West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

1-Butanol [for HPLC Solvent]

    • Product Name 1-Butanol [for HPLC Solvent]
    • Alias Butyl alcohol
    • Einecs 200-751-6
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    522669

    Chemicalname 1-Butanol
    Casnumber 71-36-3
    Molecularformula C4H10O
    Molecularweight 74.12 g/mol
    Appearance Clear, colorless liquid
    Purity ≥99.5% (typically for HPLC)
    Boilingpoint 117.7°C
    Meltingpoint -89.8°C
    Density 0.809 g/mL at 20°C
    Refractiveindex 1.399 at 20°C
    Flashpoint 35°C (closed cup)
    Solubilityinwater 73 g/L at 25°C

    As an accredited 1-Butanol [for HPLC Solvent] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing 1-Butanol [for HPLC Solvent] (Sigma Aldrich/Merck/TCI) is supplied in a 1-liter amber glass bottle with safety sealing.
    Shipping Shipping of **1-Butanol [for HPLC Solvent] (Sigma Aldrich/Merck/TCI Chemical Grade)** follows strict safety regulations. The product is securely packaged in leak-proof, chemical-resistant containers, labeled per hazardous materials guidelines, and typically shipped via ground or air transport with appropriate documentation and temperature control to ensure product integrity and user safety.
    Storage 1-Butanol [for HPLC Solvent] should be stored in a tightly closed container in a cool, well-ventilated, and dry area, away from heat sources, ignition points, and incompatible substances such as oxidizers. Protect from direct sunlight and moisture. Ensure proper labeling and store at room temperature, following the supplier’s safety data sheet. Use appropriate chemical storage cabinets if available.
    Free Quote

    Competitive 1-Butanol [for HPLC Solvent] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Reliable HPLC Analysis Starts with Dedicated 1-Butanol

    Focused Manufacturing Meets Analytical Precision

    Years of chemical processing have shown just how much the smallest impurity can skew analytical results. Laboratories demand solvents with specifics not just in purity, but in how consistently that purity remains across batches. 1-Butanol for HPLC solvent applications stands as a direct result of these practical experiences. Manufacturing for chromatographic analysis works differently than for general-purpose grades: the systems, the culture, and even the way technicians approach line changeovers keep cross-contamination at bay.

    This HPLC-grade 1-Butanol emerges from a tightly managed distillation line, set to minimize secondary alcohols or aldehydes. Each run pulls data on water content and residue, with continuous checks on UV absorbance thresholds that match the demands of liquid chromatography. In our process, the most critical quality controls revolve around those invisible factors—minute trace metals, peroxides, or byproducts that linger in commodities built for industrial use. There’s no hiding those flaws from sensitive detectors. Only by sticking close to the equipment, constantly running blanks and controls, does a producer see how quickly luck runs out from just a little slip in method or a rushed cleanup.

    True HPLC-Grade Requires More than a Standard Purity Badge

    Some confuse technical grade for HPLC solvent, but these categories differ far beyond the label. Technical grade 1-Butanol often comes in from multipurpose facilities, focused on yield and throughput for coatings, plastics, or fuel blends. Sampling from these lots reveals batch-to-batch swings—even purified, trace organic and inorganic residues commonly slip through. For HPLC, even a tiny fluorescent impurity can ripple through a baseline, masking or mimicking a signal you want traced back to the original analyte.

    Direct control over the synthetic route—and then the grinding discipline in distillation, dehydration, and bottling—lets the differences stand clear. A manufacturer investing in HPLC lines doesn’t just monitor the usual suspects like water or acid number; extra attention goes into spectroscopic scans, especially at lower wavelengths, to ensure no ghost peaks haunt blanks or reference runs. It stops those long troubleshooting headaches where a mystery background absorbs at 210 nm or leaches ions into buffers.

    Spec-Driven Production, Fewer Troubleshooting Surprises

    Every bottling session for this solvent line starts with instrument-based validation—not a paperwork exercise, but hands-on, running dummy chromatograms and spike recovery tests. The quality crew know that one missed piece of wash tubing, or even a subtle kink in the stillhead packing, shows up in unexpected UV noise. The target purity, running well above 99.8%, alone doesn’t capture this level of attention—chromatographers look for a blank baseline, not just a big percentage on a certificate.

    From our vantage point, a close relationship between production chemists and analytical scientists makes all the difference. Many times, it’s a phone call from a lab facing a streaky baseline or a new artifact in their reference blanks that sends the team back to a root cause. Whether it's an unusual storage drum leaching plasticizers or humidity creeping into the drying step, these discoveries feed back into process improvement. Those shifts in protocol often feel minor, but the outcome—bottles that offer the same performance run after run—keeps customers from chasing ghost peaks.

    Practical Value in HPLC Applications

    1-Butanol holds a unique spot in HPLC applications, especially in phase separation protocols, extraction methods, and as a component of complex mobile phase blends. The polar, yet hydrophobic nature of the molecule lets analysts target medium-range analytes that either break off too early or elute with too much tailing in simple methanol or acetonitrile systems. In hands-on sample prep, butanol becomes a workhorse for partitioning, assisting in protocols where less polar solvents can’t tease out those tricky semi-polar compounds or disrupt protein-ligand complexes during biomolecular studies.

    From a manufacturing perspective, these uses tie directly to storage and handling practices. Water picks up fast in alcohols, and over the years we've moved from standard drums to lined vessels, plus inert gas overlays in bulk storage. Experience flagged the quickest culprit: a pinhole in a storage vessel or a lazy vent valve lets ambient moisture ramp up water content, killing performance. A tiny water shift can crash analyte solubility or weaken the precision of complex gradient runs. So, our batch release checks reach further—with Karl Fischer titrations run on every lot and low-conductivity seals standardized across the line.

    Model, Specifications, and Focused Performance

    By controlling synthesis from the start, the resulting HPLC line of 1-Butanol leaves little to chance. Typical output features purity over 99.8% and passes absorbance filters below 0.01 AU at standard UV testing wavelengths including 254 nm and 280 nm. Each package comes with a traceable batch certificate from the manufacturing floor—tracked from tank fill to cleaning cycle, to filling in climate-controlled rooms under HEPA filtration.

    Specifically, this grade is engineered for the kind of labs that care about signal-to-noise ratios as much as about the solvent’s role in extractions or dilutions. The small details like leachable-free liners, hazard-labeling for sample room use, and lot-based retention samples deliver ready answers when troubleshooting. These systems grow out of direct experience: early on, a customer called with persistent ghosting in their blank traces. A few hours on the plant floor found out one lot of glass had a siliconizer left over from a supplier switch. That’s the level of check that sticks.

    Why Analytical Labs Notice the Difference

    Labs running HPLC look for solvents that won’t raise any doubts. Poorly controlled 1-Butanol blends drag along traces of organic acids, not only causing baseline drift but slowly corroding the stainless internals of high-cost instruments. One batch that’s off by just a few ppm of unknowns can force a lab to rerun weeks of standards and calibration curves. Given how many runs today handle metabolites, trace pharmaceuticals, or even food residues meant for regulatory records, a reliable, predictable supply matters far more than high-volume options found on commodity chemical websites.

    The constant focus on separating the production lines for this grade pays off. Production switchovers become a routine audit point—no short-cuts, no last-minute substitutions. Line flushing and vapor phase cleaning break the back of cross-contamination, a protocol that has gotten more meticulous with every customer complaint teaching something new. Producers have learned, sometimes painfully, that solvents treated as bulk goods in one facility can never reliably serve analytical applications—unless every step holds to a stricter regimen.

    From Production Floor to Lab Bench—What Actually Matters

    Working as both the manufacturer and a supply partner, we see trends—many labs push toward automation in sample prep and large-volume runs. In those settings, each anomaly multiplies. Automated samplers don’t forgive background spikes in baseline; once a ghost peak emerges, it’ll keep appearing, eating up precious time just deciphering its source. Our team took to creating solvent libraries of blank runs at both 0.1% and 1% levels, letting new customers directly compare to their own methods. This helps clear up whether a signal comes from the sample, the instrument, or something unwanted in the solvent—an insight that started with our own production analysts.

    Lean years in the chemical trade shaped how we approach tightened budgets in labs, too. Spending moves from “just any” solvent to products that won’t waste thousands in analyst hours re-validating after a bad batch. The phone calls and emails we’ve fielded cover every imaginable troubleshooting scenario—a little yellowing in a cap liner, a drum stored under harsh warehouse LED lighting, even a triple rinse not quite removing a stubborn ester from a shared line. These lessons feed upgrades: now we run multi-tiered inspections and rapid-response deviations, informed by the headaches we’ve helped resolve.

    Logistics play a part. A shipping delay starts a chain of risks—condensation builds up, seal integrity falters, and transit heat can nudge unstable byproducts into the solvent. For HPLC customers, shipment in small lots or temperature-controlled vehicles isn’t luxury—it’s the insurance needed for method reproducibility. Protecting product during peak summer or through port slow-downs isn’t just about avoiding loss; it’s about keeping that blank baseline just as it should be, no matter the season.

    Difference from Bulk or Technical Grades

    Having manufactured both commodity and HPLC-grade 1-Butanol, these distinctions aren’t trivial. Technical grades serve enormous demand in adhesives and specialty plastics, where minor residues don’t affect performance. Analytical applications use the same molecule, but demand a much higher level of trust—not just between the customer and the certificate, but from the line chemist to the QC desk. Skipping just one verification run means risking a batch that throws off an entire analysis campaign.

    Facilities making both grades operate entirely separately. The butanol for analytical testing avoids shared lines that run glycols, fuels, or other alcohols. Dedicated filtration and material transfer—built off learning what traces hide where—define each batch. Routine third-party audits challenge teams on everything from equipment drain points to atmospheric controls. Many changes here emerge after a single batch fails a customer spike test, reinforcing a culture of improvement. These day-in, day-out lessons filter down into every key checkpoint—because we’ve seen how even a stray packaging tape can add an unwanted chemical note.

    Supporting Precision in Research and Regulatory Tasks

    Across clinical research, environmental testing, and pharmaceutical labs, solvent integrity forms the foundation for defensible results. 1-Butanol, though less common than acetonitrile or methanol, fills a necessary role where matrix effects challenge other solvents or where co-elution creates headaches. We’ve collaborated with customers running high throughput screens for herbicide residues, fatty acids, and land regulatory compliance—each field brings its own demands for clean separation.

    Where some labs try to “clear” commodity-grade solvents in-house with extra distillation or filtration, that process costs more over time and often delivers inconsistent performance. Our experience shows heading back to the plant for a process audit and root cause check fixes these issues far more surely than asking end-users to reengineer solvent quality. One faulty solvent lot, detected by a spike in background at crucial wavelengths, means lost days of method development. Years of feedback on these setbacks have reinforced the importance of solving purity at the source.

    Continuous Refinement—How Experience Shapes Manufacturing Decisions

    As direct producers, we shape manufacturing based on what labs really report. It isn’t about meeting a broad purity claim, but about handing our customers a tool they can count on, just as we expect when we set up for our own analytical runs. Each deviation logged, each customer call dissected on the floor, deepens the understanding of what matters most: a solvent that reflects not just chemical purity, but reliability through every test, under variable storage or transit conditions.

    Working side by side with research partners, we’ve tested out batch samples under stress—sunlight exposure, micro-particulate challenges, or forced aging. These in-house torture tests flagged weak packaging, or showed that switching cap suppliers created tiny bits of residue left behind, undetectable outside of high-sensitivity runs. Only by taking those lessons and looping them back into process changes do we keep each batch expected and dependable.

    Why Trust Built Into Each Run Matters

    for every lot that passes through QC, another set of bottling and storage steps is monitored. We push for transparency and open records, so labs can directly compare analytical blanks from one run to the next. Consistency doesn’t happen by chance—it follows from hundreds of specific protocol points, written and rewritten over years of troubleshooting and customer partnership.

    We’ve seen calls from labs where a single missed check on the filling line caused months of unexplained chromatographic drift. Fixing that takes humility and willingness to learn—not just bandaging the immediate issue with new filters or post-hoc cleaning, but embedding that knowledge so no future batch repeats the error. This habit of process improvement rooted in manufacturer experience spells the difference between commodity and specialty solvent lines. No checklist or off-the-shelf guideline catches every real-world pitfall for HPLC users. Only those who’ve run the lines, taken the early-morning troubleshooting calls, and stood at the intersection of production and application can keep refining quality.

    Listening to Labs, Backed by the Floor

    Feedback loops shape our everyday attention to detail. Labs call about baseline performance, new research applications, or discoveries from method development. These conversations aren’t mere customer service—they’re a direct window into how solvent quality makes or breaks new science. Every analytical puzzle returned for a plant-side audit echoes down the line, reminding us that even minute differences in grade or batch environment can alter chromatographic profiles, limit method transfer, or set back compliance approval.

    Adding this knowledge to production, we continue building a solvent line tuned to what users—scientists and analysts—find in real work, not just in theoretical purity specs. Each lesson gained lifts the floor for what HPLC-grade means, ensuring 1-Butanol can serve confidently in research, monitoring, and analytical breakthroughs. From raw material oversight to the last QC check before shipment, each step bears the imprint of those who know both the machinery and the stakes involved in high-performance liquid chromatography.