HS Code |
672337 |
| Chemical Name | 1,10-Phenanthroline Hydrochloride Monohydrate |
| Cas Number | 38298-81-4 |
| Molecular Formula | C12H9N2·HCl·H2O |
| Molecular Weight | 252.70 g/mol |
| Appearance | White to off-white powder |
| Solubility | Soluble in water and ethanol |
| Melting Point | 198-200 °C (decomposes) |
| Storage Temperature | Room temperature, tightly closed |
| Purity | Typically ≥98% |
| Synonyms | o-Phenanthroline Hydrochloride Monohydrate |
| Ph 1 Solution | 4.5-6.0 |
As an accredited 1,10-Phenanthroline Hydrochloride Monohydrate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 25g bottle features a white, wide-mouth, HDPE container with a blue screw cap, labeled with Sigma Aldrich branding and specifications. |
| Shipping | **Shipping Description:** 1,10-Phenanthroline Hydrochloride Monohydrate (Sigma Aldrich/Merck/TCI chemical grade) ships in tightly sealed, chemical-resistant containers. Handle and store at room temperature, away from moisture. Classified as non-hazardous for standard transport; however, observe all safety regulations for laboratory chemicals. Accompanied by a safety data sheet (SDS) for proper handling instructions. |
| Storage | **1,10-Phenanthroline Hydrochloride Monohydrate** should be stored in a tightly sealed container at room temperature (15–25°C), in a cool, dry, well-ventilated area away from light and incompatible substances such as strong oxidizing agents. The chemical should be kept away from moisture and direct sunlight to maintain stability and purity. Always follow local regulations and manufacturer guidelines for safe storage. |
Competitive 1,10-Phenanthroline Hydrochloride Monohydrate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Our journey with 1,10-Phenanthroline Hydrochloride Monohydrate began more than a decade ago, back when tighter process control in complexometric titrations had become key for many laboratories aiming to hit that reliable endpoint in analysis. Over years of production, we’ve fielded countless questions from customers who needed a truly dependable, consistently pure reagent for both research and industrial application. Each new batch reveals just how much detail goes into producing a molecule used for everything from determining trace metals to catalyzing organic reactions.
What keeps labs coming back is our repeated focus on purity and hydration control. For our production runs, we offer the model 1,10-Phenanthroline Hydrochloride Monohydrate, batch consistency guaranteed at scale. Typically, we ship it as fine, off-white crystalline powder—this form helps avoid caking, keeps reactivity stable, and assures seamless dissolution during preparation of complexometric titration solutions. At assay, our material demonstrates purity greater than 99%, as determined by HPLC and confirmed by independent analytical checks, always with careful records trailing every container. Our own technical team oversees these analytical protocols at multiple points in the production workflow.
Scientifically, the monohydrate variant leads to better storage stability and more predictable physical handling, especially compared to the anhydrous form. There's no hidden lesson here. Once the hydrate is right, chemists stop losing material to ambient humidity swings, and they don’t end up with hard-to-break lumps in reagent jars. We’ve devoted significant resources over time to rationalizing our drying and recrystallization processes, so the final product stays easy to weigh and work with—an achievement born out of observed lab difficulties rather than arbitrary formulation.
For every batch of 1,10-Phenanthroline Hydrochloride Monohydrate we ship, we take note of the end-use—most notably, its pivotal role as an indicator in the quantification of iron. In volumetric analysis, the reagent presents distinct colorimetric changes upon binding ferrous ions. The red-orange complex forms cleanly, proving especially valuable in water quality labs, municipal plants, and any analytical setup needing rapid, accurate iron titration. This application doesn’t just exist in manuals; we get direct feedback from university analysts and municipal labs who require a reagent that delivers fast, unmistakable endpoint detection, every time.
Beyond iron titration, researchers across pharmaceutical labs and environmental testing stations have adopted this compound as a ligand in a range of coordination studies. In our facility, discussions with synthetic chemists highlighted routine use in catalysis research—especially where controlled chelation is needed during transition metal-catalyzed organic reactions. We’ve also seen an uptick in use among those developing fluorescent sensors for trace metal detection. Demand spikes after relevant publications prove just how deeply this molecule roots itself in both the academic and applied scientific world.
We continually receive inquiries about the interpretation of color shifts in complexation reactions. Years of accumulated experience tell us that lot-to-lot consistency in color response often comes down to purity, trace metal content (especially copper or nickel impurity), and the precise hydration state. We’ve adapted our quality program to monitor for these outcomes, knowing that an undetected contaminant—even at sub-ppm levels—can skew analytical results. In the most demanding settings, this extra vigilance makes or breaks accuracy. That’s where being a manufacturer with hands-on insight into raw material handling and process control offers greater command over final product quality.
Throughout the manufacturing process, we take a hands-on approach, not shying away from granular monitoring wherever crucial. Early on, we learned that dehydration steps—and their timing—directly influence the final product’s usability. If batch drying extends beyond a specific margin, the risk for anhydrous conversion increases, which won’t store as reliably and causes inconsistent readings in gravimetric analyses. Blending technical skill with continuous feedback from our QC laboratory ensures that moisture levels retain the precise monohydrate signature every analyst expects.
Contamination remains a constant specter. Trace heavy metals—often originating during upstream syntheses or leaching from metallic reactor surfaces—complicate applications where sensitivity occupies center stage. We source raw 1,10-phenanthroline from tested global partners, but each consignment meets our strict standards only after in-house purification and multiple cycles of recrystallization. Each tray of crystals gets sampled and assayed before blending with hydrochloric acid and strictly controlled water content during final synthesis. Our approach doesn’t allow room for shortcuts.
Customers have asked if non-hydrated or higher hydrate forms exist, or how our material compares to substitutes such as 2,2’-bipyridine hydrochloride. We’ve experimented with alternatives and seen how lab results shift accordingly. The monohydrate’s predictability—both in color response and solubility—sets it apart. To this day, we haven’t found another chelating agent that matches the sharpness of endpoint or durability of our 1,10-Phenanthroline Hydrochloride Monohydrate, especially in standardized solutions susceptible to precipitation or background color. Consistent particle size reduction during milling finishes off each lot, promoting rapid solution and easier transfer for titration work.
Over years of working directly with academic labs and large-scale industrial teams, we anchor our R&D in lived experience—feedback, complaints, and collaborative troubleshooting sessions shape how we approach custom specifications. Standard runs deliver on key performance metrics, but special projects sometimes need tighter impurity limits or alternative packaging to support field work in remote sites. We treat every special request like a technical challenge, not a sales pitch. Adjusting for water content or controlling for surface area are frequent tweaks, solved through open dialog with practitioners and iterative testing in our in-house facilities.
Our technical group fields frequent questions regarding best practices for solution preparation, endpoint visualization, and long-term storage. Across these discussions, several issues crop up repeatedly: caking during humid months, unexpected discoloration due to improper capping, and confusion around solution concentration adjustment. Our support doesn’t end at shipment. Technical documents, custom video calls, and quick-response troubleshooting have built trust with both new and repeat customers. Manufacturing at scale brings unique perspective to these issues—a deep understanding of how subtle changes in process parameters ripple out in application.
While most of our batches serve the analytical chemistry domain, our network stretches into water treatment utilities, food laboratories, and even pigment formulation developers looking for rigorous iron testing tools. This breadth grounds our production priorities. Each feedback loop—involving shipping delays, storage mishaps, or performance under suboptimal lab conditions—feeds directly into improved process design and documentation. Over time, this iterative approach has translated into better raw material handling, more user-friendly containers, and clearer guidance for solution mixing or storage.
Modern analytical labs face clock-driven schedules and tight quality deadlines. One late delivery or inconsistency in product properties throws off entire testing routines, especially in regulatory environments where each step must stand up to audit. We keep logistics transparent: production lead times, batch tracking, and on-demand batch data are all communicated clearly. Our storage and transport solutions favor moisture control, so each shipment matches intended specification upon arrival—whether destined for local colleges or international labs facing harsher climate conditions.
Batch homogeneity is no marketing promise—in our operation, it comes from precision dosing of hydrochloric acid, careful control of reaction kinetics, and strict environmental monitoring during drying and storage. Reports have come in from labs that once tolerated off-brand or re-packaged chemicals, only to switch to direct-from-manufacturer supply after reliability failed at a critical moment. We build our supply lines and QA protocol around these practical failures, acknowledging that one mishap costs far more than the price of a premium grade reagent.
Questions about environmental footprint and safety have shaped how we optimize waste management, reactant sourcing, and personnel training. Every year, we update handling procedures, invest in closed-loop solvent reclaim systems, and retrain operators in both process and emergency response. Experience shows that investment in a safer, cleaner production line returns value far beyond corporate reporting—it filters into day-to-day reliability, employee well-being, and customer confidence. 1,10-Phenanthroline Hydrochloride Monohydrate—despite its relatively small batch volumes compared to bulk industrial salts—receives this full attention, without shortcuts or trade-off.
Direct competition mostly comes from trading operations, which frequently repackage or dilute bulk import product for lab resale. Experience navigating countless customer support calls tells us how a missing lot record or unexplained performance change costs extra time and sometimes invalidates test results. We address these gaps by maintaining strict provenance and supporting full traceability from precursor raw material through to finished lot.
A few groups try to replace 1,10-Phenanthroline Hydrochloride Monohydrate with self-mixed alternatives or substitutes like 2,2’-bipyridine. In our hands, these alternative indicator systems seldom achieve equal performance in iron-specific detection tasks. Endpoint clarity falls, and color changes muddy when impurities creep above sub-ppm critical thresholds. Blending and crystal habit also shape solubility—overlooked by resellers, but obvious to anyone running consecutive analyses in fast-moving water or food test labs.
The monohydrate form’s superiority reveals itself most starkly in daily lab work. Compared to the anhydrous or variable hydrate options, user experience points to fewer batch failures, less time remaking solutions, and reduced wastage from degraded or lumpy powders. These operational details—often dismissed in textbook specifications—reflect the accumulated feedback from chemists, lab managers, and process engineers who run year-in, year-out iron titrations for regulatory compliance or discovery research.
Raw material access challenges the global supply chain, but direct relationships with upstream producers let us influence starting compound quality, shipping conditions, and trace metal contamination risks. Over time, we’ve shifted away from spot-market buys, building ongoing partnerships and joint process audits. This upstream influence, combined with our batch-by-batch downstream release checks, closes the loop on quality. The outcome: one clear standard, matched and repeated with each container shipped.
Operator experience counts for a lot when process anomalies hit—over-drying, contaminate carryover, or faulty solution preparation. Our senior floor supervisors have spent years learning from these mishaps, introducing incremental controls such as automated humidity monitors inside storage rooms or double-checks before product release. Any minor tweak to batch parameters gets recorded and reviewed, so every process improvement finds its way into the next cycle.
Scaling up isn’t just about making more product. Each uptick brings new risks of batch variance or unintended impurity. To navigate this, we mechanized key steps, avoiding corners cut by manual-only operations, while still letting skilled staff intervene when signals point to drift. This mixed approach—automation plus hands-on attention—lets us produce more without sacrificing reliability. Stability testing on retained samples links each finished container to the originating conditions, lessons, and personnel involved.
Feedback from the field regularly shapes our strategy—the open exchange with practitioners uncovers problems missed by any internal focus group. Several years ago, an environmental lab flagged instances of lot-to-lot reagent inconsistency under field test conditions. We traced the source to air humidity variation during final drying that barely registered in our own lab, but spiked impact once shipped to tropical regions. That detail pushed us to upgrade drying chambers and update packaging design, directly connecting field reality to production design.
Scientists expect their feedback recognized and reflected—precision requirements for trace iron quantification or consistency in solution preparation can’t wait on lengthy supplier negotiations. We run regular review sessions with R&D partners to keep improvements ongoing. Sometimes this has led to unexpected directions—preparing smaller lots tailored to academic cycles or offering extra consulting for odd-ingredient matrixes. We draw satisfaction from these real-world exchanges as much as the lab data; they keep our craft rooted in scientific progress, not marketing jargon.
Our perspective on 1,10-Phenanthroline Hydrochloride Monohydrate doesn’t stem from a one-off project or batch. It has grown from years of direct response to chemists and researchers who require precision, transparency, and accountability from their chemical source. In a landscape dotted with repackaged and relabeled lots, our standing as an original manufacturer means we alone manage every input, adjustment, and release. The molecule’s role in analytical chemistry stretches far beyond routine assays—supporting water safety, driving innovation in metal detection, and improving environmental monitoring at scale.
Every decision, from raw material sourcing to final packaging, arises from lessons learned on the production floor—not from distant corporate boardrooms or third-party quoting engines. We stand behind our 1,10-Phenanthroline Hydrochloride Monohydrate because we have lived through the pitfalls, debated improvements with users, and continually adapted from feedback and laboratory data. That’s a position only a manufacturer can claim, and one we aim to uphold with every batch moving forward.