|
HS Code |
382733 |
| Cas Number | 59-89-2 |
| Molecular Formula | C4H8N2O2 |
| Molecular Weight | 116.12 g/mol |
| Appearance | Yellow oily liquid |
| Boiling Point | 222 °C |
| Melting Point | -60 °C |
| Density | 1.159 g/cm3 |
| Solubility In Water | Very soluble |
| Vapor Pressure | 0.09 mmHg at 25 °C |
| Flash Point | 93 °C (closed cup) |
| Synonyms | NNM, NMO, Morpholine nitrosamine |
| Ec Number | 200-431-4 |
As an accredited N-Nitrosomorpholine factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | N-Nitrosomorpholine (Sigma Aldrich, 25g): Supplied in an amber glass bottle with hazard labeling, screw cap, and chemical-grade specification details. |
| Shipping | N-Nitrosomorpholine is shipped in tightly sealed containers, protected from light and moisture, according to strict hazardous materials regulations. It is classified as a toxic and carcinogenic substance, requiring clearly labeled packaging, secondary containment, and temperature control. Shipping complies with international transport regulations (IATA, DOT, IMDG) and institutional safety policies. |
| Storage | N-Nitrosomorpholine should be stored in a tightly closed container in a cool, dry, and well-ventilated area away from heat and sources of ignition. Keep away from incompatible materials such as strong acids and oxidizers. Protect from light and moisture. For Sigma Aldrich, Merck, or TCI grades, ensure the storage area is suitable for carcinogenic and toxic chemicals, with proper labeling and restricted access. |
Competitive N-Nitrosomorpholine prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
At our manufacturing plant, producing N-Nitrosomorpholine isn’t just routine business—it is a responsibility that rests on the shoulders of every team member, from the operators in the synthesis area to the quality manager overseeing each batch lot. Over the decades, we've seen how the role of specialty chemicals continues to evolve, and N-Nitrosomorpholine (commonly abbreviated as NMOR) captures that balance between scientific rigor and practical utility. For years, research institutions, chemical evaluators, and standards organizations have turned to us for reproducible quality and reliable supply, so our commentary reflects the realities of daily operations and honest feedback from those who use these materials for demanding applications.
N-Nitrosomorpholine, with the chemical formula C4H8N2O2, often arrives as a light yellow liquid under room temperature conditions. Its UV absorption profile, high solubility in both water and a range of organics, and distinct volatility make it stand apart in both analytical and industrial sectors. Laboratory teams preparing calibration curves for nitrosamine analysis often select it as an internal standard because of its stability and response factor reproducibility during GC or LC testing. That stability doesn't come about by chance. Strict control in storage, bottling, and dispatch minimizes unwanted decomposition or cross-contamination. If the logistics chain or packaging shortcuts, the material's trace impurity profile shifts, leaving researchers wrestling with unexplained calibration errors or lost sensitivity.
Unlike commodity chemicals where batch variance runs higher and specs may focus mainly on purity by weight, NMOR sits in a more scrutinized category. Production targets a minimum purity of 99% verified using chromatographic and spectroscopic methods with trace-level impurity monitoring. Our routine tests span GC-FID, HPLC-UV, and NMR screening, especially to check for the presence of related nitrosamines, morpholine, and water content. We control water levels below 0.1% to reduce hydrolytic instability. Density and refractive index matching fall within tightly held bands, usually tested against reference lots every cycle.
Packaging presents its own set of dilemmas. Metal containers risk catalyzing unwanted reactions over extended periods, so we switched to high-integrity, dark borosilicate glass that holds up to regulatory stability standards while limiting polymer degradation or leaching. Label accuracy, tamper evidence, and QR traceability for audit trails serve as more than compliance measures—they form a chain of custody that leading researchers expect. Batch records extend back well over ten years, a depth of recordkeeping that saves headaches for university consortia or pharma analytical chemists asked to reconstruct historic sample performance.
Much of the debate about NMOR traces to its usefulness as a reference standard and environmental marker. Analytical labs select it as a performance reference to calibrate nitrosamine analysis, especially in water safety monitoring and trace analyte measurement projects. Not all nitrosamines share the same calibration response, and among them, NMOR delivers consistent, sharp chromatographic signals and fewer interfering byproducts during common method runs.
Environmental surveillance groups often depend on our NMOR to check municipal water for nitrosamine contamination, reflecting regulatory shifts that push towards ever-lower detection limits. Our ongoing collaboration with European and Asian regulatory labs means our process adapts quickly to tighter nitrosamine limits or analytical method development, especially as detection moves from the ppb to the sub-ppb range.
Academic and regulatory collaborations have driven our choice of manufacturing mode. Several researchers share feedback on batch-to-batch consistency, and that often points back to the raw morpholine feedstock. We select feedstock with certificate-accompanied impurity listings and supplement our own incoming inspection with infrared and GC-MS spot checks. The only way to maintain acceptable blank baselines in validation reports starts with tight raw material checks at the gate. End users—ranging from environmental analysts to pharmaceutical chemists—report that our material reduces time spent troubleshooting background interference.
Long-term exposure studies and toxicology research lean heavily on NMOR, given its listing among model N-nitrosamines with documented cancer-related research. Our plant teams received ethics briefing from environmental scientists before ramping up production, underscoring our belief that transparency and traceability are non-negotiable in producing biorelevant research chemicals. When we receive requests to support multi-year exposure studies, we maintain retention samples for as long as regulators or research partners require.
Manufacturing, bottling, and shipping NMOR mean constant vigilance. Few outside the sector realize the precautions required to handle this family of chemicals. Teams rotate through updated safety training, engineering controls, and monitoring for accidental emissions. Every production cycle uses local exhaust ventilation and dedicated personal protection, always double-checked before run startup. We invest in closed transfer lines and continuous air monitoring—protocols fueled by practical lessons, not just regulations.
Years ago, we learned painful lessons about risk by reviewing near-miss incidents. Unchecked open lines, poor bulk storage, or outdated exposure calculations can escalate into real harm. Facility layout now segregates nitrosamine processes from less hazardous compounds, and all cleaning protocols receive third-party validation before re-certifying shared equipment.
Waste minimization plays a parallel role. All spent solvents and mother liquors containing nitrosamines are incinerated off-site under condition-verified contracts; there’s no margin for shortcuts or loopholes. We publish annual audits detailing destruction tracking by lot, and if incidents arise in our logistic network, corrective reports ensure lessons are shared, not buried. We consult often with regional authorities on lifecycle planning, and this hands-on approach pushes improvements year after year.
Chemical manufacturers often get lumped together in broad product lists, but there are critical differences among nitrosamines and between NMOR and other representatives. N-Nitrosomorpholine remains less lipophilic and less volatile than, for instance, N-Nitrosodimethylamine or N-Nitrosopyrrolidine, which affects their ease of detection and risk management plans. Analytical groups frequently email us to review signal baselines from different nitrosamine internal standards. NMOR stands out with its higher water compatibility. That compatibility means fewer solubility issues during sample prep and sharper signals for trace analysis, critical in monitoring projects with tight detection limits.
Our in-house experts work through these attributes, producing NMOR with well-documented chromatograms that show lower tailing and side-product drift than competitor batches. Consistency in refractive index, density, and purity levels don’t just look good on paper—they quickly reveal differences in day-to-day lab work. Researchers have remarked that switching to our product resolved persistent calibration issues. Their feedback shapes our process improvements, and we understand that real performance happens in application, not just at the QA bench.
Unlike many general lab-grade chemicals, NMOR presents both elevated risk and higher reward for consistent manufacturing. Any deviation generates regulatory and reputational fallout. We see requests for certificates that go beyond a basic certificate of analysis; method validation data, batch stability tracking, and random retesting explain why clients return year after year. We don’t treat NMOR as a checkmark chemical—it is a standard that sets the tone for our broader responsibilities.
Open lines of communication with research partners, industry consortia, and government labs drive continual improvement. After sharing comparison studies between our NMOR and imported lots, environmental labs in North America asked for expanded batch documentation on related volatiles. Our technical team revised both raw material approval cycles and in-process checks as a result, incorporating suggestions based on field data.
Not every challenge comes from outside. Over time, changes in raw material markets forced us to revisit supplier selection policies, a lesson learned from the aftermath of a wildly fluctuating morpholine market. Where some competitors bank on price swings or spot buys, our process depends on long-term sourcing agreements with stable partners. Rigorous batch testing at intake, not just at dispatch, avoids the perils of assumptions and maintains uniform product quality. Our procurement staff sit face-to-face with suppliers, walking through documentation and visiting production sites for direct oversight.
New regulations around nitrosamine trace limits, especially in pharmaceuticals, push us to respond quickly instead of waiting for harmonized international guidance. Direct engagement with industry standard-setting bodies ensures our testing protocols stay ahead of curve, preemptively adding new targets to routine impurity screening. By maintaining open discourse across regulatory, scientific, and industrial lines, we help shape industry norms, not just follow them.
NMOR synthesis depends on precise reaction conditions. Production teams monitor temperature, pressure, and feedstock ratios with every batch, but real-world challenges still emerge. We’ve encountered situations where minor deviations in pressure or reaction time led to byproduct formation detectable only with highly sensitive GC-MS. The downstream impact isn’t abstract—it creates costly rework and possible lost lots. By archiving these process deviations and integrating process analytical technology, we track and respond to trends before drift sets in.
Every plant has grappled with cross-contamination fears, especially in mixed-use facilities. Strict campaign scheduling—allocating days solely for nitrosamine operations—and investing in CIP (clean-in-place) validation reduce the risk of carryover. Not every manufacturer makes that investment due to the downtime it produces, but we pointedly take those extra hours to ensure there’s no residue between batches. Our on-site chemists have real authority to halt processes if specifications slip, and we treat near-specification results as trigger points for deeper investigation, not just checklist passes.
Customer expectations form a parallel source of pressure. Each time a user flags an out-of-specification result, we work trace backs through every potential root cause, including climate-controlled shipping week by week. A recent spike in customer inquiries about long-haul shipping led us to trial new secondary containment and track in-transit temperature fluctuations. Early results show better retention of volatility-sensitive properties on arrival, which our QA data corroborates.
Our view of chemical stewardship stretches far beyond batch lots. For society to trust those who handle hazardous and high-impact chemicals, manufacturers must go beyond minimum standards and step up as transparent partners. Detailed reporting to regulatory agencies occupies a major part of our compliance workload, and we accept inspection from a range of local and international authorities. We share annual performance and safety data in public reports. Supply chain transparency—tracking raw material to finished bottle—remains central, ensuring a cycle of accountability.
Our laboratory’s outreach to academic partners drives new method validation and environmental impact studies. Grant-supported research teams rely on predictable supplies of NMOR for projects ranging from drinking water analytics to carcinogenicity reference models. This direct link with the research community helps identify emerging needs and lets us fine-tune specification points. The result isn’t just a better product—it’s a more informed cycle of continuous improvement.
NMOR has become emblematic of the wider market shift towards low-impurity, traceable specialty reagents. Recent years brought stricter scrutiny over residual nitrosamines in both industrial and consumer goods. Pharmaceutical recalls related to nitrosamine contamination transformed our QC protocols, adding exhaustive targeted screening and expanding stability studies beyond the minimum standards.
Process automation and in-line analytics anchor our next phase of investment. Operators still review every critical parameter live during production and sign off on in-process samples, but the digital record allows us to compare real-time runs against historic best practices. Onboarding younger process chemists and engineers brings in questions and fresh approaches, sparking ongoing improvements that serve both quality and regulatory needs.
Sustainability is emerging as a related priority. Efforts to recycle process water, improve solvent recovery, and minimize packaging waste run hand-in-hand with our environmental management initiatives. Our analysis of lifecycle impact drives us to select greener process options—even when those come with shorter runs or higher up-front investment. The goal isn’t just safer NMOR—it includes lower-impact production that aligns with larger social goals.
Researchers contacted us to say that shifting from batch-based to campaign-style production improved consistency between lots, especially for method-sensitive applications such as trace nitrosamine analysis in pharmaceuticals. Comparing data over several years, analytical teams reported reduced variance in calibration factor and improved recovery rates, both in spiked water samples and in broader food safety studies. These results underline the real-world differences between “off-the-shelf” approaches and genuine specialization. It’s not just about optimizing parameters or updating certifications—it’s about listening to practical field feedback and acting upon it.
Some environmental clients asked about extending holding times for unopened NMOR vials beyond the standard two-year shelf life. In response, our stability program expanded, including quarterly retesting and side-by-side benchmarking against newly produced batches. Advances in packaging initiated further roundtable discussions, prompting us to share findings with both regulatory and research communities.
Supply chain disruptions, such as global transport delays or material shortages, affected consistency until we implemented secondary sourcing strategies and built site-to-site shipment buffers. Our logisticians monitor supply chain health daily and maintain flexible agreements with carriers to control shipping times and storage conditions.
N-Nitrosomorpholine serves as more than a chemical registry number or batch sheet—its manufacture reflects the sum of choices on sourcing, safety, stewardship, and transparency. We remind ourselves every day that making NMOR means upholding both precision and public trust. It’s a line of work defined by vigilance, accountability, and an ongoing cycle of collaboration with those on the frontlines of science and public safety.
For those who depend on solid, well-documented N-Nitrosomorpholine—be it for environmental research, analytical calibration, or method validation—our commitment stands clear: produce to the highest standards with every run, anticipate and address the evolving landscape of hazards, and do so in a spirit of openness and improvement. That’s the daily reality inside our plant—where the challenges are met with informed teamwork, and solutions are forged from experience.