West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Uridine 5'-Diphosphoglucose Disodium Salt Hydrate

    • Product Name Uridine 5'-Diphosphoglucose Disodium Salt Hydrate
    • Alias UDP-Glucose
    • Einecs 213-165-4
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    643892

    Product Name Uridine 5'-Diphosphoglucose Disodium Salt Hydrate
    Synonyms UDP-glucose disodium salt hydrate
    Cas Number 27879-29-8
    Molecular Formula C15H22N2Na2O17P2•xH2O
    Molecular Weight 566.24 g/mol (anhydrous basis)
    Appearance White to off-white powder
    Storage Temperature -20°C
    Purity ≥98%
    Solubility Soluble in water
    Ec Number 248-669-4
    Inchikey JAJRUKRMZYYNDZ-BJBGGDMISA-L
    Mdl Number MFCD00150612
    Catalog Numbers Sigma Aldrich: U6750, Merck: 103614, TCL Chemical: TBA9951
    Grade Biochemistry Grade
    Usage Biochemical research, substrate for glycosyltransferases

    As an accredited Uridine 5'-Diphosphoglucose Disodium Salt Hydrate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing White solid powder in a 1g amber glass bottle, labeled with Sigma-Aldrich branding, product details, hazards, and storage information.
    Shipping Shipping for Uridine 5'-Diphosphoglucose Disodium Salt Hydrate (Sigma-Aldrich/Merck/TCI Chemical) is typically conducted under cool and dry conditions, with secure, leak-proof packaging. Temperature control (room temperature or refrigeration) may be required depending on quantity and supplier instructions. All shipments comply with relevant chemical transport regulations and include comprehensive safety documentation.
    Storage Uridine 5'-Diphosphoglucose Disodium Salt Hydrate should be stored at -20°C in a tightly sealed container, protected from light and moisture. Avoid repeated freeze-thaw cycles. Ensure the storage area is dry and well-ventilated. Suitable storage preserves the chemical’s stability and prevents degradation. Refer to the manufacturer’s Safety Data Sheet for specific handling and storage guidelines.
    Free Quote

    Competitive Uridine 5'-Diphosphoglucose Disodium Salt Hydrate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Uridine 5'-Diphosphoglucose Disodium Salt Hydrate: Clarity from the Manufacturer’s View

    Introduction – Understanding Uridine 5’-Diphosphoglucose Disodium Salt Hydrate in Practical Context

    Most people working in the biochemical and pharmaceutical sectors encounter nucleotides early in their lab careers, but seeing the impact a specific compound can have in a real-world setting goes well beyond textbook curiosity. We manufacture Uridine 5'-Diphosphoglucose Disodium Salt Hydrate (often called UDP-glucose disodium salt hydrate), and every batch we produce draws on decades of practical experience in chemical synthesis, purification, and application. Our perspective comes from the synthesis lines, not from market summaries or catalogues. The difference matters.

    Uridine 5'-Diphosphoglucose disodium salt hydrate occupies a central position in biochemical pathways, especially in carbohydrate metabolism, glycosylation processes, and various diagnostic protocols. Working in production and development, we’ve noticed research needs often stretch far beyond product codes or COA tables. People want to know about real purity, hydration levels, consistency, and reproducibility—criteria that can make or break research outcomes.

    What Sets This Compound Apart – Real Differences in Practice

    Our UDP-glucose comes as a white to off-white powder, with consistent solubility, reliable purity, and precise identification supported by NMR and HPLC. We routinely meet specifications at >98% purity (HPLC), and water content remains controlled at levels specified through Karl Fischer testing. Each lot sees close monitoring for sodium content and residual solvents, because we know how trace contaminants—often invisible or glossed over in bulk resupply orders—can contaminate cell lines, alter enzyme kinetics, or throw off assay results.

    Some competitors supply similar nucleotide sugars, but the devil hides in the details: stability profiles, batch-to-batch consistency, and careful control of crystalline hydrates determine how a product is handled in a working lab. Our production lines avoid mixed-phase batches; we stick to a well-defined hydrate, minimizing unpredictable behaviors during reconstitution or weighing. That attitude traces back to our roots making materials for analytical chemists, researchers, and developers, who demand answers when an experiment veers off course.

    We manufacture in facilities that place robust cleaning standards and staff training at the core of daily operations. The process scale runs from pilot through full GMP-compliant lines, should customers require it. Routine releases focus on small-molecule research use, and on specialty applications in enzymology, assay development, and glycoprotein synthesis. Research groups in carbohydrate biology, clinical diagnostics, and pharmaceutical development keep returning for quality—less for marketing claims, more because results in the lab reflect our careful synthesis and processing controls.

    Usage in Labs and Industry – More Than a Reagent

    Uridine 5’-diphosphoglucose belongs to the family of nucleotide sugars, with a critical role donating glucose in glycosylation reactions. Synthetic chemists, protein engineers, and cell biologists alike reach for UDP-glucose as a substrate for glycosyltransferases, which build up the carbohydrate chains found in glycoproteins, glycolipids, and cell walls. In our experience, the difference between a smooth and an unpredictable synthesis often comes down to the nucleotide sugar’s integrity—how fresh it is, how consistently it dissolves, and how its pH profile stabilizes after reconstitution. These factors tend to get overlooked by teams purchasing from general chemical distributors, but in-house they receive daily attention.

    In practice, UDP-glucose enters into enzymatic assays that probe glycogen synthase activity, UDP-glucose 4-epimerase function, or in the construction of complex carbohydrate libraries. Our customers use it in the assembly of synthetic pathways, particularly for making rare or tailored glycosides. Analytical labs run standards and controls using our material, thanks to the reproducibility of our batches. Researchers working on metabolic pathway elucidation or enzyme kinetics depend on substrate and product masses that behave reliably from one experiment to the next. This has real consequences for grant funding, publication credibility, and even downstream clinical development.

    For those scaling up to preparative work or fermentation processes, the reliability of sodium content and hydrate state becomes far more than a technical detail. Reagent-grade stocks, if not manufactured carefully, can upset carefully buffered enzyme preparations or affect the osmolarity of bioconversion systems. Over time, even subtle batch inconsistencies introduce noise into analytical results or yield troubleshooters more headaches. That’s why in our workflow, every container ships with a freshly printed release certificate, checked at multiple stages in production, not just the final load-out.

    Confronting Challenges in Purity and Stability

    Making high-purity UDP-glucose means more than running a synthesis and drying the product. From the earliest pilot batches, we’ve noticed how exposure to moisture, minor variations in crystallization solvent, or even the duration of final drying can affect how the salt hydrates and stores. Loss of water of hydration, or its gain during storage and transit in humid regions, has a measurable effect on the weight-by-weight dosing—details that matter to those conducting quantitative work.

    Controlling such variables calls for a combination of real-time process monitoring and batch records, not just spot sampling. Our operators log environmental humidity, run precise Karl Fischer titrations, and repeat powder mixing where microheterogeneity creeps in. Production teams get real-time feedback, with extra steps at final fill and packaging to ensure material ships with the exact hydrate state on the label—prepared with the knowledge that some shipments may cross climates or experience temperature cycling. As manufacturers, we’re acutely aware generic quality statements fall flat when a customer calls with a misbehaving lot, so our culture centers on preventative work, traceability, and customer feedback loops.

    Where our UDP-Glucose Differs from Similar Products

    Chemically, UDP-glucose looks straightforward—combining uridine, two phosphate groups, and a glucose moiety, counterbalanced with sodium ions to make it water-soluble. This apparent simplicity masks several hurdles other materials stumble over: purity of starting uridine, removal of organic byproducts from the diphosphorylation step, and elimination of heavy metals. Only with tight controls and analytical vigilance do we keep levels of inorganic phosphate, residual ethanol (from crystallizations), and potassium in check.

    Compared to common alternatives, like the lithium salt or other sodium/monohydrate forms sourced from mass-market plants, our product arrives consistently as the disodium salt with a defined hydrate state. Poorly controlled solvate mixes appear perfunctory at first but drift in pH or osmolarity, impacting enzyme assays and clinical testing. With us, the focus lands on endpoints: Will this rehydrate as anticipated? Does the sodium content register what the titration shows? Do downstream processes, such as labeling or radioisotope incorporation, see full conversion at intended masses? Our in-house team retests every complaint or aberration, reporting findings directly back to the technical staff overseeing synthesis.

    For teams performing analytical glycomics or metabolic tracing, impurity levels can trigger false readings in MS or HPLC. While some producers offer material “suitable for laboratory use,” we commit to process tracking, minimal lot-to-lot drift, and old-fashioned batch records, retained for years. That stems not from regulatory checkbox needs but ongoing requests from academics, biotech firms, and quality managers in need of reassurance on supply continuity. Unlike catalog suppliers who drop lines when a material lags on margin, we’ve refined and sustained our UDP-glucose stream in response to clearly stated needs—down to modifications of batch scale, alternate packaging, and even custom documentation as projects scale from benchtop trials to pilot facilities.

    Insights from the Manufacturer’s Bench

    People often ask about the difference between “research-grade” and “analytical-grade” UDP-glucose, and we point back to the handling. We maintain a high-purity line, but can increase the stringency for critical clinical or diagnostics applications. Every upgrade in water content specification or contaminant profile means investment—in staff training, instrumental upgrades, and lab floor organization. The end result benefits the end user, but the journey balances scale economics and the real-world stress of maintaining a continuous, reliable product line.

    We train our team to think beyond the batch they’re working on. Every shift logs critical process data and uses targeted analytics to confirm outcomes, not just compliance. In our world, days rarely end after a scheduled batch release; instead, our crew reviews out-of-specification runs, addresses recurrent anomalies, and sets up root cause analyses, especially after feedback from end-users. These loops power continual improvement that gives research groups and production sites alike assurance in every order. Manufacturers who skip this discipline risk recalls, customer frustration, and disruptions that set back years of research investment.

    Applications – Practical Field Observations

    The substrate’s use in glycosyltransferase assays draws special attention from the biotechnology and pharmaceutical development sectors. Our technical staff helps customers set up initial runs, tune reaction conditions, and troubleshoot issues ranging from partial conversion to anomalous HPLC traces. Through these calls, we realized how enzyme lots may struggle with batch-to-batch inconsistencies in substrate—a pattern repeated outside our facility where procurement sometimes overrides technical vetting. Stable hydrate levels and real batch records reduce such troubleshooting.

    Beyond enzymatic assays, UDP-glucose feeds into research on bacterial cell wall biosynthesis, particularly in Gram-negative pathogens. Here, minor impurities can confound genetic or metabolic readouts, leading to wasted cycles on mutant screening or pathway mapping. Analogously, researchers building biosynthetic carbohydrate chains, or working on chemoenzymatic syntheses, call for gram to kilogram scales, with documentation of transition metal content, residual solvents, and alternative salt forms. We respond to these requests in real time, adjusting packaging, scaling, or documentation, supported by a close connection between R&D, QA, and the floor staff running the production centrifuges and dryers.

    UDP-glucose’s role in glycogen biosynthesis pathways also finds service in diagnostics and disease biology, driving research into metabolic disorders, diabetes, and hepatic dysfunction. Stability concerns, solubility upon rehydration, and reproducibility across batches can complicate longitudinal studies or multi-center research. Many of our users collaborate across geographies, so we synchronize our release protocols to ensure that shipments arriving months apart will dissolve, weigh, and react as anticipated, independent of transit conditions or shelf time.

    Challenges and Our Approach to Solutions

    Every manufacturer wrestles with economics and technical complexity. UDP-glucose remains a relatively niche product, so production scale choices have consequences. We combine large pilot runs for commonly requested grades with flexible batch plants for custom or specialty projects. Fluctuating starting material supplies—such as uridine or phosphate sources—occasionally challenge continuity, so we’ve built redundancy into supplier qualification, and keep buffer stocks adequate to span such disruptions.

    Concerning impurities, our standard operating procedures routinely adapt to new analytical requirements: whenever customers push for upgraded detection sensitivity, we invest in lower-detection-limit ICP-MS and more sensitive organophosphate screening. The analytical team meets regularly to inspect certificate templates, re-audit critical supply chains, and run retained samples from previous lots, answering any complaint not only by replacing material but by sharing data back with the requestor. This practice grows out of the simple observation that repeat business and trust come from responsiveness, not just product availability.

    Another persistent challenge reflects a tension between production capacity and customized needs. Some partners require material pre-weighed for single-use, in air-free vials or ampoules, while others order in large jars. Short production runs risk cross-contamination or packing imbalances, risks minimized by dedicating controlled areas and calibrated filling systems. Our crew fields unique requests for documentation, certificate modifications for specific protocols, and validation data for critical clinical studies. Such feedback cycles empower our process engineers and lab scientists to continuously update procedures and anticipate next-generation user needs.

    Pushing for Improvements—Ongoing Steps on the Shop Floor

    Every year, through feedback and our own developmental research, we uncover opportunities to tighten limits on contaminants, enhance packaging for moisture stability, and rationalize lot tracking. We monitor finished goods with stability trials, benchmarking performance at real-world temperatures and transit durations. Those results feed back into adjustments in desiccant packaging, tighter environmental controls during packing, and batch stretching trials under simulated lab environments.

    We’re transparent about provenance and quality outcomes, providing open access to historical batch data, analytical reports, and improvement logs for repeat clients. Global supply chain disruptions expose short-term and long-term risks, so our management teams meet regularly to cross-train staff, document best practices, and ensure shipment continuity should any primary route or vendor fail.

    Real improvements also stem from the front lines—the staff crimping vials, labeling containers, and collecting real-time operator feedback during the packaging process. Our approach includes continuous learning, regular technical meetings, and an open feedback culture that values operator observations on small details—such as shifts in powder flow, static build-up, or seal integrity—that could turn into costly field failures if left unaddressed.

    Conclusion: Integrity from Start to Finish

    Supplying UDP-glucose as the actual manufacturer means we own the whole chain, from synthesis to quality release and shipment. Every batch embodies the daily concentration and care we believe serious research requires. We don’t treat this material as disposable, interchangeable commodity—years of lessons from batch variability, real-world troubleshooting, and hands-on interaction with researchers push us to continue refining our product and support. We know integrity in manufacturing is tested not in sales pitches, but on laboratory benchtops and research project timelines, where reliability, purity, and a direct line to technical expertise keep experiments and innovation moving forward. With every new inquiry, request, or critique, we recommit to the time-intensive, detail-oriented processes that build not just quality products, but genuine partnerships with the scientific community.