West Ujimqin Banner, Xilingol League, Inner Mongolia, China sales7@bouling-chem.com
Follow us:

NBD-PZ (=4-Nitro-7-piperazino-2,1,3-benzoxadiazole) [for HPLC Labeling]

    • Product Name NBD-PZ (=4-Nitro-7-piperazino-2,1,3-benzoxadiazole) [for HPLC Labeling]
    • Alias NBD-PZ
    • Einecs 609-587-1
    • Mininmum Order 1 g
    • Factory Site West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry sales7@bouling-chem.com
    • Manufacturer Bouling Chemical Co., Limited
    • CONTACT NOW
    Trusted Payment Partner
    Secure transactions supported by VTB Bank for reliable B2B procurement worldwide.
    Specifications

    HS Code

    173837

    Name NBD-PZ
    Synonym 4-Nitro-7-piperazino-2,1,3-benzoxadiazole
    Molecular Formula C10H10N6O3
    Molecular Weight 262.23 g/mol
    Appearance Yellow solid
    Cas Number 98182-44-6
    Solubility Soluble in DMSO, DMF, and methanol
    Purity Typically ≥98% (HPLC)
    Use HPLC labeling reagent for amines
    Storage Temperature 2-8°C
    Absorption Maxima 470 nm (in methanol)
    Smiles O=[N+]([O-])c1cc2n(nc1)nc(cc2)N3CCNCC3
    Sensitivity Sensitive to light
    Melting Point 140-142°C
    Hazard Class Irritant

    As an accredited NBD-PZ (=4-Nitro-7-piperazino-2,1,3-benzoxadiazole) [for HPLC Labeling] factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing NBD-PZ is supplied in a 25 mg amber glass vial, securely sealed and labeled, to protect from light and ensure chemical purity.
    Shipping NBD-PZ (4-Nitro-7-piperazino-2,1,3-benzoxadiazole) for HPLC labeling is shipped in tightly sealed, light-protective containers to maintain chemical stability. The package is cushioned and labeled according to regulatory standards, and transport is via temperature-controlled carriers, compliant with appropriate chemical shipping regulations for laboratory-grade reagents.
    Storage NBD-PZ (4-Nitro-7-piperazino-2,1,3-benzoxadiazole) should be stored in a cool, dry, and well-ventilated place, away from direct sunlight and incompatible materials such as strong oxidizers. Keep the container tightly closed when not in use. Store at 2-8°C (refrigerated). Protect from moisture and light to maintain product stability, as recommended by suppliers like Sigma Aldrich, Merck, and TCI.
    Free Quote

    Competitive NBD-PZ (=4-Nitro-7-piperazino-2,1,3-benzoxadiazole) [for HPLC Labeling] prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615371019725

    Email: sales7@bouling-chem.com

    Get Free Quote of Bouling Chemical Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    NBD-PZ: 4-Nitro-7-piperazino-2,1,3-benzoxadiazole for HPLC Labeling

    Transforming HPLC Fluorescent Labeling in Practice

    Every technical lab chasing clear, sensitive chromatograms has faced the puzzle of amine detection. Over the years, we’ve worked closely with principal investigators, research chemists, and analysts looking for sharper separation and real answers about their molecules. As a chemical manufacturer, we have seen how 4-Nitro-7-piperazino-2,1,3-benzoxadiazole, known simply as NBD-PZ, meets this demand in a way that stands out from the usual labeling compounds.

    NBD-PZ’s unique reactive moiety attaches cleanly to primary and secondary amines—even in complex mixtures—without introducing detection ambiguity or shifting peak retention times unexpectedly. Any lab that’s wrestled with background interference on an HPLC, or had to redo sample prep for low-abundance peptide quantitation, quickly notices how much difference the unambiguous fluorescent tagging from NBD-PZ delivers.

    The Composition We Stand Behind

    Our NBD-PZ is synthesized with robust modern process control, using high-purity raw materials and constant in-house monitoring of byproduct loads. What comes out of our facility is a yellow crystalline powder, with purity consistently verified by HPLC and NMR. Contaminants, trace moisture, and unreacted starting materials complicate HPLC fluorescence output—by eliminating those, we help labs skip extra cleanup, conserve reagent, and avoid added purification steps. This reflects a trend in our sector: more chemists want labeling compounds that meet instrument-grade requirements right out of the bottle, not after repeated reprocessing.

    We ship NBD-PZ with a minimum assay of 98% by HPLC, and most lots register above 99%. High batch reproducibility matters; small variations in impurity content can dramatically affect background fluorescence and labeling reliability, especially when detectors calibrate to sub-nanomolar ranges. Our close relationships with chromatography method developers guided us early to focus on producing consistent NBD-PZ, allowing customers to run their established protocols without recalibrating or troubleshooting each new lot.

    Why the Benzoxadiazole Core Changes the Game

    Many commonly used HPLC amine labeling reagents utilize naphthalene or anthracene derivatives, which drive label stability but often come with drawbacks. The 2,1,3-benzoxadiazole scaffold in NBD-PZ combines a compact molecular footprint with intense fluorescence response, yielding strong emission in the visible range and supporting detection down to picomole levels. Bench chemists and analysts benefit from this increased sensitivity, which captures analytes that might otherwise slip through detection thresholds.

    Additionally, NBD-PZ exhibits chemical stability against hydrolysis and photo-bleaching, reducing the risk of inconsistent chromatograms during sample workup or storage. We frequently hear from pharmaceutical research labs and food safety institutes that standard labeling reagents can degrade if samples queue up too long in the autosampler or are exposed to ambient light. With NBD-PZ, the labeled analytes maintain their integrity, saving time and cutting uncertainty around sample handling logistics.

    Applicable Use Cases Backed by Real-World Feedback

    Through years of direct customer feedback, we’ve learned where NBD-PZ excels. Protein sequencing specialists rely on its precision when labeling amino acids prior to HPLC, where a single misidentified peak can lead to erroneous conclusions about sequence or composition. Environmental chemists applying NBD-PZ for polyamine detection in water samples appreciate the minimized sample preparation steps—no lengthy derivatization at elevated temperatures or excessive buffer exchanges. The mild conditions required for NBD-PZ conjugation reduce sample loss, particularly for thermolabile or dilute specimens.

    Constant demand from food and nutraceutical testing labs has cemented NBD-PZ’s reputation for reliable, batch-to-batch amine analysis. Applications include quantification of biogenic amines in beverages, detection of drug impurities, and veterinary residue monitoring. Throughout these fields, labs report improved signal-to-noise ratios and less tailing or doublet formation—a testament to how the piperazino group in NBD-PZ ensures a clean, selective reaction profile.

    Differentiation from Other Labeling Agents

    Competition among HPLC labeling agents remains intense, with o-phthalaldehyde (OPA), dansyl chloride, and fluorescamine most commonly cited as alternatives. From extensive method development side-by-side in our application labs, several specific differences became clear:

    From the practical side, sample clean-up is streamlined, thanks to the high aqueous solubility of both NBD-PZ and its fluorescent products. Analysts can work directly in standard HPLC buffers and organic mixtures without complicated solvent exchanges, and this speeds up everything from sample prep to column loading to waste disposal.

    Consistent fluorescence intensity across the linear range is essential for quantitative applications; with NBD-PZ, calibration curves stay tight from low-picomole up through saturating levels, avoiding the tail-off in sensitivity seen with some less robust labeling agents. Application notes submitted by our network of partner labs confirm that even after repeated sample cycles, fluorescence output remains stable without the drift seen from less durable labels.

    Practical Advantages for Analytical Performance

    The optical performance of NBD-PZ matters most when working with multi-channel detectors. The absorption maximum (excitation) of NBD-PZ-labeled products sits conveniently near 470 nm, and emission peaks around 540-550 nm. Instrument manufacturers have standardized filter blocks and lamp sources around these values, making integration into existing HPLC systems seamless. This spectral window also avoids overlap with background autofluorescence common in biological and environmental matrices.

    Labs often run into trouble using labeling reagents with poorly matched spectral windows, where native background fluorescence can mask weaker analyte peaks. Since we established our current process, feedback from method validation teams supports what our bench-scale runs showed early: with NBD-PZ, blank runs stay noise-free and true analyte peaks show sharp, reproducible retention. This saves teams from burning valuable instrument time on failed runs or ambiguous data sets.

    Scaling up from research to production also reveals NBD-PZ’s strengths. Manufacturing-scale QC departments running hundreds of samples daily benefit from the quick derivatization and short cleanup. For multiplexed analysis or automated workflows, label consistency and derivative stability mean fewer re-runs and faster batch clearance.

    Supporting Innovation in Modern Chromatography

    As regulatory bodies tighten reporting standards for drug residues, environmental pollutants, and food safety contaminants, analytical labs need reagents that deliver not just sensitivity but also documented precision and traceability. We invest in batch-level documentation, with lot-specific certificates verifying every shipment. On-site regulatory inspections and customer audits point to the importance of documentation: analytical chemists and QA leaders want full traceability from synthesis to labeling, so that every unknown peak can be mapped, audited, and explained.

    After more than a decade supporting method development for pharmaceutical, agricultural, and environmental contracts, we have observed that short supply chains and direct lot documentation build user confidence. Through lean manufacturing and strict in-process control, we align our processes to these expectations. Every container of NBD-PZ from our lines leaves the plant with full batch certification, matching the transparency and reproducibility expectations that accredited labs require.

    Lab managers cite ‘unknowns in the blank’ as a recurring roadblock during third-party audits. Unmarked impurities or cross-reaction byproducts undermine trust in the labeling step. With each new product lot, feedback from reference labs and customer audits feeds directly back into our QC loop, so we can continue to minimize batch-to-batch variability and keep impurity loads far below industry thresholds. Much of our reputation among regulatory agencies comes from this open, iterative communication and our direct oversight of all manufacturing steps, from synthesis through final packaging.

    Safety, Clean Handling, and Reduced Downtime

    Anyone responsible for daily lab safety or environmental compliance knows that labeling agents can introduce handling risks or complicate routine cleanup. NBD-PZ’s solid-state format and low volatility simplify weighing and dissolution. Past issues with powder dispersal and cross-contamination during reagent weighing have become rare thanks to a granular particle size and low dusting. Packaging meets compatibility standards for both short-term lab bench use and long-term cold storage, leading to fewer handling incidents reported within customer facilities.

    Labs operating under strict health and safety regimes appreciate that NBD-PZ lacks noxious odors and presents negligible volatility at room temperature. Because there are no hazardous gases or aggressive solvents needed for the derivatization step, routine sample processing is safer and more comfortable—even during long sample queues or overnight automation cycles. Safety managers regularly mention these features when comparing their reporting burdens against reagents with lower flashpoints or higher toxicity profiles.

    We routinely review safety incidents and process feedback from contract research organizations and in-house quality teams. These reviews have driven several incremental packaging improvements, including tamper-evident seals and resealable options, all tested for compatibility with automated dispensers and liquid handlers. The result is a more streamlined lab workflow—less wasted reagent, fewer weighing errors, and less time handling open containers on the benchtop.

    Real-World Results from Collaborative Development

    From day one in bulk supply, chemists have reached out to share both challenges and benchmarks. Early pharmaceutical clients asked about label hydrolysis under storage; food labs questioned sensitivity on high-sugar backgrounds; regulatory scientists requested documentation for unknown impurity tracking. Our in-house chemists and technical application teams remain an ongoing resource for consultation, answering protocol questions and guiding troubleshooting for new or specific analytical setups.

    Direct interaction helps us refine batch characteristics. As an example, research groups running peptide mapping protocols sometimes found traditional labels dropped signal or introduced extra peaks after sample hydrolysis. With NBD-PZ, the conjugates stay intact under acidity or moderate base. Analysts checking instrument response for trace biogenic amines in clinical research brought up matrix/solvent compatibility issues; our ongoing solvent compatibility improvements made it possible for users to reduce background, saving hours on repeated baseline corrections.

    Supporting this feedback-driven approach, our R&D group invests in method notes and sample chromatograms for evolving use cases. Our test collaborations, conducted hands-on at partner sites, go deeper than simply sending out a datasheet. Joint testing with beta sites—public and private—has led directly to workflow improvements and protocol updates that continue to benefit the broader user community.

    This partnership-based model steers all our product design and QC. Every challenge—from sample longevity questions to batch competitiveness against the fastest-reacting labels—feeds directly into real manufacturing changes, prototype iteration, and next-generation formulation testing.

    Addressing Current Sector Challenges

    Chromatography labs today face a tighter squeeze on run times, higher sample throughput expectations, and stricter standards on detection reliability, often with leaner staff and instrument downtime windows. A successful fluorescent label needs to help instrument operators, analysts, and method developers meet these rising standards day to day. We’ve seen the market evolve: the push now is towards compounds that bring direct, reproducible performance, cut extra cycles, and offer rigorous batch accountability on paper and in practice.

    One core challenge lies in scaling workflows under shifting regulatory guidance. Method transferability and flexible validation become critical, especially for labs handling multi-center studies or pharmaceutical manufacturing. Many partners find that a single, highly consistent label shifts the entire HPLC workflow from development to routine testing, reducing ‘false flags’ and calibration headaches. NBD-PZ’s tight batch control and full documentation close the gap between research-grade sensitivity and production-scale trustworthiness.

    Pushing Forward—What’s Next in Fluorescent Labeling

    Application chemists increasingly seek expanded compatibility for automated high-throughput systems, where ease of solvent handling, storage stability, and reaction reliability represent the competitive edge. At the same time, environmental and toxicology research continues to demand labeling agents with lower environmental signatures and ever-declining impurity profiles.

    We continue to innovate based on both user-driven and regulatory trends. In practice, this means improving both synthetic efficiency and waste minimization during manufacture—cutting unwanted byproducts, streamlining batch purification, and developing packaging that fits seamlessly into pipetting automation or direct-to-cartridge setups. Each feedback cycle gives our internal R&D team new priorities, often leading directly to product enhancements that arrive in production cycles within weeks, not quarters or years.

    By remaining hands-on at every stage—sourcing, synthesis, purification, application—we pursue practical advancements in labeling chemistry. Commitment to analytical transparency links every lot, every certificate, and every protocol update back to a rigorous, traceable manufacturing process. We share ongoing data and protocol guidance with our partners, building new performance benchmarks for HPLC fluorescent labeling reagents.

    Conclusion: Real-World Tools Built for Modern Labs

    NBD-PZ defines the current high point in reliable, sensitive, and reproducible fluorescent labeling for HPLC. Built through direct experience and refined by continuous real-world input, it brings laboratories a reagent that enhances data confidence, speeds up sample turnaround, and meets both present and future analytical challenges. Our doors remain open to every technical suggestion, every benchmark challenge, and every evolving workflow—real improvements come from the ground up, in partnership with those who run the machines, analyze the peaks, and set the standards day after day.