HS Code |
459607 |
| Product Name | 1,1,1,3,3,3-Hexafluoropropan-2-ol |
| Synonyms | Hexafluoroisopropanol, HFIP |
| Chemical Formula | C3H2F6O |
| Molecular Weight | 168.04 g/mol |
| Cas Number | 920-66-1 |
| Appearance | Colorless liquid |
| Boiling Point | 58-60°C |
| Melting Point | -4°C |
| Density | 1.606 g/cm3 at 20°C |
| Purity | For HPLC (High Performance Liquid Chromatography) |
| Odor | Characteristic, pungent |
| Refractive Index | n20/D 1.276 |
| Flash Point | 27°C (closed cup) |
| Solubility | Miscible with water and organic solvents |
| Vapor Pressure | 101 hPa (20°C) |
As an accredited 1,1,1,3,3,3-Hexafluoropropan-2-ol [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 1,1,1,3,3,3-Hexafluoropropan-2-ol [for HPLC], 100 mL, supplied in an amber glass bottle with tamper-evident cap. |
| Shipping | 1,1,1,3,3,3-Hexafluoropropan-2-ol [for HPLC] is shipped in tightly sealed containers, protected from moisture and light. It is classified as hazardous; transport complies with international regulations (IATA, IMDG, DOT). Packaging ensures chemical stability and safety, and includes labels indicating its flammability, toxicity, and handling precautions. |
| Storage | 1,1,1,3,3,3-Hexafluoropropan-2-ol [for HPLC] should be stored in a tightly closed container, in a cool, dry, well-ventilated area, away from heat and sources of ignition. Keep away from incompatible substances such as strong oxidizers and acids. Store at room temperature, away from moisture, and ensure proper chemical labeling according to Sigma Aldrich, Merck, or TCI guidelines. |
Competitive 1,1,1,3,3,3-Hexafluoropropan-2-ol [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The laboratory world has grown more demanding as analytical work faces tighter tolerances, increasing throughput, and the race to identify trace-level impurities in complex matrices. Chromatographers rely on chemicals that deliver consistent performance, purity, and safety. Over years of producing high-purity solvents and specialty reagents for laboratories, we learned the real work starts long before packaging and shipment. Our responsibility goes beyond factory walls—a product only makes sense if it truly supports scientists in their daily separation challenges.
1,1,1,3,3,3-Hexafluoropropan-2-ol, used for HPLC, stands out as a specialized reagent designed for analytical accuracy. The specific batch that leaves our facility must answer to real-world HPLC needs, not just pass a generic check. We tailor the manufacturing process to guarantee a product as free as possible from by-products, residual water, or ionic contaminants, keeping in mind that even tiny impurities may show up as ghost peaks, reduce sensitivity, or compromise baselines, especially in high-sensitivity or gradient runs.
Years spent handling fluorinated alcohols revealed how even a trace impurity could complicate HPLC data. These lessons shape every stage of our manufacturing process for 1,1,1,3,3,3-Hexafluoropropan-2-ol. We start with raw materials and reagents meeting our own in-house benchmarks for trace metals, stability, and purity. Most competitors source at a lower grade, reasoning that post-production clean-up can compensate. Our experience says otherwise: using only the highest starting materials means less waste, more predictable reactions, and a finished product less likely to introduce unknowns into your chromatogram.
Reactor conditions, temperature, and handling are under strict control to minimize side products and accidental contamination. Pressure and atmosphere inside the reactor cells are continuously monitored, as both can affect the degree of hydrolysis and, ultimately, impact the solvent’s suitability for UV detection.
Every batch of 1,1,1,3,3,3-Hexafluoropropan-2-ol we produce for HPLC goes through repeated distillation using glassware and fluoropolymer-lined systems to minimize leaching of unwanted metals or organic residues. Post-distillation, we use molecular sieves and vacuum-sealed transfer for drying. Our experience shows that direct air exposure, even during bottling, can allow in enough atmospheric moisture to degrade purity below HPLC thresholds. Rigorous in-line moisture checks and sealed automated bottling significantly reduce risk at this critical last step.
Labs don’t operate in the abstract. We know that customers run HPLC systems in diverse environments— from moisture-controlled research institutes to field labs with unpredictable humidity. That’s why our 1,1,1,3,3,3-Hexafluoropropan-2-ol comes with a moisture content below 0.01 percent, based on hundreds of in-process Karl Fischer titrations, not just a single certificate. UV absorbance is checked from 200-400 nm, making sure that the baseline comes out flat, with no broad or spiking background absorbance.
We also recheck for residual acids, halides, and non-volatile impurities. These can cause corrosion in HPLC pumps and columns, especially with prolonged usage in automated routines. Reducing ionic burden isn’t just about purity, it’s about safeguarding the hardware that keeps your lab moving.
General-use grades of this fluorinated alcohol often serve as fluoropolymer modifiers, textile processing aids, or organic synthesis intermediates. Their focus is on cost rather than performance in analytical applications, so allowed impurity levels are much higher, and residual moisture or metal traces don’t raise concern.
HPLC-dedicated 1,1,1,3,3,3-Hexafluoropropan-2-ol must surpass these grades in every critical attribute: lower water content, lower UV-active residue, and strict limits on organic by-products. Even the packaging matters—our bottles feature fluoropolymer liners, proven to prevent leaching of sodium, potassium, or calcium ions, which would otherwise wreak havoc on baseline stability.
From customer feedback, we know that typical industrial grade solvents can cause suppressed signals, streaky baselines, or increased maintenance on analytical equipment. Our team receives reports of system backpressure rising after only dozens of runs. Investigation revealed silicon and phosphate traces originating from substandard solvent grades. These experiences underline why analytical work requires a specialized product and why investing in manufacturing controls is not optional.
Some analytical challenges aren’t solved with a simple purity upgrade. Over time, we’ve seen scientists encounter shifts in retention time or ghost peaks that turned out to result from residual stabilizers and microcontaminants in solvent bottles. For that reason, our batches face in-depth impurity scans—GC, mass spectrometry, and elemental analysis—aimed at picking up even obscure side products. Customers called us with odd peak clusters on their chromatograms, and side-by-side analysis isolated the culprit to invisible stabilizers used by third-party bottlers. Transparency prompted us to print full impurity profiles, not just a sparse handful of certificate numbers.
Evaporation and handling present practical issues. If an analyst uses a solvent that picks up ambient moisture or adsorbs carbon dioxide, the result might be slightly acidic solutions that alter analyte retention or column life. To limit this, we install environmental monitors around our bottling lines, so temperature, pressure, and humidity readings feed into final inspection reports. Customers aren’t left to guess why one bottle performs better than another; our quality controls document the handling history of each lot.
Laboratories increasingly demand not just pure chemicals, but those created with responsible use of resources and minimization of hazardous waste. Our team constantly looks at ways to capture and recycle waste streams during production, reducing overall fluorocarbon loss. Excess or expired solvent is sourced from our customers and processed in our return-to-recycle program, ensuring fewer drums require landfilling or incineration.
Workflow improvements include installation of solvent recovery units and real-time monitoring for emissions, methods tested and refined through daily factory practice. This not only shrinks our environmental footprint but also allows us to guarantee a stable, contamination-free supply, even during regulatory or supply chain disruptions.
Switching from general-purpose to dedicated HPLC grade reduces instrument cleaning and lowers overall waste solvent output, since systems maintain stable performance across more injection cycles, translating into cost and environmental savings.
Producing a single perfect bottle is easy. Maintaining reliable, batch-to-batch consistency in large volumes is harder and required us to rethink every step, from incoming verification, through closed-system synthesis, to automated bottling and digital tracking.
We share chromatographic data and real-world application examples upon request, confident that results in your own lab will align with ours. Our technical support team, built from professionals with years at the bench, regularly consult with labs that face drift or contamination issues. Practical advice matters more than rote answers, so we keep communication lines open for on-the-ground troubleshooting.
For instance, several major pharmaceutical customers reported improved reproducibility after switching from standard to our dedicated HPLC grade, especially during analysis of low molecular weight amines and peptides. The difference traced back to reduced trace metal contamination correlated with fewer spurious peaks and a lower maintenance burden on columns and injection valves.
Product improvement isn’t just a matter of fine-tuning process controls or tweaking certificates. Our team makes regular visits to customer facilities, observing firsthand how solvents move from storage to instrument. Actual use sometimes uncovers difficulties missed in laboratory evaluation—unclear labeling, bottle designs prone to drip, or packaging incompatible with lab automation robots.
We redesigned our container shape and closure system after visiting a QA laboratory where frequent cap removal exposed solvent to needless air, contaminating sensitive injections. The new closure, now standard, only requires a single upward motion, exposing less surface area and maintaining integrity longer. Every improvement traces to real lab experience, drawn from hundreds of discussions, product returns, and honest criticism—information we treat as vital, not just as complaints.
Customers let us know when documentation falls short, which led us to overhaul not only labeling but also online resources. We now supply QR codes with batch numbers, giving instant digital access to origin, full impurity spectra, and handling tips. Customers have told us how this access have helped them track issues back to a single shipment and solve investigative headaches that might otherwise linger.
Cutting corners on solvent grade often backfires. Many laboratories start with industrial or “research” grades, only to discover hidden costs—extra instrument downtime, increased calibration drift, or even failed critical projects. Impurities may build up unnoticed over hundreds of runs, damaging columns or detectors, demanding unexpected replacement.
With fluorinated alcohols like 1,1,1,3,3,3-Hexafluoropropan-2-ol, keeping impurities as low as technology permits isn’t just about ticking boxes. It comes down to respect for chromatographic science and the value of reliable data. Inconsistent solvent can derail years of work, especially in regulated industries or forensic laboratories. Feedback from environmental, clinical, and pharmaceutical sectors points to spikes in false positives and unpredictable baselines as the most common pain points with lower grade material. Using the right product up front guards against these errors and, over a full year’s operation, saves both time and costly reanalysis.
Analytical chemistry keeps advancing, pushing limits of detection ever lower. Solvents must keep up. We invest heavily in new purification technologies, such as hybrid adsorbents and advanced filtration systems, which remove problem-causing trace compounds that older protocols could miss. We use direct customer runs as final arbiters for whether a new process delivers tangible benefits.
Our R&D partnerships with chromatography labs help refine product batches, blending lab and manufacturing perspectives on what matters—faster resolution, lower background noise, and lower risk of drift across wider temperature and humidity conditions. These relationships help us future-proof our solvent portfolio, aiming to support whatever the next wave of regulatory or technical challenges brings.
Specialized use cases in biotech, pharma, and materials research increasingly rely on unique solvent systems. Our experience shows that trace contaminants in 1,1,1,3,3,3-Hexafluoropropan-2-ol affect not just classic reversed-phase HPLC separation, but also advanced workflows such as chiral analysis, ion-exchange, and post-column derivatization. We collaborate with users to track unexpected anomalies they see on their instruments and bring solutions back into our manufacturing cycle.
For example, a pharmaceutical customer struggling with inconsistent enantiomer separations traced their issues to an industrial solvent grade. By switching to our high-purity HPLC grade, their yield reproducibility improved, and QC investigations linked this step to stabilized product release metrics and less rework.
Labs need more than just a bottle—they need information, documentation, and real support. We routinely update our guides to include application notes, troubleshooting advice, and direct-access support for urgent analytical problems. We take calls from customers troubleshooting strange baseline drifts, or those needing advice on best practice for precise transfer and storage.
Our open communication channels mean customers always get straight answers: if an observed issue might connect to solvent handling or batch variation, we work together openly to resolve it. This transparency is built on trust, shaped by years of responding directly to feedback and the practical demands of modern laboratories.
Every bottle of 1,1,1,3,3,3-Hexafluoropropan-2-ol for HPLC represents more than just chemical product; it’s the result of accumulated knowledge and deliberate choices at every stage of production. Analytical users rely on results only as strong as the weakest reagent they use. Our commitment runs from process control to user support, making sure every step aligns with what chromatography scientists actually need, not simply what old standards require.
We continue to invest in the tools, people, and partnerships that raise the bar for solvent manufacturing. Customers can trust that every batch reflects not just regulatory compliance, but a working partnership with the scientists and analysts who depend on true purity and reliability. By engaging directly, we close the loop between laboratory discovery and real-world manufacturing, building on lessons learned and staying deeply invested in analytical excellence.