Temperature | Store at room temperature |
| Solubility | Insoluble in water |
| Smiles | CCCCCCCCCCC=CC |
| Application | Gas Chromatography (GC) Standard |
As an accredited 1-Tridecene [Standard Material for GC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 1-Tridecene [Standard Material for GC], 25 mL, supplied in an amber glass bottle with screw cap by Sigma Aldrich/Merck/TCI. |
| Shipping | Shipping of **1-Tridecene [Standard Material for GC] (Sigma Aldrich/Merck/TCI Chemical Grade)** involves packaging in sealed, chemical-resistant containers. Product is shipped according to safety regulations, such as UN and IATA guidelines for chemicals. Temperature-sensitive handling and labeling as a flammable liquid ensure safe, compliant delivery to laboratories or industrial facilities. |
| Storage | 1-Tridecene [Standard Material for GC] should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from direct sunlight, heat, and sources of ignition. Store separately from oxidizing agents and acids. Ensure proper labeling and use chemical-resistant shelving or cabinets. Follow all safety and regulatory guidelines provided by suppliers such as Sigma Aldrich, Merck, or TCI. |
Competitive 1-Tridecene [Standard Material for GC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Each batch of 1-Tridecene that comes off our reactor tells a story of deliberate process control and real commitment in our field. 1-Tridecene, C13H26, with CAS Number 2432-36-2, deserves an honest introduction, particularly for users who rely on authentic, reproducible results for gas chromatography (GC) analyses. The jargon and cut-and-paste phrases you often see online can't tell you what experienced chemists look for—consistency, purity, and a reliable boiling point are what make this compound a genuine standard in laboratories that depend on real-data precision.
Our focus, across countless cycles in production, has been systematic: minimizing batch-to-batch variation, controlling the isomer content meticulously, and keeping every gram safeguarded against trace impurities that throw off sensitive detectors. In GC applications, people talk about “standards” and “reference materials” as though they come from a black box, but most folks outside the plant don’t see the daily work it takes to guard purity above 99%. Special attention goes into keeping peroxide-forming contaminants and other common alkenes below detectable limits; we run in-process controls that keep these below thresholds specified by leading analytical laboratories. Our 1-Tridecene distills over a narrow range and meets strict retention time requirements, which sets it apart from general-purpose alkene grades or off-the-shelf products someone bottled down the supply chain.
If you ask five different technicians about the impact of 1-Tridecene purity on their GC runs, you'll get five stories, but the common thread is always clarity and reproducibility in their results. General commercial 1-Tridecene sometimes gives split peaks or background ghosting in GC-FID methods, especially if the manufacturer doesn’t take time with fractionation or post-synthesis scrubbing. It’s not just about getting to the 99%-plus baseline; we know that sulfur- and oxygen-based residues, even in the low ppm range, interfere with detectors, skewing quantitation and causing calibration headaches down the line. That isn’t an academic concern—it’s fieldwork borne from handling feedback from oil, chemical, and fragrance labs having to rerun samples for days due to invisible interferences no one caught upstream.
We don’t treat release certificates like some routine paperwork. Each batch log references instrument traceability back to NIST standards. Serial batch analysis, GC-MS purity snapshots, and archived retention indices are shared with every shipment for customer files, not just for the sake of regulatory paperwork but because years of producing for top-tier analytical labs taught us how quickly trust can unravel without a rock-solid audit trail. As both a manufacturer and (often) a fellow user, we maintain reserves from each lot for quality assurance, and we welcome technical inquiries regarding specific application requirements—whether for trace hydrocarbon quantification, performance benchmarking, or regulatory calibration. This level of transparency keeps both sides honest.
You may see a dozen sources online offering “1-Tridecene for GC” but as actual manufacturers who run the reactors, invest in fractionation columns, and shoulder the risk each time we scale up, we see the spectrum of what ends up downstream. Our standard material for GC doesn’t come from a repacker or a speculative importer; it’s the product of in-house synthesis and direct fractional distillation. We don’t take the easy road—others might rely on cracked olefins or mixed alpha-olefin streams skimmed from refinery by-products, but those sources often carry legacy impurities, secondary isomers, and color bodies that only come to light after the fact.
Lab techs sometimes call us after struggling with off-brand supplies that co-elute with branched C13 isomers or internal alkenes, especially when they’re trying to meet ISO/IEC 17025 or other high-stakes accreditations. Our own analytical team spent years optimizing our process to eliminate both high- and low-boiling cut-ins, ensuring peak symmetry in even the most demanding FID setups. Most generic-grade 1-Tridecene—sometimes labeled “for synthesis only”—fails the test for chromatographic clarity when compared side by side. Color and odor can give away oxidation or trace unwanted components, including non-alkene unsaturates or polar by-products.
This is why we sort our GC grade material using a standardized, multi-stage quality check that looks for not just bulk purity, but also absence of UV/VIS active entities, predictable vapor-phase profile, and stable mass fragmentation for detector calibration. For those who need more than a pure hydrocarbon—say, a reliable anchor for quantification runs or system suitability tests—these details become the difference between passing and failing an audit, especially in environments subject to government inspection or third-party validation.
From operator to operator, we’ve heard that lot storage and sample management can skew results as much as starting material quality. For this reason, we fill only in amber glass under inert atmosphere, and cap under dry nitrogen to prevent peroxide formation and keep the alkene stable over the stated shelf-life. Every chemist knows the pain of tracing an unpredictable baseline to oxidized standards weeks after delivery. Our filling protocols—born out of a few expensive lessons—focus on airtight packaging and tamper-resistant seals, to keep every ampoule or bottle as fresh as the day it left our facility.
Stability studies run side by side with real-world cycle testing: we store reference samples under forced-aging conditions and periodically test for new peaks by GC-MS and FTIR to catch even faint signals before they become a broader QC issue. Our team also checks packaging for any trace leaching from stoppers or septa, and records staff handling steps in a full chain-of-custody log, because clean-room mishaps in the final stages count for as much as synthesis steps. We work with a variety of vial and ampoule sizes, based on practical customer demand and the batch yield profile, aiming to allow the maximum number of users access to the same reference material for their own round-robin verification.
Knowing how GC detectors respond to our 1-Tridecene comes directly from our own experience shipping both internally and to critical partners. Over time, we noticed that different FID and MS detectors may amplify trace oxygenates or halides, even if they don’t pop in traditional purity checks. For this reason, every production cycle includes a split-sample validation using at least two separate GC systems and columns of varying stationary-phase polarity. Our own staff have run this material against both polar and non-polar GC columns, tracking retention times, broadening, and tailing factors, and accumulating a real-world performance record rather than relying solely on theoretical purity.
Callouts from partner labs showed us that commodity 1-Tridecene, especially from bulk petrochemical sources, sometimes lands in calibration sets for hydrocarbon environmental testing or food contact materials, only to give unpredictable detector drift or ghost peaks. Our GC standard material runs with span reproducibility and repeat peak heights, making it suitable for both internal and external quantitation protocols. Over the years, we've accumulated less than 0.1% complaint incidence over thousands of shipped bottles, attributable mostly to packaging mishaps in extreme environments rather than any core purity issue. In comparative proficiency tests, users report lower baseline noise, minimal interference, and zero secondary ghosting compared to standard-grade or off-brand material.
Field users put our material through its paces in petroleum labs, synthetic rubber facilities, and environmental contract organizations. Beyond the technical sheet, it’s the lengthy feedback from these sectors that guides our continuous improvement: a petroleum chemist once flagged a faint sulfur odor in a shipment, which kicked off a company-wide review of reactor seals. Another partner, running high-sensitivity P&T GC, uncovered a subtle retention drift tied back not to our product but to aging column liner equipment—proof that the stability of our material can often reveal laboratory weaknesses downstream before they turn into expensive analytical surprises.
Customers have documented performance against stringent QC programs. Whether calibrating for total hydrocarbon content, verifying environmental samples, or setting detection limits for regulatory clearance, they routinely see outcomes in line with what our in-house reference panels predicted. Over hundreds of documented tests, analysts rarely report instability or out-of-spec recovery rates, which lines up with the robust, repeatable synthesis and purification steps we built in for these environments. Instead of chasing spot fixes, our process refinements rely on regular customer check-ins and genuine process transparency. The partnership becomes more about enabling expert work in the lab rather than just pushing another bottle out the door.
Long years in manufacturing has taught us that compliance is more than matching a purity metric on a datasheet. Our GC-grade 1-Tridecene is manufactured in facilities running ISO 9001 and ISO 17034 quality systems; those controls extend from raw material vetting to full documentation on trace metals, allergenic residues, and residual solvents. Global regulatory shifts—such as new EU or US Environmental Protection Agency limits on hydrocarbon standards—directly influence our batch controls and reporting protocols. In regions pushing for increased transparency in chemical supply chains, we've worked ahead of the curve to implement digital release logs and automated certificate authentication. All of these measures exist not to pad an audit binder, but to safeguard every bottle from the kind of headaches that upend critical calibration runs.
It's worth stressing that real compliance, from our view, doesn’t just end at shipping; we field ongoing requests for post-delivery batch documentation, MSDS updates, and regulatory support, especially when standards move or analytical targets shift in environmental and petrochemical labs. There’s no shortcut here: we anticipate technical queries that span years beyond initial use, and we keep legacy batch files live for as long as downstream traceability might demand. Batch-level transparency isn’t just best practice—it’s an accountability promise built from years in the trenches.
Being the manufacturer, we don’t shy away from direct technical troubleshooting. Chemists and lab managers routinely reach out to trace minor deviations—unexpected detector responses, splitting, or baseline drift. Our team treats every call not as a liability, but an opportunity to troubleshoot, replicate, and strengthen the product lifecycle. If an anomaly turns up—be it a minor contaminant from handling, or a subtle off-peak visible only in ultra-high-sensitivity applications—we dig in, running re-tests, benchmarking against shipped reserve samples, and collaborating openly rather than retreating behind red tape.
Several customers requested bespoke solution concentrations or packaging variants to streamline their unique testing workflows. From these requests, we fine-tuned not just our delivery formats but also the supporting information, like dilution protocols and instrumental response overlays, so that every lab could adapt our material with minimal fuss or risk of miscalibration. Our technical team keeps a detailed log of such collaborations, feeding the data back to process improvement—not just for one-off batches but for the ongoing evolution of our standard.
No process runs in a vacuum. Our team has weathered production upsets: power outages during critical distillation steps, feedstock quality issues, and even learning the hard way about new detection limits driven by regulatory change. Each setback led us to scrutinize our formulation processes more deeply. Instead of masking minor blips or batch lag, we over-communicate to our users, flagging slight deviations proactively and offering full replacement if reproducibility is in doubt.
A few years back, residual impurities in a high-output run amplified a minor instrumental baseline in customers’ chromatography traces. Instead of soft-pedaling the problem, our team issued a voluntary recall and revalidated the material from the ground up. Such hard-learned lessons form the backbone of our current QA protocols; our customers rarely see this side of manufacturing, but these events drive why our GC-grade 1-Tridecene supplies come with such robust guarantees and process transparency. As users ourselves, we believe in facing up to flaws and using setbacks to build more resilient processes, not just chasing a higher spec on paper.
GC-grade 1-Tridecene production consumes resources and generates waste; as the entity at the source, we don’t ignore that reality. We have spent years refining catalyst systems, adjusting reflux ratios to improve yield-per-input, and investing in solvent recovery platforms. By keeping synthetic cycles lean, cutting energy spikes in fractionation, and reclaiming solvents, we reduce the chemical footprint of each batch. Starting a decade ago, we began integrating waste minimization into our root formula, not because of end-user pressure but because we deal directly with the residues—hazardous and otherwise—that don’t leave the plant.
Our shipments come in reusable, high-integrity packaging, and we invite customers to return reusable containers, which we sterilize and re-circulate after verifying no cross-contamination or legacy peaks. These upstream choices, driven by the day-to-day realities of chemical production, help ensure that sustainable practice isn’t just marketing talk, but remains a routine aspect of long haul manufacturing. It’s a loop of responsibility that starts at the reactor and never ends at the loading dock.
Technical innovation rarely comes from think tanks; it emerges from fieldwork, after long months or even years of user feedback on actual GC maintenance, troubleshooting, and round-robin calibration tests. As fellow chemists and process engineers, we rely on this loop: regular calls with users, on-the-ground QC feedback, spectral overlays, and critical reporting of both wins and failures. Each cycle of feedback turns into improved synthesis steps, better fraction collection, or faster flagging of emerging contaminants.
Recently, we ran a customer-wide pilot of new in-line filtration ahead of the final fill and saw measurable improvement in peroxide-forming contaminant suppression. All of this happens at the intersection of field experience and in-plant process R&D, instead of through impersonal, arm’s-length distributor recommendations. By remaining approachable, nimble, and unafraid to tackle detail-oriented user concerns, our manufacturing ethic allows us to maintain not just market access but genuine credibility.
Manufacturing 1-Tridecene of GC standard quality is not about hitting a single spec—it’s about listening to what real users encounter in the lab, owning our mistakes, and integrating solutions back into the plant. We built our process for transparent batch traceability, technical engagement, stability-focused filling, and compliance that meets or exceeds regulatory trends. Our hands-on approach, learned across thousands of collaborative interactions, makes the difference for users who depend on accurate, interference-free standards for calibration, quantitation, and error reporting.
That’s where the true distinction lies: with each bottle, we’re not just another actor in a crowded supply chain. We are the practitioners who see the consequences of our choices, from the first feedstock decision to the final instrument trace. The manufacturing commitment, the open-door approach to feedback, and the meticulous attention to every stage—those are the reasons our GC-grade 1-Tridecene continues to serve not just as a chemical, but as a trusted analytical tool for demanding labs worldwide.