West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Tetrabutylammonium Hydrogen Sulfate [Reagent for Ion-Pair Chromatography]

    • Product Name Tetrabutylammonium Hydrogen Sulfate [Reagent for Ion-Pair Chromatography]
    • Alias TBAHS
    • Einecs 248-251-1
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    673692

    Product Name Tetrabutylammonium Hydrogen Sulfate
    Chemical Formula C16H37NO4S
    Molecular Weight 339.54 g/mol
    Cas Number 32503-27-8
    Appearance White to off-white crystalline powder
    Solubility Soluble in water and methanol
    Melting Point 140-144°C (decomposes)
    Purity ≥99.0% (typical for reagent grade)
    Storage Conditions Store at room temperature, in a tightly closed container
    Usage Reagent for ion-pair chromatography

    As an accredited Tetrabutylammonium Hydrogen Sulfate [Reagent for Ion-Pair Chromatography] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The packaging is a white, sealed plastic bottle containing 100 grams of Tetrabutylammonium Hydrogen Sulfate, labeled with product and safety information.
    Shipping Tetrabutylammonium Hydrogen Sulfate (Reagent for Ion-Pair Chromatography) is shipped in tightly sealed containers, protected from moisture and heat. The chemical is classified as non-hazardous, but it should be handled with gloves and eye protection. Ensure transportation complies with relevant regulations for laboratory reagents. Store in a cool, dry place upon receipt.
    Storage Tetrabutylammonium Hydrogen Sulfate should be stored in a tightly closed container, in a cool, dry, well-ventilated area away from heat, moisture, and incompatible substances such as strong oxidizers. Keep the chemical out of direct sunlight and store at room temperature. Ensure proper labeling and follow laboratory safety protocols when handling or storing this reagent for ion-pair chromatography.
    Free Quote

    Competitive Tetrabutylammonium Hydrogen Sulfate [Reagent for Ion-Pair Chromatography] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Tetrabutylammonium Hydrogen Sulfate: Supporting Reliable Ion-Pair Chromatography

    Direct from the Manufacturer: Chemical Quality by Design

    Every time a laboratory technician sets up an ion-pair chromatography analysis, the chemicals behind the scenes matter. In our own production of Tetrabutylammonium Hydrogen Sulfate, we balance consistency, purity, and traceability with an eye on the final chromatographic separation. Years of synthesis experience have taught us that without full control over our process, even a minor impurity can interfere with retention times or load unwanted peaks onto a baseline.

    Inside our facility, we manufacture Tetrabutylammonium Hydrogen Sulfate with model offering at ≥99.0% purity, as independently verified through titration and chromatography-grade testing. We’ve seen how small variations in cation or anion content change retention factor reproducibility. That’s one area where bulk-sourced or untested material fails. Instead, our finished batches feature clear labeling with batch traceability, and every drum brings a certificate linked to in-house QC data.

    Why Purity Makes a Visible Difference

    Reagent-grade means different things to different suppliers. Manufacturing at source lets us guarantee residue thresholds, heavy metal content, and organic byproduct controls that traders rarely even test. In our own lab-run applications, we’ve traced shifts in chromatographic selectivity back to contamination levels below 0.1%. That’s why our technical team scrutinizes each production step — drying, recrystallization, and final vacuum packaging all receive special attention. Our production pathway uses high-purity butanol and ammonia, followed by careful acid addition, removing water and organic byproducts in a sequence derived from actual customer feedback.

    Compared to standard commercial salts, our product’s transparent crystals dissolve easily in water and organic solvent systems. We do not add anti-caking agents or bulking materials, which can introduce unknowns into sensitive eluents. Often, chromatographers encounter unexplained ghost peaks or fluctuating detector signals when switching from lab-scale bottles to drums of undifferentiated material. With direct manufacturing control, end-users avoid this scenario and keep their calibration curves valid over large sample sets.

    Built for Demanding Applications

    Ion-pairing reagents like Tetrabutylammonium Hydrogen Sulfate allow reversed-phase HPLC and other chromatographic workflows to analyze ionic compounds. Across the pharmaceutical, food, and environmental sectors, analysts confront separation roadblocks where standard C18 columns lose effectiveness. Ion-pair chromatography bridges that gap by pairing sample ions with an organic counterion — our product — giving both neutral and charged analytes the right selectivity window.

    Clients in generics manufacturing, pesticide residue analysis, and even battery research specify our reagent because they need low-UV cutoff, strong retention, and fast dissolution. Many also demand clear documentation; our analytical support staff conduct on-request NMR and FTIR characterization for every lot above 25 kg, tying actual performance to manufacturing records.

    We’ve noticed that labs switching from basic-grade to our manufacturer-direct material report sharper peak resolution and lower system pressure buildup. Our sulfate ion source dissolves without haze or insoluble debris, so filter columns and detector optics run longer between cleanings. Throughout our years selling both drum and bottle packaging, rejects for physical appearance or solubility come in at less than 0.05%. If a user ever reports a handling defect, we walk through the process and replace stock from the same parent batch. This kind of technical partnership only happens when you know the lot history all the way back to synthesis.

    Specifications That Shape Outcomes

    By overseeing every kilogram from synthesis to dispatch, we maintain reliable product specifications. The assay purity stays above 99% by titration with potentiometric endpoint confirmation. Water content in final batches rarely exceeds 0.5%, and chloride contamination is typically undetectable by silver nitrate methods. Fresh drums feature sealed liners and reinforced lids to prevent ambient air or water vapor ingress, which we monitor throughout storing and shipping.

    We produce both standard and high-purity product lines to address different chromatography demands. For isocratic or gradient ion-pair separations at trace levels, our premium batches undergo additional filtration and vacuum packing, verified by LC-MS contamination screening. Standard models comfortably meet analytical and preparative separations for routine QC and batch-release testing. All lots come with actual assay values, so rather than listed minimums or averages, users calibrate preparation exactly for their needs.

    A side-by-side performance comparison reveals where specifications matter. Our high-purity Tetrabutylammonium Hydrogen Sulfate keeps background absorbance below 210 nm, so those working with short-wavelength UV detection don’t mask early eluting peaks. Meanwhile, low sodium content ensures there’s no risk to alkali-sensitive detection systems. Many competitors cut purity by finishing with recycled feedstock or allowing mixed-batch packing. We keep our standard and high-purity lines entirely separate in handling and warehousing.

    Direct Manufacturer Support

    Several of our long-term partners migrated from third-party resellers and now opt for made-to-order lots for method development and validation. This approach allows our technical team to tune batch characteristics such as water content or particle size distribution if needed. From temperature-controlled shipping in humid regions to emergency resupply of 100+ kg drums, we coordinate all steps internally, without relying on intermediaries who often can’t verify chain of custody.

    Clients working in FDA-audited labs have particular documentation needs for traceability and long-term archive. As direct manufacturers, we keep seven years of lot-level records, including raw material trace, process time stamps, and final QC readouts. Emergency support is available from chemists with experience in ion-pair protocol troubleshooting, whether users face error spikes, sticky columns, or eluent incompatibilities.

    It’s common for researchers to adjust mobile phase composition during scale-up or process validation. Our team shares batch-specific dissolution curves and helps optimize preparation so the transition from method development to large-batch manufacturing proceeds with no surprises. Where special packaging or assurance against cross-contamination is needed — for example in regulated pharmaceutical settings — we custom-pack fresh batches under bias-free cleanroom conditions.

    Understanding What Distinguishes Our Tetrabutylammonium Hydrogen Sulfate

    Making the transition from bulk chemical supplier to manufacturer has set our product apart in several practical ways. Our synthesis uses only high-purity amines and inorganic acids, with closed-system reactors that minimize environmental exposure. Each batch is sampled at multiple production points then signed off before any packaging, not after. For us, that means defects get caught early, and no one downstream faces off-spec stock.

    We avoid magnesium and calcium contamination by using glass-lined equipment and routinely check finished salts for these metals with ICP-MS. Not all suppliers invest in such controls, and we’ve reviewed industry feedback pointing to spurious peaks caused by trace alkali. Control of byproducts like butyl sulfate and non-ionic surfactants is another strict focus. Our own staff have experienced columns failing prematurely when exposed to off-brand alternatives, leading to costly downtime and repeated cleaning cycles.

    For those handling regulatory filings or method transfers, our QC reports feature original chromatograms and analyst signoffs, not just summary tables. Any request for spectral or structural confirmation can be supplied direct from the parent batch, with wet analysis available by independent labs upon request. Cumulative feedback from our clients shows marked reduction in instrument service calls when direct-manufactured reagents replace mixed-batch bulk buys.

    Shipping and Customer Accessibility

    Within our shipping network, we maintain environmental controls, especially for bulk shipments that may face humid or temperature-variable routes. Packaging reflects long shelf-life requirements with five-layer barriers and nitrogen flushes on high-sensitivity orders. We supply drum, can, and bottle formats, with fill weights adjustable for laboratory or pilot-plant scale demand. Whether for local or export shipment, each unit is tracked via internal batch codes, offering recall and root-cause transparency in rare cases of shipping damage.

    Accessibility also means advice on preparation and storage. Our in-house chemists remain available for onboarding customers switching from older stocks or alternative ion-pair reagents. For environmental labs dealing with legacy contaminants, we provide blend recommendations and compatibility charts so transitions don’t disrupt established workflows. Where special dissolution needs are anticipated, we pre-test solubility in standard acetonitrile, methanol, or buffer conditions, delivering an honest assessment — not marketing claims.

    Long-term partners keep ongoing lots in “make to hold” status, so batch-to-batch change is minimized. This helps avoid the need to run fresh system suitability checks with every new delivery, saving instrument time and consumables. It’s a different philosophy from bulk traders, who often treat quality variation as unavoidable or routine.

    Comparative Insight: Beyond the Usual Options

    Much of the academic and industrial market for ion-pair reagents has shifted toward one-size-fits-all solutions, especially where cost reduction drives procurement. Risk appears with every step toward lower specification or non-transparent blending. Our manufacturing experience has shown that simply listing purity or mesh size tells little about practical outcome.

    Tetrabutylammonium salts from casual sources create headaches — poorly controlled moisture, non-uniform particle sizing, and leachable impurities all translate to real-world system drift. Column lifetimes, baseline stability, and detector reliability decline faster, sometimes leading to untraceable artifacts that eat up investigation resources. For those who lived through column recalls or method failures tied to substandard reagents, documented origin, purity, and shipping practices become more than a selling point — they are a form of operational insurance.

    Our approach also contrasts in how we engage with method transfer and regulatory support. Global customers face local requirements for heavy metal reporting, residual solvent disclosure, and consistent labeling. We deliver this alongside actual lab data, not templated certificates, so compliance teams run audits with facts that stand up under scrutiny. Repeat customers return thanks to this level of transparency, not simply because of price or fast shipping.

    For more specialized applications in pharma and environmental monitoring, our high-purity batches solve low-level analyte detection without pushing up system baselines. LC-MS users, in particular, benefit from lots screened for matrix effects and background ion suppression. Seeing method reproducibility extended over multi-year studies stands as proof that source-level quality matters more than short-term economies.

    Practical Guidance from Direct Manufacturers

    Switching to a new ion-pair reagent should not unsettle established lab routines. As the producers, we keep our technical and support staff accessible — not as a marketing script, but as colleagues who understand equipment downtime, troubleshooting, and method validation under audit. It’s not unusual for column vendors or instrument companies to reference our batches in performance handbooks, and we keep our protocols transparent so users can replicate results in their own validation or troubleshooting.

    If users encounter baseline drift, incomplete dissolution, or unexpected artifacts, immediate root-cause analysis traces back to the specific batch procedures. Our QC database links finished product to raw material supplier, synthesis route, environmental controls, and individual operator record. This lets us supply more than generic troubleshooting scripts; we provide tailored response and, if required, custom-make a run that aligns with the customer’s application, not just our own convenience.

    Real-world experience also impacts our packaging and fulfillment priorities. Chemists who use our reagents every day recommend design changes, like smaller necks on bottles to minimize ambient moisture, or opaque, UV-resistant drums for overseas shipping. We pilot these in our own labs and adjust based on durability and ease of use. Every modification comes from actual end-user feedback, not just supplier convenience.

    Several large-volume buyers collaborate on shared technical projects, often requesting pre-packed ready-to-use solutions or co-delivery with other critical reagents. By handling all aspects of the supply directly, we can coordinate production and shipment without the inconsistencies that come from changing hands between intermediaries, consolidators, or border agents.

    Continuing Commitment to Science and Accuracy

    Years spent manufacturing, testing, and supporting Tetrabutylammonium Hydrogen Sulfate means we understand both the theory and the day-to-day pressures faced by analysts. In speaking with users, we know it matters less what the reagent achieves on paper than how it performs in the field — clean baseline, reliable dissolution, stable signal, and predictable retention. Our ongoing investment in facilities and staff training anchors every lot we ship to the values of reproducibility and data integrity.

    Sourcing direct from the manufacturing floor, rather than a generic warehouse, means clients stay in full command of their analytical outcomes. We stand ready to keep Tetrabutylammonium Hydrogen Sulfate at its highest grade and to support users through any questions, variation, or technical demands that arise. A robust product isn’t born from a catalog description — it comes from the investment in people, practice, and process that start at synthesis and carry through to the customer’s benchtop.