|
HS Code |
779793 |
| Product Name | Triethylammonium Acetate Buffer |
| Chemical Formula | (C6H15N)C2H3O2 |
| Molecular Weight | 149.22 g/mol |
| Buffer Ph Range | 6.5 - 7.5 |
| Appearance | Clear, colorless liquid |
| Density | 0.99 g/mL at 25°C |
| Storage Temperature | Room temperature (RT) |
| Cas Number | 5204-74-0 |
| Solubility | Miscible with water |
| Application | Used in HPLC and mass spectrometry |
As an accredited Triethylammonium Acetate Buffer factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Triethylammonium Acetate Buffer (1 L) from Sigma Aldrich/Merck/TCI Chemical is supplied in a clear, sealed HDPE bottle. |
| Shipping | Triethylammonium Acetate Buffer from Sigma Aldrich/Merck/TCI Chemical is classified as a non-hazardous liquid for shipping. It is typically shipped at ambient temperature in securely sealed containers to prevent leakage or contamination. Packaging complies with international safety standards to ensure safe transit and delivery. Refer to the supplier's SDS for detailed transportation information. |
| Storage | Triethylammonium Acetate Buffer should be stored in a tightly closed container at room temperature, typically between 15–25°C (59–77°F), away from moisture and direct sunlight. Keep it in a well-ventilated area and away from incompatible substances such as strong acids and oxidizers. Ensure proper labeling, and follow Sigma-Aldrich, Merck, or TCI Chemical safety data sheet recommendations. |
Competitive Triethylammonium Acetate Buffer prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Triethylammonium acetate buffer stands as a mainstay in analytical and preparative chemistry thanks to its stable pH range, good volatility, and compatibility with mass spectrometry. As a chemical manufacturer, each batch comes off our reactors with results in mind, born from experience with large-scale liquid-phase synthesis and years of feedback from labs who face real issues of pH drift, baseline interference, and unreliable evaporation.
Labs often find themselves looking for a mobile-phase buffer that can keep up with shifting analytical demands. TEAA (Triethylammonium Acetate) answers that call, especially for ion-pairing chromatography or oligonucleotide separation. We have routinely synthesized and analyzed this buffer through all stages — from the first blend where glacial acetic acid and triethylamine meet, to the precision finalization of molarity measured by titration, to the strictest filtration and bottled purity control.
Oftentimes, teams approach us after cycles of fighting with inconsistent buffers or with the hassles of homemade solutions that fall prey to absorption, contamination, or variable pH. Commercial TEAA, especially when freshly prepared and sealed, delivers something critical: a predictable, reproducible baseline, supporting both low-UV detection and MS compatibility.
From the manufacturing end, the most widely used model we produce is 1.0 M Triethylammonium Acetate, pH set between 7.0 and 7.1 using direct acid-base titration. At this concentration, the buffer stands up to most oligo separations and peptide mapping applications. Demand from customers led us to refine the process so that lot-to-lot consistency holds up whether the lab is working in genomics, proteomics, or pharmaceutical analysis.
Our reactors are equipped for clean, high-throughput synthesis. Final buffer quality relies on two things — raw material purity and process design. We source high-purity triethylamine and glacial acetic acid, then blend under nitrogen to suppress atmospheric uptake of water and carbon dioxide. Filtration, bottling, and quality verification proceed under closed, validated conditions. Each drum, carboy, or bottle gets checked for color, clarity, pH, and UV transparency before shipping. Teams in fast-paced labs don’t have time for second-guessing their buffer lot, and our direct production allows for full traceability and rapid technical support.
Demand for Triethylammonium Acetate has grown alongside the drive for more sensitive, more reliable nucleic acid sequencing and oligo purification. In our experience, customers using capillary electrophoresis, ion-pairing HPLC, or LC-MS for RNA or DNA often need a buffer that will both stabilize pH and volatilize fully during the analysis. TEAA fits here: it combines buffering strength in the neutral to slightly basic range with volatility for mass-sensitive detectors, so it clears out post-run without leaving non-volatile salts to crash the system.
Certain properties distinguish TEAA in these workflows. Its volatility means less buildup on ion sources, prolonging uptime and cutting back on routine instrument cleaning. Compared to phosphate or borate buffers, which can stick stubbornly in LC-MS plumbing or foul detectors, TEAA offers a straightforward clean-out and reliable baselines for sensitive UV or MS detection.
We’ve worked with labs aiming to purify synthetic oligonucleotides or analyze ribonucleotides — settings where each microgram counts and sample carryover must be minimized. Triethylammonium Acetate’s compatibility reduces background noise and cuts down on ghost peaks, improving data sharpness. Lab teams report smoother sequence reads and more reproducible data, especially when they require consistent buffer strength and lot reproducibility over extended programs.
Years on the manufacturing side have taught us that not all buffers are created equal, and not every system is compatible with every solution. Phosphate buffers, a common alternative, offer buffering capacity in some ranges but lack volatility — leaving behind residues that can degrade multi-user instrument performance. Ammonium acetate and ammonium formate provide volatility but lack the ion-pairing strength needed to retain and resolve nucleic acids and larger peptides with subtle charge differences.
In direct use, TEAA’s higher molar mass and amine-based structure give it edge in forming stable ion pairs. This matters with longer or heavily charged sequences that require stronger retention or sharper elution profiles on C18 or reverse-phase resins. Even small changes in counterion strength can shift resolution and result in peak loss or misidentification. Over years of production, we have tuned our formulations to ensure no excess free acid or amine remains after blending, because such byproducts can throw off detector linearity or suppress ion counts in MS.
Cost and supply stability matter to high-throughput labs. Because we control every aspect of our process — from bulk raw material acceptance testing, through real-time reaction monitoring, to triple-tested QC release — our manufacturing plant can supply volume without sudden price spikes or unpredictable shortages. Other vendors who simply re-bottle or re-label third-party intermediates can’t provide this security of supply. We’ve seen firsthand the impact these disruptions have on customers’ project timelines and published outputs. Our direct line to raw material suppliers and large-volume inventory lets us smooth these bumps before they hit the end user.
In our years supporting R&D and manufacturing customers, challenges around buffer selection rarely revolve around just one property. Labs often try to do more with less — maximizing instrument uptime, cutting cleaning cycles, and stretching budgets without losing data quality. TEAA supports these efforts by providing reproducible, stable buffering over a usefully broad pH window, while the volatile profile keeps systems running cleaner and simplifies post-run maintenance.
Instrument downtime caused by non-volatile salt precipitation or unexpected pH increases drives many requests to our technical team. In poorly ventilated LC-MS systems, the residual buffer can bake onto sensitive parts of the mass spectrometer, increasing carryover, throwing off calibration, and degrading high-resolution detections. TEAA’s volatility allows it to clear these lines more efficiently; techs report fewer interventions and lower background after switching from phosphate-based buffers.
Some customers ask about the buffer’s effect on synthetic oligonucleotide deprotection or desalting steps. We found in lab tests and pilot runs that TEAA’s volatile organoamine counterion leaves behind fewer chemical scars in mass spectra, making it easier to identify modified bases and sequence impurities. Feedback from genomics and biotech researchers showed higher throughput as a result, and fewer failed runs traced back to buffer contamination.
Another real headache users report concerns lot variation, which is sometimes invisible until weeks or months later, when inconsistencies in QC data or sequence chromatograms begin to emerge. Our strict in-house synthesis controls, from source testing to batch archiving, let us guarantee traceability back to every drum of acid, every shipment of amine, and each filtering run. For critical applications, labs receive certificates of analysis showing pH, UV absorbance (no interfering absorbers at 260 nm and 280 nm), and metal content, as these can affect nucleic acid detection thresholds in highly sensitive work.
No comment on buffer manufacture can overlook chemical safety. Triethylamine is notorious for its odor and volatility, and acetic acid brings its own hazards. Training matter-of-factly incorporates these realities into every batch produced — full PPE, local exhaust, real-time vapor containment, and frequent air monitoring. Process engineering tweaks, such as temperature control during mixing and pressure relief during blending, reduce both product contamination and workplace risk.
By controlling these on the factory floor, labs down the supply line benefit from safer, more consistent product — fewer aberrant fumes on opening, minimized evaporation loss, and a stable working concentration week after week. Even packaging counts: vibration- and pressure-tested high-density bottles with tamper seals and light-protected drums for sensitive warehouse environments play their role. We field regular requests from customers who’ve had to reject off-the-shelf buffer for poor seal integrity or deterioration in color and pH.
Manufacturers see challenges on both cost and compliance. Each drum has to meet internal specs for potential leachables, pyrogen content, and trace metal background, because end users are pushing detection to ever finer limits. Our QC group uses ICP-MS and HPLC-UV to check every lot before release — not just a random subset, but every scheduled shipment. For labs working on regulated applications in pharma or clinical diagnostics, this safeguards their own compliance pipeline.
Triethylammonium acetate, given its volatility and breakdown products, presents fewer enduring environmental risks compared to some legacy buffers. Still, the process generates waste streams of near-neutral organics and spent rinse water. Manufacturing at scale, we developed closed-loop solvent recovery systems and filter press lines to isolate usable product with minimal discharge. This didn’t happen overnight — continuous investments in process monitoring, buffer crystallization techniques, and efficient reactor cleaning all cut down on volumetric loss and consigned waste.
Customers working in green chemistry or sustainability-driven programs ask about the buffer’s lifecycle footprint. TEAA can be neutralized and degraded in standard facility waste streams, with no accumulation of problematic heavy metals or halides. We document solvent and water balances for contract clients needing environmental audits, and shift packaging toward returnable drums for those trying to cut downstream plastic accumulation.
Engineers and chemists on our team keep an ear out for emerging techniques in nucleic acid and peptide analysis. Clients moving into high-resolution capillary electrophoresis or hybrid LC-MS workflows sometimes experiment with new buffer blends. We collaborate with researchers to test pilot runs, analyze buffer impact on chromatogram shape, and adapt our manufacturing for scaled-up needs — helping streamline workflows from microliter pilot to kiloliter process, always backed by batch data.
In genomics R&D, the need for lot-to-lot consistency really bites during high-throughput screening. Batch data backs every bottle, giving teams the confidence to run parallel experiments spanning weeks or months with no buffer-induced drift. Oligonucleotide contract manufacturers favor TEAA for its high solubility and easy evaporation — two requirements that drive both purification yield and downstream sample prep in their hands.
We’ve fielded requests to tune buffer pH outside the typical neutral range for applications in small-molecule separations or non-aqueous HPLC. The flex in our synthesis allows for these special orders, always respecting the requirement for high purity and volatility. Rather than handing off to toll blenders or generic third parties, our plant manages these specialty runs in-house, ensuring the direct accountability customers require for GMP and regulated work.
Unlike secondary suppliers, we operate our own reactors. We see every production run from start to finish, and understand the chemistry inside and out — raw input, intermediate monitoring, final blend, and packaging. The result is a buffer that gives researchers something real: security about their experimental baselines and clarity for their data.
For many applications, the difference between direct manufacturing and mere rebottling has become clear when customers needed technical support, lot records, or troubleshooting advice. Our team can answer questions about trace components, blending order, or process gas exposure. We’ve found that direct communication between our production chemists and the end-user lab leads to faster solutions when problems crop up.
In our operations, each improvement starts from problems noticed by real-world users. Recent tweaks — from improved nitrogen blanketing to better automation in pH adjustment — reduce lot drift and help boost throughput. Operator experience forms the backbone of safety and quality: seasoned plant techs spot a stray odor or off-color and halt production rather than ship something less than perfect.
Professional pride keeps our standards up. Every step, from the first drum of acid accepted at receiving to the final QC sign-off, passes through hands with decades of combined experience. We take satisfaction in seeing our product help labs achieve cleaner baseline separations, longer instrument uptime, and tighter chromatogram profiles. There’s no hiding behind branding or remote supply lines — our reputation rides on every pail shipped, every phone call answered.
No off-the-shelf description can replace direct experience in making buffers at scale. Our customers gain the assurance that their buffer was blended in dedicated reactors, QC’d by in-house chemists, and shipped directly from the plant floor. If a customer needs record traces of pH drift or minor component background, we can trace it back to a source drum, a process valve, and an operator’s initials on a batch record.
Labs that move from generic or relabeled sources often report improvements in data reproducibility and less day-to-day troubleshooting. TEAA’s volatile and amine-strength properties continue to find new uses as genomics, sequencing, and biopharma research pushes forward. More applications, more analysis — each depends on buffers that don’t leave behind uncertainty.
We see the changing needs and higher expectations in modern chemical analysis, and our focus as a manufacturer remains clear: keep quality at the source, own the process, support the user, and never cut corners for speed or cost. In the end, the value of a buffer like Triethylammonium Acetate comes down to giving scientists the confidence to trust their results — every run, every time.