HS Code |
695899 |
| Product Name | 1-Tetradecene [Standard Material for GC] |
| Chemical Formula | C14H28 |
| Molecular Weight | 196.37 g/mol |
| Cas Number | 1120-36-1 |
| Purity | Typically ≥98% |
| Appearance | Colorless liquid |
| Boiling Point | 253-255 °C |
| Density | 0.776 g/mL at 25 °C |
| Refractive Index | n20/D 1.440 |
| Flash Point | 116 °C (closed cup) |
| Storage Temperature | Room temperature |
| Solubility | Insoluble in water |
As an accredited 1-Tetradecene [Standard Material for GC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for 1-Tetradecene [Standard Material for GC] (Sigma Aldrich, 25 mL) features an amber glass bottle with a secure screw cap. |
| Shipping | The chemical **1-Tetradecene [Standard Material for GC]** is shipped in tightly sealed containers to prevent contamination and evaporation. It is packaged according to regulatory standards for hazardous materials, with clear labeling and safety documentation from suppliers such as Sigma Aldrich, Merck, or TCI. Temperature and handling precautions are strictly followed. |
| Storage | 1-Tetradecene [Standard Material for GC] should be stored in a tightly sealed container, away from incompatible substances, sources of ignition, and direct sunlight. Store at room temperature in a cool, dry, and well-ventilated area. Avoid moisture and excessive heat. Ensure chemical is clearly labeled and separated from acids, oxidizing agents, and strong bases to prevent hazardous reactions. |
Competitive 1-Tetradecene [Standard Material for GC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our facilities, we strive to set new standards for traceability and purity in the field of standard reference materials. Delivering 1-Tetradecene as a standard material for gas chromatography (GC) comes from understanding how a single hydrocarbon can impact analytical accuracy throughout the chemical industry. Many years of producing organic chemicals at this scale have shown that the demands of gas chromatography go beyond the minimums set on certificates of analysis. Every batch must answer for its consistency, trace impurities, and handling procedures because, in practice, small variances propagate major errors downstream.
Many users of GC reference materials talk about “purity” and “stability,” but with 1-Tetradecene, what sets a manufacturer apart is the discipline to keep those words meaningful batch after batch. Cross-contamination and micro-impurities in a reference are not just theoretical risks—they show up as extra peaks, drifting quantification, and wasted hours of troubleshooting. Only an in-house process from raw material to final ampule can answer for all those variables. Our 1-Tetradecene is distilled in rigorously controlled conditions, removing sulfur species, aldehydes, or trace paraffins that otherwise hide in ordinary commercial grades.
Our team’s experience has taught us that standards aren’t just “checked in” after purchase, but must be “proven” daily right up until use. Shelf life, seal integrity, and packaging all matter. Storing the material under argon and flame-sealing the vials prevent oxidation and limit volatilization. Many reference standards drift not because of initial production gaps, but from evaporation or atmospheric contamination during storage and repeated sampling. Years of feedback and controlled storage trials have led us to design packaging that keeps our 1-Tetradecene reliable even across long hauls and slow laboratory turnarounds.
This is not an accident. Standards for GC analysis are intended to serve as absolute baselines. If an analyst suspects the standard’s quality, every subsequent result faces doubt. By owning the entire chain—sourcing, distilling, handling, and packaging—we remove intermediate sources of error. This way, 1-Tetradecene not only matches published purity values but actually arrives at the bench in a condition worthy of calibration work.
Our 1-Tetradecene for GC use embodies a single, well-defined molecular structure. We typically offer the linear alpha-olefin with the molecular formula C14H28 and a chain length that ensures a boiling point bracketed for mid-range volatility in GC protocols. The product appears as a colorless, clear liquid in standard atmospheric conditions.
Purity as measured by capillary GC methods typically exceeds 99%, with total impurities lower than 0.5%, and water content remains below detectable levels using Karl Fischer titration, not only at production but at the time of packaging. We have seen through routine customer audits that these specifications protect against false positives and ghost peaks in GC-FID or GC-MS analysis.
The standard quantity per unit is most often 1 mL and 5 mL vials, flame-sealed after filling to eliminate air ingress and sealed inside inert gas bags for additional protection during storage and transport. We have watched many labs lose time and data precision from standards supplied in plastic or less robust containers that allow for chemical interaction or vapor loss. By sticking to lab-grade borosilicate ampules and strictly monitored fill lines, we answer for the long-term stability that QC and method validation require.
From direct experience, there is an important physical behavior to note. 1-Tetradecene, being a higher-molecular-weight alpha-olefin, retains enough volatility at moderate GC injector temperatures to give sharp, reproducible peaks, but does not foul or react with glass wool or common injector linings, even after extended use. This matters in multi-run labs handling a wide slate of standards, where contamination and breakdown products from lower grades routinely introduce headaches. For the user, less background equals more confidence in quantitation and lower blank values.
Working closely with reference labs, we understand the daily demands tied to a single vial of 1-Tetradecene. Calibration becomes the focus, not just identification. Petrochemical plants, environmental testing labs, and specialty chemical refineries need standards to check instrument linearity, detector response factors, and help validate methods for hydrocarbon fingerprints. These real tasks drive every spec and handling protocol we set.
For many, the distinction between high-purity reagents and genuine GC standards is only recognized when an audit occurs or a validation fails. Commercial 1-Tetradecene grades—made for polymerization feedstock or bulk detergents—bring trace peroxides, branching, and stabilizer residues. In our workflow, we test every outgoing batch for baseline drift and background interference using both FID and mass spectrometry, uncovering contaminants not listed on basic certificates. These details only surface through long-term real-world use.
We have also responded to labs facing regulatory scrutiny, where “just pure enough” isn't enough. National reference labs, oil blending facilities, and even academic research cores need a reliable retention time marker that will not decay between shipments or show breakdown after one run. This requires more than typical grade and purity specs. It demands a willingness to ship smaller but fresher consignments, share detailed analytical data on request, and stand behind each certificate with traceable internal calibrations.
Research teams, especially those testing new GC columns or performing detailed hydrocarbon characterizations, use our material as a way to benchmark instrument performance before tackling real-world samples. This baseline clarity, free from extra noise, gives the confidence to interpret unusual data as signal, not artifact. In high-throughput gas chromatographs, consistency in peak elution time and shape lets users automate more, spend less time calibrating, and avoid repeating runs.
Mixing up high-purity commercial products with properly assigned reference materials might seem minor on paper, but it leads to multiplied problems downstream. Our team has seen customers struggle with inconsistent response factors, wandering retention times, or unexplained peaks, only to trace these issues back to subtle formulation gaps in other so-called “pure” tetradecenes. Proper reference standards require more than high initial assay—they demand reliable inertness, correct identity, and the absence of stabilizers or oxidation byproducts found in technical grades.
Other sources may supply 1-Tetradecene stabilized to prevent polymerization during shipment or storage for industrial use. Those additives change the chemical profile, leading to extra responses on FID and interfering masses on MSD, particularly in sensitive environmental or flavor analysis methods. Our users’ methods are sensitive enough to pick up these traces, sometimes even from ampule walls or packaging films. Every point of contact, from distillation glassware to filling machinery, gets checked, cleaned, and tested so that our material can serve as a “true zero”—not an approximation.
Shelf life has also emerged as a major point in our discussions with advanced users. Even among high-purity grades, longer storage can allow trace oxidative or polymeric impurities to build up, particularly if packaging isn’t truly airtight. Our process sets the fill line to no more than a two-week delay between final purification and ampule sealing, guaranteeing a fresh starting point every time. It’s not only a matter of specification, but a practice proven by customers who regularly return to match archived chromatograms with retained reference samples, even after a year or longer.
Where others settle for standard commercial packaging, we have moved to specialized ampules—thicker than typical—to handle accidental drops or repeated flame-sealing in busy labs. Our decision comes from real user feedback after seeing breakage or slow vapor losses degrade results. Even the solvent-free fill and argon blanketing respond to conversations with scientists who worry about unwanted dissolution or surface catalysis affecting trace measurements.
Placing “1-Tetradecene [Standard Material for GC]” at the center of precision analytical work means more than high purity on a label. Years hearing from QC chemists and instrument technicians shape every batch. Repeat customers—often those running ISO 17025 or similar accredited labs—have taught us to implement batch-specific, data-rich certificates, full spectroscopic data, and original chromatograms for every shipment.
Access to such detailed backing makes a difference in high-stakes settings, such as legal dispute labs or round-robin method validation studies. Analytical chemists trust only those materials that come with assurance, not only through numbers but through a manufacturer’s willingness to explain methods, show their own internal controls, and address questions quickly and transparently. We have sat in audit meetings where the only way a disputed result could be traced and resolved lay in our detailed batch records and years of manufacturing logs. A trader or distributor could never answer for those details.
Every upgrade in our process—from fresh distillation runs to new packaging lines—comes as a real answer to complaints or requests from the field, not from abstract “quality systems” or marketing claims. For example, specialty contract labs needing trace olefin markers for fuel blending studies drove us to batch-test for trace halides and alkynes. This is not an afterthought, but an embedded part of reference production. We stand by the results, not only because the certificate says so, but because our own routine in-house calibration depends on the same product.
The needs of modern analytical labs rarely stay static from year to year. Regulatory reporting limits get tighter, internal QC cycles grow in complexity, and clients demand faster turnaround on complex blends. Our conversations with working lab managers show that every step counts, from opening a new ampule correctly to verifying the stability of the standard mid-study.
Several users report that standard ampules shipped from resellers or bulk suppliers too often arrive with compromised seals, mismatched volumes, or superficial specification sheets. We address these issues by filling, weighing, and sealing each unit under a validated process, preserving headspace gas purity and checking for leaks by hand. This isn’t about efficiency metrics; it’s about guaranteeing the product delivers not only the expected composition, but all the functional integrity needed for repeat research and reporting.
Our supply chain traces directly to the source. We understand that chemical traceability means little if containers and internal documentation break the chain. That is why every ampule retains production date coding, batch internal IDs, and a matching analytical packet direct from the original batch—no substitutions, no relabels, and no partial fills. GC operators trust this workflow because verification and repeat use both rely on the reliability of every procedural detail.
We see our role not simply as a supplier, but as an extension of the laboratory’s own best practices. If instability, contamination, or ambiguity about material identity can derail a lengthy validation or external regulatory check, a manufacturer has the responsibility to solve these problems upstream. Every time we invest in more advanced headspace purging, closer fill tolerances, or denser glass ampules, it is because labs across petrochemical, environmental, and food analysis sectors report tangible gains—fewer failed runs, less recalibration effort, clearer separation between noise and true analyte.
By committing to a direct-from-manufacturer model, we put our experience in customer service, chemical engineering, and real-world analytical troubleshooting behind every ampule of 1-Tetradecene for GC. Our users don’t worry about middlemen introducing mishandling or unannounced repackaging. Every product reflects our practical belief in over-delivering on reproducibility, even when that means slower releases, tighter shelf lives, or added in-house checks.
Comparing our 1-Tetradecene to bulk or commodity grades isn’t about marketing claims—it’s about flagging the challenges that show up in audit trails, routine analyst troubleshooting, and instrument downtime logs. From fielding customer calls on retention time shifts to hearing about cross-vial contamination events, our learning continually tightens both our specs and daily operations. No batch passes unchecked or unverified with current best-in-class analytical tools—because the stakes in reference standards, unlike mere reagents, touch every result downstream.
Real-world issues like ampule breakage, solvent traces, or labeling ambiguity don’t surface in abstract product datasheets, but in messy, real laboratory settings. Our hands-on experience helps us spot and eliminate those pain points as soon as they appear. Product innovation won’t move fast enough without using feedback from people running critical methods in environmental, petrochemical, or regulatory labs. That engagement closes the loop between pure industry knowhow and reliable laboratory results.
Standing behind our 1-Tetradecene [Standard Material for GC] is not about how a product looks on a benchmark chart, but about delivering trust, reproducibility, and clear answers to the analyst’s most detailed calibration needs. When genuine consistency counts—over months, between audits, and across critical workflows—we put manufacturing experience into motion, answering both the technical and practical tests that define successful modern chemical analysis.