HS Code |
754483 |
| Product Name | p-Nitrophenyl β-D-Glucuronide |
| Cas Number | 3767-28-0 |
| Molecular Formula | C12H13NO10 |
| Molecular Weight | 347.23 g/mol |
| Appearance | Off-white to yellow powder |
| Melting Point | 175-178°C (dec.) |
| Solubility | Soluble in water |
| Purity | Typically ≥98% (HPLC) |
| Storage Conditions | Store at 2-8°C, protected from light |
| Synonyms | 4-Nitrophenyl β-D-glucuronide, PNPG |
| Applications | Enzyme substrate for β-glucuronidase assays |
| Lambda Max | 405 nm (aqueous solution) |
| Supplier | Sigma-Aldrich/Merck/TCL Chemical |
As an accredited p-Nitrophenyl β-D-Glucuronide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | The packaging for p-Nitrophenyl β-D-Glucuronide (1g) from Sigma-Aldrich/Merck/TCI Chemical is a sealed amber glass vial. |
| Shipping | Shipping for **p-Nitrophenyl β-D-Glucuronide** (Sigma Aldrich/Merck/TCI Chemical) usually requires standard packaging in tightly sealed containers. It should be shipped at ambient temperature as a non-hazardous chemical, but protected from moisture and direct sunlight. Ensure compliance with local and international regulations for laboratory chemical shipments. Documentation accompanies the package. |
| Storage | p-Nitrophenyl β-D-Glucuronide should be stored in a tightly sealed container, protected from light and moisture. Keep at 2-8°C (refrigerator) as recommended by Sigma-Aldrich, Merck, and TCI Chemicals. Store in a well-ventilated, dry area away from incompatible substances. Ensure proper labeling and avoid exposure to direct sunlight and high temperatures to maintain stability and quality. |
Competitive p-Nitrophenyl β-D-Glucuronide prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
During day-to-day production, our chemists see trends come and go, but the need for solid analytical substrates remains unchanged in enzyme and microbiology labs. p-Nitrophenyl β-D-Glucuronide holds its place on the bench for good reason. It’s a synthetic, chromogenic substrate most often recognized for its role in β-glucuronidase detection, a key enzymatic indicator in water quality testing and clinical diagnostics. Our facility crafts this compound under tightly controlled conditions, with attention paid personally to batch consistency, purity, and crystalline stability. Through years of hands-on experience, we have refined the process to minimize impurities and maximize yield, knowing that labs depend on substrates that won’t fail mid-assay.
Our current process delivers p-Nitrophenyl β-D-Glucuronide as a fine, off-white to pale-yellow crystalline powder. Typical purity exceeds 98 percent, as verified by HPLC and NMR in our in-house laboratory. Molecular formula is C12H13NO9, with a molecular weight close to 331.23 g/mol. Every batch also undergoes a spectral check to confirm that the signature UV absorption at 405 nm appears sharp. Shelf-life assessments run out far beyond two years when the powder stays sealed and protected from moisture, reflecting both methodical drying and robust packaging. We ship the product in amber glass containers to block light, and always suggest that users store it at 2 to 8°C, away from reactive chemicals, to prevent hydrolytic degradation. Loss of substrate quality often tracks back to improper storage conditions, so we reinforce this advice with every outgoing order.
Often, end users preparing this substrate for enzymatic assays ask what concentration provides the cleanest color readout. From what we’ve worked with internally and field tested along with research partners, a working solution in aqueous buffer at 1–5 mM produces a clear, measurable yellow chromophore (p-nitrophenol) after enzymatic cleavage. This color development forms the basis for both endpoint and kinetic measurements of β-glucuronidase activity. Water testing facilities have adopted these assays for routine screening of E. coli contamination in recreational, municipal, and bottled water supplies. The rapid visual transition and reliable absorbance values at 405 nm give assay operators a high degree of confidence, much preferred over less consistent alternatives such as fluorogenic or turbidimetric substrates.
Clinical researchers also lean on this compound for diagnostic work exploring enzyme deficiencies or for therapeutic monitoring. Since beta-glucuronidase activity in human samples can provide clues to various metabolic or infectious conditions, clinicians want a substrate that minimizes background interference and false positives. We’ve learned through direct feedback that our product’s controlled impurity profile results in low background color, a trait that matters even more in low-enzyme contexts where every millicolor unit can shift a diagnosis. In automated analyzers, the crystalline form dissolves rapidly without leaving gritty residue, supporting clog-free operation throughout lengthy runs.
The chemical synthesis of p-Nitrophenyl β-D-Glucuronide relies on well-honed glycosylation techniques, starting with regioselective protection of glucuronic acid derivatives and careful coupling to p-nitrophenol. Our manufacturing runs use only high-purity solvents and glass-lined reactors, minimizing exposure to catalytic residues. Clear-cut drying regimens, pressure filtration, and final crystallization steps give us a material free from both organic and inorganic contaminants above trace thresholds. High-purity water systems and HEPA-filtered cleanrooms prevent airborne contamination during final packaging. These details may sound granular, but every single step prevents batch-to-batch variation that would throw off sensitive colorimetric assays run in downstream labs.
Comparisons often pit this substrate against p-nitrophenyl β-D-galactoside, methylumbelliferyl substrates, and X-glucuronide. Our bench chemists have prepared and used all of these, but substrate selection rarely depends solely on budget or protocol legacy. For example, p-nitrophenyl β-D-Galactoside targets β-galactosidase, not β-glucuronidase. Over the years, users switching between galactosidic and glucuronidic substrates have reported that while both can deliver clean spectrophotometric signals, the p-Nitrophenyl β-D-Glucuronide system stands out for its low spontaneous hydrolysis in buffered conditions below pH 7. This means less background absorbance and more reliable detection of faint enzyme activity—key in environmental screening, where false positives lead to costly secondary testing.
Methylumbelliferyl glucuronide, a fluorogenic probe, offers higher sensitivity in some designs, especially on plate readers with deep UV capability. Yet, many labs equipped with standard photometers prefer p-nitrophenyl substrates due to the visible yellow end-product and less specialized detection equipment. This has direct cost and training implications. Our product offers high substrate stability in aqueous solutions up to at least several hours, where other labile options lose signal due to hydrolysis. Customers with high throughput systems recognize that this stability translates to less frequent reagent prep and lower error rates in result interpretation.
Switching attention to X-glucuronide, used for blue-color formation in histochemical or microbial media, some labs prefer this for direct agar plate screening. X-glucuronide’s blue reaction isn’t as easy to quantify as the sharp absorbance from the p-nitrophenyl system. We consistently hear from water testing facilities that the visible yellow output of p-nitrophenol delivers particularly clear, reproducible endpoint results when testing for E. coli, where ambiguity delays reporting. Beyond water testing, tissue sections in research settings show little benefit from p-Nitrophenyl β-D-Glucuronide, but the compound’s colorimetric clarity gives it an edge for spectrophotometric quantification in solution.
In our own lab, we validate every incoming batch of p-Nitrophenyl β-D-Glucuronide using both chemical and functional methods. Trial reactions with reference β-glucuronidase confirm substrate turnover rates, peak development times, and signal-to-noise characteristics. This extra step, though not technically required, reflects our direct engagement with the needs of field users who rely on these details for robust assay design. Knowledge from our own test runs also informs direct customer support when troubleshooting unexpected results—if precipitation or slow color development crops up, we draw from our internal runs to suggest fixes, ranging from buffer pH adjustments to filtration technique tweaks.
Not every substrate supplier takes this hands-on, iterative approach. Some see supply as just packing and shipping; we embed chemical expertise into every lot by training staff to recognize subtle changes in crystal habit and aging behavior. Early on, we encountered an issue with slight browning in long-term cold storage. Final root-cause analysis pointed to trace residual solvents, so we added one more vacuum drying cycle. Post-implementation, browning incidents flatlined, and customer complaints faded. Adjustments like this shape our product’s reputation for reliability.
Throughout the business, market demand pressures manufacturers to lower costs and speed up turnover. Behind the scenes, the main drivers of price surges are rising costs from raw materials—sugars, acids, and specialty reagents. To contain these, we’ve worked with suppliers to source only those able to verify low contaminant profiles by batch. Monitoring environmental controls in our plant keeps word-class water and air quality, minimizing downstream purification hurdles and waste. For years, we have recycled solvent streams where chemistry allows, reducing overall waste and cost without cutting corners on process controls.
In line with updated local and international chemical safety requirements, every batch ships with complete analytical documentation, allowing end users to satisfy auditors and inspectors. We run full metal contaminant screening and provide detailed characterization data on request. While not always mandatory, detailed transparency gives researchers and municipal labs peace of mind, particularly where regulatory scrutiny of water and clinical diagnostics runs high. Implementation of barcode tracking ensures traceability back to the supply lot, giving users additional confidence and enabling rapid, targeted recall should an issue ever arise.
Making p-Nitrophenyl β-D-Glucuronide at scale did not happen overnight. Early, small-batch syntheses revealed bottlenecks in both reaction step yield and purification that, if left unaddressed, would have left us unable to supply growing demand. Through iterative experimentation—refining reagent ratios, swapping out solvent blends, tuning cooling regimens—we found ways to streamline the process and lift throughput while still hitting purity benchmarks. Every process tweak is monitored by both chemical analysis and user feedback. One example: after an uptick in requests for extra-dry substrate, we implemented a lyophilization stage post-synthesis, slashing ambient moisture pickup. This step now forms a core part of our production protocol and delivers long-term shelf stability even in warm, humid climates.
Researchers and water monitoring agencies share their practical pain points with us, and these conversations shape our refinement efforts. Some labs found their standard buffer recipes led to slower color formation; technical back-and-forth revealed key differences in local water composition—magnesium and calcium ions in some sources were binding substrate and slowing reaction rates. Process changes, including alternate buffer recommendations and direct shipment of substrate pre-dissolved in anhydrous solvents, rose from these dialogues. Our role does not end at delivery; on-call chemists respond to queries about troubleshooting, storing, or adapting protocols to meet unique regulatory or research constraints.
Years of delivering specialty chemical substrates instills a cautious, meticulous mindset in both the lab and plant floor staff. Any sign of deviation from normal—clumping, off-color, unexpected residue—triggers a halt and re-review by both QC chemists and production management. This vigilance translates to lower risk in client labs, especially those running critical environmental or clinical tests. We know—through direct feedback and routine site visits—that receiving inconsistent batches means lost trust, delayed results, and wasted expense on revalidation. Our commitment to rigorous, visible quality control, and willingness to adapt packaging or documentation formats in response to changing compliance frameworks, underpins both our reputation, and customers’ confidence in the assay system as a whole.
Demands on substrate performance keep evolving. Digital automation and data-driven workflows increase throughput, putting pressure on both upstream manufacturing and downstream analytical equipment. Our R&D unit experiments with solubility modifiers and stabilizing additives, guided by both chemical insight and ongoing conversations with equipment vendors and leading research labs. These joint development projects drive subtle but valuable improvements—longer working solution lifetimes, wider pH ranges, and higher tolerance to impurities in sample matrices. Newer, greener process steps are under constant review as regulatory environments tighten, particularly on solvent use and waste disposal. Our goal is to deliver a product that matches or exceeds researcher expectations for purity, consistency, and environmental stewardship.
Through close partnership across the chemical, water analysis, and diagnostics sectors, we have seen p-Nitrophenyl β-D-Glucuronide prove its value as a reliable, sensitive tool for enzyme detection. Chemists work daily to maintain and improve output, drawing on evidence from internal testing, field reports, and collaborative trials. Our approach roots itself in practical knowledge and transparent, open-ended communication with users across industries. By integrating experience, technical skill, and real-time feedback, we aim to ensure every vial supports dependable, meaningful results—under the most demanding laboratory conditions.