HS Code |
861434 |
| Product Name | PAH Mix Standard |
| Supplier | Sigma Aldrich/Merck/TCL Chemical |
| Catalog Number | varies by supplier and specific mix |
| Chemical Class | Polycyclic Aromatic Hydrocarbon (PAH) Standard Solution |
| Number Of Components | varies, typically 6–16 PAHs |
| Solvent | usually acetonitrile or methanol |
| Concentration | typically 100–2000 μg/mL per component |
| Physical State | liquid |
| Intended Use | analytical standard for GC/HPLC |
| Storage Temperature | 2–8°C |
| Purity | certified reference material |
| Container Type | amber glass ampule or vial |
| Light Sensitivity | protect from light |
| Expiration | indicated on the label |
| Regulatory Status | for laboratory use only |
As an accredited PAH Mix Standard factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The PAH Mix Standard from Sigma Aldrich/Merck/TCI Chemical comes in a 1 mL amber glass vial with a secure screw cap. |
| Shipping | The PAH Mix Standard from Sigma Aldrich/Merck/TCI Chemical is shipped in secure, temperature-controlled packaging to ensure stability and integrity. It is classified as a hazardous material, so shipping follows strict safety regulations and may require special documentation. Ensure authorized personnel are available for receipt upon delivery. |
| Storage | The PAH Mix Standard from Sigma Aldrich/Merck/TCI Chemical should be stored in a cool, dry, and well-ventilated area, away from direct sunlight and sources of ignition. Keep the container tightly closed when not in use. Refrigeration at 2–8°C is recommended to preserve stability. Ensure storage in chemical-resistant containers and segregate from incompatible substances like strong oxidizers. |
Competitive PAH Mix Standard prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Experience in chemical manufacturing means living daily with detail, method, and responsibility. A PAH Mix Standard shapes so many analytic decisions in environmental labs, research institutes, and industrial quality control rooms. Polycyclic aromatic hydrocarbons (PAHs) show up wherever fossil fuels are burned—soils, water, air, even food matrices. Tracking, quantifying, and understanding these compounds hinges on robust standards. As producers, we know the headaches that unreliable reference mixes cause: inconsistent results, wasted instrument time, revalidation costs, and endless documentation headaches. Reliable PAH Mix Standards do more than save effort—they safeguard long-term environmental monitoring and workplace accountability.
Every bottle of our PAH Mix Standard comes out of a process built on redundant precision checks. No intermediary receives, breaks bulk, or repackages here. Our chemists weigh, dilute, and bottle the mix themselves, batch after batch. The raw materials, mostly high-purity single PAH crystals or powders, are chosen from lots where analysis confirms absence of isomers and residual solvents. For solvents, we stick to high-performance grades—usually acetonitrile or toluene, since these solvents elute cleanly with the widest set of detectors and work in both GC and HPLC methods. Our lot records track dates, weights, scales, purity statements, chromatogram printouts, and even glassware batch codes.
Hearing from customers, especially those running air quality programs or environmental forensics, teaches us where mixes can fall short. Some want just the 16 EPA-priority PAHs; others request custom blends matched to local soil risk profiles. All of them want a mix that won’t separate, crash out, or leak phenanthrene or benzo[a]pyrene onto a cap liner during months of storage. Out of that daily reality, our standard lineup covers the core US EPA 610 panel (naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenz[a,h]anthracene, benzo[ghi]perylene) at 100 μg/mL each, with options from 1 μg/mL up to 2000 μg/mL upon request
Model types correspond to mix ratios and intended application—routine environmental compliance, food monitoring, industrial hygiene, or research calibration. Our “PAH Mix Standard 610-16” serves most labs looking for a robust, EPA-aligned quantitation set. Customers tackling foodborne or thermal process contaminants sometimes request a modified blend, substituting methylated PAHs or priority nitro-PAHs, and our production lines support these without additional risk of cross-contamination. The difference stems from direct production; we do not tap external packers or third-party sources. No dilution steps or aliquoting occur anywhere but sealed cleanrooms, with full lot traceability.
Some of the biggest headaches in PAH standard preparation come from their tenacious hydrophobicity and glass adsorption. Lids inside each amber ampoule get selected for true chemical compatibility, and each batch ships with a full chromatogram, showing dozens of daily quality control runs. In our own work, trace oxygen and light exposure during weighing destroy certain sensitive PAHs, leaving quantification off by as much as 30%. So, all mastering and aliquoting happens under nitrogen or argon.
We do not outsource bottling or trust unknown supply chain steps. Batches are mixed in flasks reserved for PAH only; our analytic team runs split-and-post analyses regularly, comparing unopened ampoules to just-dosed ones to verify stability claims over six months or more. Some standards, ordered in larger glass bottles for high-throughput sites, demand added solvent to prevent precipitation. Syringe transfer under blanketing gas, fast capping, and sealed container checks are part of every day—not just a quarterly inspected routine.
Many labs rely on standard specifications that look good on a page but disappoint in practice. Purity levels on a data sheet mean little if isomer overlap isn’t separated or if residual metal ions catalyze breakdown. Our standards guarantee chromatographic separability across all 16 PAHs (or more for custom mixes), and each mix is run repeatedly through both GC-FID and GC-MS in our own labs. We’ve seen what happens when a mix labels 100 μg/mL but delivers only 83 μg/mL after a few weeks of dark storage. This can upend a year’s worth of routine monitoring or force teams to re-run hundreds of samples.
Bottle volume and concentration standards evolve not as marketing features, but out of repeated customer needs and honest error tracing. Typical vial volumes range from 1.2 mL up to 100 mL, none of which are partial volumes: we measure and fill every bottle under weight-based automation, with benzene-free paper records scanned and archived. Each mix undergoes repeated checks for photodegradation, solubility margin, and bottle integrity.
Work in environmental chemistry gives a front-row seat to the challenges that poor reference standards cause. A mix that precipitates after shipping creates waste and costs precious research time. We know analysts sometimes re-dissolve crystals in their own lab with surplus solvent, which can introduce biases. Our direct production line always focuses on keeping all PAHs dissolved through gentle agitation, careful solvent choice, and minimized cold exposure during handling.
Shelf life and true stability matter more than most data sheets admit. While “expiry dates” line up with typical laboratory compliance cycles, real stability varies with lab conditions. By storing at 2 to 8 °C in darkness, our mixes hold true concentration for at least one year from manufacture, and real-world client retestings show stability for two years or longer under the right conditions. More crucially, our team remains on call for questions about unexpected appearance changes, cloudiness, or off-color vials. Rarely, a standard can show micro-droplets at the bottom after repeated cap opening. This is never written off as cosmetic: every single return gets a full analytical review, since even a minor impurity can disrupt downstream data or instrument performance.
Some suppliers offer standards packed in generic bottles, with “traceable to NIST” labels that a lab technician can’t verify. Our direct production line grows from keeping everything in-house—from raw material screening to full packaging. We know each step, each instrument, and each lot of solvent, so if a single PAH looks low by area on a test report, we trace it back to the gram scale, master batch, or even the last acid-washed flask. This isn’t a matter of marketing. Our manufacturing roots run deep; too many years watching labs struggle with unclear labeling or fading calibration standards have shaped every production choice we make.
Standards from distributors sometimes take weeks to ship, passing through temperature cycles, warehouse shelves, and unknown repackaging steps. Our process minimizes these risks and leads to every ampoule or bottle arriving straight from our facility, freshly bottled. Bulk shipments come with refrigeration if required, and trackers document each shipping condition—because laboratories can’t lose time or data to surprise precipitates or contamination events.
While large trading houses follow bulk sourcing, they often lack the capacity to respond to one-off customer questions like “Why does this batch show lower than expected pyrene retention after 8 weeks at 4 °C?” Our analytic chemists answer directly—or even rerun QC in our production facility, not on the phone with an overseas source. In critical fields, this matters more than a standard catalog entry.
Anyone handling a PAH Mix Standard should treat it with respect: gloves, ventilated hoods, and careful documentation. The mix contains carcinogenic components, but decades of handling and our investment in precise mechanical workflows mean exposure risks stay minimized. Each standard comes not only with a paper chromatogram but also a digital scan of purity certificates and raw material analyses. Regulatory audits—unexpected and inevitable—never slow down when full documentation trails travel with the shipment, from weighing logs to solvent lot certificates signed by hand.
Auditors look beyond numbers. They scrutinize lab practices, backup records, and evidence of training. We supply method suggestions and troubleshooting notes already shaped by our own experience with noisy baselines or column bleed. Field teams often want reassurance over reactivity with various glass types, injection carryover, or photolysis risks under bench-top UV. Our support never leaves these questions to ready-made FAQ pages; decades of production and analytic use shape every response and suggestion. Data and record-keeping don’t just tick a compliance box—they protect future results and keep projects running through review after review.
Environmental research doesn’t stand still—neither do analytical standards. Regulatory updates, whether for soil pollution, food safety, indoor air monitoring, or industrial discharges, regularly drive requests for modified PAH mixes. Universities ask for odd-member compounds, alternate matrix solvents such as methanol or DMSO, or even isotopically labeled PAH internal standards. In our lab, custom requests get treated with the same care as our mainline products, drawing on the same solvent handling and purity verification protocols. No customer question lands on a distributor’s desk somewhere overseas; the same researchers who blend the mix answer the calls, share chromatograms, and review any request for nonstandard reference levels.
Not every request fits regulatory boundaries; sometimes labs want to develop their own detection or extraction protocol. Our team shares successful dilution and storage tips learned from years of prepping standards in field conditions, from Arctic air sampling missions to urban runoff analysis. The knowledge that comes from daily hands-on production shapes every bottle and reply.
In industrial hygiene and petrochemical compliance, direct accountability in chemical standards matters. Equipment calibration and cross-lab studies fail if standards aren’t consistent, stable, and fully documented. Our brewery, refinery, and plastics industry customers often face unique interferences—solvent carryover, metal ions, or even PAH byproducts at part-per-billion levels. Our standards follow up-to-date detection limits and retain performance even when labs use diverse instruments, from single quad GC-MS to LC-fluorescence detectors. If a single PAH shows unexpected degradation or fails to separate cleanly, our production chemists go back to batch records and raw material lots; every step gets re-checked and compared to original certificates of analysis.
Custom requests for matrix-matched standards—aqueous, oily, extraction-ready—receive the same attention to compatibility, solubility, and long-term container stability. We do not dilute a standard into unfamiliar solvents or pack off into generic glass; every new matrix type undergoes extensive solubility, freeze-thaw, and photostability checks before shipping. It is this approach, rooted in direct participation and ongoing collaboration with end users, that sets a direct manufacturer apart from trade resellers.
Fieldwork sometimes exposes new problems: broken vials after shipping, solvent loss under dry ice, or unexpected crystallization on arrival when outside temperatures swing. We regularly work with field teams planning Arctic or equatorial sampling to arrange alternate packaging—ampoule bottles, smaller glass, or rapid express shipments. Inside our facility, staff test batches across a range of freeze-thaw and temperature stress cycles; nothing leaves production unless glass, seals, and closures prove robust under routine field use. Returned containers undergo full analysis, and feedback gets worked back into both process and future recommendations.
If a PAH standard batch fails a stability check—cloudiness, drop-off in relative response, or visible precipitate after a storage test—the entire lot is pulled. Our team reruns new dilutions with fresh glass, updates QC documentation, and ensures no standard ships until quality recovers. This direct link between production, QC, and field feedback keeps product performance honest and transparent at every step.
Years of manufacturing PAH Mix Standards have shown how critical genuine in-house control and chemical expertise become for reliable product supply. Colleagues and customers rely on these standards to generate unambiguous results, whether for publishing research, confirming soil cleanups, or meeting strict food regulations. The risks and costs of a sub-par reference standard go far beyond the price of a bottle; they can derail months—or years—of important work.
Our focus—rooted in direct production, full in-house control, and day-to-day analytic use—means each bottle reflects decades of trial, learning, troubleshooting, and constant process improvement. From precisely weighed single-use ampoules to specialized, matrix-matched solutions, our PAH Mix Standards support laboratories facing new environmental and regulatory challenges every day. For those who need deep reliability, transparent documentation, and real expertise, a direct manufacturing partner makes all the difference.