West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

Rhodamine B isothiocyanate

    • Product Name Rhodamine B isothiocyanate
    • Alias RBITC
    • Einecs 219-022-7
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    812892

    Product Name Rhodamine B isothiocyanate
    Chemical Formula C28H20N3O3S
    Cas Number 36877-69-7
    Molecular Weight 477.54 g/mol
    Appearance Dark red to purple powder
    Solubility Soluble in water, ethanol, and DMSO
    Lambda Max 555 nm (in ethanol)
    Purity Typically ≥95%
    Storage Temperature 2-8°C
    Emission Maximum 580 nm
    Ec Number 253-057-0
    Synonyms RBITC, Rhodamine B isothiocyanate, XRITC
    Application Fluorescent labeling of biomolecules
    Melting Point 185-190°C
    Shelf Life 24 months

    As an accredited Rhodamine B isothiocyanate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Rhodamine B isothiocyanate from Sigma Aldrich/Merck/TCI Chemical is supplied in a 1-gram amber glass bottle with secure screw cap.
    Shipping Rhodamine B isothiocyanate from Sigma Aldrich/Merck/TCI Chemical is shipped in tightly sealed containers, protected from light and moisture, and appropriately labeled as a hazardous substance. Shipping complies with international and local regulations for chemicals, including UN identification numbers, and may require temperature control, documentation, and courier services authorized for hazardous materials.
    Storage Rhodamine B isothiocyanate should be stored in a tightly sealed container, protected from light and moisture. Keep it in a cool, dry, and well-ventilated area, preferably at temperatures between 2-8°C (refrigerated). Ensure storage away from incompatible substances, such as strong oxidizers. Label the container clearly and limit exposure to air to prevent degradation of the chemical.
    Free Quote

    Competitive Rhodamine B isothiocyanate prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Rhodamine B Isothiocyanate: Direct Manufacturer's Perspective

    Understanding Rhodamine B Isothiocyanate

    Years of dye chemistry have taught us that every raw material carries its own quirks and abilities. Rhodamine B isothiocyanate (RBITC) has found its place in our production lines not because it’s a household name, but because researchers and manufacturers pushed for robust, reliable fluorescent labelling. Each batch rolling off our reactors proves that the industry still relies on hands-on chemical production, not just distribution networks.

    Our RBITC, available as powder with high purity, isn’t an all-purpose pigment. It’s synthesized for scientific use, especially for labelling biomolecules. The core advantage -- a reactive isothiocyanate group -- makes it possible to form stable covalent bonds with amines. This isn’t abstract: whether the end customer works in protein sequencing, immunofluorescence microscopy, or flow cytometry, clear and permanent tagging ensures their results aren’t lost to signal fade or background noise.

    Batch Consistency and Purity

    Manufacturing fluorescents isn’t a one-size-fits-all process. We’ve seen how weaker purification or running synthesis at off-spec temperatures creates byproducts and shifts the absorption maximum. A good dye batch resists photobleaching, dissolves cleanly, and delivers the stated emission characteristics across all uses. We keep quality control locked in through HPLC, NMR, and UV-Vis checks, not just because regulations tell us to, but because poorly tagged antibodies or peptides waste weeks of work downstream. Scientists shouldn’t troubleshoot their staining simply because an upstream batch held too much residual solvent or side product.

    We take environmental monitoring seriously. Rhodamine dyes have drawn scrutiny for their environmental fate, so our lines run closed systems with solvent recycle, heat integration, and tested scrubbing solutions. Personnel wear appropriate PPE and we keep detailed logs to comply with local discharge regulations. This investment doesn’t just protect our community. It keeps production sustainable, so we aren’t chasing supply chain disruptions or regulatory shutdowns in the future.

    Specifications and Model Options

    Decades ago, most users only needed crude Rhodamine B in gram-scale. Now, projects demand milligram lots for specialized bio-conjugation or bulk runs in liters for industrial purposes. Our main model keeps a balance: substantial emissions at around 580 nm, narrow bandwidth, and purity above 95% (typically HPLC-confirmed to exceed 97%). Bottle packaging uses amber glass to avoid light-induced degradation, and batches receive a lot number traceable both to production logs and to independent spectroscopic fingerprints.

    Solubility and particle size play much larger roles than end-users realize. RBITC, as we make it, dissolves in DMSO, ethanol, and sometimes DMF, but resists water. Finely milled powder mitigates clumping and ensures rapid solution formation for critical experiments. If someone claims their dye “just works” in all buffers, they've likely skipped the repeatability checks necessary in western blots or cell-sorting workflows.

    Comparison With Other Fluorescent Labels

    Competition has grown fierce. Many biotech companies push sulfonated rhodamines or Alexa Fluor derivatives as upgrades. We’re asked regularly: why use RBITC, and not another dye? In practice, isothiocyanate chemistry allows direct coupling under mild aqueous conditions, which matters if your probe or antibody is heat- or acid-sensitive. Protein cross-links with isothiocyanates occur under physiological pH, preserving structure and activity, while NHS esters or hydrazides can lead to impure mixtures or unstable linkages.

    The emission max at 580 nm bridges a valuable window. Alexa Fluor 594 or Cy3 sit close by but require different excitation or more specialized filters. RBITC emissions, combined with high molar extinction coefficients, allow detection even at sub-microgram concentrations. We’ve seen labs wring more sensitivity from RBITC-labeled proteins than cheaper alternatives, especially under confocal microscopy. Spectral bleed-through remains minimal when paired with FITC (fluorescein isothiocyanate) or DAPI stains, which helps everyone who juggles multiplex labels in a single experiment.

    Real World Applications

    Fluorescent dyes support plant and animal research, food safety, diagnostic kits, and quality control. RBITC finds its home in immunostaining tissue sections, tracing protein interactions, or barcoding cellular populations for flow cytometry. Researchers ask for dye–protein ratio guidelines, because over- or under-labelling can skew quantitative results. Typical conjugation requires a molar excess of dye (sometimes 3- to 10-fold over protein) and purification by desalting or column chromatography. Antibodies for cancer research really benefit from strong, reproducible signals; poor dye lot selection means weak signal and repeat expenses.

    Our dye appears in protein sequencing, tracing the terminal residues via Edman degradation, and facilitates microbe detection in contaminated water. End-users vary from academic labs to pharma quality teams. In every case, sensitivity to batch-to-batch variations remains vital. Analytical scientists note that cheaper, impure dyes can introduce side-bands, wrong fluorescence intensity, or unexpected cell toxicity. Consistency controls the downstream trust in RBITC-based detection.

    Handling & Safety

    Safety matters as much as yield. Even though RBITC is designed for laboratory environments, accidental skin contact or inhalation can pose risks due to its protein-reactive nature. During synthesis, we found early on that trace cyanide byproducts hid in some crude extracts, so our process includes extra purification to eliminate risk to end users. All factory work proceeds under hoods, gloves, and eye protection. We ship only verified, properly labeled containers. Our documentation, built from real production experience, walks users through safe handling, storage, and cleanup. Spills receive immediate neutralization since the dye can stain surfaces for weeks.

    Large-scale production meant confronting disposal issues. We built a waste stream segregator, sending non-chromophoric byproducts for incineration and recovering as much spent solvent as possible for re-purification. These aren’t small add-ons – regulatory officers perform unannounced audits, and our long-term contracts depend on positive compliance records. Training our staff reduces exposure, while strict workflow separation keeps RBITC far from incompatible materials. A robust, documented process lets us pass scrutiny and sustain a safe workplace.

    Critical Differences from Other Industry Offerings

    A big misconception: all Rhodamine B derivatives behave alike. Years in this specialization make it clear they don’t. Regulatory grades, purity, counter-ion composition, and residual solvent content shift dye performance field-to-field. Mass spectrometry can pick up trace contamination from glassware, packaging, or impure starting materials. False positives have cost some customers their entire experiment because the dye supplier let impurity creep exceed a few tenths of a percent.

    Our process keeps rigid controls on each step. In collaboration with scientists, we've tuned reaction times to minimize urea formation and avoid structural analogs with unwanted cross-reactivity. Our packaging team seals every batch under dry nitrogen to inhibit moisture uptake, which could lead to hydrolysis. We ship globally to validated addresses, always logging expiration and production dates so return customers never wonder about the history of what they're getting.

    Feedback from contract partners and direct end users drives our product. Unlike some resellers, we’ve got access to micro-scale batches for method validation or training samples, and can accommodate scale-up for larger diagnostic kit companies. If a lab needs a tighter bandwidth, custom blends, or trace impurities flagged, our production handles this. Selling direct means problems reach us fast, and we adapt quickly. Contracts aren’t just about tonnage or price, but longstanding relationships built on trust and responsiveness.

    Limitations and Ongoing Challenges

    RBITC does not perform identically in every bio-conjugation scenario. The isothiocyanate group reacts with primary amines, and too many accessible lysine residues can result in dye clustering, fluorescence quenching, or steric hindrance in protein-protein interactions. Inconsistent coupling conditions create lot-to-lot variability in labelling degrees. We learned to offer application support directly, advising on optimal dye:substrate ratios and buffer recipes, so customers reduce time troubleshooting rather than generating publishable data.

    Rhodamine B backbone dyes require specific storage to prevent light-induced degradation and oxidation. Long-term reliability depends on temperature-controlled logistics from our plant to users. Some countries present customs or regulatory issues with import permits or product classification. These hurdles demand careful documentation and advance warning, especially for pharma users preparing for audits or clinical use.

    Innovations in Manufacturing and Quality Control

    Few manufacturers run dye synthesis on-site anymore. We’ve invested in small-batch reactors and automation to maintain batch fidelity, conducting in-process analytics rather than waiting for finished product checks. We catch off-color or misbehaving product before packaging. Advanced analytic technology such as 2D NMR and HRMS ensures each batch matches the spectral signature drawn from reference standards. Labs using RBITC at the single-molecule level require this extra confidence. For end applications like single-cell sorting or quantitative PCR tagging, a clean, consistent fluorescent signal removes the need for run-after-run calibrations.

    Waste minimization matters. Our teams recover spent solvents and reduce total solvent per kilogram of product. Process improvements in the last year cut hazardous emissions and reduced chemical usage without dropping output. It took time and capital, but now compliance paperwork reflects a cleaner process and finished dye. Pushing higher levels of sustainability gives us more room to grow with less regulatory risk or community complaint.

    Total Product Lifecycle Awareness

    We do more than deliver a bottle. Users require documentation tracing every lot from raw input to shipping, so our systems log every detail: operator IDs, synthesis logs, intermediate QC, and final spectral analysis. This traceability means less downtime if an issue emerges, and builds long-term confidence in product performance. Large biotech clients sometimes require old production records for regulatory filings or audits; we keep these securely and can retrieve them years after shipment.

    Continuous training for our staff means understanding not just how to run a reactor or bottle a dye, but why a missed step in drying protocol or poor temperature control can cause downstream research failures. Each team member sees the broader connection between careful manufacture and customer outcomes. Support calls reach technical experts on our floor, not distant call centers. That means a university researcher or pharmaceutical developer receives real, process-driven advice the same day a concern comes up.

    Collaboration with End-Users

    Manufacturers who stay walled off from application feedback fall behind. Our chemists and support team engage with customers at the method development and troubleshooting phase. This two-way flow improves conjugation protocols, buffer formulation, and even guidelines for optimal storage. By seeing which conditions degrade dye performance or lead to signal loss, we adjust our own processes and share findings with future clients.

    Sometimes breakthroughs come from joint projects – a pharmaceutical firm adjusting its preclinical assay, or a diagnostic kit manufacturer moving from crude to high-purity tags. Our willingness to set up test batches at their specification, analyze downstream yields, and tweak the recipe distinguishes us from trading companies or simple warehouse resellers. Building trust through technical depth and fast turnaround cements our partnerships.

    Looking Ahead: Future Needs and Industry Pressures

    RBITC production shares challenges with other specialty chemicals: rising regulatory scrutiny, supply chain shocks, and demand for greener processes. Our purchasing team keeps qualified second sources for all key raw materials, and our engineers monitor every point of potential bottleneck. Continuous updates from scientific literature guide incremental improvements. Whether it’s adjusting for new labeling techniques, alternate solvents, or safer process steps, we stay agile because end users depend on every variable staying controlled.

    For biotech and research labs racing to decode biology or refine diagnostics, production stability and product quality determine both publication success and regulatory compliance. Our perspective, built on decades of hands-on manufacturing, brings solutions rooted in process control, technical transparency, and direct engagement. RBITC may only be a small part of a much larger scientific project, but keeping its integrity at every stage – from synthesis to application – supports discoveries that ripple far beyond our own factory gates.