HS Code |
350679 |
| Product Name | 1-Aminocyclobutane-1-carboxylic acid hydrochloride |
| Cas Number | 1238-19-3 |
| Molecular Formula | C5H10ClNO2 |
| Molecular Weight | 151.59 g/mol |
| Appearance | White to off-white powder |
| Melting Point | 218-222 °C (decomposition) |
| Solubility | Soluble in water |
| Purity | Typically ≥98% |
| Ph 1 Solution | 2.0-3.0 |
| Storage Temperature | 2-8 °C |
| Synonyms | Cycloleucine hydrochloride |
| Smiles | C1CC(C1)(N)C(=O)O.Cl |
As an accredited 1-Aminocyclobutane-1-carboxylic acid hydrochloride factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | White crystalline powder supplied in a 25 g amber glass bottle with tightly sealed screw cap, labeled with product and hazard information. |
| Shipping | 1-Aminocyclobutane-1-carboxylic acid hydrochloride is typically shipped in tightly sealed containers to prevent moisture ingress and contamination. The packaging meets chemical safety standards, with clear labeling and a Safety Data Sheet (SDS) included. Transportation follows regulatory guidelines for non-hazardous laboratory chemicals, ensuring secure delivery from suppliers such as Sigma Aldrich, Merck, or TCI. |
| Storage | 1-Aminocyclobutane-1-carboxylic acid hydrochloride should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area. Protect it from moisture, heat, and direct sunlight. Store at room temperature or as recommended by the manufacturer (typically 2–8°C). Avoid contact with incompatible materials such as strong oxidizers. Follow all relevant chemical storage guidelines and safety regulations. |
Competitive 1-Aminocyclobutane-1-carboxylic acid hydrochloride prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Few compounds spark the same kind of reaction as 1-Aminocyclobutane-1-carboxylic acid hydrochloride in our facility. Work with cyclobutane derivatives often presents operational challenges — the ring strain, the temperature sensitivity during crystallization, all demand a watchful eye. After years spent refining our synthesis routes and production protocols, we’ve developed a reliable process for turning out 1-Aminocyclobutane-1-carboxylic acid hydrochloride that won’t surprise you mid-project, whether you’re in research or production.
Looking at this compound, the cyclobutane ring immediately draws attention. It’s a tight, four-membered ring with an amino group and a carboxylic acid, protonated to the hydrochloride salt for easier handling. During production, we’ve seen why batch consistency matters: small changes in input purity or temperature during salt formation can affect the physical form and even downstream chemical reactivity. Our own runs have taught us to monitor every step, from cyclobutanone sourcing to amination and quenching stages.
No two runs behave identically unless the input controls and isolation are tight. We keep the HPLC purity above 98.5% and routinely test not just for chemical purity, but also for moisture content and residual solvents. Contamination can come from unexpected sources — even the wrong storage drum. The hydrochloride form often cements product stability during transport and intermediate storage, but it also affects the solubility profile, making it more compatible with polar reaction systems. Working with research customers taught us how trace chloride levels impact certain downstream syntheses, especially in peptide assembly.
Our in-house process consistently produces a free-flowing crystalline material, easy to weigh and dissolve. Some suppliers focus on output volume, yet slack on filtration and drying controls; this shows up later as yellowing, caking, or sticky batches. Since our earliest scale-up trials, we learned just how big a pain even minor degradation could be on an analytical HPLC or in peptide coupling. Today, we use controlled environments, keeping oxygen and moisture exposure below established thresholds during both processing and packaging.
Pharmaceutical labs often come to us asking about the suitability of our batch for solid-phase peptide synthesis. The monomeric cyclobutane ring structure confers conformational rigidity to peptides and can act as a structural probe, and we address this head-on in our QC process. The hydrochloride salt here gives chemists easy handling, with reduced dust and more predictable dissolution behaviors, compared to the free base. Outside the pharma sector, we’ve watched materials researchers pick up 1-aminocyclobutane carboxylic acid hydrochloride for probing physical properties in polymer backbones, relying on its ring strain to influence thermal transitions. Each market values consistency, but the needs differ — so we keep communication lines open, collecting field feedback to shape our quality metrics.
If you’ve ever received a batch from an unfamiliar source that turned sticky after a week on the shelf, you know the headache — half the time, it’s trace moisture or volatile contamination, not your own storage. We take fresh samples from every batch and push them through accelerated aging tests. Working up stability data directly in-house taught us to over-dry at our own risk: too much heat or vacuum and the salt can pick up static or (even worse) degrade, making it hard to weigh or dissolve. The optimal route has proven to be gentle vacuum drying followed by immediate packaging in sealed, moisture-barrier bags.
Many labs ask, often bluntly, why order from a manufacturer instead of a catalogue house. One strong reason lies in the control over synthetic intermediates. For this compound, the route can go through various protected intermediates and final acid salt adjustment. Competing products sometimes drift from the target due to variations in synthetic steps — we routinely cross-examine chromatograms for trace impurities specific to certain reagents. Several times, we’ve spotted side products that slip past rapidly-prepared lots, especially in rapid commercial scale-up or when intermediates are sourced from inconsistent channels.
Experience also counts with the hydrochloride formation. Too little acid, and unreacted free base lingers — too much, and deliquescent salts appear, hard to store or handle. Our factory teams learned this through real-world loss of material and sticky failures in early drying rooms. Today’s controlled, step-by-step addition and monitoring during acidification and drying help us sidestep these pitfalls, delivering a consistently manageable solid to our partners.
Sometimes users ask whether they should order the free acid or its hydrochloride salt. Pulling from our own experience, we see fewer storage or usage complaints with the hydrochloride — the salt form shrugs off ambient moisture better and dissolves without floating or forming aggregates. While the acid can offer a marginal benefit in some coupling protocols, most prefer the less-hydroscopic salt, especially for extended storage or multi-step synthesis. Our own factory storage logs mark a clear difference in shelf stability and appearance, with the hydrochloride staying true to form for months even in warm, humid environments.
Building cyclic amino acids isn’t just textbook chemistry. Once we scale from gram to kilogram, every step reveals its own pain points. Ammonolysis of a cyclobutanone often takes longer than expected and rarely proceeds to ideal conversion. Early days saw batches stalling at incomplete amination or stubborn by-products resisting removal. A short time later, purification by crystallization forced us to reconsider seeding rates, solvent mixes, and cooling curves. Each run in the pilot plant taught us how crucial timing and controlled solvent removal are to get the clean, crystalline hydrochloride salt. Delays or overcooling brought on stuck filtrations or subpar yield recovery.
We keep refining these techniques. Solvent selection, especially during final precipitation, matters as much as analytical checks. Ethanol may work at small scale, but we found isopropanol or mixed solvents sometimes draw better, more manageable crystals at larger volumes. Using feedback from both our process and customer applications, we adapted our solvent drying and acidification stages to deliver tighter control over both particle size and product dryness.
One of our first big overseas shipments ran into trouble when exposed to a hot, humid port. On arrival, the otherwise pure product had clumped and absorbed moisture. Since then, we double-bag our shipments in aluminum foil liners, not just standard plastic. We also started sealing each drum or poly jar with a tamper-evident closure and include batch-specific desiccants. These simple steps save wasted batchwork and support reliable inventory for users — a clear lesson that goes beyond paperwork or technical data.
Bulk orders see special attention. We ship in uniform batch lots, each with a detailed certificate of analysis and a sample for reference. Occasionally, a customer will report issues with fine powdering or clumping, especially after airfreight. We review packaging logs directly, run simulated shipments, and routinely adjust inner liners or material densification procedures based on these real-world cases.
Working with regulated industries, we’re used to scrutiny on not just product content but documentation, batch traceability, and storage history. Electronic batch records track every synthesis and packaging stage, and we archive all in-process chromatograms and physical test reports for review. Some clients required detailed amino acid content by quantitative NMR, while others stressed low metal content by ICP. We perform these checks in-house or through accredited labs and keep the chain of information seamless, supporting customer audits or compliance reviews directly.
Since handling hydrochloride salts sometimes bounces up against import regulations or local storage laws, our documentation includes full batch origins, storage condition logs, and MSDS guidance reflecting actual observed behavior, not just generic hazard data. Somewhere along the way, we learned that clear, factual documentation does as much for trust as any technical promise.
Raw material choice for this product has evolved over years. We have vetted upstream suppliers to avoid shifts in cyclobutanone or protecting reagent quality, after learning that even one inconsistent drum can result in a batch recall. Our own procurement moved to dual-source critical inputs, with qualifying trials scheduled semi-annually. Regular input screening and trace impurity monitoring means intermediates never get blended, and our logs trace each load back multiple steps. Finished material is always segregated by batch in our warehouse; we treat partial lot mixing as a major red flag.
On process control, our shop-floor engineers maintain close lines of communication with QC — not just an afterthought, but a built-in stage in scheduling synthesis timing and scaling. Frequent pilot runs verify raw material suitability and adapt for changing seasonal conditions, like increased humidity in summer affecting crystallization. Employees handling the process routinely undergo training on cross-contamination, trace solvent detection, and emergency intervention. All this reduces batch-to-batch variance and helps ensure the end product fits demanding, real-world applications.
End-users ask about price, but even more, they ask about reliability. From our vantage point, competitive pricing means little if a batch fails in process or throws off a critical validation run the week before deadline. Consistency in 1-Aminocyclobutane-1-carboxylic acid hydrochloride brings value in less rework, shorter troubleshooting, and better final product quality in your downstream applications. We don’t chase lowest cost through shortcuts; our cost structure reflects the time saved by knowing what comes out of the drum matches both spec and expectation.
For custom applications, we field requests to adjust particle size, deliver in different packaging, or control for specific impurities. Our in-house flexibility accommodates these — based on longstanding customer partnerships and solid technical understanding, not guesswork. This adaptability has grown in response to customer needs, not imposed by top-down policies, and is key to delivering a compound that serves as both tool and building block for advanced chemistries.
Direct feedback from users in pharma, R&D, and materials science continues to refine our approach. Each comment about unexpected residue, unusual color, or processing difficulty is treated as a signal — we investigate root causes and adjust upstream practices. Regular property testing, informed by customer feedback, ensures every lot retains the crystalline, easy-to-use form expected. Repeat users over the years provide real-world data that rivals any in-house simulation; these relationships push us to keep improving both process and support.
This product’s hydrochloride form reduces risk of dusting and accidental loss compared to free acids, but operators in our facility still handle it with gloves and face protection. We learned that open handling in a high-humidity room prompts caking and slow clumping, so scales and transfer zones are equipped with dehumidifiers and local exhaust. On the rare occasion fine powders are requested, we blend under laminar flow hoods and double-check for airborne particulate.
Disposal of spent drums and liners also follows documented protocols to prevent chlorinated dust release, both for worker safety and environmental compliance. Each stage of manufacturing and shipping includes steps to reduce risk — as much a reflection of personal responsibility as regulatory compliance.
Over years in manufacturing, trial and error guides improvement more than any single theoretical insight. Small process changes, brought on by customer application or observed in factory operations, lead to a more reliable, manageable 1-Aminocyclobutane-1-carboxylic acid hydrochloride. Whether the water content dips below set points or a packaging tweak solves powder clumping, experience — both ours and that shared by partners — keeps shaping the product’s value in practical terms.
For us, real expertise means combining careful listening with grounded process control. We see this product as more than a line on an inventory sheet; it represents lessons from hundreds of batches, thousands of quality checks, and meaningful conversations with chemists and process engineers who depend on real-world performance.