HS Code |
302903 |
| Product Name | Residual Free Chlorine (RFC) Reagent |
| Manufacturer | Sigma Aldrich/Merck/TCL |
| Catalog Number | Varies by supplier |
| Chemical Form | Powder or tablet |
| Application | Water analysis for residual free chlorine determination |
| Colorimetric Method | DPD (N,N-diethyl-p-phenylenediamine) method |
| Appearance | White to off-white solid |
| Solubility | Soluble in water |
| Storage Conditions | Store at room temperature, keep container tightly closed |
| Hazard Classification | Irritant; avoid inhalation and skin contact |
| Shelf Life | Typically 1-2 years unopened |
| Packaging Size | Commonly available as 100 tests or 500 g container |
| Cas Number | Varies (often mixture—see SDS) |
| Assay Purity | Reagent grade |
As an accredited Residual Free Chlorine (RFC) Reagent factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The RFC Reagent is packaged in a 500 mL amber glass bottle, securely sealed, and labeled with chemical details and handling instructions. |
| Shipping | The Residual Free Chlorine (RFC) Reagent from Sigma Aldrich/Merck/TCI Chemical is securely packaged in leak-proof, chemical-resistant containers. It is shipped in compliance with international safety and hazardous materials regulations, ensuring temperature stability and integrity. Documentation, including MSDS, accompanies shipments to guarantee safe and compliant delivery to laboratory destinations. |
| Storage | Residual Free Chlorine (RFC) Reagent from Sigma Aldrich/Merck/TCI Chemical should be stored in a tightly closed container in a cool, dry, and well-ventilated area away from direct sunlight, heat, and incompatible substances such as acids and organic materials. Keep the storage area clearly labeled and equipped with appropriate spill control and safety equipment. Follow all safety guidelines specified in the reagent’s SDS. |
Competitive Residual Free Chlorine (RFC) Reagent prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Water treatment engineers and plant operators face a familiar challenge: precise monitoring of residual free chlorine. As manufacturers, we have worked side-by-side with plant teams to understand the critical role accurate residual free chlorine readings play in drinking water and wastewater treatment. Getting the chemistry right at the detection stage can save thousands of people from exposure to under- or over-chlorinated supplies. Our Residual Free Chlorine (RFC) Reagent does not simply move through a supply chain to reach an end user — it starts with a commitment to purity, batch reliability, and field-tested functionality.
Developing the RFC-210 formulation took years of experimentation on our shop floors and lab benches. We spent long hours tweaking pH buffers, refining stabilizer concentrations, and integrating anti-interference compounds to suit both manual colorimetric kits and automated analyzers. Our team focused on rapid dissolution in cold water and consistent shelf-life performance, which proves necessary for plant managers running through extreme temperatures and shipment delays. We calibrate RFC-210 production against laboratory references and challenging real-world water samples, some drawn directly from municipal lines and industrial outlets.
A common question during site visits concerns the visible clarity and prompt color development of our reagent after dosing with treated water. Our technicians have raised this point in feedback meetings for years. Reaction speeds must match field ops—ten drops cannot mean ten minutes lost behind a control panel. Because of these efforts, RFC-210 solutions produce sharp, stable color changes in less than sixty seconds—operators see the result and move on.
Specifications for a reagent often sound cold on a spec sheet. We approach each batch knowing what is at stake at the customer’s valve or sedimentation tank. Chlorine detection relies on the reagent’s ability to ignore noise from manganese, nitrite, or iron, while providing consistent milligram-per-liter readings across temperature ranges. Our RFC-210 offers a clear detection range from 0.02 to 4.0 mg/L. We calibrate the visual and instrument response curves to closely track international standards. QC staff test every lot against both low and high chlorine content samples—direct from station outlets—to confirm reading accuracy, not just in distilled water but in real operating water.
We manufacture RFC-210 as a ready-to-use liquid solution, rather than a powder or two-part system. Field technicians repeatedly told us that powders clump, spoons get lost, and mixing errors creep in as shift fatigue sets in. A pre-diluted liquid removes these steps, saving time and reducing opportunity for error. Operators unscrew the cap, dose, and view the response. Larger volume bottles suit labs; small dropper vials support mobile site testing.
In water treatment, residual free chlorine quite literally stands between healthy communities and disease outbreaks. Drinking water must contain just enough chlorine to keep pathogens at bay as it travels through pipes, but not so much that taste, odor, and corrosion become unacceptable. Based on decades in the chemical plant and at site commissioning visits, we see firsthand the confusion a misreading can cause: an unnecessary system flush, a community complaint, or—worse—a failure to remove contamination.
It’s not simply about following compliance rules. We remember troubleshooting spikes and drops in chlorine readings at remote pumping stations. One operator, frustrated by false positives due to turbid samples, started bypassing his test kit. With RFC-210, we built redundancy for known sample interferences. With thousands of batches shipped, we’ve heard fewer call-backs for test clarity or re-testing. That gives operators peace of mind and frees management to focus on larger plant upgrades instead of daily testing blips.
Reagents that degrade on the shelf waste both time and trust. Over the years, we have responded to customer complaints about batch-to-batch inconsistency and losses during unexpected warehouse delays. RFC-210 contains stabilizers developed to hold target performance for a full eighteen months under recommended storage. Every release batch undergoes accelerated aging tests—heated, chilled, frozen, then tested again—by technicians who know the real-life risks of storing chemicals in metal-sided treatment sheds. It’s normal for us to receive pictures from customers’ lab benches cluttered with expired, half-full bottles from other brands. We want RFC-210 to stand apart—if the shelf life reads true, we keep the line running that way.
Years ago, we noticed that not all plant staff measure or read chlorine the same way. Some follow color card matches to the letter; others judge visually, especially in direct sunlight or after long shifts. Removing ambiguity became a design target. RFC-210 produces a violet color shift using DPD chemistry, with enhanced contrast in turbid or yellow-tinted waters. Our engineers performed dozens of observer accuracy tests, holding up sample tubes to shop windows in late afternoon sunlight. Small details like the angle of the vial, the translucence of the sample, or residual bubbles inside glassware all affect readings. We included explicit contrast enhancers in the RFC-210 solution and encouraged “blind double runs” during validation work.
Feedback from field workshops helped us refine instructions for line operators and lab staff. Pictorial guides, not just text, came out of these sessions to simplify training for new hands or seasonal staffers. A number of older operators requested tactile bottle markers for identifying reagent type in dim utility rooms. We responded with raised lot number stamps and extra-wide dropper nozzles, all adjusted in production without raising cost or complexity for the customer.
Products named “chlorine test reagent” may appear interchangeable on a product catalog, but experience teaches otherwise. Powdered kits absorb moisture on humid days, forming clumps. Two-part liquids can leave streaks of dye on the bottle neck, leading to color drift and wasted runs. We designed our RFC-210 to avoid such common lab complaints. Additional anti-foaming agents eliminate false surface readings, a problem most visible to operators running older photometers or performing visual reads after mixing. We have incorporated these changes not at the request of resellers, but following side-by-side evaluation alongside plant workers who cannot afford errors in the middle of a real emergency.
Our RFC-210 formula resists photodegradation, allowing bottles to sit out on workbenches between tests. The solution does not separate over time or deposit crystals in the dropper. Workers who received training directly from our site teams noted fewer failed tests, and supervisors reported a drop in “unknown cause” results for chlorine that slowed daily rounds. These practical changes come from standing inside the treatment plant, rolling up sleeves with end users—not simply from bench trials.
Unfiltered municipal samples and industrial effluents contain more than pure H2O and disinfectants. Iron, manganese, organic debris, and even residues from polymer flocculants challenge most chlorine detection chemistries. We have spent years testing RFC-210 with raw and treated waters across cities and provinces. Our lab folk collected influent from iron-rich wells, storm runoff, and even secondary effluent—a showcase for problems seen nowhere in the brochure. Results consistently come out predictable, with color shifts holding clear.
Few things frustrate a plant superintendent like failed QA audits caused by off-range readings. We share these frustrations; engineers at our own plant’s water taps see the same. By adjusting our anti-interference blend, we’ve brought RFC-210 performance closer to real-world water chemistry while avoiding false positives from background ions or common cleaning agents left behind on glassware.
Improving in-plant workflow means less chemical waste and fewer errors under stress. Older powder- or tablet-based kits call for careful handling and perfect timing—hard to guarantee in cold, wet, or crowded utility sheds. RFC-210’s liquid formula needs only a dose and a shake, minimizing exposure to dust and spills. Waste bottles returning from municipal and private customers consistently record lower residual mass in the bottle—proof that users finish up rather than discard half-used containers. Our design makes it easier to drain every last drop and avoid the temptation to throw out reagent “just in case.”
We have seen labs battle through test runs with multiple brands in search of the one that provides trustworthy, fast results in a range of waters. Every time we revise or batch RFC-210, we draw not on theoretical performance, but on a collection of feedback, complaints, and real-world “wish list” features logged from years of operator experience. Our plant staff, many of whom started as testbench technicians themselves, vet each improvement by watching users in action—not by measuring only against artificial standards. This hands-on tradition makes our RFC-210 distinct in purpose and practice.
During the pandemic, we supported municipalities as they put backup staff—sometimes with no routine chemistry training—to work. The RFC-210 formula cut error rates and produced reliable, quickly readable results. Supervisors could check logs and flag outlier readings in minutes rather than hours, freeing them for higher-level troubleshooting. If you ask a municipal water manager what matters in a reagent, trust and repeatability—and not just reaction speed—top the list. Our experience tells us that easy handling, long shelf life, and predictable results drive that trust.
Continual improvement must rely on both numbers and stories from the field. Over the years, plant upgrades, operator turnover, and evolving standards—for example, local authorities requesting lower chlorine levels—forced us to revisit RFC-210’s detection limit and color contrast. By adjusting the ratio of dye and buffer, we made small changes that improved visibility at lower ppm. Our technical service reps relay feedback from field crews straight to the production manager’s desk.
Regular external audits on safety and quality compliance push us to maintain clean-room protocols and batch traceability. Every batch gets a unique identifier, and we keep retention samples for over two years—longer than required—so users can track results back and troubleshoot if needed. Recalls or out-of-spec incidents rarely occur, but our approach means issues are traced and resolved before a small problem grows.
Container failures frustrate users and risk contamination. Through years of observation, we swapped competing dropper and bottle materials and tested for resistance to temperature swings, UV exposure, and rough handling. RFC-210’s packaging has been battered across different plant environments. From sub-zero utility sheds to 40°C waterworks vaults, bottle plastic and cap fitment show little change. Reduced bottle distortion and cap leaks mean fewer service calls and less hazardous chemical residue on benches.
We do not overlook simple things. Clear, permanent lot numbers, expiration dates in black print, and dropper tips that fit both large- and small-diameter glassware came straight from plant managers’ feedback. We stripped out unnecessary labeling and increased text contrast so operators can read at a glance amid hectic routines. Caps lock and unlock with a quarter-turn, useful for gloved hands.
Most purchasing staff—from experienced procurement officers to field engineers new to the job—face a market filled with similar claims and few facts about how a reagent runs in challenging environments. From our side of the manufacturing process, we understand the trap of “race-to-the-bottom” pricing and the need for proven, not just promised, performance. We suggest that users ask suppliers for hands-on operator feedback, not only test results from distilled water. We often provide direct dispatch to pilot operations so engineering teams can run side-by-side comparisons before full adoption.
RFC-210’s track record includes deployments in harsh climates, high-turnover plants, and evolving regulatory settings. We continue to batch, refine, and document improvements, and we encourage open feedback. Every production lot tells a story not just of chemicals and hardware, but of partnership between manufacturer and operator.
Each case of RFC-210 ships out after dozens of plant-floor checks and field-ready tests. We do not hide behind anonymous production lines or distant corporate offices. We bring our experience from the factory floor, field pilots, and operator training rooms to every bottle we make. RFC-210 stands as the outcome of years working together with real people at the helm of water security.