|
HS Code |
368442 |
| Product Name | Phosphate Buffered Saline (pH 7.4, Sterile) |
| Brand | Sigma Aldrich/Merck/TCL Chemical |
| Ph | 7.4 |
| Sterility | Sterile |
| Form | Liquid |
| Composition | NaCl, KCl, Na2HPO4, KH2PO4 in distilled water |
| Osmolarity | Approx. 290 mOsm/L |
| Storage Temperature | 2-8°C |
| Appearance | Clear, colorless solution |
| Application | Cell culture, molecular biology, immunoassays |
| Buffering Capacity | Moderate at physiological pH |
| Endotoxin Level | < 0.25 EU/ml (may vary by product) |
| Packaging | Plastic bottle |
| Concentration | 1X (ready-to-use) |
As an accredited Phosphate Buffered Saline (pH 7.4, Sterile) factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Clear plastic or glass bottle, 500 mL, labeled "Phosphate Buffered Saline (pH 7.4, Sterile)," Sigma-Aldrich/Merck/TCI Chemical, tamper-evident cap. |
| Shipping | Phosphate Buffered Saline (pH 7.4, Sterile) from Sigma Aldrich/Merck/TCI Chemical is shipped at ambient temperature in securely sealed, sterile packaging to maintain product integrity. The shipment follows standard safety and handling guidelines for non-hazardous laboratory reagents, with documentation and tracking provided for reliable delivery. |
| Storage | Phosphate Buffered Saline (pH 7.4, Sterile) from Sigma Aldrich, Merck, or TCI Chemical should be stored at 2–8°C, protected from light and contamination. Keep the container tightly closed when not in use. Avoid freezing, as this may compromise product integrity. Use aseptic techniques to maintain sterility. Refer to the manufacturer's guidelines for specific storage recommendations. |
Competitive Phosphate Buffered Saline (pH 7.4, Sterile) prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Every lab leans heavily on buffers, and phosphate buffered saline stands as a foundation for cell culture and routine biological work. From our experience making PBS day in and day out, we’ve learned where corners might get cut and the headaches that follow. Our Phosphate Buffered Saline (pH 7.4, Sterile) isn’t just a routine batch for us—it’s the result of careful sourcing, validated mixing, and tight quality controls, brought together by operators who know why that matters. Contamination turns a project upside down, so we put sterility at the center, not just as an afterthought or a label. There’s a real difference between buffers that look the same on paper and those that simply behave better in use, and we see it all the time in feedback from our largest biotech clients and smaller academics alike.
Some catalogs boast about high purity grades, but it’s the consistency between batches that protects experiments. During our production, we standardize raw material inspection and focus on exact weighing. That removes the major headaches that happen when a buffer lot turns out different two months later. Our teams keep pH tolerance tight at 7.4, not just at the start of the process, but through stability trials. We calibrate meters before every batch so that the user, whether running immunocytochemistry or prepping tissue samples, sees no drift or oddities in baseline readings.
Control doesn’t stop at measurements. It means training staff to spot the little things: discoloration during mixing, residue in tanks, or changes in viscosity in storage. We’ve scrapped more than one batch because it didn’t hit every point on our roadmap. Over time, that commitment forms the backbone of a reproducible result for customers, because a buffer is only as good as the pattern of performance it sets. If it varies, it costs time and trust.
In our catalog, PBS, pH 7.4, Sterile—Model PBS-S74—fills routine needs for schools, clinical labs, biotech, and pharma R&D. We produce sterile fills in volumes ranging from 100 mL to 10 liters. For strict aseptic work, the entire line runs through validated filtration. Nothing leaves the cleanroom unless each lot passes bacterial and fungal sterility tests. Our main lot, PBS-S74, ships in molded HDPE or glass bottles, so compatibility never gets in the way of workflows whether labs use glassware or plastics.
From mixing bulk five-liter containers in a large R&D department to opening single-use vials at a field hospital, we’ve adapted packaging solutions based on what actual usage scenarios look like—no generic one-size-fits-all here. Real feedback from customer service calls finds its way back to the packaging design table. If there’s a report of jammed caps, leaking seals, or hard-to-read labels, we follow up with tangible changes. In one case, that led to a whole redesign on the 500-mL cap threading, saving dozens of wasted bottles per month in a major teaching hospital.
Manufacturing buffer solutions in volume isn’t as simple as scaling up a recipe from the bench. We sweat through water source validation for every batch of PBS, drawing from deionized and then double-distilled water. A hiccup in water quality shows up quickly in cell lines—users call asking about unexplained toxicity, and it often tracks back to overlooked basics. To prevent that, we audit our water system every shift. Our operators rinse and validate vessels, pipes, and valves, logging readings after each step. Phosphate and saline are both hygroscopic, so raw material containers carry strict storage protocols.
Mixing in stainless tanks under laminar flow, we maintain temperature and mixing speed logs. During one hot summer, cooling failure almost introduced variance in buffer density—so now alarms and fail-safes alert teams to ambient changes, and digital readouts create a transparent trail. This relentless process discipline isn’t just for compliance. If you’ve seen cell cultures die off or immunoassays show background interference, it’s often due to overlooked production variables. Our team understands the implications of even slight deviations, because we field the calls and see the failed experiments that come from cheaper, sloppier buffers.
Many suppliers list “sterile” on a spec sheet, but that doesn’t mean much if the process isn’t validated end to end. We run final filtration through 0.22 micron filters, then package and seal products under ISO-certified cleanroom conditions. Our sterility program goes deeper than a test vial or paperwork—our QC team pulls samples from across every batch, not just front and tail ends, and cultures them under aerobic and anaerobic conditions. That’s just necessary because microscopy and sensitive diagnostic assays pick up even low-grade bioburden that doesn’t show up in basic plate tests.
For those working in stem cell or immune cell research, nonsterile PBS can destroy weeks of effort in a few hours. We hear from CROs who share stories of failed lots that trace back to poorly sterilized buffer bottles. We audit cleaning and sterilization routines, with comprehensive logs for each batch. Feedback from labs who use our buffers for tissue transport and organ culture notes zero bacterial contamination in over three years of supply—in large volumes, that level of reliability makes full cohort studies feasible rather than a risk.
A buffered solution might sound boring, but for biological systems, pH is everything. Too high, and cells round up and detach; too low, and proteins denature or aggregate. We anchor our PBS to pH 7.4 for a reason—every deviation, even within a tolerance listed by some manufacturers, can mean a failed western blot or useless cell passage. Our team spent months optimizing the order of reagent addition to minimize local hotspots or clumping, reducing pH swings.
Cell culture labs depend on PBS that won’t drift with time or temperature. During hot summers or power outages, pH can veer without proper controls. We include pH stability testing over a multi-week period, storing reference samples at room temperature and refrigeration, so users aren’t left guessing whether last week’s bottle will match today’s. Not all “pH 7.4” buffers hold true to label over time, but ours tracks closely—internal testing averages a drift well within ±0.05 across 8 weeks.
PBS serves as more than a rinse or wash. Whether for tissue dissection, immunostaining, or thin-layer chromatography clean-up, it’s everywhere. In our production notes, we see a surge in shipments to tissue banks during organ harvesting seasons because cold PBS keeps biopsy samples viable during transit. In pharmaceutical QA, QC analysts rinse glassware and instruments with PBS to avoid trace ionic contamination from tap or unbuffered water, preserving the reliability of mass spec and HPLC runs.
Our PBS forms the backbone for cell culture detachment, serving as the rinse step before trypsinization. For labs growing sensitive or primary lines, lot-to-lot consistency matters—a cell line that thrives in batch A can fail in batch B if ionic balance goes awry. Even diagnostic kits that rely on ELISA or rapid antibody testing rely on PBS to prevent nonspecific binding and background signal. Our relationship with industrial partners who assemble rapid diagnostic tests in high volume led us to automate lot verification runs on their test strips before each shipment—a dialogue that shaped ongoing improvements.
We test our PBS in parallel with competitor brands, running head-to-head trials in cell viability and immunocytochemistry. Some PBS products claim the same specification, but in use, we see differences: precipitation at low temperatures, unexplained turbidity after days on the bench, or difficult resuspension of pelleted cells. Those issues rarely show up on a TDS or leaflet, but they show up in practice.
One of our institutional partners switched to us after identifying undissolved particulates in another major supplier's buffer bottles, leading to washed tissue samples showing granularity under microscopy. Our production keeps solution clarity as a performance benchmark, and we run routine subvisible particle counts using laser-based technology common in injectable-grade preparations—even though PBS is rarely injected, that level of scrutiny filters down to everyday research use and reduces unexplained variability in sensitive assays.
High-volume diagnostics manufacturers have also reported mislabelled concentrations and batch-to-batch swings in salt levels from other suppliers. Our own ion chromatography confirms each batch against reference solutions. We don’t blend batches to “average out” errors, a practice some competitors quietly adopt. Instead, failed batches get scrapped outright, because banking on averages leads to outlier-induced failures, especially in precision work.
PBS might seem static as a product, but user needs evolve. Our team lives on feedback, and the best ideas come from the frustrations or wish lists of research partners. A major oncology lab pointed out capillary tube clogging during antibody labeling; it turned out to be a rare microprecipitation issue in cold storage. We fine-tuned the order and temperature of phosphate addition, solved the problem, and rolled the fix into our main production line.
Clinical studies using animals noted a rise in background fluorescence during imaging. Working alongside their technicians, we assessed trace contaminants and installed extra activated carbon filtration, resulting in a marked drop in nonspecific signal. Those improvements didn’t originate in a boardroom—they came from ground-up collaboration with users putting the product through its paces and identifying needs others overlook.
Chemicals may seem benign at the right concentrations, but we know what slips through the cracks. Buffer solutions like PBS are relatively safe, but careless production or storage opens the door to biofilm formation and alteration by human error. We enforce a no-shortcuts mentality; bottles never move to fill unless every sanitization and pressure check shows green. Temperature logs capture everything, because sterility falls apart quickly above safe limits even if nominal “sterile fill” claims are met. We’ve seen the fallout from less rigorous outfits—contaminated cell lines, wasted grant cycles, and project delays.
Disposal gets overlooked, but we work with clients to design return and recycling protocols. A big university partner adopted our closed-loop packaging reuse scheme, reducing waste and costs while strengthening their compliance with local environmental standards. That sort of back-and-forth turns minor formulation changes or logistics tweaks into cost savings and smoother operations for everyone.
Field hospitals in disaster response zones use our PBS for critical sample prep. Logistics do not always allow for reliable refrigeration, and containers take a beating in transport. Through direct calls with logistics managers, we learned which packaging survived rough conditions, then ruggedized the bottle walls and introduced tamper-evident seals. The result: less waste, no contamination surprises, and smoother emergency medical operations. In another case, a stem cell therapy trial counted on real, documented sterility after another vendor's “sterile” buffer led to contamination. Their feedback shaped extra QC points in our SOP.
Every change goes through review, not in isolation, but by talking to end users who feel the frustration of failed experiments and the pressure of grant deadlines. Regular visits to academic clients and production audits at customer locations feed real-world lessons into our system. Over the years, this approach keeps PBS off the list of “possible variables” in experiments, letting researchers focus attention where discovery lives.
Our connection to the research and medical worlds runs deep, allowing us to stay close to change and challenge. Our operators pick up the phone and walk labs through troubleshooting if results go sideways, digging into batch records and, when necessary, sending out parallel samples to rule out source issues. People choose our PBS not just for what’s in the bottle, but for the support and transparent manufacturing behind it. Open-door audits are encouragement, not burden, because we believe trust builds with evidence, not just words.
We’ve hosted visiting scientists to walk our production floor, observe water purification runs, and see first-hand our batch control protocols. Many who arrive skeptical leave convinced—not by clever marketing but by seeing operators handle buffer tanks with the kind of care that comes from real knowledge and experience. Many of those same scientists return with new requests for format tweaks, bulk fills, or further improvements that turn into next year’s upgrades.
Lab science rarely fails in obvious ways; usually, it’s some minor factor—hard-to-pinpoint contamination or drift in ionic concentration. By keeping a tight rein on our PBS, we reduce the pool of “possible suspects” when things go wrong. Standardizing the lot and tracking every data point helps research teams write cleaner protocols and publish with greater confidence. The next time a tech grabs a bottle for a rinse or a prep, their mind’s on the science, not the buffer.
What sets our PBS apart is the relentless push for small, steady improvements. We look out for new regulatory changes, upgrades in analytical equipment, and shifts in the ways cell biology and molecular diagnostics use buffers. Sometimes it’s as simple as switching cap suppliers to eliminate rare leaks. Other times, we tweak sodium chloride sources after discovering subtle differences in trace ions, even when they’re not called out on standard tests. Direct engagement with QA and R&D chiefs at client sites drives these refinements.
Small differences in manufacturing add up when thousands of liters move through global labs. Our role as manufacturer isn’t to crank out undifferentiated bulk solution—it’s to supply trusted, predictable performance for people pushing the frontiers of biology, medicine, and diagnostics.
Our reputation stands on the buffers we produce and the relationships we nurture in the lab community. By obsessing over every variable, from water quality to the shortest logistics routes, we deliver phosphate buffered saline buffers that stand up to the rigors of daily research. Each batch carries the care not of anonymous factory lines, but of experienced, invested teams who know the impact of each bottle on experiments that make a difference.
This direct, ground-level perspective steers our work—backed by years on the production floor, thousands of hours troubleshooting in partnership with real researchers, and the outcomes achieved when small buffers play big roles. When you pick up one of our PBS, pH 7.4, Sterile bottles, you’re holding more than a commodity. You’re working with a partner as committed to quality as you are to your research.