| Product Name | (S)-(+)-DBD-APy |
| Chemical Name | (S)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole |
| Synonyms | DBD-APy, HPLC Labeling Reagent |
| Cas Number | 1249849-40-2 |
| Molecular Formula | C13H18N4O3S |
| Molecular Weight | 326.37 g/mol |
| Appearance | Light yellow powder |
| Purity | Typically ≥98% |
| Application | HPLC derivatization reagent for chiral amino acid analysis |
| Solubility | Soluble in DMSO, Methanol, and Acetonitrile |
| Storage Conditions | Store at -20°C, protected from light and moisture |
| Optical Activity | Specific rotation [α]D25 +45 to +55 (c=1, MeOH) |
| Excitation Maximum | 425 nm |
| Emission Maximum | 545 nm |
As an accredited (S)-(+)-DBD-APy [=(S)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent fore.e.Determination] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging is a 10 mg amber glass vial with a screw cap, labeled with chemical name, CAS, lot number, and hazard information. |
| Shipping | Shipping for (S)-(+)-DBD-APy [(S)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] is typically conducted under ambient or cool conditions, protected from light and moisture. The packaging is secure, compliant with chemical transport regulations, and includes all necessary documentation for laboratory use from Sigma Aldrich, Merck, or TCI. |
| Storage | (S)-(+)-DBD-APy should be stored in a tightly sealed container at 2–8°C, protected from light and moisture to prevent degradation. The chemical must be kept in a well-ventilated, dry area and away from incompatible substances. Use only in a chemical fume hood, and ensure proper labeling. Follow Sigma-Aldrich, Merck, or TCI safety guidelines for handling and disposal. |
Competitive (S)-(+)-DBD-APy [=(S)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent fore.e.Determination] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Producing (S)-(+)-DBD-APy has always involved plenty of consideration, not just for purity but for process reliability. Our chemists have worked with this molecule from its early days. From raw starting materials to the final crystalline powder, careful control of moisture and light sensitivity during synthesis and packing preserves both structure and reactivity. In our case, batch records and analytical data travel with the product, not just on paper but through practical methods and hands-on inspection. We take measurable pride in consistently hitting >98% purity by HPLC, because, down the line, a minor contaminant during labeling can throw off months of analytical work for the researcher.
In the lab, (S)-(+)-DBD-APy looks like a canary yellow solid, ready to react with primary and secondary amines in aqueous or organic solvent. We designed the particle size and surface area for rapid dissolution, which serves both synthetic chemists and analysts aiming for quantitation at the sub-picomole level. This material grew out of our direct dialog with academic and pharmaceutical research groups who needed improved selectivity and better signal-to-noise in their HPLC amino acid assays, especially those using fluorescence detection.
The DBD family has seen a steady evolution since we first made and labeled the simple BODIPY analogs two decades ago. (S)-(+)-DBD-APy introduced the aminopyrrolidine moiety, which gives a sharper, more reliable fluorescence peak and lower background, compared to older dansyl or NDA labeling reagents. This shift comes straight from customer feedback—the old standards sometimes produced multiple labeling products or hydrolyzed too quickly, ruining batch-after-batch of samples. Our synthetic process clamps down on those side products, delivering a cleaner chromatogram, every time. Other labels tend to fall short in complex biological matrices, but this molecule carries a strong signal and avoids cross-talk with natural sample fluorescence, even in plasma, tissue, or fermentation broths.
We still get requests for the older dimethylaminosulfonyl-benzoxadiazole analogs. Many long-time customers stick with those because of habit, even with their limitations. But work done in collaboration with major reference labs convinced a number of them to transition to our current DBD-APy product, once they saw their chromatograms flattening out in the baseline and separating peaks more sharply with smaller injection volumes. Our own internal QC traces tell the same story: brighter fluorescence, less tailing, and fewer ghost peaks. No amount of marketing can beat the effect of a single clean, reproducible trace that cuts sample prep time for a busy analyst or production chemist.
(S)-(+)-DBD-APy is delivered at 25 mg, 100 mg, or 1 g per bottle, sealed under inert argon atmosphere inside a high-barrier vial. The batch number isn't just a formality: it's the means by which a user can access the full synthetic route, final chromatograms, and spectral data. Typical melting point sits above 190 °C, consistent with full cyclization. NMR and elemental analysis confirm structure and optical purity. You can see the difference after reconstitution in MeCN or DMF — the solution turns a uniform, bright yellow at working concentration (0.01–1 mM). UV-visible spectra yield a crisp absorption near 395 nm, while emission peaks favor 530 nm, perfectly matched to most HPLC fluorescence detectors.
Clarity about solubility matters most at the bench. Through multiple R&D cycles, we've seen how poorly dissolved labels can coat HPLC lines and injectors. That's why our product undergoes real-world solubility checks in both acetonitrile and DMSO, which provides reassurance against microcrystallization or sample loss at cold storage. Every batch undergoes actual test labeling against glutamic acid and lysine before release; we won't ship unless the final yield and intensity hit the target.
Questions about stability and storage always arise. We learned the hard way that (S)-(+)-DBD-APy absorbs atmospheric moisture if left open for more than a few minutes. Early on, we fielded more than one phone call about labeling failures due to hydrolyzed reagent. That motivated a strict moisture-protective pack-out and practical guidance to our customers: open only under dry nitrogen, minimize exposure, and recap immediately. Labs that followed our advice reported a dramatic drop in failures.
It's this kind of experience that leads us to reject "neutral" claims about shelf life; the method of storage has the final say. We've seen two-year-old, properly stored material label samples flawlessly, while a poorly recapped vial can fail after a month. We keep reserves from all major lot numbers at –20°C as a hedge, and can supply reference samples for troubleshooting on customer request. Our own analytical chemists routinely pull vials from cold storage and compare results to fresh runs, giving a plain measure of robustness.
Many so-called "labeling reagents" on the bulk market claim high purity or low costs. From our plant-floor perspective, those numbers mean little without thorough batch validation against intended application. Some manufacturers pool lots to smooth over purity fluctuations. We separate batches aggressively, discarding material that fails either in pre-labeling test reactions or secondary fluorescence checks. Our in-house validation includes real HPLC runs against complex matrices—never just inert standards—because those are the samples researchers work with in real practice.
Common analogs like dansyl chloride and NDA have dominated the market for decades, but their day is passing. These older reagents drift in fluorescent response, forcing analysts to repeat runs or tolerate false positives. Their side-chain reactivities make interpretation difficult, especially for unknowns or modified amino acids. We saw these frustrations up close as synthetic chemists; the smallest change in sample pH or buffer could throw out retention time or introduce unexpected label artifacts. With (S)-(+)-DBD-APy, the chemistry has enough selectivity that even less-experienced users pull high-quality chromatograms without extensive method development.
Analytical chemists working in biochemistry or pharmacology care less about supplier claims and more about reduction in hands-on troubleshooting. We developed our labeling reagent in direct response to those demands. Simple workflows matter. Our product dissolves smoothly without the need for sonication or prolonged stirring. Derivatization finishes in under 10 minutes at room temperature, where alternatives often take hours or lose yield unless carefully heated. We replaced complicated activation steps with a single pipetting operation, minimizing time under open air.
Customers often call for troubleshooting, and we rarely see failures once the process has been established: weigh the solid, dissolve in your chosen solvent, label the sample, clean up by SPE or filtration, and go straight to the autosampler vial. Products with less robust handling—especially those shipped with loose or ambiguous paperwork—leave chemists with unanswered questions and burned samples. We know because our technical staff has handled more than one emergency replacement, learning and correcting in each case.
Our product features prominently in publications across peptide characterization, metabolomics, and trace amine quantification. Leading labs—especially those pioneering approaches to minimal sample volumes—regularly cite (S)-(+)-DBD-APy for its utility in working at the femtomole and attomole regime. That only became possible with commitment to scale-up under precisely the same conditions as analytical lots. Our process does not cut corners, and the result is a reagent that meets the technical needs of both small academic labs and major pharmaceutical sites.
We respond directly to custom requests, adapting formulation, aliquot size, or packaging style for users with extreme throughput demands or in regulated environments. For those scaling up HPLC or LC-MS workflows, we include expanded documentation—detailing everything from trace metal content to residual solvent analysis. That level of transparency keeps labs compliant and confident, even under audit conditions.
Every specification in our data package sits on a foundation built from long hours and real mistakes, not desk-drawn tables. We have seen how a single variable—overdrying, underpurifying, mislabeling—can destroy a batch and months of effort. Because we supply directly from synthesis, we cut out the confusion of untraceable third-party origins and guarantee a straight answer for each technical question.
Quality assurance for (S)-(+)-DBD-APy means more than HPLC purity and melting point; it includes reference chromatograms with both trivial and highly complex samples. Our team includes former bench researchers who have transitioned into process and QA roles, so the language in our COA and instruction material makes sense for real laboratory workflows, not just regulatory review. Any anomalies, such as slight color changes or changed solubility, prompt an immediate QA hold and retesting on our own benches. We don't shy away from direct phone calls or detailed troubleshooting, knowing that a supplier who listens ends up learning more than one who hides behind standard answers.
Handling fluorescent sulfonamide derivatives brings up EHS concerns, which we have mitigated by limiting dust generation in packaging and using sealed automation for larger batch sizes. Routine monitoring of production air counters overexposures, while the final packaged vials include tamper-evident closure. Real-world feedback from users—concerns about skin or eye irritation—prompted us to include gloves and simple warning instructions with each first-time purchase. We overhauled solvent handling to prevent carryover of DMF or dichloromethane, relying on greener alternatives where possible in washing steps.
Waste from labeling reactions often ends up in the aqueous stream. Following several university pilot studies, we optimized our own method for Fenton treatment that achieves full destruction of both chromophore and amine residues before discharge. We share this protocol with customers looking to enhance their own waste stream management. Safety is not a sticker on the box for us—it’s part of what the operator at our facility experiences daily and translates into the guidance and support we provide end-users.
Changes in analytical chemistry demand not only better tools, but also adaptable suppliers. As new equipment and robotics enter the workflow, (S)-(+)-DBD-APy serves as a model for plug-and-play labeling in both automation and hands-on protocols. We prioritize lot-to-lot reproducibility, so users running high-throughput or field-deployed systems see no drop-off, regardless of shipment date. This isn’t just about chemistry—the growing push for greener, less resource-intensive procedures is something we accommodate by developing lower-toxicity derivative reagents and supporting requests for recyclable packaging.
Data integrity sits at the core. We track each batch with a digital trace that can survive through any LIMS or regulatory audit. Researchers who need assurance of forensic traceability don’t have to chase down missing links—every transaction, analysis, and shipment gets archived for future reference. Informed by experience, not guesswork, our approach guarantees support from first inquiry through to result validation.
Manufacturers don’t control the research agenda, but we do shoulder the responsibility when technical innovation runs up against scale, application, or compliance. Serving the scientific community with (S)-(+)-DBD-APy, we draw on owned experience and a direct connection to user feedback, supporting not only sharper bands on a chromatogram or higher detection limits, but also fewer headaches during planning, setup, and analysis. Our story with this reagent is ongoing, shaped each year by new applications and, just as importantly, by the lived, daily experience of producing chemistry that keeps pace with the field outside the factory gates.