HS Code |
775293 |
| Product Name | N,N-Diisopropylcarbodiimide |
| Chemical Formula | C7H14N2 |
| Molecular Weight | 126.20 |
| Cas Number | 693-13-0 |
| Appearance | Colorless to pale yellow liquid |
| Density | 0.815 g/mL at 25°C |
| Boiling Point | 145-146°C |
| Flash Point | 30°C (closed cup) |
| Purity | Typically ≥99% |
| Refractive Index | n20/D 1.423 |
| Solubility | Soluble in organic solvents (e.g., dichloromethane, THF) |
| Storage Conditions | Store at room temperature, tightly closed, under inert gas |
| Synonyms | DIC; Diisopropylcarbodiimide |
| Smiles | CCN=C=NC(C)C |
| Inchi | InChI=1S/C7H14N2/c1-5(2)9-7-8-6(3)4/h5-6H,1-4H3 |
As an accredited N,N-Diisopropylcarbodiimide factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | Sigma-Aldrich N,N-Diisopropylcarbodiimide arrives in a 100 mL amber glass bottle, tightly sealed with a screw cap and label. |
| Shipping | N,N-Diisopropylcarbodiimide from Sigma Aldrich/Merck/TCI Chemical is shipped in secure, tightly sealed containers to prevent leakage and exposure. The chemical is classified as hazardous, requiring proper labeling, documentation, and compliance with regulatory guidelines. Shipping typically involves temperature control and protective packaging to ensure safety during transit and delivery. |
| Storage | **N,N-Diisopropylcarbodiimide (DIC) should be stored in a tightly closed container, in a cool, dry, and well-ventilated area, away from sources of moisture and ignition. Protect from direct sunlight, oxidizing agents, acids, and bases. Store at room temperature or as specified by the manufacturer (Sigma-Aldrich/Merck/TCI). Ensure proper labeling and access to appropriate spill containment and safety equipment.** |
Competitive N,N-Diisopropylcarbodiimide prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8615371019725 or mail to sales7@bouling-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@bouling-chem.com
Flexible payment, competitive price, premium service - Inquire now!
N,N-Diisopropylcarbodiimide—known among chemists and manufacturers as DIC—holds a special place in many modern laboratories and production lines. Since we started making and delivering this carbodiimide, our team has seen the chemistry world move from simple manual batch operations to robust, highly automated processes. DIC isn’t new, but the consistent quality and reliability required today has changed a lot. Genuine experience in controlling its synthesis and upholding purity standards makes a difference, not just on paper, but on the shop floor and in practical outcomes.
Our material comes as a colorless to pale yellow liquid, and professional chemists can usually pick out its characteristic faint, musty odor. Purity is critical for reliable reactions—so batch after batch, our analytical team works to maintain content levels above 99%. Typical water content hovers under 0.05%, with trace acid and amine below 0.01%. It boils at around 83–85°C at reduced pressure, which helps minimize loss during rotary evaporation. In the drum or bottle, a dense vapor can build up above the liquid, so we take care in our filling halls to limit atmospheric moisture and keep airborne contaminants far from the product during transfer.
Viscosity stays low, which helps avoid clogging lines or transfer issues. Some firms add stabilizers or additional organics to the package, but our formulation stays simple—maximum DIC in solvent-free form, with a closed fill that reduces both metal contamination and polymeric byproducts. Every shipment our customers get from us matches the agreed certificate, and we keep precise documentation from reactor to warehouse.
The most common destination for DIC in our experience is peptide synthesis. Modern peptide chemistries need reagents that drive amide bond formation with high efficiency and minimum side reaction. DIC’s role: quickly activate carboxylic acids so they couple with amines, yet avoid forming troublesome urea byproducts. Our product gets the nod from firms scaling up from milligrams to multi-kilo runs because it minimizes issues like resin fouling during solid-phase peptide synthesis (SPPS) or loss of sensitive amino acids.
Beyond peptides, chemists building heterocycles and other fine chemicals use DIC to make esters and amides under mild conditions. Specialty resins for paints and adhesives often start with a DIC-activated step. In biotech research, DIC frequently gets chosen when other carbodiimides like EDC or DCC fall short—especially in water-free or high-yield applications. We hear from labs aiming for maximal reproducibility that DIC generates less problematic side products compared to DCC, which tends to make the process easier from purification to waste handling.
Impurities, even at small levels, can stir up a chain of problems. From our perspective, nobody wants costly reruns or wasted raw materials. A subtle variation in water content, or a few extra parts per million of free amine, will trigger extra byproducts—especially in large reactors running continuous or overnight cycles. Systems can clog, filters will gum up and wrangling side reactions adds labor. Our in-depth testing—always checked on modern chromatography and titration equipment—traces origins of even minor off-spec issues, so we can spot issues before an order reaches your facility.
Our documentation tracks every lot from the day raw materials arrive, through every reactor, wash, and packaging run. Quality records and retained samples help answer every audit. People in quality assurance operations know the panic when a critical batch hangs up in regulatory review for trace contaminant questions. By maintaining tight records and reproducible conditions, our team backs up every delivery, batch by batch.
We have handled DCC (N,N'-Dicyclohexylcarbodiimide), EDC (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide), and alternative condensing agents for years, so we see the tradeoffs up close. DIC stands out in terms of solubility and ease of workup. Its liquid state at room temperature means simpler transfer without heating or melting, sparing cleanup and manual handling headaches. DIC does not form persistent solid urea byproducts like DCC, which could clog solid support columns or require high solvent volumes for removal.
If a process runs at scale, DIC’s volatility can be a plus—evaporation leaves behind fewer high-boiling contaminants than DCC, and glassware cleans faster. When contractors or research labs aim to avoid trace ureas in their peptide APIs, DIC fits the bill. It does not boost health risks as DCC can in the workplace, and keeping exposure to dust-forming solids low makes compliance with handling standards easier.
EDC, by contrast, fits best in aqueous or mixed-phase systems—its hydrochloride salt increases water compatibility, making it a favorite for reactions done in water. Where anhydrous and organic-only processes dominate, DIC partners better with popular solvents like DMF, DCM, and acetonitrile. No side salts are generated with DIC, so post-reaction purifications run leaner and generate less waste.
In work with thousands of kilos over two decades, our crews always focus on the basics—ventilation, PPE, and closed handling. DIC releases vapor that carries a risk of respiratory irritation, so drum decanting happens under strict local extraction. Spills do not crust or harden, but can still cause surface swelling and odor that lingers in drain systems. We recommend—because we do this ourselves—that any open transfer gets piped direct to contained vessels with exhaust filtration.
We never rely on unsupported transfer by hand—for big plants, simple pump-out systems or argon-pressured lines cut down on leaks and exposure. In purification, our teams use proven methods: acid-wash glassware and frequent changeover of transfer lines. We have tried both steel and polymeric seals—high-density polyethylene connectors work, but for the purest applications, PTFE joints keep cross-contamination low.
DIC reacts with water—even a little—so anything less than airtight creates risk. Our team prefers metal cans with inert linings or thick-walled fluorinated poly drums, sealed under dry nitrogen. Sometimes, especially for high-throughput peptide facilities, we supply DIC in pre-dispensed ampoules—shrunken headspace, minimal oxygen ingress, all lot-coded and documented for traceability.
If stored tightly sealed in low-humidity conditions, temperature between 15 and 25°C, DIC lasts reliably twelve months or more. Warm, damp air shortens shelf life and increases formation of byproducts that ruin sensitive couplings, so our warehouse is climate-managed, closely monitored for temperature swings and leaks. Every outgoing package travels double-wrapped, with seals cross-checked by batch—we learned long ago that skimping on closure spells trouble for sensitive downstream synthesis.
Peptide and API plants running on strict cGMP requirements bank on predictability. We get regular feedback from those scaling from pilot to multi-metric ton batches. Key factors—dissolution rate and process throughput—depend on both the DIC’s purity and how it handles in automated filling stations. Consistent viscosity and absence of particulates let us fill large reactors without extra filtering. Customers making critical ingredients for clinical trials or regulated substances trust us to troubleshoot process fluctuations.
Sometimes, a process needs customized packaging or ultra-high purity. Our facilities can add extra filtration, extra drying, and specialty packaging formats. Flexible manufacturing means we can shift to smaller lots for R&D-grade product or standardize everything for bulk operations, based entirely on what delivers the best outcomes in our partners' hands. We track returns and feedback so any single drum problem leads straight to corrective action.
We make and ship DIC with a constant watch on environmental outcome. DIC itself reacts in wastewater, so anything unused, along with wash effluent, requires proper neutralization. Our process routes most rinse and filtrate back through scavenging beds to remove any unspent DIC and trace amides. No untreated drain discharge leaves our site—years of experience with local regulations taught us the value of managing waste at the point of origin rather than sending problems downstream.
People handling this chemistry at client sites have told us the same: smaller volumes of urea residue mean less solid waste and lower incineration burden, compared to using DCC. Our environmental control team constantly reviews new pathways for byproduct recovery or reuse. Reducing residual carbodiimide and streamlining solvent washes not only saves cost but keeps our compliance record spotless so end users know they’re not inheriting legacy problems with our product.
Growing global demand means standards differ from client to client—Japanese, European, North American, and Indian regulators all have their own detailed checklists. Satisfying them means adapting both on the production floor and in the lab. Every delivery meets ICH Q7 GMP principles for raw materials used in pharmaceutical and biotech manufacturing. We operate with full batch traceability; every barrel links to signed batch reports, spectral analysis, and archival samples.
We keep certifications up-to-date and our site meets ISO 9001 standards. Market trends show expectations rising each year for contaminant reporting—our experience taught us to anticipate novel requirements, build out new test panels, and routinely validate analytical methods. Our in-house analytical team collaborates with independent auditors for surprise inspections to back up this reputation for transparency. We answer queries about residual solvents, trace metal content, or lot-specific purity with full original lab data.
Our operations team invests in better reactor controls and analytics to reduce batch variance. Newer inline monitoring systems now let us watch endpoint and detect impurities earlier—allowing us to intervene before deviation occurs. These investments aren’t for show; it means less disruption to orders, tighter reproducibility, and shorter lead times for scale-up. By involving both production chemists and experienced scale-up engineers in process design, we find new ways to push yield margins without sacrificing purity.
We also partner with customers developing novel peptides and specialty polymers. When a new synthetic pathway requires unusual solvent systems or non-standard process conditions, we work with their chemists to tweak drying time, filtration methods, or container design—small changes that make a big difference in final product quality. Our R&D group runs constant pilot studies, always searching for improvements in catalyst recovery, byproduct suppression, and energy efficiency.
End-users and development partners provide crucial lessons that drive real-world changes. Some R&D teams shared that DIC purity drifted outside their tighter-than-pharmacopeia specs during long-term storage under poor humidity, prompting us to introduce improved inner seaming and double-vacuum packaging. We’ve also absorbed critical feedback from process engineers about transfer losses; result—custom-dip tubes on large-volume containers and pre-calibrated bulk meters.
The connection between our technical support and those working on the ground keeps surprises to a minimum. Questions on compatibility with new resins, filterability, or reactivity get technical attention—not just a referral to “check the literature.” Many process improvements come directly from audit trails and on-floor troubleshooting, not just internal benchmarks.
DIC has moved from a specialty, high-cost reagent to an essential tool for fast, precise chemical synthesis—from medical research to polymer science, from bench-scale to full commercial scale manufacturing. What sets reliable material apart isn’t just analysis on a certificate—it’s daily discipline, technical flexibility, and relentless improvement in safety and documentation.
Our day-to-day experience as producers means we know the texture of the challenges you face: unpredictable humidity spikes, last-minute regulatory document requests, equipment bottlenecks, scale-up hiccups, and final-stage purification loops. Over the long haul, it’s this boots-on-the-ground perspective that keeps us tuned into both scientific progress and everyday process realities, delivering DIC that our partners and clients can trust in every batch, every time.