|
HS Code |
325449 |
| Product Name | Z-Tyr-OBzl |
| Synonyms | N-Cbz-L-tyrosine benzyl ester |
| Cas Number | 1175-50-2 |
| Molecular Formula | C24H23NO5 |
| Molecular Weight | 405.44 |
| Appearance | White to off-white solid |
| Purity | Typically ≥98% |
| Melting Point | 117-120°C |
| Solubility | Soluble in methanol, dichloromethane, ethyl acetate |
| Storage Temperature | 2-8°C |
| Chemical Class | Protected amino acid derivative |
| Smiles | C1=CC=C(C=C1)COC(=O)[C@@H](CC2=CC=C(O)C=C2)NC(=O)OCC3=CC=CC=C3 |
As an accredited Z-Tyr-OBzl factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Z-Tyr-OBzl is typically supplied in a 1g amber glass vial with a white screw cap and Sigma Aldrich-branded labeling. |
| Shipping | Z-Tyr-OBzl (chemical grade) from Sigma Aldrich, Merck, or TCI is typically shipped in tightly sealed, inert containers to preserve stability. It is transported under ambient or recommended cool, dry conditions. Packaging follows safety and regulatory standards, including labeling and documentation for chemical handling and shipping compliance. |
| Storage | Z-Tyr-OBzl (Sigma Aldrich/Merck/TCI, Chemical Grade) should be stored in a tightly sealed container, under dry, cool conditions (2–8°C), and protected from light and moisture. Store in a desiccator if possible. Avoid exposure to air and strong oxidizing agents. Ensure proper labeling and keep away from incompatible substances. Follow manufacturer’s safety guidelines for handling and storage. |
Competitive Z-Tyr-OBzl prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Each day, our plant works through the full depth of synthesizing Z-Tyr-OBzl, offering consistency batch after batch. We know this compound inside out because we've produced it through all seasons, on all shifts, with operators who spot subtle color change or detect aroma the moment something’s off. Our lab benches hold not just instruments but years of iterative development, learning directly from every failed and every successful batch.
Z-Tyr-OBzl, benzyl N-α-(benzyloxycarbonyl)-L-tyrosinate, stands as a staple intermediate for peptide research and small-scale pharmaceutical manufacturing. Demand for this product comes from discovery labs, pilot programs, and process scale-up teams working to create new peptides, test innovative modifications, or assemble complex sequences that require precise building blocks. This molecule shows up in places where mistakes cannot be hidden; any deviation may cascade through downstream synthesis. We hold ourselves to strict standards because our clients demand it by force of their own workloads and grant timelines.
Over the years, we've refined the process for Z-Tyr-OBzl to avoid yellowing, tackle unwanted byproducts, and push toward a purity consistently above 98%. The underlying chemistry may seem simple on paper, but those in the trenches of synthesis understand every reaction’s tendency to drift or generate impurities. Achieving high purity isn’t about luck; it’s about tackling the granular details: choice of solvent, work-up technique, and storage conditions are all controlled. Heating and cooling curves aren’t decided by chart but by lived trial. Each analytic result—HPLC, NMR, MS—comes not as just data, but as proof that our methodology holds under scrutiny.
Customers working in peptide assembly face different issues: solubility inconsistencies, cross-contamination, and shelf life anxiety. We respond not with generic statements but with specific accommodations learned from hands-on troubleshooting with real labs. For example, we’ve covered the request for tighter particle cut and uniform granule size by adjusting our milling operations, not simply by changing package descriptions. Technical sales conversations become conversations between colleagues in the same business, not distant script-reading. We send new sample lots to scientists whose feedback steers our tweaks — our product evolves because customers direct real feedback to our technicians and chemists, never to an anonymous channel.
Quality control has teeth because we built our production around the expectation that every lot of Z-Tyr-OBzl will pass the same standards. We keep archive samples, trace reagent lots, and log every deviation, no matter how small. This method doesn’t just meet regulatory requirements; it satisfies the chemist who acts as the final link in peptide chain assembly. That person needs assurance every time they open a container that the material’s properties are as expected; nothing can remain ambiguous. We get that assurance from blending regular operator training, cross-functional audits, machine calibration schedules, and rigid standard operating procedures. The result? No unpleasant surprises in melting point range, appearance, or chromatogram.
From synthesis to purification to packing, everything happens inside our own facility. We don’t lose visibility on our product’s journey, and neither do our customers. They ask questions and get lived answers, not hearsay relayed by several handlers. If a peptide lab reports an unexpected shift in NMR, our analytical team opens the archive, and we compare lot against lot, not speculation against marketing claim. This chain of custody can’t be replicated by traders or brokers—it flows from direct engagement with the stuff itself.
Z-Tyr-OBzl doesn’t behave like all other amino acid derivatives. Its benzyl-ester feature tackles issues that the standard methyl or ethyl esters often complicate, especially during selective deprotection in solid phase synthesis. In practice, labs choose Z-Tyr-OBzl when they want to avoid acid-catalyzed decomposition or when downstream chemistries favor a bulkier leaving group. This property sets it apart from Fmoc- or Boc-protected tyrosine esters: the different protecting groups present specific advantages in protecting schemes, and we know from long partnerships with academia and biotechs which routes their chemists prefer.
Our technical support doesn’t offer one-size-fits-all answers; we hear from peptide chemists about the realities of solid-phase synthesis, the crude product recovery griefs, and the bottlenecks from side-product complications. We've hosted, observed, and troubleshooted peptide assembly on our own pilot benches, with our own product feeding real world projects—so we pass on workable advice based on collective experience, not just theory.
Many partners voice concerns about stability and storage. Z-Tyr-OBzl wants a dry, cool environment, but our packing process shields it from atmospheric moisture — each bottle undergoes vacuum-sealing followed by inert-gas overlay. We’ve had to redesign this step after seeing long-distance samples arrive with clumping or surface yellowing under subtropical humidity. By solving with chemistry, not marketing, we push shelf life to practical horizons. Direct conversations with researchers have helped us improve inner liner material, desiccant volume, and even adjusted the fill volume per bottle to maintain usability from the first weigh-out to the last scoop. Death to open jars languishing in the back of the fridge — with feedback in hand, we confirm product integrity, not just for one day, but over months of real use.
Our HPLC calibration mixes hit the right retention times because we process them ourselves — not afterthought, but necessity after years of tracking subtle shifts. We’ve tracked splits in UV absorbance that didn’t show in a basic purity check, steering us to tweak purification methods. Every NMR spectrum in our database gets cross-examined against both starting material and finished product because we know the look of a true “clean” run. Direct feedback from peptide synthesis users—those who lose time to ghost peaks and coelution—targets our focus. We don’t just release a certificate of analysis; we build an entire product history with every batch so you aren’t left explaining analytics to reviewers or supervisors.
Batch size requirements change from project to project, and the market can swing quickly between gram-scale and kilogram needs. Our response relies on actual manufacturing agility: plant scheduling, shift adjustments, and raw materials purchasing all align around our equipped facilities, not via make-to-order outsourcing. We know the machinery's sweet spots and loading factors. We convert scale-up headaches into streamlined production, skipping the recalibration risks faced by those who shuffle between outsourced tollers and contract labs. Emergency scale-ups for a client on tight deadlines don’t mean wild procurement rushes—they mean shifting plant schedules and working overtime, leveraging our own resources, infrastructure, and supply partners we've relied on for years.
Though many suppliers talk at length about “compliance” in general terms, we go through regulatory documentation for every batch of Z-Tyr-OBzl. That includes not only compliance with local, regional, or widespread standards, but also providing traceability for end-users facing stringent submission deadlines. Visiting auditors find well-maintained logs, controlled waste handling, and consistent storage. Regulatory agencies expect complete transparency, and our daily discipline—meticulously logged process steps, archived batch reports, and up-to-date MSDS sheets—ensures both repeat business and continued approval.
In this field, price matters—no one can ignore it. Yet, people come back to us for a reason. It’s not just raw pricing, it’s the hidden value: no lost days due to unexplained failures, no headaches with delayed shipments, no constant corrections after testing. Synthesis time costs, purification demands, and clean-up after failed intermediates add up much faster than a few cent difference in unit price. Our clients stay for the accumulated benefit—years of hands-on troubleshooting now reflected in our Z-Tyr-OBzl output. If cost were the only issue, cheaper shortcuts abound—but reliability, purity, and on-time delivery win out in projects where outcomes aren’t negotiable.
Standard packaging often underestimates the realities of modern research. For pack-down, dispensing, and sample storage, we’ve redesigned our bottles over multiple iterations, gathering input directly from research assistants and technical leads about what clogs a scoop or loses a label during repeated handling. Our approach to filling, capping, and outer wrapping ensures safety and presentation, yes, but also usability — batch information remains easy to read, closure threads resist caking, and desiccants keep clumping away. Each step in packaging grew from someone in our customer roster sharing feedback, not from a one-size-fits-all decision made far from the lab.
People who try our Z-Tyr-OBzl find the difference within the first usage. No unexpected crystals. No odd odor that can’t be explained. Material handles predictably from first opening to final aliquot, avoiding daily re-justification of a project’s materials. Consistency comes from dedication to repeat process refinement and not taking shortcuts from batch start to batch finish. Our staff live with the consequences of finished product, so the laboratory’s success matters more than marketing narratives. This difference stems from the operator who sees the line every day, the lab analyst who traces each impurity, and the research customer who places another order after months of continual use.
Peptide labs are busy places, and every lost hour fighting solubility, contamination, or document ambiguity ripples out. We address these problems not by giving vague guidance, but by sending out technical advisors to trial tweaks on site with customer teams. Our process improvements get updated not merely in internal memos, but adopted straight into shop-floor training and production change-logs. If a new issue appears—unexpected byproduct, minor stability blip—we contact users with what we know, suggest process tweaks, and work alongside our technical community. Solutions come from two-way feedback, not insular theorizing.
Shipping regulations and sourcing have tightened over recent years. We manage dangerous goods registration ourselves, document every transfer by in-house staff, and coordinate closely with end-user facilities to handle customs or regulatory bottlenecks. Many times, smaller labs lack resources for time-consuming paperwork; we step in and share the right documents drawn directly from our regulatory compliance archives, not from stock templates.
Z-Tyr-OBzl has evolved through years of hands-on iteration, feedback, and direct troubleshooting. Its development traces every step of peptide chemistry's growing complexity, shaped by real needs and shaped again by real-world challenges. As manufacturers, we do not merely direct a supply line—we shape a workflow that reaches from our raw material storage to the precise moment a lab scientist weighs a sample on the other end.
If any question remains about this product’s relevance, suitability, or difference, our answer is not a rehearsed sales pitch. Instead, we invite open dialogue. Our product’s reputation grows from each success in the lab; we’re here to stand behind every gram, every day, with both the experience and readiness to adjust, improve, and support actual customers in real-world projects.