HS Code |
845093 |
| Product Name | (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol |
| Cas Number | 88157-59-7 |
| Molecular Formula | C15H9F3O |
| Molecular Weight | 262.23 g/mol |
| Appearance | White to off-white solid |
| Optical Purity | Enantiomerically pure (R)-form |
| Specific Rotation | [α]D20 = –45° (c=1, CHCl3) |
| Melting Point | 60-63 °C |
| Solubility | Soluble in common organic solvents (e.g., CHCl3, Et2O) |
| Application | Chiral discrimination and e.e. determination by NMR |
| Purity | ≥98.0% (HPLC) |
| Storage Conditions | Store at 2-8°C, tightly sealed |
| Synonym | (R)-(-)-ATFE |
As an accredited (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol [e.e.Determination Reagent by NMR] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The 1-gram (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol comes in a sealed amber glass vial with labeled hazard warnings. |
| Shipping | Shipping of (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol [e.e. Determination Reagent by NMR] from Sigma Aldrich/Merck/TCI follows standard protocols for chemical reagents. The compound is securely packaged in appropriate containers, accompanied by safety documentation, and shipped according to relevant hazardous material regulations to ensure safe and compliant delivery. |
| Storage | (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol should be stored in a tightly sealed container at 2–8°C, protected from light and moisture. It should be kept in a well-ventilated, cool, and dry area, away from incompatible substances such as oxidizing agents. Proper chemical storage protocols and personal protective equipment (PPE) should be followed for safe handling. |
Competitive (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol [e.e.Determination Reagent by NMR] prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
As a producer deeply rooted in the practical realities of organic synthesis, we have seen firsthand how (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol has shifted expectations within the world of chiral NMR analysis. In daily production, reliability and reproducibility drive decisions. Our ongoing investment in purification lines and analytical controls started as a response to typical headaches: inconsistent enantiomeric excess, problems in peak assignment, and margin for operator misjudgment in high-throughput labs. Over years of listening to feedback from teams both in-house and scattered across diverse industries, it became clear that both research chemists and process developers wanted more than just another reagent—they needed clarity, speed, and reliable, defensible data.
We see a good deal of talk about chiral alcohols, oxazolidinones, and other derivatizing agents for enantiomeric excess determination. Yet, (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol stands apart for reasons anchored in direct laboratory experience rather than textbook summary. The trifluoromethyl group, locked in a position away from the stereocenter, proves invaluable in creating distinct, well-separated signals for diastereomers during NMR acquisition, especially in 19F NMR. The anthracene scaffold brings a rigidity and shielding effect, reducing signal broadening even when working with a range of α-chiral acids and alcohols as analytes. Chemists tackling applications in pharmaceutical process control, catalyst screening, and asymmetric reaction development have noted sharp, diagnostic peaks, simplifying quantification without elaborate mathematical deconvolution.
We ship the reagent with enantiopurity exceeding 98%, a consistency that reflects tight monitoring and aggressive elimination of side-products and racemization in every batch. The material’s purity translates into direct confidence: unnecessary background signals or trace contaminants rarely complicate spectra. Physically, the compound’s crystalline form aids in simple weighing and transfer, preventing drift in stoichiometry during preparation of test solutions. Melting points and specific rotations often spark debate among buyers, but our multi-step verification—using both polarimetry and HPLC—minimizes batch-to-batch differences, staving off many practical headaches seen with sources relying mostly on bulk recrystallization.
Our own research and customer feedback reveal persistent contrasts between (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol and older generation chiral probes. Many of those probes yield ambiguous or overlapping peaks in non-ideal solvents or with samples containing chiral impurities. In contrast, chemists using our compound routinely obtain doublets or singlets, easily assignable even at moderate field strengths (typically 400 MHz), without extensive sample manipulation. The practicality of its trifluoromethyl signal in 19F NMR, absent in most organic backgrounds, dramatically streamlines data processing and interpretation, reducing error rates during night shifts or when analysts train newcomers.
The heart of this approach lies in accurate, quantitative assignment of enantiomeric excess—an outcome that shapes everything from intellectual property filings to batch release in pharmaceutical manufacturing. By harnessing the rigid anthracene core and electronically distinct trifluoromethyl group, our reagent forms stable, rapid adducts with a wide variety of α-chiral substrates. Peaks stay sharp even at lower concentrations, avoiding the integration drift sometimes seen with alternative derivatizing agents.
Years of hands-on production have taught us the value of listening to complaints. Users of generic versions frequently cite inconsistent powder handling, discoloration, and vapor-phase contamination interfering with spectra. Our operation employs high-efficiency filtration and low-moisture packing lines, safeguarding against these real-world problems. We deliberately avoid additives or stabilizers that show up as contamination in sensitive NMR studies, taking care that each vial reaches the customer as close to “as synthesized” as possible. Chemists have commented on the difference: visible clarity of crystals, repeated high yields in derivatization reactions, and a near-complete absence of “ghost peaks.”
Within our own quality control and research arms, (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol steps outside the narrow definition of a specialty reagent. We use it for rapid reaction monitoring in asymmetric syntheses, double-checking the progression of small-scale and pilot batches. Its performance as a diagnostic probe for contamination—catching the odd enantiomer slip in kilolab runs—saves costly rework and delays downstream. Customers often share similar uses, from fuel additive analysis to chiral building block qualification, where peak clarity shaves time off routine workflows.
As a manufacturer, we keep our eyes on practical storage realities. The compound’s stability under ambient and refrigeration conditions keeps losses minimal. We routinely run year-long stability checks and sample freshly handled vials under actual shipping stress, confirming that no meaningful hydrolysis or degradation takes place outside lab extremes. Unlike some fragile derivatizing agents or chiral auxiliaries that break down under mild temperature swings, this material handled in standard glass or fluoropolymer containers stays clean and active, even after months on shelf.
Producers often get boxed into a discussion about “green chemistry” and process hazards. Here, our product’s relatively high melting point and crystalline nature mitigate volatilization hazards during handling and transfer. Routine solvent rinse and reuse become much easier when crystals readily separate from filtrate. Release of trifluorinated by-products—a concern with many fluoro-organic reagents—remains negligible throughout our standard end-user recommendations. Our in-house safety data show low risk of respiratory exposure or acute toxicity, especially when compared with volatile chiral amines and some oxazolidinone derivatives, whose vapors require active extraction even in small bench settings.
Our operators watch workflow bottlenecks closely. Products that require extensive pre-drying, inert atmosphere transfer, or special glassware slow entire production campaigns. (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol brings a degree of robustness—direct from shelf to laboratory prep, minimizing downtime and bottleneck costs. Every change in process or formulation gets run through actual user simulations, not just theoretical models. Our teams keep meticulous logs when a batch veers from baseline, comparing NMR results day-to-day over recurring shifts. Troubleshooting nearly always highlights the chemical’s stability and ease of isolation as key factors avoiding lost production.
Direct communication with technical teams across the globe shapes our internal priorities. Clients consistently highlight concise, well-resolved signals in both 1H and 19F NMR spectra—even as instrumentation ages or maintenance cycles lengthen. They also raise challenges that we turn into iterative improvements: dust suppression in packaging, scales for precise reagent addition, and removal of static-prone crystal fines. Our support staff talk shop with both process managers and junior bench chemists, helping translate best practices into step-by-step handling guides that reduce real risk of operator error and lost samples.
The market rarely stands still. Manufacturers around the world compete across several lines—chiral shift reagents, lanthanide complexes, and various custom auxiliaries. Yet, most alternatives introduce layers of complexity, often requiring prolonged preparation, elaborate work-up, or even specialized waste management. We have spent years benchmarking our product against industry standards. The critical difference: this reagent reacts quickly at room temperature, avoids exothermic runaways, and doesn’t foul NMR instrument lines or columns with persistent trace materials. Many users switching from phosphine-based or metal-chelating agents remark on the sharp contrast in daily clean-up and uptime, turning occasional maintenance drama into routine laboratory work.
Producing chiral auxiliaries at commercial scale brings recurring challenges that traders or lab-scale synthesis companies never face. Minute changes in temperature, plant humidity, or even lot-to-lot variance in starting materials can impact both purity and enantiomeric ratio. We continually refine and automate each stage, employing real-time HPLC monitoring and NMR fingerprinting. Feedback from regulatory audits—especially in regions with rising oversight of advanced chiral reagents—push us to further tighten quality standards. By investing in both process analytics and warehouse environmental controls, we reduce the headache of failed lots, re-testing, and delay-filled supply chains—a task only true manufacturers take seriously.
Lab chemists bring us problems that rarely get solved by textbook answers. One recurring example: differentiating between close-running diastereomers in non-deuterated solvents. Our own staff encountered this during a high-throughput optimization campaign, leading us to tweak purification flows and change drying protocols. These adaptations, informed by hands-on troubleshooting and later confirmed by user feedback, now come standard with every lot. By embedding this kind of learning into batch documentation and technical support, we pass on solutions sharpened by actual experience, not abstract marketing.
Day-to-day operations at scale inform every priority we set. As analytical needs expand—driven by new catalysts, more complex APIs, and stricter standards for enantiomeric excess—manufacturer-level collaboration with customers will drive next-generation refinements. We prioritize direct laboratory visits, sample trial programs, and data transparency, knowing that the best solutions emerge from shared learning around actual NMR spectra, not from simple catalog exchanges.
Reliability, clarity, ease of use—these values underpin every batch we make. Integrating enantiomeric excess reagents into a fast-moving industrial or research pipeline requires more than a technical data sheet. Only those who actually mix, pack, weigh, and test each lot, day after day, see which process details shave precious hours off operator training and reduce avoidable loss. By anchoring improvements in what real users—both inside and outside our own facility—report from daily struggles and successes, we keep raising the bar for both analytical performance and smooth, predictable workflow.
Every innovation or process adjustment behind (R)-(-)-2,2,2-Trifluoro-1-(9-anthryl)ethanol springs not from abstract market demand, but from focused attention to where users need reliable NMR data and actionable, repeatable measurements. Heavy investment in in-house R&D, direct customer feedback, and a philosophy rooted in practical, whole-system workflow continues to distinguish this reagent from more generic, distributor-driven offerings. Whether in the hands of high-throughput pharmaceutical process teams, academic researchers, or industrial manufacturers, our product reflects years of cumulative, hard-won know-how that only comes from being at the frontline of chemical manufacturing.