HS Code |
491812 |
| Product Name | 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol [for HPLC] |
| Chemical Formula | C4H4F6O |
| Molecular Weight | 168.07 |
| Cas Number | 920-66-1 |
| Appearance | Colorless liquid |
| Purity | ≥99.0% (HPLC) |
| Boiling Point | 58-60°C |
| Melting Point | -4°C |
| Density | 1.596 g/mL at 25°C |
| Flash Point | 15°C (closed cup) |
| Solubility | Miscible with water and most organic solvents |
| Refractive Index | n20/D 1.277 |
| Storage Conditions | Store at room temperature, tightly closed |
As an accredited 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol [for HPLC] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol (100 mL) is sealed in an amber glass bottle with tamper-evident cap and label. |
| Shipping | 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol (for HPLC) is shipped in tightly sealed containers, protected from moisture and light. Transportation follows chemical safety regulations, with labeling for flammability and toxicity. Shipping documents include Safety Data Sheets (SDS). Delivery is typically via specialized carriers for hazardous laboratory chemicals, ensuring compliance and safe handling. |
| Storage | 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol (for HPLC; Sigma-Aldrich/Merck/TCI) should be stored in a tightly sealed container, in a cool, dry, and well-ventilated area away from heat, sparks, and open flames. Protect from moisture and direct sunlight. Store separately from incompatible substances such as strong acids, bases, and oxidizers. Keep container tightly closed when not in use. |
Competitive 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol [for HPLC] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
After almost two decades working as a manufacturer in fine specialty and analytical-grade chemicals, few substances draw as many questions as 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol, especially among chromatographers and analytical chemists. This compound, often called HFIP, plays a unique role in HPLC (High-Performance Liquid Chromatography) applications, and only by working closely with researchers and quality specialists do we see how nuanced those demands can become.
HFIP’s chemical structure (C4H4F6O) stands out with its six fluorines attached to a tertiary alcohol, creating properties seen rarely elsewhere in HPLC solvents. Most products leaving our production lines, destined for HPLC use, undergo rigorous purification cycles aimed at removing trace-level organics, moisture, and acidic particles. Many laboratories request purity over 99%, water content under 0.01%, and specific conductance below 2 μS/cm, which we check batch by batch—not just on paper, but by direct QC verification using our in-house HPLC and Karl Fischer titration.
It’s not just about hitting those numbers once. Hitting the same mark each time means handling raw materials with care—airtight drums, inert transfer lines, and glass-lined reactors become daily considerations. Every syntheses run gets logged in a way that tracks even slight variations, including batch temperature or column elution times, because tiny tweaks influence how HFIP interacts downstream, both as a solvent and as a mobile phase modifier. Consistency matters, and minor shortcuts show up fast once the bottle is opened in a busy analytical lab.
The real-world value of HFIP doesn’t come from any abstract promise. It comes from daily problem-solving in analytical chemistry. HFIP works especially well when separating peptides, oligonucleotides, and tricky small molecules that stick to columns or show up poorly with standard solvents. The six fluorines in its makeup lower hydrogen bonding capacity, offering selectivity in reverse-phase HPLC that’s not available from regular alcohols. Compared to methanol or acetonitrile—both widespread solvents—HFIP manages to pull out rare or subtle analytes without massive shifts in elution time.
In our experience, method developers come to us with two main requests: reliable elution of complex analytes and minimal baseline drift. Because HFIP stays optically transparent in both UV and mass spectrometry wavelengths, it doesn’t add noise or create ghost peaks. This allows for stronger data integrity, especially during high-sensitivity mapping of biological samples or trace-level synthetic byproducts.
Its volatility adds another layer of value. After separation, HFIP evaporates almost residue-free, so post-HPLC processing gets faster—no worrying about downstream reactions clogging up due to leftover solvent. In peptide mapping or pharmaceutical analysis, these differences can add up to hours or days in saved processing time per month.
A key part of our job involves direct conversations with HPLC specialists. Most solvents in general-use labs—methanol, ethanol, isopropanol—aren’t optimized for niche targets like nucleotides or modified peptides, which need more sophisticated handling. Even specialty purities of these solvents miss out on HFIP’s unique tertiary structure. That structure reduces unwanted interactions with both silanol groups on silica columns and charged analyte moieties. To give one concrete example: laboratories running high-sensitivity oligonucleotide separations often see sharper peaks and higher recoveries with HFIP, compared to trifluoroethanol or conventional buffer systems.
From the manufacturing side, the challenge comes in maintaining low levels of metal ions and halide contaminants. These trace contaminants from raw materials or the environment can easily swamp the tiny signals that advanced biotech companies look for. During one collaborative project with a genomics group, we lowered boron and sodium to below 10 ppb, using both ion-exchange polishing steps and custom glass storage, because their work was sensitive to every minor impurity leaching from plastic or steel.
Another common question focuses on the difference between HFIP and trifluoroacetic acid (TFA), which also sees common use in LC-MS. Though both contain multiple fluorines, TFA acts as a strong acid, occasionally interfering with downstream mass spec due to adduct formation or excessive charge suppression. HFIP, on the other hand, offers buffering capability with less masking of real peaks, which leads to more useful data and easier spectra interpretation without the long sample workups needed to remove residual acids.
Most researchers never get to see what happens behind the doors of a chemical plant. Each drum or bottle of HFIP for HPLC sits at the end of a long chain of steps. From sourcing fluorinated feedstocks all the way through to small-batch distillation and sealed, inert atmosphere bottling, oversights at any point introduce risk. We don’t just rely on supplier specs. Incoming raw materials undergo verification against multiple spectral and chromatographic references to keep even minor side products out of the supply. Contaminants like perfluorinated impurities, trace acids, or residual solvents need to be pulled down to levels most analytical instruments can’t even measure directly—but our customers find them soon enough if we miss them.
Continuous feedback from customers drives routine improvement. Labs routinely send LC chromatograms or mass spectra for joint troubleshooting, especially if something odd shows up that points to solvent impurities. We respond with targeted solvent polishing or adjust rinse cycles. That loop between user experience and process monitoring pushes us to tighter specs—like reducing environmental oxygen in packaging or upgrading trace moisture controls based on seasonal shifts in plant humidity.
One of the least discussed but most important points: labeling and traceability. Every lot we ship includes a batch report, not just for regulators but for researchers doing long-term studies. By tracking trace impurity patterns and correlating them with analytical results, we can spot and address changes in quality months before any formal “out of spec” result shows up in testing.
No two customer applications run quite the same. Though HFIP solves typical HPLC problems for many analytes, it poses challenges if handled carelessly. Its volatility means open handling can degrade samples or shift concentrations, so we advise immediate capping and using airtight glassware, drawing from mistakes and best practices picked up in our own pilot plant.
Over the years, we’ve tuned our own plant’s workflow around the quirks of HFIP. Routine solvent checks focus as much on storage and transport as on production. Our logistics people maintain cold-chain storage options and track light exposure during transit. Unsealed containers risk picking up airborne moisture, which even at one drop per liter can skew HPLC results or create ghost peaks. It is these day-to-day details, often overlooked, that make the biggest difference once the solvent gets pipetted into a mobile phase in the laboratory.
Every few months, someone reaches out reporting unexpected peaks or odd retention times. Our support team, usually staffed by former process chemists, walks through the basics: checking for contamination from transferware, confirming mobile phase ratios, and reviewing column conditioning. More often than not, trace water or backpressure issues turn out to be the culprit, and they often trace back to storage or bottling rather than the original product. This ongoing cycle of support encourages us to revisit our own QC routines, tighten seals, consider gas-flushing on certain bottle runs, or switch out packing materials if there’s a risk of leachables.
Direct feedback from frequent users—like pharmaceutical QC labs or biotech startups working at the single-sequence level—presses us to keep documentation and support channels open. We learn as much from their troubleshooting as they do from our guidance, pushing for ever-tighter controls and process tweaks.
Chemical manufacturing is never static, and the same is true for the processes we develop for HFIP. Over the last five years, we reinvested in broader spectrum analytical tools—adding NMR alongside MS, ICP-OES for metals, and even trace fluorine analysis. New feedback from peptide synthesis and nucleic acid labs taught us about specific contaminants and error sources—topics rarely covered in text references but clear in actual workups. Those additional layers of analysis let us tune each HFIP lot to real-world use cases, not just standard catalog specs.
We keep refining operations, sometimes in ways that don’t make it into sales brochures. Distillation head temperature fine-tuning, vessel material upgrades, and pressure calibration become daily points of focus. For instance, glass-lined vessel maintenance reduces iron leaching, while rapidly switching to vacuum distillation minimizes breakdown of HFIP at high temperature, ensuring both purity and yield stay at optimum levels. Each small step prevents one more chromatographic artifact or unwanted background signal later in the workflow.
Precise attention to waste handling also shapes our choices. Because of HFIP’s fluorinated nature, its disposal requires special treatment to avoid environmental persistence. In-house methods ensure unused or waste HFIP segregates from general organic waste, collecting it for specialist incineration or chemical neutralization to prevent fluorocarbon release. Our customers—especially those with environmental certifications—demand transparent, tightly managed end-of-life solvent protocols, and we match that expectation because we build workflows with full lifecycle consideration from day one.
Transparency with customers remains foundational. Open sharing of production and analysis records speeds root-cause analysis and supports method validation. More than once, a shared lot certificate or impurity spectrum broke a data bottleneck for a partner lab, saving costly repeat runs or experimental redesigns.
Our close relationships with customers mean we don’t just sell solvent—we help guide optimal use and sometimes even method development. Many HPLC methods use 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol as a mobile phase additive with acetonitrile or water. We walk labs through concentration ranges or pH adjustments that prevent precipitation or buffer imbalances across columns and instruments, as consistent application boosts both repeatability and data quality.
Lab managers appreciate having batch-matched sets for critical series work. We encourage pre-testing lots with pilot runs and always keep a few reserve containers for customers aiming to validate methods against legacy data. This involves straightforward recommendations, drawn from real runs in our own applications labs, to avoid issues like air bubble formation, solvent phase separation, or interfering carryover during injection.
We also stress frequent calibration—not only of HPLC columns but of balance and pipettes—because HFIP’s low viscosity and volatility change volumetric assumptions compared to higher-boiling solvents. Skipping those small checks easily causes drift, not only in concentration but across multi-day sample series. Knowing this firsthand, we collaborate actively with customers setting up new protocols, so small training gaps never escalate into large data bottlenecks.
Keeping working stock at cool, stable temperatures avoids pre-evaporation, especially in humid regions. We reinforce the use of quick-connect septa and fluoropolymer-compatible caps, matching the unique chemical profile of HFIP. Our technical team runs monthly webinars and open virtual office hours, sharing both our in-house data and accumulated customer best practices.
The regulatory climate for fluorinated organics grows stricter each year. Our plant invests ahead of new limits—wastewater monitoring for trace fluorocarbons, emission abatement using scrubbers and closed-loop vapor capture—but the most impactful change comes from collaboration with downstream users. Environmental, Health and Safety teams from large customers push us for audited lifecycle documentation, transparent composition files, and rapid recall protocols if a batch falls outside agreed specs.
Recent years saw growth in demand for HFIP outside traditional HPLC: in protein folding studies, advanced materials formulation, and as a modifier for peptide synthesis. Researchers and production chemists discover new uses or blend it with different solvents, which challenges us to provide reliable advice on solvent compatibility, long-term storage, and waste minimization. Experience tells us no two workflows look exactly alike, so we rely on deep product knowledge and active listening to help troubleshoot even the most creative applications.
On the regulatory side, we document full traceability from supply chain to final container, allowing customers to meet both domestic and international compliance reporting requirements. International standards for purity, hazardous materials handling, and bottling integrity mean constant investment in employee training and equipment upgrades. Each new certification process—ISO, REACH, local hazardous waste guidelines—adds to plant complexity, but our decade-plus relationships with regulatory bodies ease the path and ensure shipments never face unexpected customs or field test issues.
With HFIP, subtle production and handling tweaks differentiate robust HPLC performance from erratic results. Our years in the field let us fine-tune against not only published specs but also unpublished quirks—hydrogen bonding avoidance, carryover reduction, and column life extension. Information gathered from site visits, troubleshooting sessions, and benchmarking batches ensures each bottle gets formulated not to average requirements but to the toughest real-life cases.
One clear difference from commodity-grade material lies in our focus on rapid batch analysis and close customer feedback loops. By integrating in-line moisture and purity monitoring with frequent user reporting, we catch rare contaminants or process shifts before a single ounce reaches the customer bench. End-to-end ownership—starting with raw material vetting through to final packing and shipping—keeps the chain tight and makes troubleshooting data-driven rather than speculative.
Working side-by-side with analytical scientists, we gain perspective on emerging target molecules, shifting analytical standards, and advanced instrumental methods. That insight pushes continual process improvement—whether by revising filtration practices, switching bottle suppliers to prevent interaction, or rolling out new training for plant personnel on advanced analytical interpretation.
Every batch of 1,1,1,3,3,3-Hexafluoro-2-methyl-2-propanol we produce reflects long-standing dedication to direct customer partnership, solid processes, and adaptation to new challenges. Whether the solvent goes to a pharmaceutical lab, a university research group, or a specialty analytical facility, our support teams keep open lines for both day-to-day troubleshooting and large-scale validation work.
Open project support, transparency in reporting, and a focus on practical improvements—drawn from years of hands-on manufacturing work—help us align our production with the demanding needs of cutting-edge analytical chemistry. Each improvement in purity, consistency, or handling helps yield clearer data, faster workflows, and more confident scientific progress, both now and in the future.