HS Code |
327349 |
| Product Name | Triethylammonium Bicarbonate Buffer (1M) |
| Chemical Formula | C6H15NO3 |
| Molecular Weight | 153.19 g/mol |
| Concentration | 1 M |
| Appearance | Colorless liquid |
| Ph Range | 7.5 - 8.5 (at 25°C) |
| Storage Temperature | 2-8°C |
| Solubility | Water soluble |
| Shelf Life | 12 months |
| Common Uses | Buffer for enzymatic digestion in proteomics |
| Density | Approximately 1.01 g/mL at 25°C |
As an accredited Triethylammonium Bicarbonate Buffer (1M) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Triethylammonium Bicarbonate Buffer (1M), 500 mL, supplied by Sigma-Aldrich/Merck/TCI, packaged in an amber, leak-proof plastic bottle. |
| Shipping | Triethylammonium Bicarbonate Buffer (1M) is typically shipped at ambient temperature. The product is securely packaged in sealed containers to prevent leakage or contamination. It is labeled as a non-hazardous chemical according to standard regulations, but should be handled with care. Ensure receipt and storage in a cool, dry place upon delivery. |
| Storage | Triethylammonium Bicarbonate Buffer (1M) from Sigma Aldrich, Merck, or TCI Chemical should be stored tightly closed in a cool, dry, and well-ventilated area, preferably at 2–8°C (refrigerated). Protect from light and incompatible substances such as strong acids or oxidizers. Ensure proper labeling and avoid freezing. Follow manufacturer guidelines and relevant safety regulations when handling and storing. |
Competitive Triethylammonium Bicarbonate Buffer (1M) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Triethylammonium bicarbonate buffer (1M), often shortened as TEAB, features on the workbenches of many scientists and production teams for good reason. In our factory, we manufacture TEAB following batch records drawn from years spent listening to real-world lab reports and optimizing our processes. We start with pure triethylamine and high-purity bicarbonate to control ionic content, then dissolve and combine these in water treated to pharmaceutical standards. The result is a colorless solution with a neutral to slightly basic pH that actually holds steady batch after batch. Downstream labs don’t have to adjust pH or stress over variable components, because our focus from start to finish is producing solution with consistent, reliable results.
On a typical production day, technicians use stainless steel mixing vessels fitted with continuous pH and conductivity monitoring. Raw materials undergo multiple checkpoints before they reach the mixing stage. Every operator knows from experience that a slip at the material selection stage creates a headache for everyone, and the entire plant thrives because everyone watches for purity. Because of this foundational work, finished buffer shows steady spec compliance, lot after lot.
Some newcomers glance at TEAB’s simple chemical formula — (C₂H₅)₃N·HCO₃ — and assume it’s straightforward. Those same people often call with questions after running into problems with harsh background signals, odd mass spec fragments, or poorly controlled reactions. They find out that TEAB favors certain kinds of workflows for a reason. Once you standardize it right, it won’t leave stray signals in the background or break down into messy byproducts. Care at the manufacturing site ripples forward into a smoother day in the lab.
Our factory’s 1M TEAB buffer comes in clear, laboratory-grade bottles, less prone to leaching organics than lower-end containers. Inside, the buffer’s 1M concentration isn’t just a number—it speaks to the prep work we put in so users can jump straight to their process without hours spent fine-tuning. Buffer at this molarity offers enough capacity to keep pH stable across a range of ionic loads, whether you’re working on a patch of proteomics or tuning LC-MS injections.
From protein digestions, to peptide clean-up, to mass spectrometry sample loading, 1M often hits the balance between buffering strength and sample volatility. This means the solution supports you through steps that require robust buffering, but it also clears out gently during lyophilization or vacuum drying, leaving little behind that might suppress signals.
We’ve watched countless customers, from university labs to biomanufacture lines, face the challenge of matching their solvents for seamless injection into downstream mass spectrometers. TEAB at 1M concentration dissolves readily in water and evaporates clean in a rotary evaporator or speed-vac setup. Where other alkyl ammonium salt buffers might clog up columns, degrade to produce noise, or refuse to evaporate clean, TEAB’s volatility means what goes in, comes out, and leaves little trace to interfere with analysis. You see sharper, cleaner spectra, and you spend less time cleaning.
Protein and peptide scientists working in our own R&D teams, or those who drop by for factory tours, often talk about the unpredictable world of post-translational modification analysis. Complexity rules these samples, and traditional phosphate or Tris buffers create silencing problems during electrospray ionization in LC-MS/MS work. TEAB sidesteps these signal-squelching pitfalls because it won’t hang around to break down into heavy, sticky residues. We learned the hard way that the moment you switch to phosphate, signal quality falls straight off—a finding confirmed by hundreds of published protocols worldwide.
Another group, formulators working in RNA and oligo synthesis, have leaned on TEAB for desalting prior to mass spectrometry. Here, the buffer’s high purity and volatility pay dividends. After solid-phase synthesis, desalting steps using 1M TEAB rinse out strongly ionized contaminants, which otherwise risk suppressing signals and reducing quantification reliability. In these workflows, TEAB acts as a friendly ghost: deeply present during purification, but gone without a trace by the time mass analysis begins.
In peptide mapping or enzymatic digestion projects, especially in quality assurance labs, we find that TEAB at 1M concentration works well in dilution because it maintains pH through longer digestion times. Unlike Tris or acetate buffers, which tend to buffer within strict, low-molarity windows, 1M TEAB allows a broader range of conditions without sudden drift. This boosts confidence that you’ll see peptides and not a wash of breakdown products due to pH drop.
Every buffer brings its own unique quirks, and anyone who has prepped both TEAB and classic phosphate buffer knows they serve very different needs in modern analysis. Phosphate or Tris buffers, reliable as they are for UV or visible spectroscopy, persist in samples much longer. That’s a big problem for LC-MS work, especially when prepping samples under time or throughput pressure. In one test series in our own QC lab, phosphate buffer stuck around even after repeated vacuum cycles, while TEAB vacated cleanly, delivering minimal background interference.
Some users ask why they shouldn’t just grab ammonium bicarbonate, since ammonium’s volatility is famous for MS compatibility. Over months at the bench, experienced analysts have shown that the triethylammonium cation stabilizes bicarbonate differently, providing a pH stickiness that the smaller ammonium ion can’t offer. Standard ammonium bicarbonate can slip in pH during long incubations, but 1M TEAB hugs that middle ground, preventing abrupt changes midway through a critical digestion or desalting run. This isn't just marketing—we’ve seen the impact on mass spec signal clarity and have the comparative runs to back it up.
We’ve also had clients ask about using TEAA (triethylammonium acetate) instead. TEAA works in reverse-phase HPLC under some circumstances, but it doesn’t buffer pH as steadily in bicarbonate-compatible workflows. Acetate anions sometimes introduce extra chemical noise or can react with modifications on the peptide or oligo, causing yet another round of troubleshooting. In many high-sensitivity workflows, that extra noise can ruin a week’s worth of discovery.
Standardizing TEAB production under ISO and GMP environments didn’t just improve paperwork—it squeezed out the inconsistencies that would otherwise show up downstream in mass spec data. Over countless batches, careful evaporation studies reveal why some alternatives leave smears, while our TEAB pulls away with the analyte, gone in a vacuum without a trace. We make sure lots clear every stage of final inspection before shipments leave our docks, solving headaches before they start.
Some suppliers dilute down to 0.5M or less and ship product that doesn’t buffer as strongly, hoping customers won’t notice. We’ve watched this play out in the real world: a user grabs slightly less concentrated buffer thinking it’ll stretch farther, but then faces batch-to-batch variation, weaker pH control, and the risk of ‘hidden’ contaminants. At higher molarity, you get the luxury of diluting back without inviting drift—something we’ve proved by spiking samples across dozens of production lots.
For our own R&D, we run every batch through a panel of mass spectrometry and chromatographic screens before bottling. We check for micro-impurities—small amines, volatile organics, trace metals—that can sneak into other buffers when raw material QC falls short. Every chemist here can recall the time an impurity eluded standard screening but cropped up in customer spectra. It only takes one round of background interference to cement tighter input controls for many production cycles forward.
We prepare our 1M TEAB in pharmaceutical-grade ultra-pure water, using closed mixing systems and filter down to sub-micron size. Why bother? Because even a speck of dust or metal catalyzes breakdown or prompts sticky byproduct formation during storage. Investing in top-end equipment up front saves everyone stress down the line, whether the buffer ends up in a GMP biologic workflow or a research bench run.
We don’t just ship buffer—you’ll find our teams walking our own lines, troubleshooting sample prep for clients, and shadowing downstream analytic runs. Once, a customer flagged mass spec anomalies traced back to a competitor’s off-grade buffer. We compared our TEAB, shipped from the same production day, and the anomaly vanished. Turns out, small details in the manufacturing space shape bigger results in the analytical space.
Supply chain fluctuations can trigger panic hoarding, but by stocking raw materials in volume and qualifying every supplier ourselves, we keep output steady even when market prices spike. This discipline keeps our production lines open and customer needs met—no last-minute shortages, no panicked tweaks to the formula. Our supply chain team remembers the batch that arrived with trace contamination, an event that led us to double down on supplier audits and batch-level traceability.
We train every technician in not just the “how” but the “why” for buffer prep. That means they recognize when a water source drifts even slightly off spec or when a container receives a micro-crack that could let in contaminants. Experience on the line means they head off cross-contamination or pH drift before it leaves R&D and becomes a troubleshooting call a thousand miles away.
With tighter regulatory scrutiny on everything from gene therapies to biologics, buffer consistency has shifted from nice-to-have to non-negotiable. Modern bioproduction lines depend on every reagent performing as predicted—not once, but every day. Whether clients run peptide, oligo, or biopharmaceutical programs, inconsistent buffering derails timelines and eats budgets. Analysts, project leads, and quality experts talk about their need to trust every input, not to waste time recalibrating every week.
Every TEAB bottle we ship reflects hard-won knowledge earned over years on the factory floor and in upstream process support. We focus on what matters most: unwavering composition, scrupulously clean handling, dependable bottle-to-bottle consistency, and direct access to manufacturing data. Customers lean on our transparency, which cuts down on guesswork—confidence that their buffer comes from a team who understands that every deviation results in data headaches and project setbacks.
Centralizing all key steps in-house, from raw input selection to finished product qualification, spells the end of third-party guesswork. Our analytical team can provide detailed batch records, impurity profiles, and in-use validation studies upon request. We don’t pass off quality as someone else’s concern—every outcome circles back to our own teams and equipment.
Behind every buffer order is a set of specific needs, pressures, and applications, whether that means supporting a span of critical mass spec runs in a clinical trial or standardizing large-scale peptide syntheses. Buffer manufacturers who listen closely, not just ship and forget, see trends early—emerging workflows, regulatory shifts, or new analytic strategies. Our teams spend as much time speaking with application scientists as they do with purchasing agents, so guidance is more than just a spec sheet: we share actual troubleshooting experience from our own lines and those of our clients.
We’ve seen labs struggle with high viscosity or precipitate formation using other buffering agents at elevated concentrations. With TEAB at 1M, handled and filtered properly, these issues do not crop up in practice. Our technical support groups compile and share internal learnings: how to check for early signs of carbonate precipitation, how to optimize vacuum evaporation at scale, and how to handle shelf life under different storage situations. Every tip comes rooted in field experience, not just manual page copying.
No batch leaves our site without review by process chemists who run every step as if they’re the end-user clocking hours in the lab. They know firsthand how one subpar buffer bottle clogs an LC-MS line or leaves faint shadows on mass spectra. By folding user feedback into every revision and monitoring storage stability in real-world, high-humidity environments, we make adjustments that matter: tighter lot release specs, smarter container designs, or even higher throughput filtration stages.
As analytical and preparative workflows have grown more demanding, TEAB’s role has also deepened. Modern proteomics and nucleic acid workflows expect volatility, pH stability, and compatibility with high-end analysis. Our research team works alongside partners in biomedical and biotechnology fields, monitoring how shifts in regulatory guidelines or technology upgrades impact buffer needs. Last year, shifts in global oligo synthesis practices required stricter salt controls; we responded by implementing higher-precision batch monitoring, which produced more robust data for all users.
In one partnered workflow for therapeutic peptide screening, downstream mass spectrometry flagged trace alkali contamination from competitor-supplied TEAA. By adjusting our production and running legacy product through higher sensitivity mass spec, we pinpointed the source and retooled our tank cleaning protocols. Each time science asks more from buffer purity and consistency, we invest in tools, training, and methods to deliver reliability at scale, not just for one-off custom orders.
TEAB buffer isn’t just a commodity liquid—it reflects thousands of hours in process design, real-world troubleshooting, and day-to-day factory oversight. We ship bottles, but we also ship the confidence that your next batch matches every bottle that came before, freeing scientists to invest their best work where it counts: on results, discoveries, and progress.