West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

1-Pentadecene [Standard Material for GC]

    • Product Name 1-Pentadecene [Standard Material for GC]
    • Alias 1-Pentadecene
    • Einecs 214-300-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    438971

    Product Name 1-Pentadecene
    Cas Number 629-62-9
    Molecular Formula C15H30
    Molecular Weight 210.40
    Purity Typically ≥97%
    Physical State Liquid
    Boiling Point 267-268°C
    Density 0.776 g/mL at 25°C
    Refractive Index n20/D 1.440
    Flash Point 107°C
    Appearance Clear colorless liquid
    Solubility Insoluble in water
    Storage Temperature Room temperature
    Synonyms Pentadecene-1
    Ec Number 211-096-7

    As an accredited 1-Pentadecene [Standard Material for GC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 1-Pentadecene [Standard Material for GC] is packaged in a 25 mL amber glass bottle, sealed for purity by Sigma Aldrich.
    Shipping 1-Pentadecene [Standard Material for GC] is shipped in tightly sealed containers, compliant with chemical safety regulations. Packaging ensures protection from moisture and contamination, and includes appropriate hazard labeling. Handling and transport follow international guidelines for flammable liquids. Temperature and storage recommendations are maintained to preserve product integrity during transit.
    Storage 1-Pentadecene [Standard Material for GC] should be stored in a tightly closed container in a cool, dry, and well-ventilated area, away from sources of ignition and incompatible materials such as strong oxidizers. Keep it out of direct sunlight. For best results, store at ambient temperature as specified by Sigma Aldrich/Merck/TCI guidelines, ensuring proper chemical labeling and inventory management.
    Free Quote

    Competitive 1-Pentadecene [Standard Material for GC] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    1-Pentadecene [Standard Material for GC]

    Experience from the Source: A Closer Look at 1-Pentadecene

    Producing 1-Pentadecene for gas chromatography means shaping a material to support the work of analytical chemists who demand clarity, reproducibility, and a known reference point in their workflows. As a manufacturer, we've spent years refining each stage of production—starting with high-purity feedstock, optimizing purification process controls, and ensuring the absence of interfering contaminants.

    We understand what’s riding on every ampule. End-users depend on the reliability of our standard material when developing calibration curves or validating GC instrument performance. The minute variations in carbon chain impurities that might go unnoticed on a bulk chemical plant scale are simply not tolerable for standard material. Our team continually monitors trace hydrocarbons, moisture, and other organic or inorganic components to keep the 1-Pentadecene’s signal well defined and free from confusing noise in chromatograms.

    Specifications and the Real Meaning of Purity

    Years of producing alkene standards taught us that “above 99% purity” means different things to different users. For routine calibration in research or process labs, a little carry-over from saturated hydrocarbons can dramatically shift retention times and compromise the credibility of results. The methods we’ve put in place address more than percentage numbers—they target GC response, minimizing ghosts in the baseline and minimizing overlapping peaks, especially with closely related alkenes or residual solvents.

    The technical specifications we deliver for this material include tightly defined isomer content, clear limits on total residue, and controlled storage that preserves its integrity from our loading line to your workspace. Each lot comes from a process designed to minimize batch variation, because our teams see firsthand how analysts struggle when standards fluctuate from shipment to shipment.

    Purpose-built for Gas Chromatography

    There’s a wide range of pentadecene grades in the market, many sold as intermediates for synthesis or as lubricant additives. Our 1-Pentadecene, offered as a standard material for GC, is distinguished by its preparation method. It’s fractionally distilled under nitrogen to control atmospheric exposure and packaged in amber vials that reduce light-driven degradation. Routine analyses track peak shape for both the compound and common impurities so users know what expect straight out of the vial.

    We chose this approach to reduce the need for cumbersome internal pre-treatment. Labs can use the product for calibrations as received, without costly re-confirmation or pre-run distillation. Reducing bench preparation time directly supports higher throughput for contract testing labs, chemical quality-control centers, and third-party calibration providers. This approach also reduces the risk of error during time-pressured sample prep, which is common in busy environments.

    What Sets Our 1-Pentadecene Apart: A Manufacturer’s Perspective

    Producing 1-Pentadecene to the highest standard isn’t about checking regulatory boxes—it’s about anticipating the real scenarios our customers face. The GC specialist often tests new instrument configurations. Students and early-career chemists depend on reliable reference points to build their skills. Research teams look for reproducible data as they develop new detection methodologies. We’ve structured our process in response to consistent requests from these users.

    Other pentadecene materials sometimes contain branched isomers, unreacted olefins, or lingering catalyst residues from less rigorous productions. We designed our process to avoid these pitfalls. Long-chain alkene standards like this one can easily pick up peroxides or acids if left open to air, so our vials offer an oxygen-barrier seal and our packaging area incorporates trace oxygen scrubbing.

    A detail not every supplier will mention: trace metal contamination often disrupts detector stability, especially for sensitive detectors like FID or MS. Our equipment, transfer lines, and filling stations consist of inert materials, minimizing the risk of leaching. Each batch is certified by our laboratory staff, so it meets internal criteria before it becomes a shipped product.

    Practical Applications Beyond Calibration

    Labs using our 1-Pentadecene routinely report no significant baseline drift or post-injection ghost peaks. This reliability enables better method development, especially in QA/QC labs in petrochemical, environmental, and pharmaceutical sectors.

    For example, environmental monitoring groups rely on precise chain identification for pollutants and organic residues. A poor-quality alkene standard can result in overlapping signals, misidentification of environmental contaminants, or missed regulatory targets. Contract testing services, facing frequent sample changeover and limited downtime, require standards that deliver repeatable results with little prep.

    Pharmaceutical and flavors and fragrance developers also frequently turn to this product. Unintended residues, even at very low concentrations, ruin instrument stability and cause unwanted signals in trace-level impurity screening. The stringent purification and stability controls in our material support reproducible quantitation, even across multiple calibration sessions.

    Supporting High-Resolution Research

    Research institutions studying hydrocarbon transformations or investigating new chromatographic phases need more than an impure bulk sample. They look for clear reference materials for use with modern columns, advanced mass spectrometers, and high-sensitivity detectors. Our focus on chain fidelity and isomer separation empowers researchers to push the boundaries of separation science and method detection limits.

    Some users have explored emerging applications—like the development of novel stationary phases or two-dimensional GC setups—where background contamination or extra peaks obscure the true performance of their new technologies. In these cases, the clarity and reproducibility of our standard have often enabled users to trust their calibrations and spot actual performance improvements.

    Addressing Troubles and Pushing Quality Further

    Supplying a stable, high-purity 1-Pentadecene isn’t a one-time effort—it’s a process that we continually strengthen. Over the years, we’ve fielded feedback from customers who noticed subtle shifts in response factors between batches or experienced unexpected degradation in storage. Our team took these reports seriously, launched a root-cause investigation, and improved both our inert gas transfer systems and the materials used for crimp septa.

    Shipping and storage present persistent challenges for long-chain alkenes. Even short exposures to heat, light, or air sometimes result in oxidation or polymerization. We’ve partnered with trusted logistics providers and set up temperature- and humidity-controlled conditions to get around these issues. Shippers receive explicit instructions supporting the handling requirements for all high-purity alkene standards leaving our facility.

    Responding to reports of sample decomposition over long storage, we initiated a program where stability assessments run alongside regular quality release testing. The performance data guide our packaging and shelf-life recommendations. Where competing products might suggest “store below room temperature” as a catch-all, we offer batch-specific advice, clearly outlined with each shipment. This comes from tracking actual material behavior, not just regulatory minimums.

    Comparing with Other Alkene Standards

    1-Pentadecene shares features with other long-chain terminal alkenes, but manufacturing experience tells another story. The volatility, reactivity, and ease-of-handling differ significantly between materials like 1-decene, 1-dodecene, or heavier homologues, especially when considering how they interact with common GC and GC-MS detectors.

    When producing 1-decene, high volatility often complicates packaging and shipment, requiring alternative vialing technology. The lower boiling points increase loss risk if not managed precisely. With 1-octadecene or higher, viscosity steps in as a challenge, so filling instrumentation needs adjustments. Our focus on 1-Pentadecene bridges the gap. Handling challenges fall to a manageable level, and operator training can stay minimal.

    Some vendors aggregate production of multiple alkene grades, risking cross-contamination, or use coarser distillation fractions to fill standard vials—meaning that both lighter and heavier chain lengths sometimes leak into the final product. Our facility dedicates separate purification streams for each GC standard, so batch-to-batch variability, and cross-alkene bleed, are tightly controlled.

    Where off-the-shelf non-GC grades contain up to five percent related substances (branched or cyclic forms, residual catalysts), our standard for GC restricts these, preserving response reliability over many cycles. That’s something laboratory professionals value when troubleshooting unexplained chromatographic artifacts—real-world feedback confirms that confidence in the reference peak streamlines both calibration and longer-term instrument evaluation.

    Quality Guarantee Rooted in Real Manufacturing

    We don’t rely solely on instrument data or third-party certifications. Our plant engineers spend time on the bottling line. Our analytical chemists run checks on both fresh and aged vials. Field service reps visit top customers, listening to the small complaints as well as the bigger technical issues. Product managers track not just purity but user experience, making direct calls to collect long-term feedback on usability, signal clarity, and post-run instrument conditions.

    A continuous feedback loop from production to application connects every step of our process. Our attention to analytical performance is not only about purity figures—our standards must consistently match the chromatographic behavior expected by experts working in QA/QC, research, or troubleshooting roles. This connection between the manufacturer and the end user sets the product apart from generic or repackaged standard offerings.

    Each release undergoes independent validation. We maintain records correlating customer results with in-house analysis, supporting repeat purchase decisions and method reproducibility. This approach reduces uncertainty, time wasted revalidating each new lot, and costs associated with troubleshooting poor standards.

    Environmental and Safety Considerations

    Working with 1-Pentadecene demands a strong safety culture at every step, especially for GC-grade material. Our plant maintains dedicated storage for raw monomers, with controlled temperature and vapor containment to avoid accidental exposure. Filling lines use safeguard measures to prevent leaks, and we run staff training on spill management and chemical exposure—both routine and emergency scenarios.

    While some producers downplay safety factors, we integrate them into every stage from planning to shipment. We also respond to calls from labs navigating new regulatory requirements on chemical handling and waste minimization. For greener labs, the lower residue and process-optimized packaging make disposal easier and less hazardous—a frequent talking point for clients undergoing routine environmental audits.

    Our track record shows that a high-quality standard can reduce not just direct chemical costs but also time and resource expenditures in waste management, equipment maintenance, and compliance audits.

    Long-Term Investment in Technical Support

    Manufacturing chemical standards never stands still. Over time, we’ve identified both gaps and emerging requirements through global partnerships with major research hubs. Feedback from academia, government reference labs, and private industry drives our ongoing process improvements.

    We regularly update our purification and packaging procedures in response to shifting analytical technologies. For example, as more labs employ high-sensitivity detectors and low-bleed columns, our own QA has extended to ultra-trace measurements of potential contaminants. We track the changing needs of the GC community, measuring our results not against abstract benchmarks but against the daily expectations of chemists and lab supervisors.

    Recently, some customers have requested support for hybrid calibration standard mixes, incorporating 1-Pentadecene into broader alkene panels for multi-component analyses. Our teams have worked closely with these labs, providing application notes and sample blends prepared under the same rigorous standards as our pure materials.

    Technical support doesn’t end at the loading dock. We offer ongoing access to our scientific staff, troubleshooting guides, and user-tested protocols for every product shipment. Our aim is to keep users focused on their analysis, not distracted by problems with the reference materials. This close user partnership formed the backbone of our unique value as a manufacturer, not just a supplier.

    Listening to the Needs of Analytical Laboratories

    Analytical challenges rarely surface in isolation. When an instrument baseline drifts, a peak emerges unexpectedly, or response factors shift, labs need a partner that listens. Over the years, we have built direct feedback into our supply chain. Customers frequently relay performance data, request technical advice, and sometimes challenge us to improve further.

    This two-way communication is built into the culture of our plant. We learn from each issue, whether raised by a doctoral student tuning a new GC method or by an industrial lab running thousands of samples weekly. Instead of one-size-fits-all solutions, we explore targeted machinery upgrades, new cleaning techniques, and refined process management.

    Some of our long-term customers shared accounts of switching from more generic standard sources. They found that seemingly minor batch differences or ambiguous certification records cost them time and introduced uncertainty. Through attention to real-world laboratory requirements, our product offers dependability and clarity—not just on paper, but in the actual day-to-day operation of busy chromatographic labs.

    Supporting the Pursuit of Scientific Excellence

    Every ampule of 1-Pentadecene for GC produced here is the product of accumulated skill, rigor, and shared experience. Our team understands that analytical science advances on the strength of credible, traceable benchmarks—some of that responsibility lands squarely with the provider of standard materials.

    For research projects growing in complexity or businesses relying on quick sample turnaround, the right standard helps teams reach their goals with fewer delays. By delivering reliable chain-length control, practical packaging, and a support network that bridges the gap between producer and user, we help analysts focus more on discovery and innovation.

    As technology moves forward, the demands on calibration standards continue to grow. With 1-Pentadecene, our manufacturing team takes pride in matching those needs—rooted in experience, driven by evidence, and built on a lasting partnership with the scientific community.