|
HS Code |
829335 |
| Product Name | Tetrabutylammonium Hydroxide (10% in Methanol) [for non-aqueous titration] |
| Chemical Formula | C16H37NO (aq) in CH3OH |
| Concentration | 10% (w/w) in methanol |
| Appearance | Clear, colorless to pale yellow liquid |
| Molecular Weight | 259.48 g/mol (TBAOH) |
| Density | Approx. 0.90-0.92 g/cm³ |
| Solvent | Methanol |
| Common Use | Non-aqueous titration |
| Boiling Point | Methanol: 64.7°C |
| Storage Temperature | 2-8°C (refrigerated) |
| Ph | Strongly basic |
| Hazard Classification | Flammable, corrosive |
| Cas Number | 2052-49-5 (TBAOH), 67-56-1 (Methanol) |
| Shelf Life | Typically 12-24 months |
| Grade | Analytical reagent |
As an accredited Tetrabutylammonium Hydroxide (10% in Methanol) [for non-aqueous titration] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 500 mL amber glass bottle, secure screw cap, labeled with chemical name, concentration, safety warnings, and manufacturer (Sigma-Aldrich/TCI). |
| Shipping | Tetrabutylammonium Hydroxide (10% in Methanol) is shipped as a hazardous chemical due to its flammability and corrosive properties. Packaging complies with regulatory standards, ensuring secure containment. Shipping includes appropriate labeling and documentation for safe handling. Only certified carriers and trained personnel manage transportation, in accordance with relevant chemical transport regulations. |
| Storage | Tetrabutylammonium Hydroxide (10% in Methanol) should be stored tightly sealed in a cool, dry, and well-ventilated area, away from heat, sparks, open flames, and incompatible substances such as acids and oxidizers. Store at temperatures between 2–8°C, protected from moisture and direct sunlight. Proper chemical storage cabinets, especially for flammables and corrosives, are strongly recommended. |
Competitive Tetrabutylammonium Hydroxide (10% in Methanol) [for non-aqueous titration] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Titration work in non-aqueous systems often puts typical reagents to the test, especially whenever water presence distorts results or the analyte resists standard conditions. Our Tetrabutylammonium Hydroxide (TBAOH) in 10% methanol consistently proves itself in these labs because it acts as a reliable strong base, offering clarity through its unique chemical stability in solvents where water-based alkalinity won’t perform the same job. We observed that many chemists start with classic aqueous sodium or potassium hydroxides and rapidly run into challenges with decomposition, unpredictable behavior, or interference from even minute traces of water. Switching to TBAOH in methanol reduces these risks. Our teams have refined the dissolution in high-purity methanol, which preserves reagent strength and suppresses trace moisture—a major win for the sort of precision that non-aqueous titration requires.
Experience drives every decision we make during the production of TBAOH solution. Preparing a stable, homogeneous solution has taken years of investment in closed-transfer systems, glass lining, and rigorous inert gas protection from start to finish. Our process skips shortcuts; we combine vacuum-dried TBAOH salt with anhydrous methanol in jacketed vessels, controlling exothermicity and avoiding contamination by the atmosphere. Each batch depends on fresh solvent and real-time Karl Fischer titration to verify water content; the target sits at under 0.05%, and routine actual results come in even lower. Small details—fresh seals, individual containers, and direct-from-reactor bulk transfers—mean the solution never absorbs environmental moisture before it reaches the client. This is a far cry from diluted aqueous grades, which suffer from short shelf life and stability drift.
The most commonly requested preparation holds precisely 10% TBAOH by weight in high-purity methanol—this balance delivers a standard normality (approximately 0.80 to 0.85 N base strength), favored for its universal applicability in titration protocols. Overfilling a titration with excess base brings just as many problems as using too little; the margin between overdiluted and excessively strong solution becomes narrow in tricky determinations like weak acids or drugs analyzed outside the aqueous phase. This grade is manufactured to a tight specification for both TBAOH content and methanol quality, eliminating parasites such as aldehydes or ketones that would sabotage indicator response. Our internal QA experience shows that titration end points rely on crisp, unambiguous color transitions—trace impurities can easily cause tailing or delayed signal. By managing our supply chain from quaternization right through bottling, we guarantee reliable, batch-to-batch reproducibility. That level of consistency rarely comes from resellers or suppliers dabbling in contract batches.
Our customers come from pharmaceutical R&D, analytical service labs, teaching universities, agrochemical companies, polymer suppliers, and beyond. Still, the most frequent feedback focuses on how TBAOH in methanol speeds up and clarifies endpoint detection in non-aqueous acid-base titrations. Pharmacopeia protocols for substances like fatty acids, certain weakly acidic APIs, and specialty monomers call for TBAOH rather than inorganic alkali, because the quaternary ammonium ion interacts less with complex organic matrices and gives cleaner titration curves. In one real-world example, an industrial client tired of drift-prone titration curves using KOH in ethanol reported steady, sharp endpoints after shifting to our TBAOH 10% solution. The difference carried through into their regulatory submissions, where data reproducibility proved critical.
TBAOH offers another degree of flexibility for those developing new titration methods. It operates with a wider selection of indicators when compared against the limited choices compatible with excess moisture or ionic precipitation. Our technical support teams have worked on projects ranging from acrylate and epoxy resin characterization to analysis of detergents and specialty surfactant blends, where water would induce phase splitting or irreversibly muddle the reaction. It’s not just about neutrality—the tetrabutylammonium cation is large, lipophilic, and generally unreactive toward most analyte backbones, which keeps pH changes straightforward and minimizes the risk of side product formation.
Methanol as a solvent also offers clear advantages. It boils at a manageable temperature, purges off after analysis without persistent residue, and keeps titrant and titratable compounds uniform throughout the test. Both large reactors and microscale titration vessels benefit from this homogeneity. In environmental analysis, especially for weakly acidic or multi-functional organic acids, the methanol matrix reduces random scattering and phase interference observed in aqueous systems.
It’s tempting to compare any titration base simply on strength, but routine lab work shows the differences that matter emerge through operational details and unexpected chemical quirks. Aqueous sodium or potassium hydroxide, for example, works beautifully in traditional acid-base titrations—until moisture mistakes or solvent incompatibilities derail high-stakes tests. TBAOH in methanol enters on the strength of its water-excluded protocol. By staying uncompromised by atmospheric uptake, sample hydrolysis, or rapid degradation, each batch remains potent and consistent longer than typical aqueous titrants can manage on the bench.
Other quaternary ammonium hydroxide formulations exist on the market, including mixtures in ethanol or 40% aqueous solution, but these alternatives don’t provide the same balance of volatility, titrant clarity, and outcome control. Ethanol options appeal to some workflows, though methanol’s shorter carbon chain and lower boiling point lend it higher solubility and cleaner post-titration evaporation, especially important in residue-sensitive applications like food chemistry or environmental forensics. Our production teams observe less batch separation and better end-use handling at 10% concentration in methanol than at higher or lower concentrations in alternate carriers. Bulk clients producing high-throughput analytical results find that stability translates directly into time savings—once prepped and standardized, these solutions can survive weeks in use without re-titration, as long as basic handling precautions are followed.
The other edge comes from purity and the absence of inorganics. In contrast to metallic hydroxide titrants, tetrabutylammonium solutions produce only organic reaction byproducts and avoid precipitation or scaling on glassware. Several of our pharmaceutical and biotech partners appreciate the low-metal background because their analytes and titration products pass directly into process steps sensitive to sodium, potassium, or calcium contamination. Water-miscible titration products make downstream separation and analytics much easier than ionic chlorides or sulfates.
Few chemical manufacturers devote full systems and dedicated staff to products like TBAOH in methanol, but our experience points to unique challenges that indirect suppliers rarely tackle. Each container ships direct from one of a handful of isolated filling lines. We treat every tank, drum, or bottle as a controlled lot, connected to its source reactor by traceable documentation and digital QC logs that our customers are welcome to inspect as part of their validation workflow. Incoming feedback from analytical customers drives incremental tightening of limits—whether that means thinner filtration, triple vacuum rinsing, or single-lot expiry assignments. This close-loop approach avoids cross-taint from broader product lines or storage periods, keeping our reagents suitable for compliance-driven environments. We’ve learned that variation in titrant strength, even tiny drift over a week or two, can wreck trust and generate more wasted time recalibrating standard curves than the cost of using the highest quality prep.
Freshness turns out to matter as much as nominal purity. Laboratory customers report that freshly made TBAOH in methanol sparks sharper endpoints, gives fewer borderline readings, and streamlines QA signoff. While some competitors deal in months-old, warehouse-stored inventory, we align our runs to direct sales or standing framework contracts with lean inventory cycles—meaning nobody waits out shelf time. This is one of the ingredients in the user’s sense of confidence and repeatability.
Handling safety and regulatory compliance also play daily roles. TBAOH solutions in methanol, unlike lower-grade aqueous alkali, demand accurate hazard communication and careful packaging: every batch moves in fluorinated high-density polyethylene, capped with vapor-tight seals and tamper-evident assurance. Our staff have trained for spill avoidance, reactive cleanup, and documentation in tandem with customer protocols—nobody likes surprises with high-purity, hygroscopic chemistry.
We never lose sight of the fact that most users of TBAOH in methanol stake their name and their company’s reputation on transparent, reproducible results. A well-made non-aqueous titration solution delivers not just endpoint color but statistical confidence and regulatory credibility to every analysis. This expectation drives our continuous feedback loop: reports of residue, slow indicator response, or sample blank creep come straight to our technical review and can become development projects. Several titration chemists at analytical contract labs have sent us titration runs with full endpoint curves, so we can jointly pinpoint drift or impurity impact. This direct manufacturer-user relationship avoids the time sink and quality drift of relying on generic or batch-mixed alternatives.
In the field, TBAOH 10% in methanol supports critical work—pharmaceutical release testing, food and oil analysis, specialty monomer QA, and more—because the entire supply chain, from raw materials to vial capping, tracks toward accuracy and robust performance. Our decades of insight lead to supporting advanced titration indicators, custom concentrations for innovation, and deep-dive methodologies that help solve real analytical challenges.
Fragile chemical bases with rigorous application requirements test the limits of just-in-time production and require persistent vigilance over distribution. We have encountered global challenges in raw TBAOH component consistency; to counter this, we requalify each salt lot and simultaneously run parallel test dissolutions. Any deviation in water content or side reactions results in immediate lot withdrawal and feedback to the logistics division. Our in-house logistics group guards bottles during weather extremes, shipping only in climate-controlled packaging at every season, particularly in sensitive or tropical export routes.
Once, during an unexpected port delay, a subtropical import customer encountered a drum whose seal failed to hold after three weeks in a humid warehouse. Our operational response meant airfreighting a replacement at our expense and redesigning the container venting for all future shipments. These lessons shape the feedback loop that keeps reliability real, not aspirational.
Day in and day out, we draw on direct manufacturing experience to adjust, improve, and guarantee every can, drum, or ampule of TBAOH in methanol. Not every “available” option on the market gets built under these conditions, because few third-parties have enough control over solvents, batch timing, or purity checkpoints. Repeat analytical results mean something only when the exact chemistry matches every time. Whether it's avoiding microgram-scale impurities or adapting container size for mega-labs or small boutiques, all insight starts at the reactor and extends to each tightly sealed shipment.
Reliability isn’t luck—it comes from technical teams logging thousands of batch hours, investing in traceable raw materials, and knowing non-aqueous titration not just as theory but as workplace routine. From precise filling tools to analytical service partnerships for test comparison, our approach ensures researchers, analysts, and QA officers see the same results today as they saw last year and last quarter. That performance edge takes long-term knowledge and real-time effort.
As users demand stricter titration windows, lower detection limits, and greener process footprints, TBAOH in methanol adapts. Our chemists continually monitor trends in new indicator chemistries and compliance standards—moving quickly to adapt our solution’s compatibility and labeling. Although methanol raises flammability and tox control flags, analytical performance calls for it more often than lower-performing ethanol-based mixes, and we respond with full MSDS, documentation, and onsite training as needed.
Laboratories searching for replacement titrants in new product development, stability testing, or custom protocol validation often approach us with non-standard requests: tailored normalities, scope for alternate solvents, or paired indicator supply. These partnerships have led to several peer-reviewed publications and off-label method adoptions, supported by rigorous batch data and direct manufacturer-lab communication.
Confidence in TBAOH 10% in methanol, from a chemical manufacturer’s perspective, comes from hard-won expertise and genuine investment in process reliability. We pay close attention to industry changes, customer feedback, and on-the-ground analytical results. Every bottle tells a story of iterative improvement and hands-on experience—never just label swapping or passive reselling. As titration challenges shift and endpoints get sharper, only a focused, original manufacturer with full process control can engineer the sort of solution that keeps scientific progress moving forward without compromise.